Modular Integrated Stackable Layers (MISL) 1.1 Design Specification

This document establishes the design guideline of the Modular Instrumentation Data Acquisition (MI‐DAQ) system in utilization of several designs available in EV. The MI‐ DAQ provides the options to the customers depending on their system requirements i.e. a 28V interface power supply, a low power battery operated system, a low power microcontroller, a higher performance microcontroller, a USB interface, a Ethernet interface, a wireless communication, various sensor interfaces, etc. Depending on customer's requirements, the each functional board can be stacked up from a bottom level of power supply to a higher level of stack to provide user interfaces. The stack up of boards are accomplished by a predefined and standardized power bus and data bus connections which are included in this document along with other physical and electrical guidelines. This guideline also provides information for a new design options. This specification is the product of a collaboration between NASA/JSC/EV and Texas A&M University. The goal of the collaboration is to open source the specification and allow outside entities to design, build, and market modules that are compatible with the specification. NASA has designed and is using numerous modules that are compatible to this specification. A limited number of these modules will also be released as open source designs to support the collaboration. The released designs are listed in the Applicable Documents.

Yim, Hester J.↗

Slow control and data acquisition development in the Mu2e experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far.Mu2e’s Trigger and Data Acquisition System (TDAQ) uses {\it otsdaq} solution. Developed at Fermilab, {\it otsdaq} uses the {\it artdaq} DAQ framework and {\it art} analysis framework, for event transfer, filtering, and processing.{\it otsdaq} is an online DAQ software suite with a focus on flexibility and scalability, and provides a multi-user interface accessible through a web browser.A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) open source Platform. The DCS System has also been integrated into {\it otsdaq}, providing a GUI multi-user, web-based control, and monitoring dashboard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Data Acquisition Graphical User Interface

Traditional radioxenon measurements have been done by ground based fixed systems, however in recent years there has been an increased need for systems capable of quick deployment or even complete mobility. Using the Pixie-4 data acquisition (DAQ) system can help reduce the electronics footprint of both current systems, like the radioxenon Radionuclide Laboratory 16 (RL-16) and the Swedish Automatic Unit for Noble Gas Acquisition (SAUNA), as well as future systems. Pacific Northwest National Laboratory (PNNL) has developed a Linux based Nyx graphical user interface (GUI) for Pixie-4 cards. The Nyx software can be installed on various Linux platforms and is written in C++. This software offers a rich user interface for configuring and operating the Pixie4 card and PNNL designed high voltage (HV) cards. Nyx allows one to quickly get a nuclear detector operational by maintaining the core diagnostic features built into the Pixie-4 cards. First, Nyx maintains the multitude of adjustable parameters accessible in the Pixie-4 cards, which allows one to customize settings to take full advantage of a particular detector. Nyx also maintains an oscilloscope feature which is extremely useful to optimize settings and to verify proper detector behavior and is often the first feature used in Nyx during detector setup. Finally, Nyx allows the user to collect data in several formats including full pulse shapes to basic histograms. Overall, it is the corner stone for the transition of beta-gamma systems to a state-of-the-art digitizing DAQ.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Mu2e DAQ and slow control systems

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the feld of an aluminum nucleus with a sensitivity improvement by a factor of 10,000 over existing limits. The Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, fltering, and processing. otsdaq is an online DAQ software suite with a focus on fexibility and scalability and provides a multiuser, web-based, interface accessible through a web browser. The data stream from the detector subsystems is read by a software flter algorithm that selects events which are combined with the data fux coming from a Cosmic Ray Veto System. The Detector Control System (DCS) has been developed using the Experimental Physics and Industrial Control System (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS System has been integrated into otsdaq. A prototype of the TDAQ and the DCS systems has been built at Fermilab’s Feynman Computing Center. In this paper, we report on the progress of the integration of this prototype in the online otsdaq software.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slow control and data acquisition systems in the Mu2e experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinolessconversion of a muon into an electron in the field of an aluminum nucleus with a sensitivityimprovement by a factor of 10,000 over existing limits. The Mu2e Trigger and Data AcquisitionSystem (TDAQ) usesotsdaqas the online Data Acquisition System (DAQ) solution. Developed atFermilab,otsdaqintegrates both theartdaqDAQ and theartanalysis frameworks for event transfer,filtering, and processing.otsdaqis an online DAQ software suite with a focus on flexibility andscalability and provides a multi-user, web-based, interface accessible through a web browser. Thedata stream from the detector subsystems is read by a software filter algorithm that selects eventswhich are combined with the data flux coming from a Cosmic Ray Veto System. The DetectorControl System (DCS) has been developed using the Experimental Physics and Industrial ControlSystem (EPICS) open source platform for monitoring, controlling, alarming, and archiving. TheDCS System has been integrated intootsdaq. A prototype of the TDAQ and the DCS systems hasbeen built at Fermilab’s Feynman Computing Center. In this paper, we report on the progress ofthe integration of this prototype in the onlineotsdaqsoftware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Data Acquisition and Slow Control Systems for the Mu2e Experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10 000 over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable with direct searches at either present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system exploits otsdaq as its online Data Acquisition System (DAQ) solution. Furthermore, developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability and provides a multi-user, web-based, interface accessible through a web browser. The read out controllers (ROCs) stream out zero-suppressed data continuously from the detector subsystems to the data transfer controllers (DTCs). The data stream is then read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events which are combined with the data flux coming from a cosmic-ray veto (CRV) system. The detector control system (DCS) has been developed using the experimental physics and industrial control system (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS has been integrated into otsdaq. A prototype of the TDAQ system and the DCS has been built at Fermilab's Feynman Computing Center. In this article, we report on the progress of the integration of this prototype in the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trigger-DAQ and Slow Controls Systems in the Mu2e Experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far. Mu2e's Trigger and Data Acquisition System (TDAQ) uses otsdaq as its solution. Developed at Fermilab, otsdaq uses the artdaq DAQ framework and art analysis framework, under the-hood, for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability, while providing a multi-user, web-based, interface accessible through the Chrome or Firefox web browser. The detector Read Out Controller (ROC), from the tracker and calorimeter, stream out zero-suppressed data continuously to the Data Transfer Controller (DTC). Data is then read over the PCIe bus to a software filter algorithm that selects events which are finally combined with the data flux that comes froma Cosmic Ray Ve to System (CRV). A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) Open Source Platform. The DCS System has also been itegrated into otsdaq. The installation of the TDAQ and the DCS systems in the Mu2e building is planned for 2021-2022, and a prototype has been built at Fermilab's Feynman Computing Center. We report here on the developments and achievements of the integration of Mu2e's DCS system into the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined Cycle Engine Large-Scale Inlet for Mode Transition Experiments: System Identification Rack Hardware Design

The System Identification (SysID) Rack is a real-time hardware-in-the-loop data acquisition (DAQ) and control instrument rack that was designed and built to support inlet testing in the NASA Glenn Research Center 10- by 10-Foot Supersonic Wind Tunnel. This instrument rack is used to support experiments on the Combined-Cycle Engine Large-Scale Inlet for Mode Transition Experiment (CCE‒ LIMX). The CCE‒LIMX is a testbed for an integrated dual flow-path inlet configuration with the two flow paths in an over-and-under arrangement such that the high-speed flow path is located below the lowspeed flow path. The CCE‒LIMX includes multiple actuators that are designed to redirect airflow from one flow path to the other; this action is referred to as "inlet mode transition." Multiple phases of experiments have been planned to support research that investigates inlet mode transition: inlet characterization (Phase-1) and system identification (Phase-2). The SysID Rack hardware design met the following requirements to support Phase-1 and Phase-2 experiments: safely and effectively move multiple actuators individually or synchronously; sample and save effector control and position sensor feedback signals; automate control of actuator positioning based on a mode transition schedule; sample and save pressure sensor signals; and perform DAQ and control processes operating at 2.5 KHz. This document describes the hardware components used to build the SysID Rack including their function, specifications, and system interface. Furthermore, provided in this document are a SysID Rack effectors signal list (signal flow); system identification experiment setup; illustrations indicating a typical SysID Rack experiment; and a SysID Rack performance overview for Phase-1 and Phase-2 experiments. The SysID Rack described in this document was a useful tool to meet the project objectives.

Thomas, Randy↗

Advanced Resistive Exercise Device (ARED) Flight Software (FSW): A Unique Approach to Exercise in Long Duration Habitats

ARED flight instrumentation software is associated with an overall custom designed resistive exercise system that will be deployed on the International Space Station (ISS). This innovative software application fuses together many diverse and new technologies into a robust and usable package. The software takes advantage of touchscreen user interface technology by providing a graphical user interface on a Windows based tablet PC, meeting a design constraint of keyboard-less interaction with flight crewmembers. The software interacts with modified commercial data acquisition (DAQ) hardware to acquire multiple channels of sensor measurment from the ARED device. This information is recorded on the tablet PC and made available, via International Space Station (ISS) Wireless LAN (WLAN) and telemetry subsystems, to ground based mission medics and trainers for analysis. The software includes a feature to accept electronically encoded prescriptions of exercises that guide crewmembers through a customized regimen of resistive weight training, based on personal analysis. These electronically encoded prescriptions are provided to the crew via ISS WLAN and telemetry subsystems. All personal data is securely associated with an individual crew member, based on a PIN ID mechanism.

Mangieri, Mark↗

The laser control of the muon g -2 experiment at Fermilab

Here, we present that the Muon g-2 Experiment at Fermilab is expected to start data taking in 2017. It will measure the muon anomalous magnetic moment, a μ = (g μ -2)/2 to an unprecedented precision: the goal is 0.14 parts per million (ppm). The new experiment will require upgrades of detectors, electronics and data acquisition equipment to handle the much higher data volumes and slightly higher instantaneous rates. In particular, it will require a continuous monitoring and state-of-art calibration of the detectors, whose response may vary on both the millisecond and hour long timescale. The calibration system is composed of six laser sources and a light distribution system will provide short light pulses directly into each crystal (54) of the 24 calorimeters which measure energy and arrival time of the decay positrons. A Laser Control board will manage the interface between the experiment and the laser source, allowing the generation of light pulses according to specific needs including detector calibration, study of detector performance in running conditions, evaluation of DAQ performance. Here we present and discuss the main features of the Laser Control board.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Redis-Based Streaming Architecture for Accelerator Beam Instrumentation DAQ Systems

The Fermilab Acceleraor Division, Beam Instrumentation Department, is always adopting modern and current software methodologies for complex DAQ architectures. This paper highlights the Redis Adapter (RA) as the key software component enabling high performance, modular communication between digitizers and distributed control systems by leveraging Redis and containerization. The RA provides a unified, efficient interface between Redis based data streams and consumer systems. In the legacy architecture, digitized data flowed through the custom, UDP based Distributed Data Communication Protocol in the middle layer. In the current system, DDCP remains the ingestion path, while the RA serves as the decoupling layer. The proposed system replaces old VME digitizers with a SOM-based digitizer that communicates with Redis using the RA. The RA acts as both a performance-critical bridge and a protocol-agnostic adapter, ensuring compatibility with legacy control frameworks while enabling future scalability and modularity. This restructuring of the middle layer also helps the system achieve high throughput, reduce latency, and simplify the data path. Finally, we will demonstrate how RA is utilized in our two core products to deliver both legacy compatibility and future flexibility.

Joshi, S. [Fermilab]↗

Development of flexible, scalable, low cost readout for beam tests of the high granularity calorimeter for the CMS endcap

As part of the development of the High Granularity Calorimeter for the CMS Endcap at HL-LHC, The CMS collaboration is conducting a comprehensive series of beam tests. The first beam test, with a single HGC module was carried out in March of 2016 at the Fermilab Test Beam Facility, continuing to a 16 module test in July of 2016. We describe here the development of a low cost readout system that is simple to implement and is able to grow with the system under test. The system is based on the low cost Zynq SoC that allows simple DAQ development in a Linux environment. For this application we used the Digilent ZedBoard, which allows high speed LVDS links and Linux software development on a single commercial board. A small custom FPGA board designed to comply with the VITA 57 Field Programmable Mezzanine Card standard implements the interface to the readout ASIC mounted on the HGC sensor modules and provides the LVDS links to the ZedBoard, either directly over the FMC connector or via a custom carrier card. This architecture provides scalability, ease of development and low cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing $otsdaq$ for Optimized Data Acquisition

High-energy physics (HEP) experiments demand data acquisition (DAQ) systems capable of orchestrating complex detector operations, high data throughput, and responsive, real-time feedback. Traditional systems often have steep learning curves, making onboarding difficult for new users. The Off-The-Shelf Data Acquisition $otsdaq$ framework was developed to address these issues by providing a modular and flexible interface that is easier to operate while remaining customizable enough for experimental setups. As the upcoming Mu2e experiment prepares for deployment, improving stability, usability, and performance has become increasingly critical. Our work enhances $otsdaq$ with features that streamline visualization, correct data metrics, improve debugging workflows, and stabilize the user interface.

Mohammed, Ali (ORCID:0009000860386626)↗

Multiple aspects maintenance ontology-based intelligent maintenance optimization framework for safety-critical systems

Abstract Maintenance optimization is a process for improving the efficiency of maintenance strategies and activities, considering various aspects of the target system and components, such as the probabilities of system failures and the cost of repair and replacement of a failed component. The improvement of maintenance optimization algorithms generally requires information from various data sources. For example, it may require the system risk information derived from risk analysis tools or the residual lifetime of a component from fault prognosis tools. The requirements of data acquisition (DAQ) and aggregation pose new challenges for maintenance management systems (MMSs) that implement and use these maintenance optimization algorithms. This paper proposes a multiple aspects maintenance ontology-based framework to facilitate DAQ from MMSs, online monitoring systems, fault detection and discrimination tools, risk assessment tools, decision-making tools, and component identification tools, and accelerate the implementation and verification of contemporary maintenance optimization models and algorithms. The proposed framework consists of a multi-aspect maintenance ontology with critical information for maintenance optimization and application interfaces for collecting information from various data sources, such as fault prognosis tools, online monitoring tools, risk assessment tools, and decision-making algorithms. In addition, this paper proposes a heuristic method for integrating concepts and properties from other existing ontologies into the proposed framework when the existing ontology is not fully compatible with the ontology under construction. Finally, the paper verifies the proposed ontology framework using a feedwater system designed for nuclear power plants with valves and filters as the components under maintenance.

Diao, Xiaoxu (ORCID:0000000346726352)↗

Digital Architecture for a Trace Gas Sensor Platform

A digital architecture has been implemented for a trace gas sensor platform, as a companion to standard analog control electronics, which accommodates optical absorption whose fractional absorbance equivalent would result in excess error if assumed to be linear. In cases where the absorption (1-transmission) is not equivalent to the fractional absorbance within a few percent error, it is necessary to accommodate the actual measured absorption while reporting the measured concentration of a target analyte with reasonable accuracy. This requires incorporation of programmable intelligence into the sensor platform so that flexible interpretation of the acquired data may be accomplished. Several different digital component architectures were tested and implemented. Commercial off-the-shelf digital electronics including data acquisition cards (DAQs), complex programmable logic devices (CPLDs), field-programmable gate arrays (FPGAs), and microcontrollers have been used to achieve the desired outcome. The most completely integrated architecture achieved during the project used the CPLD along with a microcontroller. The CPLD provides the initial digital demodulation of the raw sensor signal, and then communicates over a parallel communications interface with a microcontroller. The microcontroller analyzes the digital signal from the CPLD, and applies a non-linear correction obtained through extensive data analysis at the various relevant EVA operating pressures. The microcontroller then presents the quantitatively accurate carbon dioxide partial pressure regardless of optical density. This technique could extend the linear dynamic range of typical absorption spectrometers, particularly those whose low end noise equivalent absorbance is below one-part-in-100,000. In the EVA application, it allows introduction of a path-length-enhancing architecture whose optical interference effects are well understood and quantified without sacrificing the dynamic range that allows quantitative detection at the higher carbon dioxide partial pressures. The digital components are compact and allow reasonably complete integration with separately developed analog control electronics without sacrificing size, mass, or power draw.

Gonzales, Paula↗

DAQExpert the service to increase CMS data-taking efficiency

The Data Acquisition (DAQ) system of the Compact Muon Solenoid (CMS) experiment at the LHC is a complex system responsible for the data readout, event building and recording of accepted events. Its proper functioning plays a critical role in the data-taking efficiency of the CMS experiment. In order to ensure high availability and recover promptly in the event of hardware or software failure of the subsystems, an expert system, the DAQ Expert, has been developed. It aims at improving the data taking efficiency, reducing the human error in the operations and minimising the on-call expert demand. Introduced in the beginning of 2017, it assists the shift crew and the system experts in recovering from operational faults, streamlining the post mortem analysis and, at the end of Run 2, triggering fully automatic recovery without human intervention. DAQ Expert analyses the real-time monitoring data originating from the DAQ components and the high-level trigger updated every few seconds. It pinpoints data flow problems, and recovers them automatically or after given operator approval. We analyse the CMS downtime in the 2018 run focusing on what was improved with the introduction of automated recovery; present challenges and design of encoding the expert knowledge into automated recovery jobs. Furthermore, we demonstrate the web-based, ReactJS interfaces that ensure an effective cooperation between the human operators in the control room and the automated recovery system. We report on the operational experience with automated recovery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New operator assistance features in the CMS Run Control System

During Run-1 of the LHC, many operational procedures have been automated in the run control system of the Compact Muon Solenoid (CMS) experiment. When detector high voltages are ramped up or down or upon certain beam mode changes of the LHC, the DAQ system is automatically partially reconfigured with new parameters. Certain types of errors such as errors caused by single-event upsets may trigger an automatic recovery procedure. Furthermore, the top-level control node continuously performs cross-checks to detect sub-system actions becoming necessary because of changes in configuration keys, changes in the set of included front-end drivers or because of potential clock instabilities. The operator is guided to perform the necessary actions through graphical indicators displayed next to the relevant command buttons in the user interface. Through these indicators, consistent configuration of CMS is ensured. However, manually following the indicators can still be inefficient at times. A new assistant to the operator has therefore been developed that can automatically perform all the necessary actions in a streamlined order. If additional problems arise, the new assistant tries to automatically recover from these. With the new assistant, a run can be started from any state of the sub-systems with a single click. An ongoing run may be recovered with a single click, once the appropriate recovery action has been selected. We review the automation features of CMS Run Control and discuss the new assistant in detail including first operational experience.