Search NASA⌕ Search

SEARCH · Search NASA

Results for “Crossflow Filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Solid–liquid separation of lignocellulosic sugars from biomass by rotating ceramic disc filtration

In many biomass conversion processes, the separation of cellulosic sugars from residual, lignin-rich solids is a critical step, and achieving high recovery yields of sugars by conventional tangential crossflow and vacuum filtration is challenged by the presence of biomass solids, which rapidly foul filters, resulting in decreased throughput. Considering the performance limitations of traditional filtration methods, dynamic filtration, which generates high shear at the membrane surface to decrease fouling, is emerging as a viable alternative for demanding solid–liquid separations. For high solids separations, there is little available information regarding the performance, limitations, and energy consumption of dynamic filtration. To that end, here we characterized the performance of a dynamic filtration module, specifically a rotating ceramic disc (RCD) filter, for the aseptic recovery of cellulosic sugars from biomass solids following pretreatment and enzymatic hydrolysis. We show how RCD rotational velocity and percent biomass solids impact the filter throughput. Additionally, we used computational fluid dynamics (CFD) simulations to estimate the shear rate at the membrane surface and to visualize hydrodynamic profiles within the module. With the combined CFD simulations and experimental results, we estimated the energy demand and operating expenses for a viable dynamic filtration system operating with a lignocellulosic feed slurry. Our results indicate that an RCD filter can achieve ≥95% recovery of sugars and produce a retentate slurry containing 12 wt% insoluble solids with low energy consumption (a 2.2-fold improvement over cross-flow filtration) and low operating costs ($\$$0.06 per kg sugars). These results show a viable path towards operationally reliable, energy efficient, and cost-effective separations of sterilized cellulosic sugars from biomass solids and highlight the potential of dynamic filtration systems for challenging solid–liquid separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable aqueous-phase fabrication of reduced graphene oxide nanofiltration membranes by an integrated roll-to-roll (R2R) process

Economic fractionation of multicomponent biomass-derived streams is a key challenge in biobased fuels and chemicals production. Kraft black liquor (BL) is generated at ~1 billion tons/yr globally from biomass pulping and contains ~15wt% total solids including lignin, hemicellulose fragments, and inorganics. Membrane-based BL concentration is attractive but challenged by low solute rejections and poor stability in BL, which combines alkaline pH (~13), high dissolved solids content (15+ wt%) and high temperature (70–85°C). Here we discuss the scaled fabrication and characterization of reduced graphene oxide (rGO) nanofiltration membranes by slot die coating on a roll-to-roll (R2R) with integrated vacuum filtration. Here, we obtain high-quality 90×30 cm rGO membranes (referred to as “R2R-rGO membranes” in this work) with ~100 nm average thickness supported on porous poly(ethersulfone) (PES) sheets, and an effective area of 2700cm 2 . We present characterizations of their microstructure and uniformity as mapped over large areas by scanning electron microscopy (SEM), ellipsometry, adhesion test and X-ray photoelectron spectroscopy (XPS). The constructed ellipsometry model for the rGO membrane/PES substrate composite was successfully applied to 48 different locations of the R2R-rGO membranes. The R2R-rGO membranes showed >98% lignin rejection with a steady state flux of ~12 LMH at 50bar in a 15.7wt% total solids (TS) kraft BL stream at 72°C and 2–3 gal/min crossflow rates. Slot die coating on a R2R platform with integrated vacuum filtration can enable rapid fabrication of high-quality GO membranes at scale without organic solvents or volatile organic compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filtration of Hanford Tank AP-107 Supernatant

Bench-scale filtration testing of 9.5 liters of 241-AP-107 supernatant was conducted using two different crossflow filters (CFFs) and two different dead-end filters (DEF) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. The following filters were tested: Mott CFF Model 7610 (media grade 5); Mott CFF Model 7610 (media grade 0.1); Mott inline filter Model 6480 (media grade 5) (also known as the backpulsed dead-end filter, BDEF); and, Mott 70-mm disc filter (media grade 0.1) (also known as the dead-end filter, DEF) The CFFs were tested in the cells unit filter (CUF) system in recycle mode and the DEFs (in-line and disc) were used to dewater the feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deployment of large tank monosodium titanate strike to increase salt processing at the Savannah river site - 15115

The treatment of high level waste (HLW) salt solutions using the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU) began at Savannah River Site (SRS) in 2008. Since that time, over 6 million gallons of liquid HLW have been treated and the resulting low level waste (LLW) effluent immobilized in cementitious grout at salt-stone. In addition to the continued stabilization of liquid HLW, operating experience from the ARP/MCU facilities has also been valuable in considering the design and construction of the Salt Waste Processing Facility (SWPF) which will utilize similar unit operations on a much larger scale. ARP removes actinides by contacting waste with monosodium titanate (MST) which is a solid adsorbent for soluble strontium and actinides. Once the sorption reaction is complete, the MST solids are separated from salt solution via ultrafiltration through a crossflow filter. The throughput of initial operations of ARP/MCU was limited by the flowrate through the extraction process. However, after the implementation of a new solvent flowsheet, filtration of MST will be the rate limiting step in salt processing. For the entirety of ARP/MCU operation, Savannah River Remediation (SRR) has sought to improve process efficiency and performance through optimization and modification of the original facility design. These efforts have resulted in a best-single-year throughput of 4.9 million liters of decontaminated salt solution. In keeping with these practices, SRR recently initiated a project to improve filtration throughput by relocating the MST strike from small batches immediately upstream of the filtration unit to the underground waste tank used to batch and store salt solution feed for ARP/MCU. This process change will allow the bulk of MST solids to decant in the waste tank prior to filtration which should improve both the nominal operational filter flux as well as the achieved utility of filter operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MST Filterability Tests

The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRR was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO 2 , and NaNO 3 ) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mineral Scale Formation during Crossflow Reverse Osmosis at Constant Flux and Constant Transmembrane Pressure Conditions

Mineral scale formation on membrane surfaces is a significant challenge in reverse osmosis water purification. Laboratory fouling experiments are typically run such that the transmembrane pressure (TMP) is fixed, and the permeate flux decreases over time as scales accumulate on the membrane surface. However, this change in flux means that the hydrodynamic conditions at the membrane surface are continuously changing, which could affect crystallization and foulant deposition processes. Operating under constant permeate flux conditions, in contrast, is advantageous because it keeps the hydrodynamic conditions relatively consistent, making it possible to compare how membrane properties (e.g., surface chemistry) affect fouling propensity. Industrial reverse osmosis operations are not run strictly in either constant TMP or constant flux mode; while they may start at a constant TMP, feed pressure may be periodically adjusted to maintain permeate water production within a specified range. Here, the scarcity of constant permeate flux reverse osmosis scaling experiments reported in the literature frustrates efforts to compare membrane fouling processes under constant TMP and constant flux conditions. For the first time, the evolution of the fouling layer resistance was compared as a function of cumulative permeate volume per membrane area during constant TMP and constant flux reverse osmosis filtrations. Scaling experiments were conducted by challenging commercial reverse osmosis membranes with a model feed solution nearly saturated with calcium sulfate dihydrate (gypsum). At low fluxes, the increase in fouling layer resistance was quantitatively similar for the two operational modes. In contrast, at high fluxes, the fouling layer resistance increased more rapidly in constant flux filtration than in constant TMP filtration. The mechanism of scale formation in constant TMP and constant flux operation was self-limiting and self-reinforcing, respectively.

36 MATERIALS SCIENCE↗

Resource Recovery and Environmental Protection in Wyoming’s Greater Green River Basin Using Selective Nanostructured Membranes (Final Report)

Produced water (PW) represents a sizable waste stream that is co-generated with oil and natural gas production. In 2021 Wyoming ranked 8th and 9th, respectively in domestic oil and natural gas production. In 2017 Wyoming ranked as the 4th highest generator of PW in the U.S, accounting for 7% of the total volume generated. In the context of being the 3rd most arid state in the U.S., the value of water reuse becomes obvious. PW reuse, and resource recovery, in any form requires some level of treatment to remove particulates, residual (free, dispersed) hydrocarbons, organics, and salts. The level of treatment depends on the requirements of the reuse, or resource recovery, application. PW management systems in Wyoming employ in order of volume of PW managed the following management strategies: reinjection for enhanced oil recovery, surface discharge, deep well injection, evaporation ponds (impoundments), and commercial management/treatment. Complicating treatment efforts are the relatively high concentrations of organics (natural and synthetic), dispersed/free hydrocarbons, benzene-toluene-ethylbenzene, and xylenes (BTEX) compounds, biologicals, salts, and minerals. Hydrocarbons (dispersed/dissolved crude oils) and BTEX compounds, as well as synthetic organics, present economic and environmental concerns. The former represents lost revenue, while the latter results in negative environmental impacts like emissions from surface impoundments. The overall objective of this proposal was to synthesize superhydrophilic/oleophobic and superhydrophobic/oleophilic membranes for selectively concentrating and then separating BTEX compounds and oil and grease (O&G) from PW originating from the Greater Green River Basin (GGRB) in Wyoming. Three specific research aims were pursued to accomplish this overall objective. This final report details the development of the superhydrophobic and superhydrophilic membranes, as well as the design of the membrane module prototypes specifically. The technoeconomic assessment is separately reported in another document. 1. Aim #1 – Material optimization and performance evaluation of superhydrophilic/oleophobic and superhydrophobic/oleophilic membranes made by electrospinning/spraying. 2. Aim #2 – Design and construction of cross-flow membrane modules for selectively concentrating and then separating BTEX/oil from GGRB produced water. 3. Aim #3 – Techno-economic assessment of BTEX/oil recovery, and clean water production, using superhydrophilic/oleophobic and superhydrophobic/oleophilic membrane separation for GGRB PW. Superhydrophobic membranes were synthesized by electrospinning poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) nanofibers onto polyester (PET) substrates and electrospraying nano-carbon black/PVDF-HFP onto the nanofibrous layer. These membranes were characterized by high (>8000 liters per square meter per hour per bar (LMH/bar)) permeance values for pure hydrocarbon phases and a high hydrocarbon selectivity (>96%) when treating GGRB PW. All results were obtained when operating the membrane in a crossflow configuration representative of actual field operating conditions. Solvent/oil properties, specifically viscosity and total surface energy/tension, affected permeance across the membrane, which resulted in light mineral oil (394 LMH/bar) and o-xylene (1834 LMH/bar) being characterized by lower permeance values in the pure phase tests. Mixed phase fluxes between 40 to 80 LMH were obtained for the PW when operating the membrane at a feed pressure of 0.3 bar. Flux decreased as the mixed phase concentration in the feed decreased pointing to the importance of maximizing the collision efficiency between the emulsion and the membrane surface and maximizing the emulsion concentration in the feed and the turbulence within the feed channel. These tests demonstrated that the superhydrophobic membranes developed here are a viable hydrocarbon recovery method for GGRB PWs and should be pursued for testing in pilot-scale trials. Superhydrophilic membranes were successfully synthesized via electrospinning/spraying using polyacrylonitrile (PAN) nanofibers as a base nanofibrous matrix. Integration of polyaniline (PANI) into the nanofibrous matrix produced a superior membrane, for water filtration applications, relative to PAN alone and reduced graphene oxide (RGO) when integrated into the nanofibrous matrix. This conclusion was based on the PANI-PAN resistance to flux loss (fouling) when treating model solvent/oil solutions representative of GGRB PWs and field collected PW from the GGRB. The synthesized PAN membranes outperformed a commercially available PAN membrane designed for oil/water separation. This finding indicates that the surface chemical and physical characteristics of the electrospun membranes presents improved properties for filtration of challenging waters like GGRB PWs. The electrospun membranes therefore show promise overall as a substitute for conventionally polymerized membranes in PW treatment applications. The PANI-PAN membrane specifically presents superior performance characteristics for concentration O&G prior to treatment by the hydrocarbon recovery membrane and producing high-quality filtrate for reuse and/or additional treatment (desalination).

02 PETROLEUM↗