Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling & trapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Coronae of Moderate-Mass Giants in the Hertzsprung Gap and the Clump

We have used the Roentgensatellit (ROSAT), the Extreme Ultraviolet Explorer (EUVE), and the Hubble Space Telescope (HST) to measure X-ray and ultraviolet emissions of moderate-mass (APPROX. 2-3 solar mass) giants in the Hertzsprung gap (spectral types early F to mid-G) and the post-helium flash "clump" (approx. G8-K0). Our motivation was to document the evolution of hot coronae (T greater than 10(exp 6)K) along the post-main-sequence trajectories traveled by such stars in order to gain insight concerning the "X-ray deficiency" of the F-GO giants and the strong braking of stellar rotation at the red edge of the Hertzsprung gap. With few exceptions, Hertzsprung gap and clump giants observed by ROSAT PSPC show hot (T approx. 10(exp 7)K) coronal energy distributions, regardless of any X-ray deficiency, EUVE spectra of gap star 31 Com (G0 111) indicate a broad coronal emission measure hump at approx. 10(exp 7.2)K, while the active clump giant beta Ceti (K0 III) displays a sharp peak at approx. 10(exp 6.8)K, as seen previously in the mixed clump/gap binary Capella (alpha Aur: G8 III + G0 III). The gap giants upsilon Peg (F8 III) and 24 UMa (G4 III) have EUV emissions of intermediate temperature (approx. 10(exp 7.0)K). The stars 31 Com, psi(sup 3) Psc (G0 III), and beta Cet exhibit redshifted transition zone (TZ: approx. 10(exp 5)K) lines in HST GHRS spectra, as reported earlier in Procyon (alpha CMi: F5 IV-V) and Capella G0. Such redshifts on the Sun are thought to signify flows in magnetic loops. beta Cas (F2 III)-a rare soft coronal source among the gap stars-displays blueshifts of C iv and 0 iv], although emissions at cooler and hotter temperatures are near the photospheric velocity. The remarkably broad line profiles of the fastest rotating gap giants suggest that the 10(exp 5) K "subcoronal " emission zones extend to h approx. R(sub *) above the photosphere, about 50 scale heights. In contrast to the TZ line redshifts, the upper chromospheric emissions (e.g., Mg II and Si III) of 31 Com and upsilon(sup 3) Psc have blueshifted cores. Blue-asymmetric peaks in the solar Mg a lines are thought to indicate dynamical heating in the chromosphere. Observations of the H(sub I) Ly(alpha) feature of 31 Com taken 9 months apart reveal striking profile changes, reminiscent of those noted previously in the Ly(alpha) blue peak of the Capella G0 star. We used the far-ultraviolet diagnostics, in combination with ROSAT X-ray photometry and EUVE high-excitation line strengths, to constrain physical models of the stellar outer atmospheres. Quasi-static magnetic loops can simulate the empirical coronal emission measures of the giant stars, but the inferred pressures for sensible loop lengths conflict with direct measurements of subcoronal densities. Furthermore, the high rate of emission at approx. 10(exp 5) K cannot be explained by thermal conduction down the legs of hot quasi-static loops. On the other hand, the possible existence of elongated (l - R(sub *) emission structures on the gap giants leads to a speculative scenario to explain the X-ray deficiency. It is based on the increased importance of the dynamical filling phase ("explosive evaporation") of the loop life cycle; conductive cooling, yielding TZ emissions at the footpoints, when the heating is interrupted; and the possibility for transitions between " hot " and " cool " energy balance solutions owing to dynamical suspension and centrifugal trapping of the cooling gas. The long loops might represent a vestigial global " magnetosphere " inherited from the main-sequence phase, which ultimately is disrupted near approx. G0 by the deepening convective envelope and growth of a more solar-like dynamo. Coronal emissions might be boosted temporarily as the X-ray deficiency is removed but soon would be quenched by wind braking previously inhibited by the magnetospheric "dead zone."

Ayres, Thomas R.↗

Optical probing of cold trapped atoms

Transitions between excited states of laser-cooled and laser-trapped rubidium and cesium atoms are probed by use of fiber and diode lasers. High-resolution Doppler-free spectra are detected by observation of the absorption and fluorescence of light from the intermediate level of two-step cascade systems. The optical double-resonance spectra show Autler-Townes splitting in the weak probe limit and more complicated spectra for a strongly coupled three-level system.

Fox, R. W.↗

Formation of Martian flood features by release of water from confined aquifers

It is proposed that the rapid release of water under great pressure from deeply buried aquifers is responsible for the formation of the Martian channels suggestive of catastrophic flooding (outflow channels). Fine channels in the Martian surface suggest the presence of surface water early in the history of the planet, which would have entered the ground water system through the porous near-surface rocks. Subsequent global cooling would have trapped the ground water under a thick permafrost layer and formed a system of confined aquifers. High pore pressures within the aquifers are considered to have triggered the breakout of water from the aquifers at rates of from 10 to the 5th to 10 to the 7th cu m/sec, which would be prevented from reentering the ground water system by the layer of permafrost. Outflow from the aquifer is also considered to have caused the undermining of adjacent areas and the collapse of the surface to form areas of chaos, often associated with channels.

Carr, M. H.↗

Keynote address: The past, present, and future of atomic time

The early history of atomic time and frequency standards is reviewed. The most accurate and stable present standards are described. Prospective future improvements are discussed, particularly those with laser cooling and with trapped ions and atoms.

Ramsey, Norman F.↗

Buffer Gas Experiments in Mercury (Hg+) Ion Clock

We describe the results of the frequency shifts measured from various buffer gases that might be used as a buffer gas to increase the loading efficiency and cooling of ions trapped in a small mercury ion clock. The small mass, volume and power requirement of space clock precludes the use of turbo pumps. Hence, a hermetically sealed vacuum system, incorporating a suitable getter material with a fixed amount of inert buffer gas may be a practical alternative to the groundbased system. The collision shifts of 40,507,347.996xx Hz clock transition for helium, neon and argon buffer gases were measured in the ambient earth magnetic field. In addition to the above non-getterable inert gases we also measured the frequency shifts due to getterable, molecular hydrogen and nitrogen gases which may be used as buffer gases when incorporated with a miniature ion pump. We also examined the frequency shift due to the low methane gas partial pressure in a fixed higher pressure neon buffer gas environment. Methane gas interacted with mercury ions in a peculiar way as to preserve the ion number but to relax the population difference in the two hyperfine clock states and thereby reducing the clock resonance signal. The same population relaxation was also observed for other molecular buffer gases (N H ,) but at much reduced rate.

mercury ion clock↗

DEVELOPMENT OF A LIGHT-WEIGHT REGENERATIVELY COOLED THRUST CHAMBER WITH BRAZED RIBS AND BRAZED OUTER WIRE TRAP

Design and fabrication procedures are discussed of a brazed-ribtype thrust chamber fabricated from stainless steel or inconel for a Sooo-lb thrust 20: 1 expansion-area-ratio regeneratively cooled liquidpropellant rocket engine which is designated as the JPL 6K Engine and operates at a chamber pressure of 150 psia. Hydrazine is used as the fuel and regenerative coolant and nitrogen tetroxide as the oxidizer. The nozzle-throat diameter is 5.42 in. The thrust chamber consists of a sheet-metal gas-side liner with longitudinal ribs spotwelded and brazed to the outer surface. Wire is wrapped over the ribs circumferentially, spot-welded to the ribs, and brazed. The liner, ribs, and wire form the coolant-passage walls. There are three basic advantages to this type of thrust chamber: light weight, ease of fabrication, and comparatively low cost. The total dry weight of a thrust chamber of this type and size made of 347 stainless steel is 46.2 lb, and the wet weight is 56.3 Ib. A total of 87 static engine tests were made on 19 of 23 thrust chambers fabricated by this technique. Four of the chambers tested had an expansion-area ratio of 20:1, and 15, which were shorter but had the same throat diameter, had an expansion-area ratio of 3.5:l. Accumulated test time was 1926 sec, including 558 sec regenerative cooling with hydrazine and 1368 sec cooling with water. One 20:l thrust chamber was subjected to 16 separate engine tests, with an accumulated test time of 399 sec, and was still in very good operating condition after the tests were completed. With water flowing through the coolant passages at 10 lb/sec, the measured nominal pressure drop between coolant manifolds of a 20:l thrust chamber wrapped with flat wire was 17.2 psi.

Thrust Chamber↗

Gas Trap Plug Design, Function and Performance

The cooling loops of the Internal Active Thermal Control System (IATCS) on the Node 3, Node 2 and US Laboratory (USL) Modules of the International Space Station (ISS) have been serviced by Gas Traps (GTs) since the onset of operations. These traps serve to protect the pumping function of the cooling loops by eliminating free gas that would otherwise impact the impellers and cause a loop shutdown. Gas Trap Plug Assemblies (GTPAs) have been designed, manufactured and tested, to permit function of the IATCS in the event of a loss of cabin atmosphere and long term decrew event. The GTPA also serve to give the crew additional time to evacuate the United States Operating Segment (USOS) in the unlikely event of an Ammonia breach of an Interface Heat Exchanger (IFHX). These GTPAs have been installed on the ISS IATCS since May 2019. This paper will address purpose, design and testing of the GTPA. The paper will also provide analyses showing residual trapping capability and free gas elimination of the GTs even while tightly plugged, for both the GTs and the Alternate Gas Trap Assemblies (AGTAs) ground spares.

Gas Trap Plugs↗

Cooled artery extension

An artery vapor trap. A heat pipe artery is constructed with an extension protruding from the evaporator end of the heat pipe beyond the active area of the evaporator. The vapor migrates into the artery extension because of gravity or liquid displacement, and cooling the extension condenses the vapor to liquid, thus preventing vapor lock in the working portion of the artery by removing vapor from within the active artery. The condensed liquid is then transported back to the evaporator by the capillary action of the artery extension itself or by wick located within the extension.

Gernert, Nelson J.↗

Prospects for atomic frequency standards

The potentialities of different atomic frequency standards which are not yet into field operation, for most of them, but for which preliminary data, obtained in laboratory experiments, give confidence that they may improve greatly the present state of the art are described. The review will mainly cover the following devices: (1) cesium beam frequency standards with optical pumping and detection; (2) optically pumped rubidium cells; (3) magnesium beam; (4) cold hydrogen masers; and (5) traps with stored and cooled ions.

Audoin, C.↗

Polytropic relationship in interplanetary magnetic clouds

High time-resolution data from the ISEE 3 and IMP 8 spacecraft are presented for the magnetic field and the proton and electron populations of a number of magnetic clouds, in order to investigate such clouds' thermodynamics and the relationship between their magnetic and thermodynamic structures. It is judged on the basis of these data that while the magnetic flield of the cloud expands, the ions are cooled. Hot electrons are trapped by the magnetic field in the magnetic cloud's core. These conditions are favorable for the generation of ion-acoustic waves.

Osherovich, V. A.↗

New Hydrophilic, Composite Membranes for Air Removal from Water Coolant Systems

Liquid coolants are commonly used as thermal transport media to increase efficiency and flexibility in aerospace vehicle design. The introduction of gas bubbles into the coolant can have negative consequences, including: loss of centrifugal pump prime, irregular sensor readings, and blockage of coolant flow to remote systems. One solution to mitigate these problems is the development of a passive gas removal device, or gas trap, installed in the flight cooling system. In this study, a new hydrophilic, composite membrane has been developed for passage of the coolant fluid and retention of gas bubbles. The trapped bubbles are subsequently vented from the system by a thin, hydrophobic, microporous membrane. The original design for this work employed a homogeneous membrane that was susceptible to fouling and pore plugging. Spare gas traps of this variety have degraded during storage, and recreation of the membranes has been complicated due to problems with polymer duplication and property variations in the final membranes. In this work, replacements have been developed based on deposition of a hydrophilic polymer on the bore-side of a porous polyethylene (PE) tube. The tube provides excellent chemical and mechanical stability, and the hydrophilic layer provides retention of gas bubbles. Preliminary results have shown that intimate contact is required between the deposited layer and the substrate to overcome material differences. This has been accomplished by presoaking the membrane tube in the solvent to raise its surface energy. Polymer solutions of various concentrations have been used to promote penetration of the polymer layer into the porous substrate and to control separation layer thickness. The resulting composite membranes have shown repeatable decrease in nitrogen permeability, which is indicative of a decrease in membrane pore size. Studies with water permeation have yielded similar results. We have observed some swelling of the added polymer layer, which causes a slight decrease in membrane pore size, and should result in improved bubble retention. Preliminary studies have also been performed on gas retention in flowing systems. Initial results have been promising, with negligible gas permeation for the coated membranes compared to 100% gas permeation in the uncoated tube.

Ritchie, Stephen M. C.↗

Galactic oscillations

Several oscillations have been identified in spherical galaxy models. These are normal mode oscillations in a stable galaxy. Each has its own distinct period and spatial form, and each rings without detectable damping through a Hubble time. The most important are: (1) a simple radial pulsation (fundamental mode), in which all parts of the galaxy move inward or outward with the same phase; and (2) a second spherically symmetrical radial mode with one node, so material inside the node moves outward when material outside moves inward. Numerical experiments suggest that normal mode oscillations may be present in nearly all galaxies at a considerably higher amplitude than has previously been thought. Amplitudes typically run a few percent of equilibrium values, and periods are around 50-300 Myrs in typical galaxies. These time scales are long enough that gas trapped near the center could cool during an oscillation cycle, allowing star formation activity. The second mode oscillations could cause bursts of star formation.

Smith, B. F.↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Method and apparatus for producing microshells

A method is described for forming hollow particles, or shells, of extremely small size. The shell material is heated to a molten temperature in the presence of a gas that is at least moderately soluble in the shell material, to form a solution of the molten shell material and the soluble gas. The solution is atomized to form a multiplicity of separate droplets that are cooled while in free fall. Cooling of a droplet from the outside traps the desolved gas and forces it to form a gas bubble at the center of the droplet which now forms a gas filled shell. The shell is reheated and then cooled in free fall, in an environment having a lower pressure than the gas pressure in the shell. This causes expansion of the shell and the formation of a shell having a small wall thickness compared to its diameter.

Lee, Mark C.↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗