Search NASA⌕ Search

SEARCH · Search NASA

Results for “Critical Benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Verification of MCNP Critical Benchmark Model of U233-COMP-THERM-004 [Slides]

The verification of U233-COMP-THERM-004 contributed to the LANL centralized repository that’s currently under development. Revisions made to the MCNP model were statistically significant. Magnitude of bias is relatively small in comparison to other uranium benchmark biases and thus will likely have not a significant effect on the USL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Analysis for a Criticality Benchmark [Slides]

This presentation discusses how KRUSTY was analyzed with LANL’s MCNP neutron transport code, Monte Carlo N-Particle. In the Monte Carlo method, neutrons are born in fission events and fly around the geometry having events (e.g., scatter, capture, fission, escape) according to the natural probabilities. “Natural probabilities” are given as neutron cross sections , which are measured and evaluated nuclear data. One of the goals of the benchmark project is to improve the nuclear cross sections (and the codes that use them). In this work, the response of interest is called k eff , which describes the neutron multiplication in a near critical system. Like most quantities, k eff is not measured directly; it is only inferred. In summation, MCNP results for k eff matched the measurements extremely well. The evaluated uncertainties are asymmetric and smaller than 0.00100 (e.g., + 0.00080 / – 0.00062). The largest uncertainties are due to alignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Analysis for a Criticality Benchmark [Slides]

This presentation discusses how KRUSTY was analyzed with LANL’s MCNP neutron transport code, Monte Carlo N-Particle. In the Monte Carlo method, neutrons are born in fission events and fly around the geometry having events (e.g., scatter, capture, fission, escape) according to the natural probabilities. “Natural probabilities” are given as neutron cross sections , which are measured and evaluated nuclear data. One of the goals of the benchmark project is to improve the nuclear cross sections (and the codes that use them). In this work, the response of interest is called k eff , which describes the neutron multiplication in a near critical system. Like most quantities, k eff is not measured directly; it is only inferred. In summation, MCNP results for k eff matched the measurements extremely well. The evaluated uncertainties are asymmetric and smaller than 0.00100 (e.g., + 0.00080 / – 0.00062). The largest uncertainties are due to alignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comprehensive review of photophysical parameters (ε, Φ f , τ s ) of tetraphenylporphyrin (H 2 TPP) and zinc tetraphenylporphyrin (ZnTPP) – Critical benchmark molecules in photochemistry and photosynthesis

Tetraphenylporphyrin (H 2 TPP) and zinc tetraphenylporphyrin (ZnTPP) are widely used benchmark molecules in diverse photochemical studies given facile synthetic access, rich visible-region spectra, and broad structural analogy to chlorophylls. Yet the literature values for each key photophysical parameter – the molar absorption coefficient (ε), fluorescence quantum yield (Φ f ), and also singlet excited-state lifetime (τ S ) – vary over an astonishing range. Here, a comprehensive literature review (~1940–September 2020) encompassing 871 publications is reported for these essential parameters. Each parameter is determined by measurement with distinct instrumentation and suffers idiosyncratic sources of error. The best values for H 2 TPP are ε = 460,000 cm -1 ·M -1 , Φ f = 0.090, and τ S = 12.8 ns in Ar- purged toluene (Φf = 0.070, τS = 9.9 ns in toluene in air); the best values for ZnTPP are ε = 560,000 cm -1 ·M -1 , Φf = 0.030, and τ S = 2.1 ns in Ar-purged toluene (Φ f = 0.029, τ S = 2.0 ns in toluene in air). The choice of values for such parameters has far-reaching consequences in photochemistry ranging from fluorescence (or Förster) resonance energy transfer (FRET) processes to assessments of molecular brightness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Status of the International Criticality Safety Benchmark Evaluation Project

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has continued its work generating evaluations of new and historical criticality benchmark experiments since the last update to the nuclear criticality safety community at the 11th International Conference on Nuclear Criticality Safety (ICNC 2019) in Paris, France. Three additional versions of the ICSBEP Handbook have been published since that update, and the Technical Review Group (TRG) held two in-person (in 2019 and 2023) and three virtual (2020 and 2021) meetings to review and approve additional benchmarks. The 2019 edition of the ICSBEP Handbook included five new evaluations with 79 new configurations, the 2020 version of the ICSBEP Handbook contained five new evaluations totaling 76 new configurations, and the 2021 version of the ICSBEP handbook contained five new evaluations with a total of 57 different configurations. The ICSBEP TRG met in October and December 2021, to review benchmarks for potential inclusion in the 2022 ICSBEP Handbook, with seven evaluations receiving provisional approval pending resolution of review group comments. Final comment resolution for some of these evaluations is currently underway and handbook publication should be completed soon. The ICSBEP TRG met again in person in April 2023 to review benchmarks for the 2023 ICSBEP Handbook, provisionally approving 7 new evaluations. The ICSBEP continues to deliver high-quality, peer reviewed evaluations of experiments relevant to the nuclear criticality safety community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of New MCNP6.3 Features for Critical and Subcritical Benchmark Simulations [Slides]

A separate MCNP6.3 V&V document reports on all the default calculations for all test suites was introduced. Here, we look at new optional features of the MCNP6.3 code. Then, Fission-matrix-based options with Convergence and population testing and Automated acceleration of the fission source and Doppler Broadening Resonance Correction and HDF5 Particle Track Output (PTRAC) and Validation benchmarks: criticality, Rossi-α, and subcritical multiplication. All the new MCNP6.3 options give statistically equivalent results and should be considered for default usage in criticality and subcritical multiplication calculation work. Discussed are two separate papers at the upcoming 2023 International Conference on Nuclear Criticality Safety (ICNC 2023) that give more details on the results presented here.

97 MATHEMATICS AND COMPUTING↗

Status of the International Criticality Safety Benchmark Evaluation Project

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has continued its work generating evaluations of new and historical benchmark experiments since the last update to the nuclear criticality safety (NCS) community at the 12th International Conference on Nuclear Criticality Conference held in 2023. One additional version of the ICSBEP Handbook has been published since that update, and the Technical Review Group (TRG) held two in-person meetings to review and approve additional benchmarks. The 2022 and 2023 editions of the handbook were combined into one release (published in November 2024) and contained 13 new evaluations with 46 different configurations and two major revisions to existing evaluations. The 2024 version of the handbook, currently under publication review, will contain two new evaluations with 15 new configurations and one major revision to HEU-MET-FAST-028, the evaluation of Flattop with a uranium core. The ICSBEP TRG met again in person in April 2025 to review benchmarks for the 2025 ICSBEP Handbook and final comment resolution is currently ongoing. Many of the new benchmarks represent contemporaneous experiments that have been specifically optimized to provide validation cases relevant to the NCS community. One major area of focus for new critical experiments is to target the sparsely populated intermediate energy (or resonance) region. Another focus of many of the new benchmarks is to provide experiments sensitive to different materials, such as chlorine, hafnium, tantalum, titanium, molybdenum, chromium, and polymethyl methacrylate (PMMA, or Lucite). The ICSBEP continues to deliver high-quality, peer reviewed evaluations of integral experiments relevant to the nuclear data community.

HEU-MET-FAST-028↗

Assessment of Existing Transportation Packages for Use with HALEU

Commercial light water reactor operators and fuel vendors in the United States are pursuing changes to fuel that include increased 235 U enrichment. Economic studies generally anticipate maximum near-term fuel assembly designs with up to 8 wt.% 235 U. Many next-generation nuclear reactor designs require high-assay low-enriched uranium (HALEU) (19.75 wt.% > 235 U > 5 wt.%) fuel. One necessary element for the commercial-scale use of HALEU is the ability to safely transport large quantities of enriched fuel material in multiple forms. However, there is uncertainty as to whether subcriticality requirements can be satisfied with existing package designs and whether existing critical benchmark experiment data are sufficient to support criticality safety code validation for HALEU transportation applications. This study assesses the potential to use currently licensed transportation packages for the transportation of increased enrichment unirradiated U fuel forms. The assessment uses selected package designs that represent the five categories of fuel form-boiling water reactor pins and assemblies, pressurized water reactor pins and assemblies, UF 6 , U-metal and tristructural isotropic (TRISO) particles, and UO 2 pellets or powder-and focuses on demonstrating subcriticality and identifying benchmark critical experiments appropriate for use in criticality computer code validation. Key quantities of interest that relate to subcriticality are limiting conditions (e.g., optimum moderation), package or package array k eff , package capacity, and package transportation array size. The SCALE TSUNAMI-3D and TSUNAMI Indices and Parameters codes are used for sensitivity and uncertainty calculations and for identification of candidate critical benchmark experiments for code validation. The primary metric for identifying candidate benchmarks is the similarity coefficient, c k . For each fuel form category, a representative package is evaluated. Results provided for each package evaluation include enrichment and packaging limits (e.g., maximum transportation array size as a function of enrichment) and benchmark critical experiment similarity coefficients. Results indicate that there are viable means for increasing enrichments into the HALEU range across the spectrum of fuel forms with differing increase amounts available for different packages. Sources of subcriticality margin to offset increased enrichment reactivity include reduced transportation array size, reduced fissile mass, burnable absorber credit, and safety analysis margin harvesting. For all packages except the DN-30, numerous critical benchmark experiment candidates for validation were identified.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resolved resonance region evaluations of n+ 206,207,208 Pb for fast spectrum applications

Resolved resonance region evaluations of the major isotopes of natural lead, 206 Pb, 207 Pb, 208 Pb, have been per formed to support the development of Generation IV reactors. In this study, validation of nuclear data for lead fast reactors was performed with simulations of shielding benchmarks, integral critical benchmarks, and quasi-differential scattering measurements. Sensitivity analyses of these systems showed that elastic scattering reactions above 100 keV were the dominant reactions driving system performance. The resolved resonance regions (RRRs) of the lead isotopes extend past 100 keV, making the RRR an ideal starting point to evaluate lead cross sections. Since the R-matrix requires knowledge of bound, distant, and observed resonances, it was necessary to evaluate from 10 -5 eV up to the respective limit of the RRR. The 208 Pb RRR evaluation was extended to 1.5 MeV in order to obtain resonance parameters used to calculate new elastic scattering angular distributions up to 1.5 MeV. Resonance parameter uncertainties and covariance were generated using the R-matrix code SAMMY. The new RRR parameters show a direct improvement to the scattering kernel below 1.5 MeV which in turn greatly improves fast critical experiments over ENDF/B-VIII.0.

206Pb↗

Criticality Experiments to Reduce Compensating Errors in Plutonium Nuclear Data

Compensating errors between nuclear data observables in a library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors in nuclear data. A new criticality experiment, described in this work, was designed with the specific target nuclear data of 239 Pu fission, inelastic scattering, elastic scattering, capture, nu-bar, and prompt fission neutron spectrum (PFNS). This work will focus on the design and execution of the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). The criticality experiment includes two different configurations with very different geometries: one is cube-like to minimize neutron leakage while the other is slab-like to maximize leakage. Having these two widely varying configurations allows the scattering sensitivities of 239 Pu to the neutron multiplication factor to be greatly changed while minimally impacting the other cross section sensitivities. Both configurations utilize the Pu ZPPR (Zero Power Physics Reactor) plates as fuel. The experiments were designed using a D-Optimality criteria, which is an optimization method minimizing the log-determinant of the adjusted nuclear data covariance for the target reactions. These experiments include not only inference of k eff , as done in all critical benchmark experiments, but several other responses as well, such as neutron multiplication measurements and reaction rate ratios. After analysis of the measured data is complete, adjustment of nuclear data will be performed to assess whether the new experimental data successfully reduced compensating errors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Updates to SNL Nuclear Criticality Safety Benchmark Suite for MCNP

Members of the Nuclear Criticality Safety (NCS) Program at Sandia National Laboratories (SNL) have updated the suite of benchmark problems developed to validate MCNP6 Version 2.0 for use in NCS applications. The updated NCS benchmark suite adds approximately 600 new benchmarks and includes peer review of all input files by two different NCS engineers (or one NCS engineer and one candidate NCS engineer). As with the originally released benchmark suite, the updated suite covers a broad range of fissile material types, material forms, moderators, reflectors, and neutron energy spectra. The benchmark suite provides a basis to establish a bias and bias uncertainty for use in NCS analyses at SNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated Godiva-IV Benchmark Preview

A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused keff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused $\kappa$ eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of HEU-Pb in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the average neutron energy the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. The lack of integral measurements to determine errors in Pb cross-section data has caused the latest nuclear cross-section libraries to over/underestimate k eff compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the CERBERUS Evaluation for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

Modeling & Simulation (M&S) tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers continue to improve, we are able to enhance resolution in our calculations. Therefore, the limitations of simulation capability are in the quality of data that is being used, including our ability to quantify the uncertainty and sensitivity of that data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. These experiments, along with differential measurements, can help improve the quality of nuclear data. Concerns regarding the accuracy of Cu nuclear data have been published. The large values and trend of C-E for the Zeus intermediate energy benchmark, being one of the primary examples. Furthermore, very few experiments have been designed to be sensitive to Cu (as shown in Figure 1), so an integral, critical experiment is needed to help resolve these differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL’s Continuing Efforts in Evaluating and Validating TSLs [Slides]

This presentation finds that INS measurements are not as variable based on sample composition, because phonon spectra is a properly of the bulk material. Additionally, INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. This presentation reasons that relaying solely on theoretical atomistic calculations for TSL evaluation is not enough, they are highly dependent on inter-atomic potentials (which are not the most accurate depending on the quantity trying to be reproduced) and evaluators knowledge and understanding of the material being studied. Finally on Critical benchmarks, while extremely useful for validation of nuclear data at all energies, critical benchmarks are not the best tool to provide a definitive answer on conflicting TSLs. The presentation concludes that INS and transmission measurements need to be the basis of validation of TSLs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗