Search NASASearch

SEARCH · Search NASA

Results for “Cryogenic Material Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

578 records · Page 2

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Cryocooler

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Zero boil-off

Thermoplastic Matrix Composite Design for Cryotanks Using Multiscale Modeling and Bayesian Optimization

Designing lightweight, robust cryogenic storage tanks is critical for future launch vehicles, in-space propellant storage, and hydrogen powered aircraft. This work presents a multiscale modeling and Bayesian optimization framework for the design of thermoplastic matrix composite cryotanks. Molecular dynamics simulations are first used to determine temperature-dependent constituent properties for candidate thermoplastic matrices, which are homogenized to the lamina scale using NASA’s Multiscale Analysis Tool (NASMAT). These lamina properties, in combination with laminate family generation rules, are evaluated in HyperX structural optimization software to identify stacking sequences that meet all cryogenic load requirements. A Bayesian optimization framework is applied, with HyperX in the loop (via the HyperX API) to efficiently search across material and laminate design variables, yielding an optimized cryotank configuration with significant reductions in design cycle time compared to exhaustive search approaches.

thermoplastics

Initial Test Firing Results for Solid CO/GOX Cryogenic Hybrid Rocket Engine for Mars ISRU Propulsion Applications

ORBITEC is developing methods for producing, testing, and utilizing Mars-based ISRU fuel/oxidizer combinations to support low cost, planetary surface and flight propulsion and power systems. When humans explore Mars we will need to use in situ resources that are available, such as: energy (solar); gases or liquids for life support, ground transportation, and flight to and from other surface locations and Earth; and materials for shielding and building habitats and infrastructure. Probably the easiest use of Martian resources to reduce the cost of human exploration activities is the use of the carbon and oxygen readily available from the CO2 in the Mars atmosphere. ORBITEC has conducted preliminary R&D that will eventually allow us to reliably use these resources. ORBITEC is focusing on the innovative use of solid CO as a fuel. A new advanced cryogenic hybrid rocket propulsion system is suggested that will offer advantages over LCO/LOX propulsion, making it the best option for a Mars sample return vehicle and other flight vehicles. This technology could also greatly support logistics and base operations by providing a reliable and simple way to store solar or nuclear generated energy in the form of chemical energy that can be used for ground transportation (rovers/land vehicles) and planetary surface power generators. This paper describes the overall concept and the test results of the first ever solid carbon monoxide/oxygen rocket engine firing.

Eric E Rice

Conclusions of a Cryogenic Motor Configuration Study for Aircraft Propulsion

Cryogenic electric machines are a promising technology for multi megawatt electric aircraft drivetrains. Superconducting stators that make use of low AC loss superconducting wires are considered to be a key component for these cryogenic machines. This paper shares the lessons learned from a design study that evaluated several configurations of a 5 MW cryogenic motor for this application. The lessons are drawn from a qualitative study of 16 configurations and a quantitative study of 8 down selected configurations. The quantitative study involved using analytical calculations (electromagnetic, thermofluid, mechanical, and motor sizing) to determine each configuration’s Pareto front of total efficiency and total specific power. The conclusions from a preliminary assessment of different stator conductors (superconductors and cryogenic metals) are also presented. One motor configuration is down selected for future detailed design and demonstration at the multi megawatt level.

Electrified aircraft propulsion

NASA Interests in Superconducting and Cryogenic Technology

NASA develops and operates technology for a wide range of applications and environments across its aeronautics and space portfolios. This presentation will summarize the applications and environments where superconducting technology and associated cryogenics are contributing to NASA’s missions and areas where there is an opportunity to expand the contribution. Important characteristics of high priority space environments will be discussed. An emphasis will be placed on aircraft propulsion and NASA’s Artemis mission (a Moon to Mars initiative). The discussion of space applications will include takeaways from NASA’s recent rankings of 187 space technology “shortfalls”. The aircraft propulsion application will be described in detail and existing NASA investments will be summarized.

Electrified Aircraft Propulsion

Cryogenic Propellant Tank Drain Simulation with a Stratified Ullage Nodal Model

Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.

Richard G Hibbs

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 – 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

Reaction Control System

Numerical Modeling of the Transient Chilldown Process of a Cryogenic Propellant Transfer Line

Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.

Temperature Sensors

A Cryogenic Seven-Element HEMT Front End for DSS 13

A cryogenically cooled Ka-band (33.6-GHz), seven-element front-end array for the DSN was built and tested. This system uses seven high electron mobility transistor (HEMT) low-noise amplifiers cooled by a two-stage closed-cycle refrigerator. All system components from the polarizers to the output isolators are cooled to a physical temperature between 18 and 35 K. The noise temperatures of the individual elements range from 64 to 84 K over a 2.75-GHz bandwidth.

J Bowen

Heat Transfer Enhancement in Cryogenic Quenching Process

This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.

two-phase flow

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil

Comparison of Cryogenic Flow Boiling in Liquid Nitrogen and Liquid Hydrogen Chilldown Experiments

This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.

Cryogenic Heat Transfer Coefficient