Nickel-hydrogen LEO cycling at 20 percent - 50 percent DOD
The test setup consists of four major elements: the programmable power supplies and load banks, the data acquisition and control system control computer, and the NiH2 specimen test cells. A simplified block diagram of the test setup is shown. The test setup provides complete battery isolation should a fault occur, and fusing as necessary to protect the battery cells and other equipment. Front panel switches provide for power supply configuration and battery isolation. Front panel meters provide continuous real-time visual monitoring of the voltage and current for each pack of cells. A strip chart recorder provides a hard copy of the voltage and current profiles for each of the packs. The test operates continuously with minimal human interface, except during special tests. The two power supplies are controlled by resistance programming. A bank of resistors and relays was built which can be switched by the control computer to provide control over the charge current to the batteries. The load banks are controlled by the 3497A. The 3497A is equipped with a 0.5 volt programmable power supply which is used to voltage program the load banks. A Hewlett-Packard Vectra 9000 running an HP Basic program is used as the control computer to remotely instruct the 3497A (data acquisition and control) to scan the data channels and retrieve test data. The program then reads, calculates, and stores the data. If an anomaly occurs, the program will disconnect the cells and shut down the test to avoid damage to the cells or equipment.