Search NASA⌕ Search

SEARCH · Search NASA

Results for “DARR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mutually magnetically insulated two-species Brillouin flow

In this work, we use the Brillouin flow analytic framework to examine the physics of Magnetically Insulated Transmission Lines (MITL). Here, we derive a model applicable to any particle species, including both positive and negative ions, in planar and cylindrical configurations. We then show how to self-consistently solve for two-species simultaneously, using magnetically insulated electrons and positive ions as an example. We require both layers to be spatially separated and magnetically insulated (mutually magnetically insulated); for a 7.5 cm gap with a 2 MV bias voltage, this condition requires magnetic fields in excess of 2.73 T. We see a close match between mutually insulated MITL performance and “superinsulated” (high degree of magnetic insulation) electron-only theory, as may be expected for these high magnetic fields. However, the presence of ions leads to several novel effects: (1) Opposite to electron-only theory, total electron currents increase rather than decrease as the degree of magnetic insulation becomes stronger. The common assumption of neglecting electrons for superinsulated MITL operation must be revisited when ions are present—we calculate up to 20× current enhancement. (2) The electron flow layer thickness increases up to double, due to ion space-charge enhancement. (3) The contributions from both ions and electrons to the MITL flow impedance are calculated. The flow impedance drops by over 50% when ions fill the gap, which can cause significant reflections at the load if not anticipated and degrade performance. Additional effects and results from the inclusion of the ion layer are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculating the space-charge-limited current density for nonplanar geometries by simulating the charge-free electric field

Calculating the space-charge-limited-current density (SCLCD) for a complicated diode geometry often requires computationally expensive particle-in-cell (PIC) codes. Here, this paper addresses this issue by using the charge-free electric field $E_0$ calculated using COMSOL Multiphysics to determine local and global SCLCD. The SCLCD obtained by using the surface average of $|E_0|^2$ on the cathode recovers theoretical results for one-dimensional (1D) planar, cylindrical, and tip-to-tip geometries in appropriate limits. We next compared tip-to-tip calculations with the SCLCD obtained using the PIC code Empire. The SCLCD calculated using COMSOL agreed well with Empire for flatter 1D tip-to-tip geometries and diverged with increasing sharpness. Physically, Empire predicts lower SCLCD than COMSOL because the electrons spread due to concentrated space-charge at the tip, whereas theory assumes that the electrons follow the charge-free electric field lines. We further assess the behavior of the SCLCD for tips protruding from the centers of flat, circular plates of various areas. Larger plate areas with constant tip size recover the 1D planar SCLCD globally and 1D tip-to-tip SCLCD locally, while reducing the difference between Empire and COMSOL calculations since larger plates capture more of the emitted electrons, reducing SCLCD suppression due to beam spreading. These results show that charge-free electric field simulations can be used to determine the SCLCD without needing to simulate particle dynamics in PIC.

Wright, Jack K. [Purdue Univ., West Lafayette, IN ↗

Targeted inhibition of gut bacterial β-glucuronidase activity enhances anticancer drug efficacy

Irinotecan treats a range of solid tumors, but its effectiveness is severely limited by gastrointestinal (GI) tract toxicity caused by gut bacterial β-glucuronidase (GUS) enzymes. Targeted bacterial GUS inhibitors have been shown to partially alleviate irinotecan-induced GI tract damage and resultant diarrhea in mice. Here, we unravel the mechanistic basis for GI protection by gut microbial GUS inhibitors using in vivo models. We use in vitro, in fimo, and in vivo models to determine whether GUS inhibition alters the anticancer efficacy of irinotecan. We demonstrate that a single dose of irinotecan increases GI bacterial GUS activity in 1 d and reduces intestinal epithelial cell proliferation in 5 d, both blocked by a single dose of a GUS inhibitor. In a tumor xenograft model, GUS inhibition prevents intestinal toxicity and maintains the antitumor efficacy of irinotecan. Remarkably, GUS inhibitor also effectively blocks the striking irinotecan-induced bloom of Enterobacteriaceae in immune-deficient mice. In a genetically engineered mouse model of cancer, GUS inhibition alleviates gut damage, improves survival, and does not alter gut microbial composition; however, by allowing dose intensification, it dramatically improves irinotecan’s effectiveness, reducing tumors to a fraction of that achieved by irinotecan alone, while simultaneously promoting epithelial regeneration. These results indicate that targeted gut microbial enzyme inhibitors can improve cancer chemotherapeutic outcomes by protecting the gut epithelium from microbial dysbiosis and proliferative crypt damage.

60 APPLIED LIFE SCIENCES↗

Theory and simulation of gap distance transitions in planar magnetically insulated transmission lines

Magnetically insulated transmission lines (MITLs) are critical components for efficiently transporting power from pulsed power sources to a diverse range of loads, including magneto-inertial confinement fusion and radiation production. This study investigates the behavior of planar MITLs, taking into account the source voltage and source and load impedances, using two-dimensional theory and simulations. Self-limited behavior, where the MITL operating impedance (voltage divided by current) is insensitive to the value of load impedance, is extended to small-to-large gap distance MITL transitions. Load-limited behavior, in which the load impedance is below the self-limited impedance, causes the MITL operating impedance to adjust to match the load impedance and can be extended to describe large-to-small transitions. In both cases, the operating impedance of the larger MITL section changes to match the self-limited operating impedance of the smaller section. This behavior extends to multiple transitions and to both low and high impedance loads. Assuming equilibration occurs (pulse duration larger than MITL transit time), the entire MITL operating impedance becomes the self-limited impedance of the smallest-gap MITL section or the load impedance, whichever is lower.

Darr, Adam M. [Sandia National Laboratories (SNL-N↗

Theoretical Coupling of Free-Flowing Ions and Magnetically Insulated Electrons

Magnetic insulation of electrons prevents losses and can be applied to generating radiation or electron sources for high current and high power applications. Ion emission from the anode may degrade magnetic insulation. We develop equilibrium theory, self-consistently coupling magnetically insulated electron flow with free-flowing injected ions. Generally, ion injection is self-limiting from space charge; however, once insulation strength drops below about 1.2x the magnetic insulation threshold, ion space-charge limits vanish. Further, the gap effectively short-circuits and the electron flow layer asymptotically approaches the anode. In this regime a quasineutral, nonthermal plasma manifests, effectively reducing gap distance and suggesting quasiequilibrium gap closure evolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Theoretical Assessment of the Transition Between Electron Emission Mechanisms for Nonplanar Diodes

Theoretically and computationally describing the operation of nanodiodes requires characterizing the transitions between multiple electron emission mechanisms for nanodiodes with complicated geometries. This motivates our development of techniques to determine when simplified theories for individual mechanisms suffice compared to more complete, but more computationally expensive, models. Leveraging recent theories that define a canonical gap distance to translate planar theory to nonplanar diodes, we derive the conditions for the transitions among thermal emission, field emission, and space-charge-limited current density (SCLCD) in vacuum and with collisions for non-Cartesian coordinate systems, including spherical, cylindrical, and prolate spheroidal coordinate systems. Particle-in-cell (PIC) simulations of the current density as a function of applied voltage for a tip-to-plate geometry in vacuum agreed qualitatively with the asymptotes for thermal emission at low voltage and SCLCD at higher voltage using the canonical gap distance. As a result, this demonstrates the utility of this approach for guiding system design and suggests future extensions to save simulation time for more realistic geometries that are more computationally expensive.

Conformal mapping↗

WE-EF-BRA-09: Microbeam Radiation Therapy Enhances Tumor Drug Uptake of PEGylated Liposomal Doxorubicin (PLD) in a Triple Negative Breast Cancer GEM Model

Purpose: Overcoming low anti-cancer drug uptake in tumors is a key challenge limiting its clinical use. We propose to enhance the drug delivery using upfront Microbeam Radiation Therapy (MRT). MRT is a preclinical cancer therapy that utilizes microplanar beams to deliver spatially oscillating planes of high and low doses. Animal studies have demonstrated that ultrahigh dose (100s Gy) MRT eradicates tumors without damaging the function of normal tissue exposed to the same radiation. Our previous study indicated that MRT induces intense angiogenesis in tumor rim and surrounding normal tissue 1–2 days post radiation. We hypothesize that the tumor microenvironment modulation induced by MRT may enhance carrier-mediated agent drug delivery to tumors with inherent poor drug uptake. We thus investigated MRT-induced pharmacokinetics (PK) of PEGylated liposomal doxorubicin (PLD), a nano-scale doxorubicin, in T11 genetically engineered mouse model of triple negative breast cancer. Methods: A research irradiator (160kVp, RadSource Technologies) with a customized collimator was used to produce the MRT microbeam of in average 390µm width and 1190µm peak-to-peak distance. The peak dose rate of 1–2Gy/min. Dosimetry is by EBT3 film cross-calibrated with ion chamber at large fields. All mice were administered PLD at 6mg/kg IV x1 at 16h post MRT and sacrificed at 5min, 6h, 24h, and 96h post PLD administration (n=3 or 4 per group). Results: The MRT(28Gy)+PLD group mice had a total doxorubicin tumor concentration (area-under-the concentration-curve, AUC) of 206,040ng/mL•h, 3.71 times the concentration of the PLD-alone group. The MRT(34Gy)+PLD group had a higher mean total doxorubicin concentration in tumor (20,779ng/ml) than the MRT(28Gy)+PLD group (10,665ng/ml). Conclusion: Our preliminary results indicate that microbeam radiation therapy (MRT) can enhance nano-scale anti-cancer drug delivery to tumors approximately 4-fold. The exact working mechanism, the comparison with broad beam irradiation, and optimization of MRT for drug delivery enhancement are under investigation.

60 APPLIED LIFE SCIENCES↗

Water Treatment: Are Membranes the Panacea?

Alongside the rising global water demand, continued stress on current water supplies has sparked interest in using nontraditional source waters for energy, agriculture, industry, and domestic needs. Membrane technologies have emerged as one of the most promising approaches to achieve water security, but implementation of membrane processes for increasingly complex waters remains a challenge. The technical feasibility of membrane processes replacing conventional treatment of alternative water supplies (e.g., wastewater, seawater, and produced water) is considered in the context of typical and emerging water quality goals. This review considers the effectiveness of current technologies (both conventional and membrane based), as well as the potential for recent advancements in membrane research to achieve these water quality goals. We envision the future of water treatment to integrate advanced membranes (e.g., mixed-matrix membranes, block copolymers) into smart treatment trains that achieve several goals, including fit-for-purpose water generation, resource recovery, and energy conservation.

catalysis (heterogeneous)↗

Alternatives Analysis Amchitka Island Mud Pit Cap Repair, Amchitka, Alaska January 2016

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) manages the Nevada Offsites program, which includes a series of reclaimed drilling mud impoundments on Amchitka Island, Alaska (Figure 1). Navarro Research and Engineering, Inc. is the Legacy Management Support contractor (the Contractor) for LM. The Contractor has procured Tetra Tech, Inc. to provide engineering support to the Amchitka mud pit reclamation project. The mud pit caps were damaged during a 7.9-magnitude earthquake that occurred in 2014. The goals of the current project are to investigate conditions at the mud pit impoundments, identify feasible alternatives for repair of the cover systems and the contents, and estimate relative costs of repair alternatives. This report presents descriptions of the sites and past investigations, existing conditions, summaries of various repair/mitigation alternatives, and direct, unburdened, order-of-magnitude (-15% to +50%) associated costs.

54 ENVIRONMENTAL SCIENCES↗

Compact Bremsstrahlung Diode Development on HERMES-III

Testing of a compact Bremsstrahlung diode at the High Energy Radiation Megavolt Electron Source III (HERMES-III) was performed at Sandia National Laboratories in November, 2023. The compact diode described here is the first prototype diode in a campaign to optimize a Bremsstrahlung diode in terms of size and dose production. The goal was to test the diode at 13MV, and the experiment realized between 10-12MV at the diode. Modeling and simulation of this geometry was performed after the test, shedding insight into several phenomena seen by experimental diagnostics. Modifications to the diode and experiment are proposed for future experiments to help explain the phenomena and approach a better final design.

42 ENGINEERING↗

Rapid Demonstration of Bremsstrahlung Diode Optimization

Optimization of the radiation pattern from a Bremsstrahlung target for a given application is possible by controlling the electron beam that impacts the high-atomic-number target. In this work, the electron beam is generated by a 13MV vacuum diode that terminates a coaxial magnetically insulted transmission line (MITL) on the HERMES-III machine at Sandia National Labs. Work by Sanford introduced a geometry for vacuum diodes that can control the flow within bounds. The "indented anode", as coined by Sanford, can straighten out the electron beam in a high-current diode that would otherwise be prone to beam pinching. A straighter beam will produce a more forwardly directed radiation pattern while a pinching electron beam will yield a focal point or hot spot on axis and a more diffuse radiation pattern. Either one of these may be desirable depending on the application. This work serves as a first attempt to optimize the radiation pattern in the former sense of collimating the radiation pattern given a limited parameter space. The optimization is attempted first using electromagnetic particle-in-cell simulations in the EMPIRE code suite. The setup of the models used in EMPIRE is discussed along with some basic theory behind some of the models used in the simulations such as anode heating and secondary ions. Theoretical work performed by Allen Garner and his students at Purdue is included here, which concerns the impact of collisions in these vacuum diodes. The EMPIRE simulations consider both an aggressive and a conservative design. The aggressive design is inherently riskier while the conservative design is chosen as something that, while still a risk, is more likely to perform as expected. The ultimate goal of this work was to validate the EMPIRE code results with experimental data. While the experiment that tested the diode designs proposed by the simulation results fell outside of the fiscal boundaries of this project (and for that reason the results of which are not included in this report), the hardware for the experiment was designed and drafted within those same fiscal boundaries, and is thus included in this report. However, there was yet another experiment performed in this project that tested a key feature of the diode: the hemispherical cathode. Those results are documented here as well, which show that the cathode tip is an important aspect to controlling the diode flow. A short series of simulations on this diode were also performed after the experiment in order to gain a better understanding of the effect of ions. on the flow pattern and faceplate dose profile.

43 PARTICLE ACCELERATORS↗