Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two web-based meetings and provided input and feedback to early drafts of this document. The most fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most US locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report by Lawrence Berkeley National Laboratory identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two meetings and provided input and feedback to early drafts of this document. The most fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most U.S. locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Looking for Hazardous Pollutants in Your Kitchen

For decades, teams of Berkeley Lab scientists have investigated the ways that indoor air quality affects human health. In Berkeley Lab's test kitchen scientist Brett Singer and his team are measuring the pollutants emitted by cooking foods and evaluating how effective various range hoods are in capturing the pollutants. In an unprecedented recent study, the scientists estimated that 60 percent of homes in California that cook at least once a week with a gas stove can reach pollutant levels that would be illegal if found outdoors.

60 APPLIED LIFE SCIENCES↗

Pollutant concentrations and emission rates from natural gas cooking burners without and with range hood exhaust in nine California homes

Combustion pollutant concentrations were measured during the scripted operation of natural gas cooking burners in nine homes. Boiling and simmering activities were conducted on the stovetop and in the oven with and without range hood exhaust ventilation or air mixing via a forced air system. Time-resolved concentrations of carbon dioxide (CO 2 ), nitric oxide (NO), nitrogen oxides (NO x ), nitrogen dioxide (NO 2 ), particles with diameters of 6 nm or larger (PN), carbon monoxide (CO), and fine particulate matter (PM 2.5 ) were measured in the kitchen and bedroom area of each home. Four of the nine homes had kitchen 1 h NO 2 exceed the national ambient air quality standard (100 ppb). In all homes, the highest 1 h integrated PN exceeded 2 × 10 5 cm -3 -h, and the highest 4 h PN exceeded 3 × 10 5 cm -3 -hr in the kitchen. Range hood performance varied widely, but one with a large capture volume and a measured flow of 108 L/s reduced concentrations 80–95%. Increased awareness of the need to ventilate when cooking, along with building standards for minimum range hood flow rates and volume, could substantially reduce exposures to NO 2 and ultrafine particles in homes.

03 NATURAL GAS↗

Explaining the Accumulation of Intercontinental Biomass Burning Pollution: High Versus Low Processes, Africa Versus South America, Cooking Versus Mixing

The intercontinental buildup of tropospheric ozone, carbon monoxide, and other pollutants over the South Atlantic has been attributed to biomass burning over distant continents. We address several of the large questions regarding the nature and budget of this buildup have remained: What is the role of turning In South America or various portions of Africa in this accumulation? What are the relative roles of shallow and deep convection for emplacing various compounds in the free troposphere? Can we understand the ozone budget? We report the first simulations of a three-dimensional pollutant transport model, (GRACES) transport which is driven by fully reconstructed meteorology for the TRACE-A/SAFARI period of 1992. Greater detail is provided by a two-dimensional, detailed-chemistry model of more restricted regions of Africa. We find a predominant role for African emissions affecting the Atlantic during this period. Boundary-layer venting via PBL convection tends to build the observed carbon monoxide column over the ocean, while deep cumulonimbus processes tend to explain rather more of the ozone column.

Chatfield, Robert B.↗

Development of a Residential Smart Range Hood

This report documents the development testing of a residential smart range hood for automated mitigation of air pollutants generated during cooking events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooking methods and kitchen ventilation availability, usage, perceived performance and potential in Canadian homes

Cooking is a substantial contributor to air pollutant exposures in many residences. Effective use of kitchen ventilation can mitigate exposure; however, information on its availability, usage, and potential to increase its use across the population has been limited. This study aimed to obtain nationally representative information on cooking methods, kitchen ventilation availability and usage, and the potential for education to increase effective usage. An online survey was sent to a representative sample of Canadian homes to collect data on cooking methods, the presence and use of mechanical kitchen ventilation devices, perceived device performance, and willingness to implement mitigation strategies. Responses were weighted to match key demographic factors and analyzed using non-parametric statistics. Among the 4500 respondents, 90% had mechanical ventilation devices over the cooktop (66% of which were vented to the outside), and 30% reported regularly using their devices. Devices were used most often for deep-frying, followed by stir-frying, sautéing or pan-frying, indoor grilling, boiling or steaming. Almost half reported rarely or never using their ventilation devices during baking or oven self-cleaning. Only 10% were fully satisfied with their devices. More frequent use was associated with the device being vented to the outdoors, having more than two speed settings, quiet operation if only one speed, covering over half of the cooktop, and higher perceived effectiveness. After being informed of the benefits of kitchen ventilation, 64% indicated they would consider using their devices more often, preferentially using back burners with ventilation, and/or using higher ventilation device settings when needed. This study provides population-representative data on the most used cooking methods, kitchen ventilation availability and usage, and influencing factors in Canadian homes. Such data are needed for exposure assessments and evaluating the potential to mitigate cooking-related pollutant exposures via more effective use of kitchen ventilation. The data can be reasonably extrapolated to the United States, given the similarities in residential construction practices and cultural norms between the two countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characteristics of Range Hoods in California Homes -- Data Collected from a Real Estate Web Site

Venting range hoods are important residential ventilation components that remove pollutants generated by cooking activities and natural gas cooking burners. To address the lack of data on range hood installations in California, we conducted a survey by examining photographs of homes for sale or rent listed on a popular real estate web site. The survey was conducted in November 2010 and April–May 2011. Posted photos of the homes were reviewed to determine if a hood was installed, the type of hood, and two installation details that can impact performance, namely the height above the cooktop and the degree to which the hood covers the cooktop burners. We additionally collected information about the homes, including asking price for purchase or rent, type of building (e.g. detached house, townhouse or apartment), building age, floor area, and cooktop fuel type. Listings were first sampled to focus on homes built since 2005, then randomly sampled to include varied prices and locations around the state. Data were obtained for 1002 homes built between 1865 and 2011 (median year built 1989). Homes for sale varied in asking price from $\$$16,000 to $\$$16,500,000 (median $\$$353,000) and homes for rent varied from $\$$500 to $\$$25,000 (median $\$$2125) per month. Approximately 74% of the sample had natural gas cooktops. In this sample, natural gas cooktops were more prevalent in more expensive homes than in less expensive homes. Across the entire sample, 7.4 % appeared to have no hood installed, 33% had a short hood, 13% had a deep hood and 47% had a microwave over the range. The percentage of these hoods that vent to the outdoors could not be determined. Hood type was related to coverage of the cooktop. For deep hoods, 76% appeared to cover most or all of the cooktop burners. For short hoods, 70% covered about three quarters of the cooktop. And for microwaves the vast majority (96%) covered the back burners but not the front burners. Hood type was also correlated with asking price or monthly rent, with deep hoods most common in the most expensive homes. Hood type was also correlated with home age, with microwave hoods more common in newer homes. Installation height was related to device type with microwaves installed lower (closer) to the cooktop (median 18 inches), and short hoods (median 28 inches) and deep hoods (median 30 inches) installed higher. Deep range hoods are more common with natural gas cooktops than with electric cooktops, and slightly fewer homes with natural gas cooktops lack a range hood (7%) than homes with electric cooktops (9%). This study provides limited but useful information about the characteristics of range hoods in California homes and demonstrates the potential value of non-traditional forms of data collection.

54 ENVIRONMENTAL SCIENCES↗

Capture Efficiency of Cooking-Related Fine and Ultrafine Particles by Residential Exhaust Hoods

Effective exhaust hoods can mitigate the indoor air quality impacts of pollutant emissions from residential cooking. This study reports capture efficiencies (CE) measured for cooking generated particles for scripted cooking procedures in a 121-m3 chamber with kitchenette. CEs also were measured for burner produced CO2 during cooking and separately for pots and pans containing water. The study used four exhaust hoods previously tested by Delp and Singer (Environ. Sci. Technol., 2012, 46, 6167-6173). For pan-frying a hamburger over medium heat on the back burner, CEs for particles were similar to those for burner produced CO2 and mostly above 80percent. For stir-frying green beans in a wok (high heat, front burner), CEs for burner CO2 during cooking varied by hood and airflow: CEs were 34-38percent for low (51?68 L s-1) and 54?72percent for high (109?138 L s-1) settings. CEs for 0.3?2.0 ?m particles during front burner stir-frying were 3?11percent on low and 16?70percent on high settings. Results indicate that CEs measured for burner CO2 are not predictive of CEs of cooking-generated particles under all conditions, but they may be suitable to identify devices with CEs above 80percent both for burner combustion products and for cooking-related particles.

54 ENVIRONMENTAL SCIENCES↗

Measured Pollutant Performance of Island Overhead Kitchen Exhaust

Cooking is one of the most substantial sources of indoor air pollution in most residences. This is mitigated most often by exhaust devices located near cooking surfaces. In this study, we measured the efficacy of one type of kitchen ventilation device: an island overhead kitchen exhaust. Laboratory tests using tracer gas capture were performed on a full-scale mock-up of a kitchen with a cooktop in an island. The results show that the Capture Efficiency (CE) varies greatly from about 10% to nearly 100%. CE generally increased with exhaust flow rate, but results did not show clear trends when changing hood mounting height or the power input to the cooktop burners. Burner power had an effect on measured capture efficiency of the same magnitude as exhaust flow rate. As with earlier work on wall-mount exhaust hoods, these results indicate that standardized testing will have to clearly specify mounting heights, power input (and or temperatures) and the geometry of the tracer gas emitter.

42 ENGINEERING↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California

This work presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ), formaldehyde and carbon dioxide (CO 2 ) and time-integrated formaldehyde, NO 2 and nitrogen oxides (NO X ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM 2.5 , formaldehyde, NO 2 , and CO 2 were 7.7 µg/m 3 , 14.1 ppb, 18.8 ppb, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM 2.5 above the California annual outdoor standard of 12 µg/m 3 and also discrete days above the World Health Organization 24-h guideline of 25 µg/m 3 . Two apartments had weekly NO 2 above the California annual outdoor standard of 30 ppb.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of Black Carbon and Other Pollutant Emissions from a Traditional and an Improved Cookstove

Traditional methods of cooking in developing regions of the world emit pollutants that endanger the lives of billions of people and contribute to climate change. This study quantifies the emission of pollutants from the Berkeley-Darfur Stove and the traditional three-stone fire at the Lawrence Berkeley National Laboratory cookstove testing facility. The Berkeley-Darfur Stove was designed as a fuel efficient alternative to the three-stone fire to aid refugees in Darfur, who walk long distances from their camps and risk bodily harm in search of wood for cooking. A potential co-benefit of the more fuel efficient stove may be reduced pollutant emissions. This study measured emissions of carbon dioxide, carbon monoxide, particulate matter, and sunlight-absorbing black carbon. It also measured climate-relevant optical properties of the emitted particulate matter. Pollutant monitors were calibrated specifically for measuring cookstove smoke.

54 ENVIRONMENTAL SCIENCES↗

Measured air quality impacts after teaching parents about cooking ventilation with a video: a pilot study

BackgroundCooking-related emissions contribute to air pollutants in the home and may influence children’s health outcomes.ObjectiveIn this pilot study, we investigate the effects of a cooking ventilation intervention in homes with gas stoves, including a video-based educational intervention and range hood replacement (when needed) in children’s homes.MethodsThis was a pilot (n = 14), before-after trial (clinicaltrials.gov #NCT04464720) in homes in the San Francisco Bay Area that had a school-aged child, a gas stove, and either a venting range hood or over-the-range microwave/hood. Cooking events, ventilation use, and indoor air pollution were measured in homes for 2–4 weeks, and children completed respiratory assessments. Midway, families received this intervention: (1) education about the hazards of cooking-related pollutants and benefits of both switching to back burners and using the range hood whenever cooking and (2) ensuring the range hood met airflow and sound performance standards. The educational intervention was delivered via a video developed in conjunction with local youth.ResultsWe found substantially increased use of back burners and slight increases in range hood use during cooking after intervening. Even though there was no change in cooking frequency or duration, these behavior changes resulted in decreases in nitrogen dioxide (NO2), including significant decreases in the total integrated concentration of NO2 over all cooking events from 1230 ppb*min (IQR 336, 7861) to 756 (IQR 84.0, 4210; p < 0.05) and NO2 collected on samplers over the entire pre- and post-intervention intervals from 10.4 ppb (IQR 3.5, 47.5) to 9.4 (IQR 3.0, 36.1; p < 0.005). There were smaller changes in PM2.5, and no changes were seen in respiratory outcomes.ImpactThis pilot before-after trial evaluated the use of a four-minute educational video to improve cooking ventilation in homes with gas stoves and one or more school-aged children. Participant behavior changed after watching the video, and there were decreases in indoor air pollutant concentrations in the home, some of which were significant. This brief video is now publicly available in English and Spanish (wspehsu.ucsf.edu/projects/indoor-air-quality), and this provides suggestive evidence of the utility of this simple intervention, which could be particularly beneficial for households that have children with asthma.

Holm, Stephanie M↗

Comparing extracting and recirculating residential kitchen range hoods for the use in high energy efficient housing

Residential cooking can be a significant indoor source of odour, pollutants and particulate matter. Conventionally, range hoods expel the air into the ambient. A number of studies have investigated their contaminant capture performance. However, for highly energy efficient houses the installation of extracting range hoods can pose certain challenges, e.g. high ventilation losses, additional thermal bridges and potential air leakage sites. Therefore, the use of recirculation range hoods has become standard for highly energy efficient housing with mechanical ventilation with heat recovery in Central Europe. Open questions remain regarding their capture and filtration efficiency as a function of filter age, especially for particles and odours. But also, the actual energy savings potential when using recirculating instead of extracting devices in a highly energy efficient housing had not been documented yet. This paper addresses these questions with a literature review and an energetic comparison. The review identified a good number of studies which have investigated the capture performance of extracting range hoods with a focus on pollutants resulting from gas combustion and/or the cooking generated particles. These studies show that capture efficiency, in particular for front burner use, can vary drastically for different designs and that particle capture does not necessarily match capture efficiency for gaseous contaminants. No scientific study investigating the performance of recirculating range hoods was found. Tests for consumer magazines as well as surveys indicate notably lower performance compared to extracting hoods. In summary one can say that performance tests are urgently needed to quantify the capture and filter efficiency for particles and (odorous) organic compounds as a function of filter age.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Activation of protein kinase B (PKB/Akt) and risk of lung cancer among rural women in India who cook with biomass fuel

The impact of indoor air pollution (IAP) from biomass fuel burning on the risk of carcinogenesis in the airways has been investigated in 187 pre-menopausal women (median age 34 years) from eastern India who cooked exclusively with biomass and 155 age-matched control women from same locality who cooked with cleaner fuel liquefied petroleum gas. Compared with control, Papanicolau-stained sputum samples showed 3-times higher prevalence of metaplasia and 7-times higher prevalence of dysplasia in airway epithelial cell (AEC) of biomass users. Immunocytochemistry showed up-regulation of phosphorylated Akt (p-Akt{sup ser473} and p-Akt{sup thr308}) proteins in AEC of biomass users, especially in metaplastic and dysplastic cells. Compared with LPG users, biomass-using women showed marked rise in reactive oxygen species (ROS) generation and depletion of antioxidant enzyme, superoxide dismutase (SOD) indicating oxidative stress. There were 2–5 times more particulate pollutants (PM{sub 10} and PM{sub 2.5}), 72% more nitrogen dioxide and 4-times more particulate-laden benzo(a)pyrene, but no change in sulfur dioxide in indoor air of biomass-using households, and high performance liquid chromatography estimated 6-fold rise in the concentration of benzene metabolite trans,trans-muconic acid (t,t-MA) in urine of biomass users. Metaplasia and dysplasia, p-Akt expression and ROS generation were positively associated with PM and t,t-MA levels. It appears that cumulative exposure to biomass smoke increases the risk of lung carcinogenesis via oxidative stress-mediated activation of Akt signal transduction pathway. -- Highlights: ► Carcinogenesis in airway cells was examined in biomass and LPG using women. ► Metaplasia and dysplasia of epithelial cells were more prevalent in biomass users. ► Change in airway cytology was associated with oxidative stress and Akt activation. ► Biomass users had greater exposure to respirable PM, B(a)P and benzene. ► Cooking with biomass increases cancer risk in the airways via Akt activation.

60 APPLIED LIFE SCIENCES↗

Towards the development of a standardized testing protocol for overhead island kitchen exhaust devices: Procedures, measurements and paths forward

Cooking is one of the most important sources of airborne pollutants in the indoor environments of residential buildings. Elevated concentrations of NO 2 due to cooking have been reported widely (Garret et al. 1998; Garrett et al. 1999; Mullen et al. 2016; Ryan et al. 1988; Schwab et al. 1994; J. Spengler et al. 1994; J. D. Spengler et al. 1983; Wilson et al. 1995). Many researchers have attributed elevated particulate concentrations to cooking, and some have attributed extremely high short-term concentrations of fine particles (>300 μg/m3) and ultrafine particles (>105 μg/m3) to cooking events (Abdullahi et al. 2013; Abt et al. 2000; Afshari et al. 2005; Buonanno et al. 2009; He et al. 2004; Kearney et al. 2011; Lance A. Wallace et al. 2004; See and Balasubramanian 2008; Stieb et al. 2008; Wallace and Ott 2011; Wheeler et al. 2011; Zhang et al. 2010). Cooking is also a source of other gas-phase pollutants including carbon monoxide, formaldehyde, acrolein, and other volatile organic compounds (Garret et al. 1998; Garrett et al. 1999; Logue et al. 2013; Mullen et al. 2016; Ryan et al. 1988; Schwab et al. 1994; J. Spengler et al. 1994; J. D. Spengler et al. 1983; V. Seaman et al. 2007; Wilson et al. 1995). Lastly, cooking can be a significant source of water vapor, and the water vapor produced from cooking can eventually lead to moisture-related problems (Parrott and Emmel 2003)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spacecraft Cabin Air Quality Control and Its Application to Tight Buildings

Air quality is an important consideration not only for the external environment, but also for the indoor environment. Most people spend a majority of their lives indoors and the air that they breathe is important to their physical and emotional well being. Since most modern building designs have focused on energy efficiency, less fresh air is brought from the outside. As a result, pollutants from building materials, furniture, cleaning, and cooking have no place to go. To make matters worse, most ventilation systems do not include any means for removing pollutants from the recycled air. Unfortunately, pollution at even a small level can result in eye, throat, and lung irritation in addition to chronic headaches, nausea, and fatigue. A spacecraft cabin, which represents the worst case in tight building design, requires special consideration of air quality since any effects pollutants may have on a crewmember can potentially place a mission or other crewmembers at risk. A detailed approach has been developed by the National Aeronautics and Space Administration (NASA) to minimize cabin atmosphere pollution and provide the crew with an environment which is as free of pollutants as possible. This approach is a combination of passive and active contamination control concepts involving the evaluation and selection of materials to be used onboard the spacecraft, the establishment of air quality standards to ensure crew health, and the use of active control means onboard the spacecraft to further ensure an acceptable atmosphere. This approach has allowed NASA to prevent illness by providing crewmembers with a cabin atmosphere which contains pollutant concentrations up to 100 times lower than those specified for terrestrial indoor environments. Standard building construction, however, does not take into account the potentially harmful effects of materials used in the construction process on the health of future occupants and relies primarily on remedial rather than preventive techniques when addressing contamination. This approach results in a building that theoretically has low operating costs, but may actually have high costs associated with lost work days, increased medical claims, decreased productivity, and problem remediation. A similar approach to NASA's may be adopted by the building construction community which can tap the extensive database of material offgassing properties that has been collected to support the space program. Many materials used by NASA are commercially available and are frequently used in building construction. In addition, computer models which have been developed for assessing various methods of active contamination control can be applied to building ventilation system design and the analysis of their economics. Through using NASA' s experience, the expense associated with the current remedial approach can be avoided.