Search NASA⌕ Search

SEARCH · Search NASA

Results for “DAYLIGHTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Framework for Daylighting Optimization in Whole Buildings with OpenStudio

We present a toolkit and workflow for leveraging the OpenStudio (Guglielmetti et al. 2010) platform to perform daylighting analysis and optimization in a whole building energy modeling (BEM) context. We have re-implemented OpenStudio's integrated Radiance and EnergyPlus functionality as an OpenStudio Measure. The OpenStudio Radiance Measure works within the OpenStudio Application and Parametric Analysis Tool, as well as the OpenStudio Server large scale analysis framework, allowing a rigorous daylighting simulation to be performed on a single building model or potentially an entire population of programmatically generated models. The Radiance simulation results can automatically inform the broader building energy model, and provide dynamic daylight metrics as a basis for decision. Through introduction and example, this paper illustrates the utility of the OpenStudio building energy modeling platform to leverage existing simulation tools for integrated building energy performance simulation, daylighting analysis, and reportage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daylight-Mediated, Passive, and Sustained Release of the Glaucoma Drug Timolol from a Contact Lens

Timolol, a potent inhibitor of β-adrenergic receptors (βARs), is a first-line drug for decreasing the intraocular pressure (IOP) of patients with glaucoma. Timolol is administered using 0.5% eye-drop solutions at >3 × 10 7 times the inhibitory concentration ( k i ) for βARs. This high dose is wasteful and triggers off-target effects that increase medication noncompliance. Here, we introduce contact lenses that release timolol to the eye throughout the day during passive exposures to natural daylight at a more therapeutically relevant concentration (>3000 k i ). Timolol is coupled to the polymer of the contact lens via a photocleavable caged cross-linker and is released exclusively to the surrounding fluid after the 400-430 nm mediated cleavage of the cross-linking group. Studies conducted in a preclinical mouse model of glaucoma show photoreleased timolol is effective as authentic timolol in reducing IOP. Our studies highlight several advantages of daylight-mediated release of timolol from lenses compared to eye-drops. First, fitted contact lenses exposed to natural daylight release sufficient timolol to sustain the inhibition of βARs over a 10 h period. Second, the contact lenses inhibit βARs in the eye using only 5.7% of the timolol within a single eye-drop. Third, the lenses allow the patient to passively control the amount of timolol released from the lens-for example, early morning exposure to outdoor sunlight would release enough timolol to maximally reduce the IOP, whereas subsequent periodic exposures to indoor daylight would release sufficient timolol to overcome the effects of its spontaneous dissociation from βARs. Fourth, our lenses are disposable, designed for single day use, and manufactured at a low cost.

60 APPLIED LIFE SCIENCES↗

Ray tracing study for non-imaging daylight collectors

This paper presents a novel method to study how well non-imaging daylight collectors pipe diffuse daylight into long horizontal funnels for illuminating deep buildings. Forward ray tracing is used to derive luminous intensity distributions curves (LIDC) of such collectors centered in an arc-shaped light source representing daylight. New photometric characteristics such as 2D flux, angular spread and horizontal offset are introduced as a function of such LIDC. They are applied for quantifying and thus comparing different collector contours. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lighting and visual comfort performance of commercially available tubular daylight devices

Tubular daylight devices (TDDs) require a much smaller roof opening than conventional skylights and, because of their highly reflective tube, they can deliver daylight farther away from the building envelope. This can provide lighting energy savings, increasing resilience in new and existing buildings. Different types and configurations are available amongst commercially available TDDs, including domes/diffusers with varying optical properties and the diameter of the TDD. This paper presents a comprehensive experimental evaluation of the lighting and visual comfort performance of multiple configurations of commercially available TDDs, varying dome type (prismatic and clear), diffuser type (Fresnel and prismatic), and diameter (53 and 35 cm), under a range of environmental conditions (different times of day/year, sky cover). Based on illuminance measurements, estimated lighting energy use is also presented. Results indicate that, for clear sky, light levels increase and energy use decreases with solar altitude (e.g., 16 Wh/m 2 daily energy use intensity on a high maximum daily solar altitude (MDSA) day and 34 Wh/m 2 on a low MDSA day) and TDD diameter (e.g., 34 Wh/m 2 and 69 Wh/m 2 for 53 cm and 35 cm TDDs, respectively, for low MDSA). The daily illuminance profile is more rounded for prismatic domes and has higher peaks for clear domes; this translates into a somewhat higher average daily useful daylight illuminance (DUDI) for prismatic domes (86 %) when compared to clear domes (80 %). No clear impact of diffuser type was apparent. In conclusion, measurements indicated no discomfort glare for any of the conditions tested.

14 SOLAR ENERGY↗

Harvesting Daylight

The article discusses daylighting technologies. This article, also, addresses techniques and considerations for implementing daylighting. The energy savings, additional benefits and market potential of daylighting and corresponding technologies are addressed as well.

ASHRAE↗

Measured daylighting potential of a static optical louver system under real sun and sky conditions

Side-by-side comparisons were made over solstice-to-solstice changes in sun and sky conditions between an optical louver system (OLS) and a conventional Venetian blind set at a horizontal slat angle and located inboard of a south-facing, small-area, clerestory window in a full-scale office testbed. Daylight autonomy (DA), window luminance, and ceiling luminance uniformity were used to assess performance. The performance of both systems was found to have significant seasonal variation, where performance under clear sky conditions improved as maximum solar altitude angles transitioned from solstice to equinox. Although the OLS produced fewer hours per day of DA on average than the Venetian blind, the OLS never exceeded the designated 2000 cd/m2 threshold for window glare. In contrast, the Venetian blind was found to exceed the visual discomfort threshold over a large fraction of the day during equinox conditions. Notably, these peak periods of visual discomfort occurred during the best periods of daylighting performance. Luminance uniformity was analyzed using calibrated high dynamic range luminance images. Under clear sky conditions, the OLS was found to increase the luminance of the ceiling as well as produce a more uniform distribution. Furthermore, compared to conventional venetian blinds, the static optical sunlight redirecting system studied has the potential to significantly reduce the annual electrical lighting energy demand of a daylit space and improve the quality from the perspective of building occupants by consistently transmitting useful daylight while eliminating window glare.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Use Intensity and its Influence on the Integrated Daylighting Design of a Large Net Zero Energy Building: Preprint

Net-zero energy buildings generate as much energy as they consume and are significant in the sustainable future of building design and construction. The role of daylighting (and its simulation) in the design process becomes critical. In this paper we present the process the National Renewable Energy Laboratory embarked on in the procurement, design, and construction of its newest building, theResearch Support Facility (RSF) - particularly the roles of daylighting, electric lighting, and simulation. With a rapid construction schedule, the procurement, design, and construction had to be tightly integrated; with low energy use. We outline the process and measures required to manage a building design that could expect to operate at an efficiency previously unheard of for a building ofthis type, size, and density. Rigorous simulation of the daylighting and the electric lighting control response was a given, but the oft-ignored disconnect between lighting simulation and whole-building energy use simulation had to be addressed. The RSF project will be thoroughly evaluated for its performance for one year; preliminary data from the postoccupancy monitoring efforts will also bepresented with an eye toward the current efficacy of building energy and lighting simulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Split-pane electrochromic window control based on an embedded photometric device with real-time daylighting computing

Well-designed electrochromic (EC) glazing control can improve the energy performance of buildings and visual comfort of occupants in highly glazed buildings. Here in this paper, we designed and demonstrated a compact integrated EC glazing automation system to control tint states of a split-pane EC window according to variations of sky conditions. The control is based on monitoring the luminance distribution of the sky and real-time lighting computation for a building interior, using an embedded photometric device (EPD). It optimizes tint states of EC glazing to offer sufficient daylight provision and temper discomfort glare for occupants, which potentially mitigates excessive solar heat gain. ’In-situ’ experiments were conducted in a full-scale testbed to demonstrate the daylighting performance under various sky conditions. Finally, experimental results showed 83% of the working time for work-plane illuminance (WPI) and 95% of the time for daylight glare probability (DGP) were constrained in comfort range (WPIϵ[500, 2000] lux, DGP ≤ 0.35) by the automated EC glazing (controlled by EPD) under clear skies; 68% of the time for WPI and 94% of the time for DGP in confined range under clear skies with thin clouds; 62% of the time for WPI and 85% of the time for DGP in confined range under partly cloudy skies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of sky spectra and sky models in daylighting simulations

Sky models in daylight simulations represent the luminance variation across the sky-dome for different locations, dates, times and weather conditions, but skies are typically modelled as colourless. Recent studies explore techniques for incorporating the spectral content of daylighting in simulations. This paper provides an evaluation of the existing spectral sky models in lighting simulation software. The comparisons are made between the available mathematical sky models and naturally occurring skies that were recorded using high dynamic range photography and spectrophotometric measurements. The results show that recently developed sky models present progress compared to colourless sky models, but further research is needed to accurately simulate daylight spectra.

97 MATHEMATICS AND COMPUTING↗

BSDF Data generation for daylight applications: A call for international standardization

Standardized methods for generating angle-dependent, bidirectional, solar-optical properties for complex fenestration systems do not exist, which means that energy and daylight evaluations in building performance simulations often suffer from major inaccuracies. This position paper provides an overview of state-of-the-art data-driven methods for characterizing light scattering properties of fenestration materials and blind systems (e.g. fabrics, metal slats, patterned glazing), validation via laboratory, simulation and field tests, and salient issues in support of standardization of such methods via the International Standardization Organization (ISO). The ISO standard is intended to provide the fundamental underpinnings for recently mandated daylight standards that rely on bidirectional scattering distribution function data for climate-based daylight modelling and building performance simulations.

Geisler-Moroder, D.↗

Economic analysis of the daylight-linked lighting control system in office buildings

The objective of this study is to perform an economic analysis of the daylight-linked automatic on/off lighting control system installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the energy cost was calculated by using the daylight and building energy analysis simulation. When the lighting control was utilized, an economic analysis was performed using a payback period that was calculated by comparing the initial cost of installing the lighting control system with the annual energy cost which was reduced thanks to the application of the lighting control. The results showed that the lighting energy consumption, when the lighting control was applied, was reduced by an average of 30.5% compared with the case that there was not lighting control applied. Also, the result for total energy consumption showed that, when lighting control was applied, this was reduced by 8.5% when the glazing ratio was 100%, 8.2% for 80%, and 7.6% for 60% when compared to non-application. The payback period was analyzed in terms of the number of floors in a building; 10 floors, 20 floors, 30 floors, and 40 floors. Hence, the building with 40 floors and glazing ratio 100% resulted in the shortest payback period of 8.8 years, the building with 10 floors and glazing ratio 60% resulted in the longest period of 12.7 years. In other words, the larger the glazing ratio and the number of building floors are, the shorter the payback period is. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light-scattering properties of a Venetian blind slat used for daylighting applications

The low cost, simplicity, and aesthetic appearance of external and internal shading devices, make them commonly used for daylighting and glare-control applications. Shading devices, such as Venetian blinds, screens, and roller shades, generally exhibit light scattering and/or light redirecting properties. This requires the bi-directional scattering distribution function (BSDF) of the material to be known in order to accurately predict the daylight distribution and energy flow through the fenestration system. Acquiring the complete BSDF is not a straightforward task, and to complete the process it is often required that a model is used to complement the measured data. In this project, a Venetian blind slat with a white top surface and a brushed aluminum bottom surface was optically characterized. A goniophotometer and an integrating sphere spectrophotometer were used to determine the angle resolved and hemispherical reflectance of the sample, respectively. The acquired data were fitted to a scattering model providing one Lambertian and one angle dependent description of the surface properties. These were used in combination with raytracing to obtain the complete BSDFs of the Venetian blind system. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy 101: Daylighting

Daylighting—the use of windows or skylights for natural lighting and temperature regulation—is one building strategy that can save money for homeowners and businesses. Highly efficient, strategically placed windows maximize the use of natural daylight in a building, lowering the need for artificial lighting without causing heating or cooling problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computer Modeling of Daylight-Integrated Photocontrol of Electric Lighting Systems

This article presents a variety of different approaches to both model and assess the performance of daylight-integrated electric lighting control systems. In these systems, the output of a controlled lighting zone is based on a light sensor reading and a calibrated control algorithm. Computer simulations can consider the simulated illuminance data generated from both the electric lighting system and a daylight delivery system whose performance is addressed using typical meteorological year (TMY) weather data. Photosensor signals and the operation of a control system’s dimming algorithms are also included. Methods and metrics for evaluating simulated performance for the purpose of making informed design decisions that lead to the best possible installed system performance are presented.

Mistrick, Richard↗

The effects on human sleep and circadian rhythms of 17 days of continuous bedrest in the absence of daylight

As part of a larger bedrest study involving various life science experiments, a study was conducted on the effects of 17 days of continuous bedrest and elimination of daylight on circadian rectal temperature rhythms, mood, alertness, and sleep (objective and diary) in eight healthy middle-aged men. Sleep was timed from 2300 to 0700 hours throughout. Three 72-hour measurement blocks were compared: ambulatory prebedrest, early bedrest (days 5-7), and late bedrest (days 15-17). Temperature rhythms showed reduced amplitude and later phases resulting from the bedrest conditions. This was associated with longer nocturnal sleep onset latencies and poorer subjectively rated sleep but with no reliable changes in any of the other sleep parameters. Daily changes in posture and/or exposure to daylight appear to be important determinants of a properly entrained circadian system.

Non-NASA Center↗

Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional Scattering Distribution Functions within Radiance

We describe two methods which rely on bidirectional scattering distribution functions (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater flexibility and accuracy in evaluating arbitrary assemblies of glazing, shading, and other optically-complex coplanar window systems. Two tools within Radiance enable a) efficient annual performance evaluations of CFS, and b) accurate renderings of CFS despite the loss of spatial resolution associated with low-resolution BSDF datasets for inhomogeneous systems. Validation, accuracy, and limitations of the methods are discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗