Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers

A design of an Active Magnetic Regenerative Refrigeration (AMRR) system has been developed for space applications. It uses an innovative 3He cryogenic circulator to provide continuous remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. A critical component technology for this cooling system is a highly efficient active magnetic regenerator, which is a regenerative heat exchanger with its matrix material made of magnetic refrigerant gadolinium gallium garnet (GGG). Creare Inc. is developing a microchannel GGG regenerator with an anisotropic structured bed for high system thermal efficiency. The regenerator core consists of a stack of thin, single-crystal GGG disks alternating with thin polymer insulating layers. The insulating layers help minimize the axial conduction heat leak, since GGG has a very high thermal conductivity in the regenerator s operating temperature range. The GGG disks contain micro channels with width near 100 micrometers, which enhance the heat transfer between the circulating flow and the refrigerant bed. The unique flow configuration of the GGG plates ensures a uniform flow distribution across the plates. The main fabrication challenges for the regenerator are the machining of high-aspect-ratio microchannels in fragile, single-crystal GGG disks and fabrication and assembly of the GGG insulation layers. Feasibility demonstrations to date include use of an ultrashort- pulse laser to machine microchannels without producing unacceptable microcracking or deposition of recast material, as shown in the figure, and attachment of a thin insulation layer to a GGG disk without obstructing the flow paths. At the time of this reporting, efforts were focused on improving the laser machining process to increase machining speed and further reduce microcracking.

Chen, Weibo↗

An Experimental Investigation and Correlation of the Heat Reduction to Nonporous Surfaces Behind a Porous Leading Edge Through Which Coolant is Ejected

A configuration of a wing segment having constant chord thickness, 0 deg. sweep, a porous steel semicircular leading edge, and solid Inconel surfaces was tested in a Mach number 2.0 ethlyene-heated high-temperature air jet. Measurements were made of the wing surface temperatures at chordwise stations for several rates of helium flow through the porous leading edge. The investigation was conducted at stagnation temperatures ranging from 500 F to 2,400 F, at Reynolds numbers per foot ranging from 0.3 x 10(exp 7) to 1.2 x 10(exp 7), and at angles of attack of 0, +/- 5, and +/- 15 deg. The results indicated that the reduction of wing surface temperatures with respect to their values for no coolant flow, depended on the helium coolant flow rates and the distance behind the area of injection. The results were correlated in terms of the wall cooling parameter and the coolant flow-rate parameter, where the nondimensional flow rate was referenced to the cooled area up to the downstream position. For the same coolant flow rate, lower surface temperatures are achieved with a porous-wall cooling system. However, since flow-rate requirements decrease with increasing allowable surface temperatures, the higher allowable wall temperatures of the solid wall as compared to the structurally weaker porous wall- sharply reduce the flow-rate requirements of a downstream cooling system. Thus, for certain flight conditions it is possible to compensate for the lower efficiency of the downstream or solid-wall cooling system. For example, a downstream cooling system using solid walls that must be maintained at 1,800 F would require less coolant for Mach numbers up to 5.5 than would a porous-wall cooling system for which the walls must be maintained at temperatures less than or equal to 9000 F.

Witte, William G.↗

Space Shuttle Upgrades Advanced Hydraulic Power System

Three Auxiliary Power Units (APU) on the Space Shuttle Orbiter each provide 145 hp shaft power to a hydraulic pump which outputs 3000 psi hydraulic fluid to 41 hydraulic actuators. A hydrazine fuel powered APU utilized throughout the Shuttle program has undergone many improvements, but concerns remain with flight safety, operational cost, critical failure modes, and hydrazine related hazards. The advanced hydraulic power system (AHPS), also known as the electric APU, is being evaluated as an upgrade to replace the hydrazine APU. The AHPS replaces the high-speed turbine and hydrazine fuel supply system with a battery power supply and electric motor/pump that converts 300 volt electrical power to 3000 psi hydraulic power. AHPS upgrade benefits include elimination of toxic hydrazine propellant to improve flight safety, reduction in hazardous ground processing operations, and improved reliability. Development of this upgrade provides many interesting challenges and includes development of four hardware elements that comprise the AHPS system: Battery - The battery provides a high voltage supply of power using lithium ion cells. This is a large battery that must provide 28 kilowatt hours of energy over 99 minutes of operation at 300 volts with a peak power of 130 kilowatts for three seconds. High Voltage Power Distribution and Control (PD&C) - The PD&C distributes electric power from the battery to the EHDU. This 300 volt system includes wiring and components necessary to distribute power and provide fault current protection. Electro-Hydraulic Drive Unit (EHDU) - The EHDU converts electric input power to hydraulic output power. The EHDU must provide over 90 kilowatts of stable, output hydraulic power at 3000 psi with high efficiency and rapid response time. Cooling System - The cooling system provides thermal control of the Orbiter hydraulic fluid and EHDU electronic components. Symposium presentation will provide an overview of the AHPS upgrade, descriptions of the four hardware elements, and a summary of development results to date.

Source record↗

Aid To Solar Collector Development

Solar heating and cooling systems employ coatings to increase efficiency. Designers want a coating which absorbs solar heat to the maximum extent possible with minimal emittance of infrared radiation, which occurs when the collector plate gets hot. The coating is important because too much coating causes energy loss by emittance, too little reduces the collector's ability to absorb heat. NASA's Lewis Research Center, which conducts solar energy research, saw a need for a simple means of testing coating samples for emittance. Such equipment is available to research laboratories, but it is complex and expensive

Source record↗

JSC space base/power module studies

Users of the Orbiter/Spacelab combination will require both higher electrical power and longer duration than is available with the current baseline system. Present Orbiter/Spacelab mission capability is primarily constrained by the hydrogen and oxygen available to generate power in the Orbiter fuel cells. It is also necessary to assure that considerable attitude or point flexibility is retained to assure efficient operation of the Orbiter radiator cooling system. Beyond these early limitations, it is foreseen that orbital operations will eventually need even greater quantities of the basic space utilities: electrical power; heat rejection; and attitude control. Such operations, forecasted for the mid to late 1980's, will be best accommodated by a module stored in orbit that can furnish these to a docked Orbiter/Spacelab or other vehicles. The Orbital Service Module concept to provide for these services is presented.

Craig, J. W.↗

Technique for Configuring an Actively Cooled Thermal Shield in a Flight System

Broad area cooling shields are a mass-efficient alternative to conductively cooled thermal radiation shielding. The shield would actively intercept a large portion of incident thermal radiation and transport the heat away using cryogenic helium gas. The design concept consists of a conductive and conformable surface that maximizes heat transfer and formability. Broad Area Cooled (BAC) shields could potentially provide considerable mass savings for spaceflight applications by eliminating the need for a rigid thermal radiation shield for cryogen tanks. The BAC consists of a network of capillary tubes that are thermally connected to a conductive shield material. Chilled helium gas is circulated through the network and transports unwanted heat away from the cryogen tanks. The cryogenic helium gas is pumped and chilled simultaneously using a specialized pulse-tube cryocooler, which further improves the mass efficiency of the system. By reducing the thermal environment temperature from 300 to 100 K, the radiative heat load on a cryogen tank could be reduced by an order of magnitude. For a cryogenic liquid propellant scenario of oxygen and hydrogen, the boiloff of hydrogen would be significantly reduced and completely eliminated for oxygen. A major challenge in implementing this technology on large tanks is that the BAC system must be easily scalable from lab demonstrations to full-scale missions. Also, the BAC shield must be conformable to complex shapes like spheres without losing the ability to maintain constant temperature throughout. The initial design maximizes thermal conductivity between the capillary tube and the conductive radiation shielding by using thin, corrugated aluminum foil with the tube running transverse to the folds. This configuration has the added benefit of enabling the foil to stretch and contract longitudinally. This allows the BAC to conform to the complex curvature of a cryogen tank, which is key to its success. To demonstrate a BAC shield system with minimal impact to current cryogen tank designs, the shielding must be applied after the final assembly of the tank and supporting structure. One method is to pre-fabricate the shield in long strips. A spool of corrugated aluminum foil with a thermally sunk aluminum capillary running through the center could then be simply wound around the cryogen tanks and encapsulated within the multi-layer insulation (MLI) blanket. Then, on orbit, the BAC would intercept thermal radiation coming in through the MLI and transport it away from the cryogen tanks. An optimization of the design could be done to take into account mass savings from thinner MLI blankets, eliminating solid thermal shields, and ultimately, a reduction in the required cryogen tank size.

Barkfknecht, Peter↗

Solar photochemical process engineering for production of fuels and chemicals

The engineering costs and performance of a nominal 25,000 scmd (883,000 scfd) photochemical plant to produce dihydrogen from water were studied. Two systems were considered, one based on flat-plate collector/reactors and the other on linear parabolic troughs. Engineering subsystems were specified including the collector/reactor, support hardware, field transport piping, gas compression equipment, and balance-of-plant (BOP) items. Overall plant efficiencies of 10.3 and 11.6% are estimated for the flat-plate and trough systems, respectively, based on assumed solar photochemical efficiencies of 12.9 and 14.6%. Because of the opposing effects of concentration ratio and operating temperature on efficiency, it was concluded that reactor cooling would be necessary with the trough system. Both active and passive cooling methods were considered. Capital costs and energy costs, for both concentrating and non-concentrating systems, were determined and their sensitivity to efficiency and economic parameters were analyzed. The overall plant efficiency is the single most important factor in determining the cost of the fuel.

Biddle, J. R.↗

Solar photochemical process engineering for production of fuels and chemicals

The engineering costs and performance of a nominal 25,000 scmd (883,000 scfd) photochemical plant to produce dihydrogen from water were studied. Two systems were considered, one based on flat-plate collector/reactors and the other on linear parabolic troughs. Engineering subsystems were specified including the collector/reactor, support hardware, field transport piping, gas compression equipment, and balance-of-plant (BOP) items. Overall plant efficiencies of 10.3 and 11.6 percent are estimated for the flat-plate and trough systems, respectively, based on assumed solar photochemical efficiencies of 12.9 and 14.6 percent. Because of the opposing effects of concentration ratio and operating temperature on efficiency, it was concluded that reactor cooling would be necessary with the trough system. Both active and passive cooling methods were considered. Capital costs and energy costs, for both concentrating and non-concentrating systems, were determined and their sensitivity to efficiency and economic parameters were analyzed. The overall plant efficiency is the single most important factor in determining the cost of the fuel.

Biddle, J. R.↗

Magnetic-Flux-Compression Cooling Using Superconductors

Proposed magnetic-flux-compression refrigeration system produces final-stage temperatures below 4.2 K. More efficient than mechanical and sorption refrigerators at temperatures in this range. Weighs less than comparable liquid-helium-cooled superconducting magnetic refrigeration systems operating below 4.2 K. Magnetic-flux-compression cooling stage combines advantages of newly discovered superconductors with those of cooling by magnetization and demagnetization of paramagnetic salts.

Strayer, Donald M.↗

The development of a solar powered residential heating and cooling system

A solar energy collector design is disclosed that would be efficient for both energy transfer and fluid flow, based upon extensive parametric analyses. Thermal design requirements are generated for the energy storage systems which utilizes sensible heat storage in water. Properly size system components (including the collector and storage) and a practical, efficient total system configuration are determined by means of computer simulation of system performance.

Oneill, M. J.↗

A fixed tilt solar collector employing reversible vee-trough reflectors and vacuum tube receivers for solar heating and cooling systems

The usefulness of vee-trough concentrators in improving the efficiency and reducing the cost of collectors assembled from evacuated tube receivers was studied in the vee-trough/vacuum tube collector (VTVTC) project. The VTVTC was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrator and the thermal performance of the evacuated tube receiver. A test bed was constructed to verify the mathematical analyses and compare reflectors made out of glass, Alzak and aluminized FEP Teflon. Tests were run at temperatures ranging from 95 to 180 C. Vee-trough collector efficiencies of 35 to 40% were observed at an operating temperature of about 175 C. Test results compared well with the calculated values. Predicted daily useful heat collection and efficiency values are presented for a year's duration of operation temperatures ranging from 65 to 230 C. Estimated collector costs and resulting thermal energy costs are presented. Analytical and experimental results are discussed along with a complete economic evaluation.

Selcuk, M. K.↗

On-Orbit and Ground Performance of the PGBA Plant Growth Facility

PGBA, a plant growth facility developed for commercial space biotechnology research, successfully grew a total of 30 plants (6 species) for 10 days on board the Space Shuttle Endeavour (STS-77) and is scheduled for reflight on board MSL-1 (STS-83) for a 16 day flight. The PGBA life support systems provide atmospheric, thermal, and humidity control as well as lighting and nutrient supply in a 23.6 liter chamber. Atmosphere treatment includes ethylene and other hydrocarbon removal, CO2 replenishment, and O2 control. The normally closed system uses controlled CO2 replenishment from the crew cabin as required by the plants. Temperature is controlled (1 C) at user-specified setpoints between 20-32 C, using water-filled coolant loops, solid state Peltier thermoelectric devices, and liquid heat exchangers. The thermoelectric cooling systems were optimized for low power consumption and high cooling efficiencies. Relative humidity is maintained between 60-100% using a cooled porous metal plate to remove water vapor from the air stream without cooling the bulk air below the dew point. The lighting system utilizes three compact fluorescent bi-axial lights with variable lighting control and light intensity (PAR) between 220 and 330 micromol/sq m/s at a distance of 20 cm in spaceflight configuration (on orbit power limited to 230 Watt for entire payload). A ground, up to 550 micromol/sq m/s light intensity can be achieved with 330 Watt payload power consumption. Plant water and nutrient support is sustained via the 'Nutrient Pack' system including the passive or active 'Water Replenishable Nutrient Pack.' The root matrix material (soil or Agar) and nutrient formulation of each pack is prepared according to plant species and experimental requirements. These systems were designed by NASA Ames personnel. Data acquisition and control systems provide 32 channels of environmental data as well as digitized or analog video signals for downlink.

Hoehn, A.↗

Preliminary Tests of Blowers of Three Designs Operating in Conjunction with a Wing-Duct Cooling System for Radial Engines, Special Report

This paper is one of several dealing with methods intended to reduce the drag of present-day radial engine installations and improve the cooling at zero and low air speeds, The present paper describes model wind-tunnel tests of blowers of three designs tested in conjunction with a wing-nacelle combination. The principle of operation involved consists of drawing cooling air into ducts located in the wing root at the point of maximum slipstream velocity, passing the air through the engine baffles from rear to front, and exhausting the air through an annular slot located between the propeller and the engine with the aid of a blower mounted on the spinner. The test apparatus consisted essentially of a stub wing having a 5-foot chord and a 15-foot span, an engine nacelle of 20 inches diameter enclosing a 25-horsepower electric motor, and three blowers mounted on propeller spinners. Two of the blowers utilize centrifugal force while the other uses the lift from airfoils to force the air out radially through the exit slot. Maximum efficiencies of over 70 percent were obtained for the system as a whole. Pressures were measured over the entire flight range which were in excess of those necessary to cool present-day engines, The results indicated that blowers mounted on propeller spinners could be built sufficiently powerful and efficient to warrant their use as the only, or chief, means of forcing air through the cooling system, so that cooling would be independent of the speed of the airplane.

Biermann, David↗

Stationary Testing of a Pulse Tube Cryocooler Designed to Rotate at 6800 RPM with the Superconducting Rotor of an Electric Machine

Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Most of these electric machines employ superconductors on their rotor, thereby requiring cryogenic cooling of the rotating system. An attractive solution is to conductively cool the rotor using a cryocooler that rotates with the rotor. NASA has been developing a 50 K pulse tube cryocooler for its High Efficiency Megawatt Motor (HEMM) that can operate while rotating at up to 6,800 rpm. The first non-rotating tests of the fully assembled HEMM cryocooler have been completed, and initial testing has yielded a no-load temperature of 112 K. A small helium leak into the vacuum system has been identified as the major bottleneck to performance, and based on measurements with the motor turned off there is an observed vacuum-side heat leak of approximately 30 W at 115 K. Immediate next steps for testing are to locate and mitigate the apparent helium leaks into the vacuum chamber. Thus far, compressor performance and the apparent heat lift after correcting for the heat leak are on par with expectations.

Electrified Aircraft Propulsion↗

Efficient Design in a DC to DC Converter Unit

Space Flight hardware requires high power conversion efficiencies due to limited power availability and weight penalties of cooling systems. The International Space Station (ISS) Electric Power System (EPS) DC-DC Converter Unit (DDCU) power converter is no exception. This paper explores the design methods and tradeoffs that were utilized to accomplish high efficiency in the DDCU. An isolating DC to DC converter was selected for the ISS power system because of requirements for separate primary and secondary grounds and for a well-regulated secondary output voltage derived from a widely varying input voltage. A flyback-current-fed push-pull topology or improved Weinberg circuit was chosen for this converter because of its potential for high efficiency and reliability. To enhance efficiency, a non-dissipative snubber circuit for the very-low-Rds-on Field Effect Transistors (FETs) was utilized, redistributing the energy that could be wasted during the switching cycle of the power FETs. A unique, low-impedance connection system was utilized to improve contact resistance over a bolted connection. For improved consistency in performance and to lower internal wiring inductance and losses a planar bus system is employed. All of these choices contributed to the design of a 6.25 KW regulated dc to dc converter that is 95 percent efficient. The methodology used in the design of this DC to DC Converter Unit may be directly applicable to other systems that require a conservative approach to efficient power conversion and distribution.

Bruemmer, Joel E.↗

Selecting an Encapsulant for an Aerospace Superconducting Machine

Achieving larger benefits from electrified propulsion in single aisle aircraft (the largest commercial aircraft market segment) necessitates that a significant fraction of their 20 MW or greater propulsion system be electrified. These aircraft would require up to 10-20 of today’s state-of-the art machines, which have been demonstrated up to 2.5 MW for aerospace use, and could benefit further from 5 MW+ designs. However, when conventionally cooled, high power density machines still produce a significant amount of waste heat, translating into heavy thermal management and detracting from system benefits. Highly efficient fully superconducting electric machines (or those with a cryogenically cooled, high purity copper or aluminum stator) are a possible solution but have multiple barriers to overcome. One such barrier is the durability of superconducting windings. Superconductors are typically brittle, and encapsulants used to hold windings in place are a significant source of stress due to mismatches in coefficient of thermally induced contraction between ambient and operational temperatures (20 to 77 K). Lack of compliance between the materials at operational temperatures also adds significant stress. These encapsulants also form a thermal barrier that can be detrimental to cooling the superconductors. This work describes an initial study of commercially available encapsulants as it relates to superconducting machine applications, along with initial modeling of thermal stress in superconducting windings for a superconducting or cryogenically cooled stator in a 5 MW electric machine.

encapsulant↗

Kinetic modeling of an IBr solar pumped laser

The possibility of using an IBr laser as a solar-energy converter is examined theoretically, and reasons for its choice are given. Broadband absorption results in dissociation with the formation of excited metastable Br atoms, some of which then lase to the ground state Br. The ground state is depopulated by three-body recombination and, more importantly, by exchange reactions which more than compensate for the high quenching in heteronuclear halogen systems. Kinetic modeling indicates lasing is possible in the pulsed mode and possibly in the steady state with a cooled gas flow system. Temperature effects are discussed. The efficiency of the laser approaches 1.2 percent at optical thicknesses large enough for complete absorption of the photons.

Harries, W. L.↗

Combustion devices technology team - An overview and status of STME-related activities

The Consortium for CFD applications in propulsion technology has been formed at NASA/Marshall Space Flight Center. The combustion devices technology team is one of the three teams that constitute the Consortium. While generally aiming to advance combustion devices technology for rocket propulsion, the team's efforts for the last 1 and 1/2 years have been focused on issues relating to the Space Transportation Main Engine (STME) nozzle. The nozzle design uses hydrogen-rich turbine exhaust to cool the wall in a film/dump scheme. This method of cooling presents challenges and associated risks for the nozzle designers and the engine/vehicle integrators. Within the nozzle itself, a key concern is the ability to effectively and efficiently film cool the wall. From the National Launch System vehicle base standpoint, there are concerns with dumping combustible gases at the nozzle exit and their potential adverse effects on the base thermal environment. The Combustion Team has developed and is implementing plans to use validated CFD tools to aid in risk mitigation for both areas.

Tucker, P. K.↗