Search NASA⌕ Search

SEARCH · Search NASA

Results for “Critical Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A model to assess Zircaloy’s mechanical property changes following a transient beyond critical heat flux

Maintaining the integrity of nuclear fuel rods is essential for ensuring public health and safety in nuclear power generation. During reactor operation, this integrity is confirmed by demonstrating compliance with established regulatory acceptance criteria. For moderate-frequency events, such as limiting transients and anticipated operational occurrences (AOOs), the current fuel integrity criterion is based on preventing boiling transition. This criterion assumes that prevention of boiling transition will prevent excessive cladding heating and, thus, fuel failure during normal operations. While conservative, this approach places significant constraints on core design, fuel cycle economics, and a plant’s ability to perform major power uprates, leading to suboptimal fuel utilization and inefficient carbon-free energy production. A more efficient approach could be achieved by revising the failure criterion to a material-specific limit rather than strictly preventing the boiling transition, since boiling transition per se is not a cause of fuel cladding failure. Here, as a result, a new licensing framework based on material properties, termed time-at-temperature (t@T), is needed. This approach would allow for brief periods of post–critical heat flux operation during an AOO without compromising safety. Implementing the t@T licensing strategy requires a robust technical foundation in material properties, which must be established through comprehensive data collection on both unirradiated and irradiated fuel and cladding materials. This foundation would enable the development of a safety basis that ensures safe operation while providing greater flexibility and efficiency for reactor operation. This paper documents a thorough review of the available data to establish a baseline knowledge that can inform the development of cladding mechanical models, as well as identify experimental data gaps that need to be addressed in future research. Machine learning and data informatics were utilized to extract the importance of parameters on the t@T parameter. Industry tools were used to perform baseline analyses to define the relevant transient conditions for data analysis. The subsequent review successfully identified applicable experimental data, as well as sufficient data to evaluate changes in cladding mechanical properties following an AOO transient. Rather than developing new models, this work coupled existing irradiation annealing and recrystallization models to calculate changes in hardness, yield stress, and ultimate tensile stress following an AOO event. The findings from this review were summarized to highlight the experimental data needs required to fill remaining gaps and support the development of future t@T licensing methodologies.

Cladding performance↗

Sensitivity analysis of in-pile critical heat flux experiments in TREAT for characterization of RIA power-transient effects

A reactivity-initiated accident (RIA) is one type of postulated design basis accident (DBA) that can cause a departure from nucleate boiling (DNB) event in pressurized-water reactors (PWRs). A DNB occurrence and its consequences depend on the thermophysical properties of the fuel components and coolant, characteristics of the transient energy insertion into the fuel rod, and the onset of the critical heat flux (CHF) phenomenon. To leverage the restart of the Transient Reactor Test (TREAT) Facility, an effort is currently underway to better understand the cladding-to-coolant heat transfer mechanisms and the CHF phenomenon under fast-transient irradiation conditions. This paper characterizes the impact of power transients on the thermal-hydraulic behavior of a TREAT Facility reactor heater rodlet CHF experiment to provide the priority of parameters that need to be investigated for an improved CHF model. Sobol sensitivity analysis methods and the Reactor Excursion and Leak Analysis Program (RELAP5-3D) code were used to identify key input parameters on the uncertainty in the prediction of peak outer- and inner-surface temperatures of the heater tube, as well as the time of the DNB event. A series of sensitivity analyses revealed the total energy deposition on the tube and the transient effects of power pulse had large impacts on the maximum temperatures. The CHF multiplier had the largest impact on the time occurrence of CHF. The overall results show the energy deposition rate in the tube is the most influencing factor to the manifestation of CHF and the resulting thermal-hydraulic behaviors of the tube. The multiplier for the CHF, which is interpreted as the predicted CHF value, has the largest Sobol indices for the time of the CHF in all cases, since it directly determines the occurrence of CHF. It is inferred that the uncertainties in the thermal-hydraulic behaviors of fuels increase with respect to the key parameters as the power pulse becomes broader, and an accurate estimation of the energy deposition rate is required to reduce the uncertainty in the evaluation of the integrity of fuel if the CHF is expected to occur near the peak power. Therefore, the outputs are expected to provide rigorous interpretation of ongoing in-pile CHF experiments in the TREAT Facility reactor regarding thermal-hydraulic behavior of the fuel system aiming for a new transient in-pile CHF model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ion irradiation effects on Cr-coated zircaloy-4 surface wettability and pool boiling critical heat flux.

The concept of coating the currently used nuclear fuel cladding (zirconium-based alloy, typically Zircaloy-4 or Zirc-4) with an oxidation preventive layer is a progressing Accident tolerant Fuel (ATF) candidate alloys. The coated Zirc-4-based alloys could be a solution to suppress undesirable fast reaction kinetics with high-temperature steam. Zirc-4 has been the most preferred cladding material in pressurized water reactors (PWRs). Chromium (Cr) based alloys as a coating material provides excellent corrosion protection and good strength and wear resistance. In this paper, we present the surface wettability measurements and pool boiling Critical Heat Flux (CHF) for Cr-coated Zirc-4 claddings pre- and post-exposure to an ion irradiation environment. The wettability measurements, including static contact angle (contact angle, θ) and average surface roughness (surface roughness, Ra), are introduced for samples of different coating thicknesses (5–30 μm thick). The coatings fabricated by the cold spray of Cr-Al particles to 10 mm × 10 mm × 1.95 mm Zirc-4 substrates. Post fabrication, a Pilgering (cold rolling) process, was applied to finalize the coating thickness and resulted in a significant reduction in surface roughness of initially fabricated rough surfaces. The process produced three distinguished samples 5-μm unpolished (as machined), 5-μm, and 30-μm polished (cold rolled). The measurements are presented for the three surfaces and bare Zirc-4 as a baseline surface. The contact angle analyses were implemented in theoretical models from the literature to predict pool boiling CHF. Pool boiling experiments were conducted to measure the pool boiling CHF values and compare them to the predicted values. Scanning Electron Microscope (SEM) images and Energy Dispersive X-ray Spectroscopy (EDS) analysis was performed to characterize the surfaces for better understanding and interpreting the results. The SEM images showed localized surface damage due to ion irradiation. No recognized change in the measured surface roughness due to ion irradiation. The contact angles of irradiated Cr-coated surfaces are consistently higher (10°) than pre-irradiated surfaces. Decreasing the Cr-coating layer thickness resulted in lower contact angle pre- and post- ion irradiation. The predicted pool boiling CHF using the Kandlikar model is in good agreement with the experimentally measured CHF values within ±12% for all samples.

36 MATERIALS SCIENCE↗

A novel approach for critical heat flux enhancement during severe accident mitigation with removal of radioactive materials from the coolant

In this paper, a new system, which consists of mature and proven technologies, is suggested for simultaneous objectives in nuclear power plants: CHF enhancement and effective decontamination. It consists of multifunctional magnetic nanoparticles and a collector part. CHF enhancement for severe accident mitigation strategies like IVR-ERVC and core catcher is expected along with an efficient decontamination process of target radioactive nuclides, and through the collector part, where external magnetic fields are applied, working fluid can be effectively purified. The multifunctional magnetic nanoparticle possesses potentials to severe accident scenarios based on its distinct characteristics. Also, a nanofluid system is strongly affected by environments and state of the immersed particles; the CHF enhancement can be stably achieved in real applications with proper consideration and optimization.

Kam, Dong Hoon↗

Hybrid Improved Empirical Mode Decomposition and Artificial Neural Network Model for the Prediction of Critical Heat Flux (CHF)

Three Hybrid artificial neural network (ANN) models namely radial basis function (RBF), generalized regression neural networks (GRNN), and multi-layer perceptron (MLP) combined with empirical mode decomposition (EMD) are developed for CHF predictive modelling using CHF experimental databases.First, the original experimental inputs data series are decomposed into several intrinsic mode functions (IMFs) and one residual by EMD, whose components are divided into high, medium and low components. The performance parameters of the hybrid models indicates that the root mean square error (RMSE) are 0.8831, 0.6522, and 0.4149; the mean absolute error (MAE) are 0.6697, 0.4636, and 0.1935. The values of the R-square of the developed prediction approach utilizing EMD-RBF, EMD-GRNN, and EMD-MLP models are 0.8553, 0.9302, and 0.9818, and the index of agreement are 0.9464, 0.9700, and 0.9894., The value of the R-square and the index of agreement of the proposed models are much higher than those of the simple models .The Pearson's test results show that the association strength between the measured and the predicted values of the proposed model EMD-MLP is the strongest. These results show the following: (a) compared with other related, recent studies, the prediction accuracy of the hybrid model EMD- MLP proposed in this research is the best hybrid model; (b) the proposed hybrid model (EMD-MLP) attains superior performance compared with simple models.

Djeddou, Messaoud↗

Enhanced Models for the Simulation of Two-Phase Boiling Flow and Critical Heat Flux with the STAR-CCM+ and NEK-2P CFD Codes: Executive Summary (Final Report)

The goal of the project was to develop, verify and validate an advanced two-phase boiling flow modeling capability that enhances the existing two-phase flow modeling of the STAR-CCM+ Computational Fluid Dynamics (CFD) code. The project focused on the simulation of two phase flow and heat transfer phenomena that occur in Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) fuel bundles under various operating conditions. The extended STAR-CCM+ two-phase flow models implemented during the project follow the approach similar to the Extended Boiling Framework [1-6] previously developed at Argonne but include more fundamental physical models of boiling phenomena. The development and validation of the extended two-phase models is supported by the U.S. DOE GAIN program and performed in collaboration with Framatome U.S. Inc.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental investigation of power transient flow boiling

To advance the mechanistic understanding of power transients in flow boiling, experimental investigations are performed to capture the thermal response of four different kinds of cladding materials, including FeCrAls, to Fuchs reactivity initiated accident transients and linear ramp power transients. The transition boiling regime is phenomenologically reflected in power-transient flow boiling, which is different from steady-state boiling. In light of this, the critical heat flux that is usually featured with temperature overshooting does not indicate thermal safety margin of cladding materials as conservatively as the maximum heat flux, which is greater than critical heat flux in the power transient boiling curve. This is physically attributed to the thermal energy deposition on the cladding wall. In addition, the thermal energy released from the cladding wall results in different boiling heat transfer coefficient for the decreasing and increasing power stages respectively during the Fuchs power transient. The maximum heat flux difference gap, which appears due to changes in cladding materials and transient time scales, is appreciable under an intermediate heat convection regime. However, this difference gap is gradually weakened by the progressive increasing of mass flux and/or inlet subcooling due to the enhanced dominance of heat convection over heat conduction. Finally, the small difference gap of maximum heat flux is found to be insignificant under the weak heat convection because of power transient induced annular flow instability.

42 ENGINEERING↗

A knowledge gap analysis for transient CHF prediction within RELAP5-3D

Here we compare several experimental pool and flow boiling critical heat flux experiments with corresponding computational models developed with RELAP5-3D. Encompassed within this paper are several sensitivity analyses for the boiling heat transfer correlations, critical heat flux (CHF) prediction within RELAP5-3D and the thermal properties of the cladding for experiments in the Transient Reactor Test Loop (TRTL) and Transient Reactor Test (TREAT) facilities. The sensitivity analyses were consistent in determining that there is a large contribution from the critical heat flux multiplier which in this application, accounts for the effects of power transient critical heat flux. Comparison to experimental results of both the TREAT CHF-SERTTA experimental campaign and a University of New Mexico (UNM) pool boiling experimental campaign demonstrate both the under-prediction of transient CHF and nucleate boiling heat transfer. To address the gaps in knowledge regarding the transient heating effect for both boiling heat transfer and CHF prediction, we present an experimental test matrix for the TRTL facility that will isolate the power transient effect under PWR relevant operational conditions. The test matrix will incorporate 6 power pulses with a constant energy deposition and a timescale that spans over several orders of magnitude, including a steady state test with an exponential period of 10 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Design of separate-effects In-Pile transient boiling experiments at the $\mathrm{TREAT}$ Facility

The cladding-to-coolant heat transfer during rapid power excursions, such as reactivity-initiated accidents, remains a crucial area of uncertainty in nuclear reactor safety. This uncertainty impacts the ability to accurately predict fuel performance behavior for these conditions. Improving our understanding of transient cladding-to-coolant heat transfer will enhance our ability to model design basis accidents and could increase design and improve safety margins for the current commercial fleet and advanced reactors. To address these issues, the Critical Heat Flux Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA) experiment uses a novel approach with a borated stainless-steel heater rodlet that can replicate cladding temperatures experienced during a design-basis reactivity-initiated accident. The rodlet and experiment is instrumented to provide temperature and thermal-hydraulic conditions throughout the transient. The design of the rodlet allows for separate effect testing that eliminates complexities with a fuel and cladding specimen. We report the experiments have provided data that will be used to improve our understanding of boiling behavior, specifically critical heat flux, under transient conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced Pool Boiling of Low-Pressure Refrigerants on Round Tubes- An Experimental Evaluation

Pool boiling heat transfer is one of the most effective heat transfer methos and crucial for several energy conversion processes such as electronic cooling, steam generation, water purification and thermal management. Enhancing boiling heat transfer around the tubes enables higher heat flux, which can improve the efficiency and lead to compact heat exchangers. Delaying the onset of critical heat flux (CHF) allows for higher CHFs and protects equipment during anomalous transient conditions. Growing interest in process intensification and delayed CHF has motivated the current study. An experimental approach has been deployed to investigate a potential technique to enhance the pool boiling performance around small diameter tubes by open cell metal foams. The findings for nucleate pool boiling of Novec HFE 7000 on the externally enhanced and smooth tubes are reported. The enhanced tube comprised of compressed aluminum foam brazed around. All the samples were horizontally oriented, and the experiments were performed under ambient pressure conditions. The heat transfer measurements for the smooth tubes were compared with several existing correlations and established the baseline. The preliminary results showed that the aluminum foam effectively enhanced the heat transfer coefficient and delayed the onset of critical heat flux. In addition, the pool boiling process around the round tube sample was visualized from both side and front views to comprehend the heat transfer mechanisms underlying substantial enhancement observed during experiments.

Yang, Cheng-Min↗