Search NASA⌕ Search

SEARCH · Search NASA

Results for “Crystallography and Scattering Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Substrate orientation effects on the nucleation and growth of the M{sub n+1}AX{sub n} phase Ti{sub 2}AlC

The M{sub n+1}AX{sub n} (MAX) phases are ternary compounds comprising alternating layers of a transition metal carbide or nitride and a third ''A-group'' element. The effect of substrate orientation on the growth of Ti{sub 2}AlC MAX phase films was investigated by studying pulsed cathodic arc deposited samples grown on sapphire cut along the (0001), (1010), and (1102) crystallographic planes. Characterization of these samples was by x-ray diffraction, atomic force microscopy, and cross-sectional transmission electron microscopy. On the (1010) substrate, tilted (1018) growth of Ti{sub 2}AlC was found, such that the TiC octahedra of the MAX phase structure have the same orientation as a spontaneously formed epitaxial TiC sublayer, preserving the typical TiC-Ti{sub 2}AlC epitaxial relationship and confirming the importance of this relationship in determining MAX phase film orientation. An additional component of Ti{sub 2}AlC with tilted fiber texture was observed in this sample; tilted fiber texture, or axiotaxy, has not previously been seen in MAX phase films.

36 MATERIALS SCIENCE↗

Oxygen vacancy ordering within anion-deficient Ceria

The structural properties of anion deficient ceria, CeO{sub 2-{delta}}, have been studied as a function of oxygen partial pressure, p(O{sub 2}), over the range 0>=log{sub 10p}(O{sub 2})>=-18.9 at 1273(2) K using the neutron powder diffraction technique. Rietveld refinement of the diffraction data collected on decreasing p(O{sub 2}) showed increases in the cubic lattice parameter, a, the oxygen nonstoichiometry, delta, and the isotropic thermal vibration parameters, u{sub Ce} and u{sub O}, starting at log{sub 10p}(O{sub 2}){approx}-11. The increases are continuous, but show a distinct kink at log{sub 10p}(O{sub 2}){approx}-14.5. Analysis of the total scattering (Bragg plus diffuse components) using reverse Monte Carlo (RMC) modelling indicates that the O{sup 2-} vacancies preferentially align as pairs in the <111> cubic directions as the degree of nonstoichiometry increases. This behaviour is discussed with reference to the chemical crystallography of the CeO{sub 2}-Ce{sub 2}O{sub 3} system at ambient temperature and, in particular, to the nature of the long-range ordering of O{sup 2-} vacancies within the crystal structure of Ce{sub 7}O{sub 12}. - Graphical abstract: Partial radial distribution function for oxygen vacancies within CeO{sub 1.710} at 1273 K (solid line) showing the increased tendency for local ordering in <111> directions compared to a random distribution (dashed line).

36 MATERIALS SCIENCE↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Combination of X-ray crystallography, SAXS and DEER to obtain the structure of the FnIII-3, 4 domains of integrin α6β4

The structure of the FnIII-3, 4 region of integrin β4 was solved using a hybrid approach that combines crystallographic structures, SAXS, DEER and molecular modelling. The structure helps in understanding how integrin β4 might bind to other hemidesmosomal proteins and mediate signalling. Integrin α6β4 is a major component of hemidesmosomes that mediate the stable anchorage of epithelial cells to the underlying basement membrane. Integrin α6β4 has also been implicated in cell proliferation and migration and in carcinoma progression. The third and fourth fibronectin type III domains (FnIII-3, 4) of integrin β4 mediate binding to the hemidesmosomal proteins BPAG1e and BPAG2, and participate in signalling. Here, it is demonstrated that X-ray crystallography, small-angle X-ray scattering and double electron–electron resonance (DEER) complement each other to solve the structure of the FnIII-3, 4 region. The crystal structures of the individual FnIII-3 and FnIII-4 domains were solved and the relative arrangement of the FnIII domains was elucidated by combining DEER with site-directed spin labelling. Multiple structures of the interdomain linker were modelled by Monte Carlo methods complying with DEER constraints, and the final structures were selected against experimental scattering data. FnIII-3, 4 has a compact and cambered flat structure with an evolutionary conserved surface that is likely to correspond to a protein-interaction site. Finally, this hybrid method is of general application for the study of other macromolecules and complexes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulated x-ray scattering of protein solutions using explicit-solvent models

X-ray solution scattering shows new promise for the study of protein structures, complementing crystallography and nuclear magnetic resonance. In order to realize the full potential of solution scattering, it is necessary to not only improve experimental techniques but also develop accurate and efficient computational schemes to relate atomistic models to measurements. Previous computational methods, based on continuum models of water, have been unable to calculate scattering patterns accurately, especially in the wide-angle regime which contains most of the information on the secondary, tertiary, and quaternary structures. Here we present a novel formulation based on the atomistic description of water, in which scattering patterns are calculated from atomic coordinates of protein and water. Without any empirical adjustments, this method produces scattering patterns of unprecedented accuracy in the length scale between 5 and 100 A, as we demonstrate by comparing simulated and observed scattering patterns for myoglobin and lysozyme.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Epitaxial Fe-Ge thin films on Ge(111): Morphology, structure, and magnetic properties versus stoichiometry

We have studied the growth and magnetic properties of thin Fe-Ge films synthesized (codeposited at room temperature and postannealed at 250 deg. C) on Ge(111) wafers versus stoichiometry. Morphology and crystal structure have been investigated in situ by means of scanning tunneling microscopy, low-energy electron diffraction, and x-ray photoelectron diffraction and ex situ with x-ray diffraction. The magnetic properties were characterized ex situ by conventional polar and longitudinal magneto-optical Kerr effect and transverse biased initial inverse susceptibility and torque measurements. It is found that the growth is epitaxial for Ge content up to approx48 at. % (approxFe{sub 1.1}Ge composition). In particular, the film is homogeneous and flat and adopts a crystalline structure of hexagonal symmetry derived from the B8{sub 2} (Ni{sub 2}In) structure over a wide stoichiometry range extending from Fe{sub 2}Ge to Fe{sub 1.1}Ge. The epitaxial orientation between the Ge substrate and the germanide layer is (0001)Fe-Ge||(111)Ge with [1120]Fe-Ge||110]Ge. We found however that the surface periodicity and the out-of-plane lattice parameter c evolve within this stoichiometry range and two distinct stoichiometry regimes appear on both sides of a critical stoichiometry (approxFe{sub 1.5}Ge). Indeed, from Fe{sub 2}Ge to Fe{sub 1.5}Ge the surface periodicity is p(2x2) and c continuously decreases with Fe content, whereas from Fe{sub 1.5}Ge to Fe{sub 1.1}Ge the surface periodicity is (sq root(3)xsq root(3))R30 deg. and c remains constant. These features have been interpreted as a clear fingerprint of a minor transformation of the crystalline structure but without any change in symmetry. This structural order transformation is discussed in relation to previous results reported in the case of macroscopic single-crystal Fe-Ge ingots. On both sides of the wide [Fe{sub 2}Ge,Fe{sub 1.1}Ge] composition range the layer is no more homogeneous. More precisely, for higher Fe content the film contains both the above mentioned Ni{sub 2}In-derived phase and a Fe-richer phase (probably bcc Fe) whereas for higher Ge content the layer is amorphous. Magnetic characterization showed in particular that the homogeneous Ni{sub 2}In-derived epilayers are ferromagnetic with a Curie temperature that varies drastically with the stoichiometry, rising up to a high T{sub C} value of approx450 K for the Fe-rich Fe{sub 1.9}Ge composition. Finally, whatever the stoichiometry, the magnetic easy axis of the homogeneous phase lies in the film plane and a small uniaxial anisotropy is superimposed on a sixfold order one that results from the hexagonal symmetry of the crystallographic structure.

36 MATERIALS SCIENCE↗

BioCARS: Synchrotron facility for probing structural dynamics of biological macromolecules

A major goal in biomedical science is to move beyond static images of proteins and other biological macromolecules to the internal dynamics underlying their function. This level of study is necessary to understand how these molecules work and to engineer new functions and modulators of function. Stemming from a visionary commitment to this problem by Keith Moffat decades ago, a community of structural biologists has now enabled a set of x-ray scattering technologies for observing intramolecular dynamics in biological macromolecules at atomic resolution and over the broad range of timescales over which motions are functionally relevant. Many of these techniques are provided by BioCARS, a cutting-edge synchrotron radiation facility built under Moffat leadership and located at the Advanced Photon Source at Argonne National Laboratory. BioCARS enables experimental studies of molecular dynamics with time resolutions spanning from 100 ps to seconds and provides both time-resolved x-ray crystallography and small- and wide-angle x-ray scattering. Structural changes can be initiated by several methods—UV/Vis pumping with tunable picosecond and nanosecond laser pulses, substrate diffusion, and global perturbations, such as electric field and temperature jumps. Studies of dynamics typically involve subtle perturbations to molecular structures, requiring specialized computational techniques for data processing and interpretation. In this review, we present the challenges in experimental macromolecular dynamics and describe the current state of experimental capabilities at this facility. As Moffat imagined years ago, BioCARS is now positioned to catalyze the scientific community to make fundamental advances in understanding proteins and other complex biological macromolecules.

59 BASIC BIOLOGICAL SCIENCES↗

From lows to highs: using low-resolution models to phase X-ray data

An unusual example of how virus structure determination pushes the limits of the molecular replacement method is presented. The study of virus structures has contributed to methodological advances in structural biology that are generally applicable (molecular replacement and noncrystallographic symmetry are just two of the best known examples). Moreover, structural virology has been instrumental in forging the more general concept of exploiting phase information derived from multiple structural techniques. This hybridization of structural methods, primarily electron microscopy (EM) and X-ray crystallography, but also small-angle X-ray scattering (SAXS) and nuclear magnetic resonance (NMR) spectroscopy, is central to integrative structural biology. Here, the interplay of X-ray crystallography and EM is illustrated through the example of the structural determination of the marine lipid-containing bacteriophage PM2. Molecular replacement starting from an ∼13 Å cryo-EM reconstruction, followed by cycling density averaging, phase extension and solvent flattening, gave the X-ray structure of the intact virus at 7 Å resolution This in turn served as a bridge to phase, to 2.5 Å resolution, data from twinned crystals of the major coat protein (P2), ultimately yielding a quasi-atomic model of the particle, which provided significant insights into virus evolution and viral membrane biogenesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Epitaxial growth of fcc-Co{sub x}Ni{sub 100-x} thin films on MgO(110) single-crystal substrates

Co{sub x}Ni{sub 100-x} (x=100, 80, 20, 0 at. %) epitaxial thin films were prepared on MgO(110) single-crystal substrates heated at 300 deg. C by ultrahigh vacuum molecular beam epitaxy. The growth mechanism is discussed based on lattice strain and crystallographic defects. CoNi(110) single-crystal films with a fcc structure are obtained for all compositions. Co{sub x}Ni{sub 100-x} film growth follows the Volmer-Weber mode. X-ray diffraction analysis indicates that the out-of-plane and the in-plane lattice spacings of the Co{sub x}Ni{sub 100-x} films are in agreement within +-0.5% with the values of the respective bulk Co{sub x}Ni{sub 100-x} crystals, suggesting that the strain in the film is very small. High-resolution cross-sectional transmission microscopy shows that an atomically sharp boundary is formed between a Co(110){sub fcc} film and a MgO(110) substrate, where periodical misfit dislocations are preferentially introduced in the film at the Co/MgO interface. The presence of such periodical misfit dislocations relieves the strain caused by the lattice mismatch between the film and the substrate.

36 MATERIALS SCIENCE↗

Towards phasing using high X-ray intensity

X-ray free-electron lasers (XFELs) show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential `bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. In conclusion, a pattern sorting scheme is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

The molecular architecture of the yeast spindle pole body core determined by Bayesian integrative modeling

Microtubule-organizing centers (MTOCs) form, anchor, and stabilize the polarized network of microtubules in a cell. The central MTOC is the centrosome that duplicates during the cell cycle and assembles a bipolar spindle during mitosis to capture and segregate sister chromatids. Yet, despite their importance in cell biology, the physical structure of MTOCs is poorly understood. Here we determine the molecular architecture of the core of the yeast spindle pole body (SPB) by Bayesian integrative structure modeling based on in vivo fluorescence resonance energy transfer (FRET), small-angle x-ray scattering (SAXS), x-ray crystallography, electron microscopy, and two-hybrid analysis. The model is validated by several methods that include a genetic analysis of the conserved PACT domain that recruits Spc110, a protein related to pericentrin, to the SPB. The model suggests that calmodulin can act as a protein cross-linker and Spc29 is an extended, flexible protein. The model led to the identification of a single, essential heptad in the coiled-coil of Spc110 and a minimal PACT domain. It also led to a proposed pathway for the integration of Spc110 into the SPB.

59 BASIC BIOLOGICAL SCIENCES↗

Unambiguous determination of H-atom positions: comparing results from neutron and high-resolution X-ray crystallography

The locations of H atoms in biological structures can be difficult to determine using X-ray diffraction methods. Neutron diffraction offers a relatively greater scattering magnitude from H and D atoms. Here, 1.65 {angstrom} resolution neutron diffraction studies of fully perdeuterated and selectively CH{sub 3}-protonated perdeuterated crystals of Pyrococcus furiosus rubredoxin (D-rubredoxin and HD-rubredoxin, respectively) at room temperature (RT) are described, as well as 1.1 {angstrom} resolution X-ray diffraction studies of the same protein at both RT and 100 K. The two techniques are quantitatively compared in terms of their power to directly provide atomic positions for D atoms and analyze the role played by atomic thermal motion by computing the {sigma} level at the D-atom coordinate in simulated-annealing composite D-OMIT maps. It is shown that 1.65 {angstrom} resolution RT neutron data for perdeuterated rubredoxin are {approx}8 times more likely overall to provide high-confidence positions for D atoms than 1.1 {angstrom} resolution X-ray data at 100 K or RT. At or above the 1.0{sigma} level, the joint X-ray/neutron (XN) structures define 342/378 (90%) and 291/365 (80%) of the D-atom positions for D-rubredoxin and HD-rubredoxin, respectively. The X-ray-only 1.1 {angstrom} resolution 100 K structures determine only 19/388 (5%) and 8/388 (2%) of the D-atom positions above the 1.0{sigma} level for D-rubredoxin and HD-rubredoxin, respectively. Furthermore, the improved model obtained from joint XN refinement yielded improved electron-density maps, permitting the location of more D atoms than electron-density maps from models refined against X-ray data only.

59 BASIC BIOLOGICAL SCIENCES↗

Correlation function metrology for warm dense matter: Recent developments and practical guidelines

X-ray Thomson scattering (XRTS) has emerged as a valuable diagnostic for matter under extreme conditions, as it captures the intricate many-body physics of the probed sample. Recent advances, such as the model-free temperature diagnostic of Dornheim et al. [Nat. Commun. 13 , 7911 (2022)], have demonstrated how much information can be extracted directly within the imaginary-time formalism. However, since the imaginary-time formalism is a concept often difficult to grasp, we provide here a systematic overview of its theoretical foundations and explicitly demonstrate its practical applications to temperature inference, including relevant subtleties. Furthermore, we present recent developments that enable the determination of the absolute normalization, Rayleigh weight, and density from XRTS measurements without reliance on uncontrolled model assumptions. Finally, we outline a unified workflow that guides the extraction of these key observables, offering a practical framework for applying the method to interpret experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wavelength-resolved Neutron Tomography for Crystalline Materials

Wavelength-resolved (WR) neutron transmission tomography is an emerging technique to characterize engineering materials. While tomographic reconstruction for amorphous samples is straightforward, it is challenging to reconstruct samples with single-crystal domains because the attenuation of the sample varies as a function of its orientation with respect to the incident beam due to Bragg scattering. In this paper, we present an algorithm that can reconstruct samples with single-crystal domains from WR neutron tomographic measurements. In particular, we use a model-based iterative reconstruction (MBIR) technique that reconstructs the volume by identifying and leaving out the regions of the measurement that are affected by Bragg scatter. We combine the output of the MBIR method with an algorithm that matches the reconstruction to the identified Bragg scatter to reconstruct a feature that corresponds to the local crystallography of the sample being measured. Using simulated data, we demonstrate how our algorithm can reconstruct materials with single-crystal domains, thereby adding a powerful new capability for WR neutron imaging instruments.

Singanallur Vaidyanathan, Venkatakrishnan↗

Toward a quantitative description of solvation structure: a framework for differential solution scattering measurements

Appreciating that the role of the solute–solvent and other outer-sphere interactions is essential for understanding chemistry and chemical dynamics in solution, experimental approaches are needed to address the structural consequences of these interactions, complementing condensed-matter simulations and coarse-grained theories. High-energy X-ray scattering (HEXS) combined with pair distribution function analysis presents the opportunity to probe these structures directly and to develop quantitative, atomistic models of molecular systems in situ in the solution phase. However, at concentrations relevant to solution-phase chemistry, the total scattering signal is dominated by the bulk solvent, prompting researchers to adopt a differential approach to eliminate this unwanted background. Though similar approaches are well established in quantitative structural studies of macromolecules in solution by small- and wide-angle X-ray scattering (SAXS/WAXS), analogous studies in the HEXS regime—where sub-ångström spatial resolution is achieved—remain underdeveloped, in part due to the lack of a rigorous theoretical description of the experiment. To address this, herein we develop a framework for differential solution scattering experiments conducted at high energies, which includes concepts of the solvent-excluded volume introduced to describe SAXS/WAXS data, as well as concepts from the time-resolved X-ray scattering community. Our theory is supported by numerical simulations and experiment and paves the way for establishing quantitative methods to determine the atomic structures of small molecules in solution with resolution approaching that of crystallography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation and performance of SIBYLS: a dual endstation small-angle X-ray scattering and macromolecular crystallography beamline at the Advanced Light Source

The SIBYLS beamline (12.3.1) of the Advanced Light Source at Lawrence Berkeley National Laboratory, supported by the US Department of Energy and the National Institutes of Health, is optimized for both small-angle X-ray scattering (SAXS) and macromolecular crystallography (MX), making it unique among the world's mostly SAXS or MX dedicated beamlines. Since SIBYLS was commissioned, assessments of the limitations and advantages of a combined SAXS and MX beamline have suggested new strategies for integration and optimal data collection methods and have led to additional hardware and software enhancements. Features described include a dual mode monochromator [containing both Si(111) crystals and Mo/B 4 C multilayer elements], rapid beamline optics conversion between SAXS and MX modes, active beam stabilization, sample-loading robotics, and mail-in and remote data collection. These features allow users to gain valuable insights from both dynamic solution scattering and high-resolution atomic diffraction experiments performed at a single synchrotron beamline. Key practical issues considered for data collection and analysis include radiation damage, structural ensembles, alternative conformers and flexibility. SIBYLS develops and applies efficient combined MX and SAXS methods that deliver high-impact results by providing robust cost-effective routes to connect structures to biology and by performing experiments that aid beamline designs for next generation light sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Introduction to phasing

This introductory paper to the CCP4 weekend on experimental phasing introduces the concept of the ‘phase problem’ for non-experts. Modern methods of phasing are explored, including some recent examples that can be downloaded as tutorials. When collecting X-ray diffraction data from a crystal, we measure the intensities of the diffracted waves scattered from a series of planes that we can imagine slicing through the crystal in all directions. From these intensities we derive the amplitudes of the scattered waves, but in the experiment we lose the phase information; that is, how we offset these waves when we add them together to reconstruct an image of our molecule. This is generally known as the ‘phase problem’. We can only derive the phases from some knowledge of the molecular structure. In small-molecule crystallography, some basic assumptions about atomicity give rise to relationships between the amplitudes from which phase information can be extracted. In protein crystallography, these ab initio methods can only be used in the rare cases in which there are data to at least 1.2 Å resolution. For the majority of cases in protein crystallography phases are derived either by using the atomic coordinates of a structurally similar protein (molecular replacement) or by finding the positions of heavy atoms that are intrinsic to the protein or that have been added (methods such as MIR, MIRAS, SIR, SIRAS, MAD, SAD or combinations of these). The pioneering work of Perutz, Kendrew, Blow, Crick and others developed the methods of isomorphous replacement: adding electron-dense atoms to the protein without disturbing the protein structure. Nowadays, methods from small-molecule crystallography can be used to find the heavy-atom substructure and the phases for the whole protein can be bootstrapped from this prior knowledge. More recently, improved X-ray sources, detectors and software have led to the routine use of anomalous scattering to obtain phase information from either incorporated selenium or intrinsic sulfurs. In the best cases, only a single set of X-ray data (SAD) is required to provide the positions of the anomalous scatters, which together with density-modification procedures can reveal the structure of the complete protein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate determination of segmented X-ray detector geometry

Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. Furthermore, we show that the refined detector geometry greatly improves the results of experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗