Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coronary Disease”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Relationships between coronary heart disease risk factors and serum ionized calcium in Kennedy Space Center Cohort

Kennedy Space Center (KSC) employees are reported to be at high risk for coronary heart disease (CHD). Risk factors for CHD include high serum total cholesterol levels, low levels of high-density lipoprotein cholesterol (HDLC), elevated triglyceride, smoking, inactivity, high blood pressure, being male, and being older. Higher dietary and/or serum calcium Ca(++) may be related to a lower risk for CHD. Fifty men and 37 women participated. Subjects were tested in the morning after fasting 12 hours. Information relative to smoking and exercise habits was obtained; seated blood pressures were measured; and blood drawn. KCS men had higher risk values than KCS women as related to HDLC, triglycerides, systolic blood pressure, and diastolic blood pressure. Smoking and nonsmoking groups did not differ for other risk factors or for serum Ca(++) levels. Exercise and sedentary groups differed in total cholesterol and triglyceride levels. Serum Ca(++) levels were related to age, increasing with age in the sedentary group and decreasing in the exercisers, equally for men and women. It is concluded that these relationships may be significant to the risk of CHD and/or the risk of bone demineralization in an aging population.

Goodwin, Lisa Ann↗

Multi-channel System for Beat to Beat QT Interval Variability and its Use in Screening for Coronary Artery Disease and Cardiomyopathy

We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.

Starc, V.↗

Usefulness of Derived Frank Lead Parameters in Screening for Coronary Artery Disease and Cardiomyopathy

We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.

DePalma, J. L.↗

Terrestrial Cardiovascular Coronary Artery Disease (CAD) Screening, Treatment and Risk Mitigation - Lessons Learned from Space Medicine

The Bellagio II Summit sought to correlate current ISS (International Space Station) Space Medicine practice in the screening/assessment and management of CAD (Coronary Artery Disease) and to identify terrestrial applications for the general population pertaining to primary, secondary and tertiary diagnoses and treatments. We identified current Space Medicine practice for screening and monitoring cosmonaut and astronaut in the pre-, in-, and post-flight mission phases. We will discuss current Space Medicine standards and guidelines in the recognition and monitoring of CAD development, stabilization, and regression.

Johnston, Smith↗

Quantitative analysis of regional myocardial performance in coronary artery disease

Findings from a group of subjects with significant coronary artery stenosis are given. A group of controls determined by use of a quantitative method for the study of regional myocardial performance based on the frame-by-frame analysis of biplane left ventricular angiograms are presented. Particular emphasis was placed upon the analysis of wall motion in terms of normalized segment dimensions, timing and velocity of contraction. The results were compared with the method of subjective assessment used clinically.

Stewart, D. K.↗

Placental Induced Growth Factor (PIGf) in Coronary Artery Disease

Our previous studies on normal human lymphocytes have shown a five-fold increase (p less than 0.001) in angiogenic inducers such as Placental Induced Growth Factor (PIGf) in physiologically stressful environments such as modeled microgravity, a space analog. This suggests de-regulation of cardiovascular signalling pathways indicated by upregulation of PIGf. In the current study, we measured PIGf in the plasma of 33 patients with and without coronary artery disease (CAD) to investigate whether such disease is associated with increased levels of PIGf. A control consisting of 31 sex matched apparently healthy subjects was also included in the study. We observed that the levels of PIGf in CAD patients were significantly increased compared to those in healthy control subjects (p less than 0.001) and usually increased beyond the clinical threshold level (greater than 27ng/L). The mechanisms leading to up-regulation of angiogenic factors and the adaptation of organisms to stressful environments such as isolation, high altitude, hypoxia, ischemia, microgravity, increased radiation, etc are presently unknown and require further investigation in spaceflight and these other physiologically stressed environments.

Sundaresan, Alamelu↗

Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present method is the presence versus the absence of reduced-amplitude zones (RAZs). In terms that must be simplified for the sake of brevity, an RAZ comprises several cycles of a high-frequency QRS signal during which the amplitude of the high-frequency oscillation in a portion of the signal is abnormally low (see figure). A given signal sample exhibiting an interval of reduced amplitude may or may not be classified as an RAZ, depending on quantitative criteria regarding peaks and troughs within the reduced-amplitude portion of the high-frequency QRS signal. This analysis is performed in all 12 leads in real time.

Schlegel, Todd T.↗

Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

Software↗

A program to reduce coronary heart disease risk by altering job stresses

This study reports the design, implementation, and evaluation of a program attempting to reduce job stress by improving person-environment fit with respect to job aspects such as work load, responsibility, and interpersonal relationships. In order to assess the effects of the program, measures of both stress and strain were collected at three points in time--just prior to the program, immediately after the program, and three months after completion of the program. Measures of strain included systolic and diastolic blood pressure, determinations of glucose, cholesterol, and uric acid in the plasma, job satisfaction, and job related self-esteem. The findings were interpreted in light of both program incidents within specific experimental groups and general aspects of the program common to the experimental groups. Additional analyses indicated that both good person-environment fit with respect to participation predicts to good fit with respect to other job aspects over a three month interval and that stress causes strain, rather than the reverse.

Campbell, D. B.↗

High Frequency QRS ECG Accurately Detects Cardiomyopathy

High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing RAZ scoring is a simple, accurate and inexpensive screening technique for cardiomyopathy. Although HF QRS ECG is highly sensitive for cardiomyopathy, its specificity may be compromised in patients with cardiac pathologies other than cardiomyopathy, such as uncomplicated coronary artery disease or multiple coronary disease risk factors. Further studies are required to determine whether HF QRS might be useful for monitoring cardiomyopathy severity or the efficacy of therapy in a longitudinal fashion.

Schlegel, Todd T.↗

Medical Image Analysis Facility

To improve the quality of photos sent to Earth by unmanned spacecraft. NASA's Jet Propulsion Laboratory (JPL) developed a computerized image enhancement process that brings out detail not visible in the basic photo. JPL is now applying this technology to biomedical research in its Medical lrnage Analysis Facility, which employs computer enhancement techniques to analyze x-ray films of internal organs, such as the heart and lung. A major objective is study of the effects of I stress on persons with heart disease. In animal tests, computerized image processing is being used to study coronary artery lesions and the degree to which they reduce arterial blood flow when stress is applied. The photos illustrate the enhancement process. The upper picture is an x-ray photo in which the artery (dotted line) is barely discernible; in the post-enhancement photo at right, the whole artery and the lesions along its wall are clearly visible. The Medical lrnage Analysis Facility offers a faster means of studying the effects of complex coronary lesions in humans, and the research now being conducted on animals is expected to have important application to diagnosis and treatment of human coronary disease. Other uses of the facility's image processing capability include analysis of muscle biopsy and pap smear specimens, and study of the microscopic structure of fibroprotein in the human lung. Working with JPL on experiments are NASA's Ames Research Center, the University of Southern California School of Medicine, and Rancho Los Amigos Hospital, Downey, California.

Source record↗

Laboratory Aspects of Blood Lipids

Classification of blood hyperlipemias by electrophoresis or ultracentrifugation according to density fraction is described and therapeutic measures for humans with hyperlipoproteinemia are outlined. The statistically significant relationship between high serum cholesterol levels and incidence of coronary disease prescribes restricted caloric intake or physical exercise to burn excess calories as preventive measures.

Townsend, F. M.↗

The Coronary Patient in Industry

The coronary patient, as he pertains to industry particularly NASA, is discussed. Concepts of precoronary care, acute attacks which may develop while on the job, and the return of the cardiac patient to work are covered. Major emphasis was on the prevention of sudden death due to coronary disease.

Schuster, B.↗

Noninvasive aortic bloodflow by Pulsed Doppler Echocardiography (PDE) compared to cardiac output by the direct Fick procedure

Left ventricular stroke volume was estimated from the systolic velocity integral in the ascending aorta by pulsed Doppler Echocardiography (PDE) and the cross sectional area of the aorta estimated by M mode echocardiography on 15 patients with coronary disease undergoing right catheterization for diagnostic purposes. Cardiac output was calculated from stroke volume and heart volume using the PDE method as well as the Fick procedure for comparison. The mean value for the cardiac output via the PDE method (4.42 L/min) was only 6% lower than for the cardiac output obtained from the Fick procedure (4.69 L/min) and the correlation between the two methods was excellent (r=0.967, p less than .01). The good agreement between the two methods demonstrates that the PDE technique offers a reliable noninvasive alternative for estimating cardiac output, requiring no active cooperation by the subject. It was concluded that the Doppler method is superior to the Fick method in that it provides beat by beat information on cardiac performance.

Source record↗

Longitudinal study of astronaut health: Mortality in the years 1959-1991

We conducted a historical cohort study of mortality among 195 astronauts who were exposed to space and medical sources of radiation between 1959 and 1991. Cumulative occupational and medical radiation exposures were obtained from the astronaut radiation exposure history data base. Causes of death were obtained from obligatory death certificates and autopsy reports that were on file in the medical records. A total of 18 deaths occurred during the 32-year follow-up period for which the all-cause standardized mortality ratio (SMR) was 142 (95 percent confidence interval 84 225). There was one cancer death in the buccal cavity and pharynegeal ICD-9 rubric whose occurrence was significantly beyond expectation. Mortality for coronary disease was 59 percent lower than expected (2 deaths; SMR = 41; 95 percent confidence limit 5 147). The crude death rate for 10 occupationally related accidents was 400 deaths per 100,000 person-years, which is an order of magnitude greater than accidental death rates in mining industries. The SMR of 1027 for fatal accidents was significantly beyond expectation (14 deaths; 95 percent confidence limit 561 1723) and was similar to SMRs for accidents among aerial pesticide applications. The 10-year cumulative risk of occupational fatalities based on the exponential, Weibull, Gompertz, and linear-exponential distributions was 10 percent. Mortality from motor vehicle accidents was slightly higher than expected but was not significant (1 death; SMR = 145; 95 percent confidence limit 2 808). Radiation exposures from medical procedures accounted for a majority of cumulative dose when compared with space radiation exposures. The results of the study do not confirm the impression that astronauts are at increased risk of cancer, but this does not obviate the need for further study. Overall, it was found that astronauts are at a health disadvantage as a result of catastrophic accidents.

Peterson, Leif E.↗