At least 37 records · Page 2

Statistical Calibration and Validation of a Homogeneous Ventilated Wall-Interference Correction Method for the National Transonic Facility

Wind tunnel experiments will continue to be a primary source of validation data for many types of mathematical and computational models in the aerospace industry. The increased emphasis on accuracy of data acquired from these facilities requires understanding of the uncertainty of not only the measurement data but also any correction applied to the data. One of the largest and most critical corrections made to these data is due to wall interference. In an effort to understand the accuracy and suitability of these corrections, a statistical validation process for wall interference correction methods has been developed. This process is based on the use of independent cases which, after correction, are expected to produce the same result. Comparison of these independent cases with respect to the uncertainty in the correction process establishes a domain of applicability based on the capability of the method to provide reasonable corrections with respect to customer accuracy requirements. The statistical validation method was applied to the version of the Transonic Wall Interference Correction System (TWICS) recently implemented in the National Transonic Facility at NASA Langley Research Center. The TWICS code generates corrections for solid and slotted wall interference in the model pitch plane based on boundary pressure measurements. Before validation could be performed on this method, it was necessary to calibrate the ventilated wall boundary condition parameters. Discrimination comparisons are used to determine the most representative of three linear boundary condition models which have historically been used to represent longitudinally slotted test section walls. Of the three linear boundary condition models implemented for ventilated walls, the general slotted wall model was the most representative of the data. The TWICS code using the calibrated general slotted wall model was found to be valid to within the process uncertainty for test section Mach numbers less than or equal to 0.60. The scatter among the mean corrected results of the bodies of revolution validation cases was within one count of drag on a typical transport aircraft configuration for Mach numbers at or below 0.80 and two counts of drag for Mach numbers at or below 0.90.

Walker, Eric L.↗

Special Perturbations Using Back-Correction Methods of Numerical Integration

A new class of linear multistep methods for numerical integration of differential equations is reported that permits satellite computation solutions to be corrected at certain points in the past as the integration advances in time. Algorithms have been developed for the solution of both first- and second-order differential equations. The back correction method appears to be more efficient than classical methods when dominant and perturbing forces can be separated.

Feagin, T.↗

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using the Fixed Base Correction Method

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, and not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this report describes a Fixed Base Correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this Fixed Base Correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

Natalie D Spivey↗

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using Fixed Base Correction Method - IFASD 2019

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, but do not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this paper reports on a fixed base correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this fixed base correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

modal testing↗

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Base-Shake↗

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment plus 3 dB and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Winkel, James P.↗

Error correction method and apparatus for electronic timepieces

A method and apparatus for correcting errors in an electronic digital timepiece that includes an oscillator which has a 2 in. frequency output, an n-stage frequency divider for reducing the oscillator output frequency to a time keeping frequency, and means for displaying the count of the time keeping frequency. In first and second embodiments of the invention the timepiece is synchronized with a time standard at the beginning of the period of time T. In the first embodiment of the invention the timepiece user observes E (the difference between the time standard and the timepiece time at the end of the period T) and then operates a switch to correct the time of the timepiece and to obtain a count for E. In the second embodiment of the invention, the user operates a switch at the beginning of T and at the end of T and a count for E is obtained electronically.

Davidson, J. R.↗

Application of Pressure-Based Wall Correction Methods to Two NASA Langley Wind Tunnels

This paper is a description and status report on the implementation and application of the WICS wall interference method to the National Transonic Facility (NTF) and the 14 x 22-ft subsonic wind tunnel at the NASA Langley Research Center. The method calculates free-air corrections to the measured parameters and aerodynamic coefficients for full span and semispan models when the tunnels are in the solid-wall configuration. From a data quality point of view, these corrections remove predictable bias errors in the measurement due to the presence of the tunnel walls. At the NTF, the method is operational in the off-line and on-line modes, with three tests already computed for wall corrections. At the 14 x 22-ft tunnel, initial implementation has been done based on a test on a full span wing. This facility is currently scheduled for an upgrade to its wall pressure measurement system. With the addition of new wall orifices and other instrumentation upgrades, a significant improvement in the wall correction accuracy is expected.

Iyer, V.↗

Data pre-processing: Stratospheric aerosol perturbing effect on the remote sensing of vegetation: Correction method for the composite NDVI after the Pinatubo eruption

An operational stratospheric correction scheme used after the Mount Pinatubo (Phillipines) eruption (Jun. 1991) is presented. The stratospheric aerosol distribution is assumed to be only variable with latitude. Each 9 days the latitudinal distribution of the optical thickness is computed by inverting radiances observed in the NOAA AVHRR channel 1 (0.63 micrometers) and channel 2 (0.83 micrometers) over the Pacific Ocean. This radiance data set is used to check the validity of model used for inversion by checking consistency of the optical thickness deduced from each channel as well as optical thickness deduced from different scattering angles. Using the optical thickness profile previously computed and radiative transfer code assuming Lambertian boundary condition, each pixel of channel 1 and 2 are corrected prior to computation of NDVI (Normalized Difference Vegetation Index). Comparison between corrected, non corrected, and years prior to Pinatubo eruption (1989 to 1990) NDVI composite, shows the necessity and the accuracy of the operational correction scheme.

Vermote, E.↗

An Improved Ionospheric Correction Method for Wide-Area Augmentation Systems

A powerful approach for generating ionospheric corrections in wide area differential GPS applications has been developed, that can be applied to the Federal Aviation Administration's Wide Area Augmentation System (WAAS). This approach has been used to support ionospheric calibration for NASA's Deep Space Network and will be supporting real-time operations for global ionospheric specification and, possibly, single-frequency satellite altimeter calibration. It is a real-time, grid-based technique relying on a computationally efficient Kalman-type filter to produce accurate, smoothly varying ionospheric correction maps over the coverage area. Formal error maps are also computed, providing vertical delay errors over the WAAS grid, which are useful in integrity monitoring. This solution to the ionospheric correction problem is self-calibrating, since GPS transmitter inter-frequency biases are obtained as a by-product of the mapping procedure. This contrasts with other techniques in which bias values must be provided from some additional source.

Wide-Area↗

ACIX-Aqua: A Global Assessment of Atmospheric Correction Methods for Landsat-8 and Sentinel-2 Over Lakes, Rivers, and Coastal Waters

Atmospheric correction over inland and coastal waters is one of the major remaining challenges in aquatic remote sensing, often hindering the quantitative retrieval of biogeochemical variables and analysis of their spatial and temporal variability within aquatic environments. The Atmospheric Correction Intercomparison Exercise (ACIX-Aqua), a joint NASA – ESA activity, was initiated to enable a thorough evaluation of eight state-of-the-art atmospheric correction (AC) processors available for Landsat-8 and Sentinel-2 data processing. Over 1000 radiometric matchups from both freshwaters (rivers, lakes, reservoirs) and coastal waters were utilized to examine the quality of derived aquatic reflectances (ρ̂w). This dataset originated from two sources: Data gathered from the international scientific community (henceforth called Community Validation Database, CVD), which captured predominantly inland water observations, and the Ocean Color component of AERONET measurements (AERONET-OC), representing primarily coastal ocean environments. This volume of data permitted the evaluation of the AC processors individually (using all the matchups) and comparatively (across seven different Optical Water Types, OWTs) using common matchups. We found that the performance of the AC processors differed for CVD and AERONET-OC matchups, likely reflecting inherent variability in aquatic and atmospheric properties between the two datasets. For the former, the median errors in ρ̂w560 and ρ̂w664 were found to range from 20 to 30% for best-performing processors. Using the AERONET-OC matchups, our performance assessments showed that median errors within the 15–30% range in these spectral bands may be achieved. The largest uncertainties were associated with the blue bands (25 to 60%) for best-performing processors considering both CVD and AERONET-OC assessments. We further assessed uncertainty propagation to the downstream products such as near-surface concentration of chlorophyll-a (Chla) and Total Suspended Solids (TSS). Using satellite matchups from the CVD along with in situ Chla and TSS, we found that 20–30% uncertainties in ρ̂w490≤λ≤743nm yielded 25–70% uncertainties in derived Chla and TSS products for top-performing AC processors. We summarize our results using performance matrices guiding the satellite user community through the OWT-specific relative performance of AC processors. Our analysis stresses the need for better representation of aerosols, particularly absorbing ones, and improvements in corrections for sky- (or sun-) glint and adjacency effects, in order to achieve higher quality downstream products in freshwater and coastal ecosystems.

Nima Pahlevan↗

A fast viscous correction method for full-potential transonic wing analysis

An analysis of the transonic flowfield around a three-dimensional wing is carried out using a strip method. Attention is given to the boundary layer growth in the streamwise direction. A viscous correction technique is defined for the TWING code for solving the full potential equations. A viscous ramp at the base of a shock is superimposed on the boundary layer displacement thickness generated by an integral boundary layer method. A relationship is then obtained between the effective displacement thickness and a vertical component of the surface velocity, a transpirational boundary condition. The viscous correction is found to be unnecessary in weak shock conditions but gives a better shock position and pressure distribution in a strong shock condition when compared with data from an ONERA M6 airfoil and the Hinson and Burdges (1980) Wing A.

Lee, S. C.↗

Continental-Scale Validation of Modis-Based and LEDAPS Landsat ETM + Atmospheric Correction Methods

The potential of Landsat data processing to provide systematic continental scale products has been demonstratedby several projects including the NASA Web-enabled Landsat Data (WELD) project. The recent freeavailability of Landsat data increases the need for robust and efficient atmospheric correction algorithms applicableto large volume Landsat data sets. This paper compares the accuracy of two Landsat atmospheric correctionmethods: a MODIS-based method and the Landsat Ecosystem Disturbance Adaptive ProcessingSystem (LEDAPS) method. Both methods are based on the 6SV radiative transfer code but have different atmosphericcharacterization approaches. The MODIS-based method uses the MODIS Terra derived dynamicaerosol type, aerosol optical thickness, and water vapor to atmospherically correct ETM+ acquisitions ineach coincident orbit. The LEDAPS method uses aerosol characterizations derived independently from eachLandsat acquisition and assumes a fixed continental aerosol type and uses ancillary water vapor. Validationresults are presented comparing ETM+ atmospherically corrected data generated using these two methodswith AERONET corrected ETM+ data for 95 10 km10 km 30 m subsets, a total of nearly 8 million 30 mpixels, located across the conterminous United States. The results indicate that the MODIS-based methodhas better accuracy than the LEDAPS method for the ETM+ red and longer wavelength bands.

Atmospheric correction↗

New VIIRS DNB Stray Light Correction Method

The Day/Night Band (DNB) broadband (500-900nm) imager is one of the sensors in the Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the Suomi National Polar-orbiting Partnership (SNPP) and the NOAA-20 satellites, which are polar-orbiting and fly at about 830km above the surface of the Earth. Depending on the satellite location and the sensor viewing geometry, for a short period just before (or after) the satellite enters into (or emerges from) the shadow of the Earth, unwanted stray light, seemingly caused by the reflection of solar beam on the slightly exposed inner side of the leading (or trailing) nadir door, can enter the instrument and impose noticeable impacts to a narrow portion of DNB satellite images in every orbit. The impacted images can be modified to look normal, and the current DNB stray light correction algorithm empirically assigns corrections. There is also an alternative approach using image-processing techniques. Both methods rely mainly on the stray light impacted measurements. To simplify the approach and for better correction results, the new method presented in this paper incorporates the observed asymptotic nature of measurements surrounding the stray light impacted region by fitting to the drop off in sun light from day to night. The new method can be applied to the raw measurements in real-time, and it can help to advance our understanding of this special type of DNB stray light that happens over the polar regions

VIIRS↗

Displacement incrementation in non-linear structural analysis by the self-correcting method

The prediction of nonlinear structural behavior by the finite element method wherein buckling does not occur has received considerable attention and, with it, reasonable success has been achieved. However, the post-buckling problem has been less actively pursued probably because of the inherent numerical difficulties encountered. This note reviews very briefly the numerical methods currently being used for pre- and post-buckling analysis and presents a self-correcting approach based on load and displacement incrementation which is shown to be efficient, reliable, and easy to program. Numerical solutions are presented which demonstrate the effectiveness of the method.

Haisler, W. E.↗

LANDSAT-4 MSS Geometric Correction: Methods and Results

An automated image registration system such as that developed for LANDSAT-4 can produce all of the information needed to verify and calibrate the software and to evaluate system performance. The on-line MSS archive generation process which upgrades systematic correction data to geodetic correction data is described as well as the control point library build subsystem which generates control point chips and support data for on-line upgrade of correction data. The system performance was evaluated for both temporal and geodetic registration. For temporal registration, 90% errors were computed to be .36 IFOV (instantaneous field of view) = 82.7 meters) cross track, and .29 IFOV along track. Also, for actual production runs monitored, the 90% errors were .29 IFOV cross track and .25 IFOV along track. The system specification is .3 IFOV, 90% of the time, both cross and along track. For geodetic registration performance, the model bias was measured by designating control points in the geodetically corrected imagery.

Brooks, J.↗

Ground Vibration Testing at NASA Armstrong, Emphasizing on Passive Aeroelastic Tailored Wing Ground Vibration Test Using Fixed Base Correction Method

How does experimental mechanics contribute to aircraft aeroelastic airworthiness? The aviation community is always improving analysis and testing techniques to realize quicker, cheaper, reliable solutions. A ground vibration test (GVT) is conducted to identify structural mode shapes, frequencies, and damping values to validate analytical models used for flutter analysis, which shows whether a structure has acceptable aeroelastic flutter margins for airworthiness. The FLL recently conducted a GVT of the Passive Aeroelastic Tailored (PAT) Wing using an experimental modal technique called Fixed Base Correction (FBC). The GVT objective was to obtain the PAT wing modal characteristics to compare test results with finite element model (FEM) results for the tow-steered wingbox.

loads testing↗