Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC and AC Electric Fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

ISEE observations of the plasma sheet boundary, plasma sheet, and neutral sheet. I - Electric field, magnetic field, plasma, and ion composition

The first simultaneous study of dc and ac electric and magnetic fields, E x B velocity, plasma flows, ratio of plasma to magnetic field pressure, total energy density, energetic particles, and ion composition from the ISEE satellites and ground and interplanetary magnetic fields has been made to determine (1) the relationship of the previously observed electric fields at the plasma sheet boundary and at the neutral sheet to plasma parameters, and (2) whether the phenomena occurring during quiet and active times were consistent with the formation of a near-earth neutral line during substorms or with the boundary layer model. Five observations made during the study of two substorms were seen to be in agreement with the neutral-line model. The observations are consistent with the satellite being located at varying distances from the neutral line and diffusion region where reconnection and plasma acceleration were occurring. Although the z component (into or out of the ecliptic plane) of E x B convection was generally toward the neutral sheet, there were examples when it was consistent with the inferred motion of the plasma sheet past the satellite. A synthesis of previous reports on large electric fields at the plasma sheet boundary and variable fields at the neutral sheet including the associated plasma flows is also described.

Cattell, C. A.↗

Nanoscale electric field imaging with an ambient scanning quantum sensor microscope

Nitrogen-vacancy (NV) center in diamond is a promising quantum sensor with remarkably versatile sensing capabilities. While scanning NV magnetometry is well-established, NV electrometry has been so far limited to bulk diamonds. Here we demonstrate imaging external alternating (AC) and direct (DC) electric fields with a single NV at the apex of a diamond scanning tip under ambient conditions. A strong electric field screening effect is observed at low frequencies. We quantitatively measure its frequency dependence and overcome this screening by mechanically oscillating the tip for imaging DC fields. Our scanning NV electrometry achieved an AC E-field sensitivity of 26 mV μm -1 Hz -1/2 , a DC E-field gradient sensitivity of 2 V μm -2 Hz -1/2 , and sub-100 nm resolution limited by the NV-sample distance. Our work represents an important step toward building a scanning-probe-based multimodal quantum sensing platform.

47 OTHER INSTRUMENTATION↗

Real-time dynamic wavelength tuning and intensity modulation of metal-clad nanolasers

To realize ubiquitously used photonic integrated circuits, on-chip nanoscale sources are essential components. Subwavelength nanolasers, especially those based on a metal-clad design, already possess many desirable attributes for an on-chip source such as low thresholds, room-temperature operation and ultra-small footprints accompanied by electromagnetic isolation at pitch sizes down to ∼50 nm. Another valuable characteristic for a source would be control over its emission wavelength and intensity in real-time. Most efforts on tuning/modulation thus far report static changes based on irreversible techniques not suited for high-speed operation. In this study, we demonstrate in-situ dynamical tuning of the emission wavelength of a metallo-dielectric nanolaser at room temperature by applying an external DC electric field. Using an AC electric field, we show that it is also possible to modulate the output intensity of the nanolaser at high speeds. The nanolaser’s emission wavelength in the telecom band can be altered by as much as 8.35 nm with a tuning sensitivity of ∼1.01 nm/V. Additionally, the output intensity can be attenuated by up to 89%, a contrast sufficient for digital data communication purposes. Finally, we achieve an intensity modulation speed up to 400 MHz, limited only by the photodetector bandwidth used in this study, which underlines the capability of high-speed operation via this method. This is the first demonstration of a telecom band nanolaser source with dynamic spectral tuning and intensity modulation based on an external E-field to the best of our knowledge.

Deka, Suruj S. (ORCID:0000000297812317)↗

Design and Modelling of a Microfluidic Electro-Lysis Device with Controlling Plates

Many Lab-on-Chip applications require sample pre-treatment systems. Using electric fields to perform cell-lysis in bio-MEMS systems has provided a powerful tool which can be integrated into Lab-on-a-Chip platforms. The major design considerations for electro-lysis devices include optimal geometry and placement of micro-electrodes, cell concentration, flow rates, optimal electric field (e.g. pulsed DC vs. AC), etc. To avoid electrolysis of the flowing solution at the exposed electrode surfaces, magnitudes and the applied voltages and duration of the DC pulse, or the AC frequency of the AC, have to be optimized for a given configuration. Using simulation tools for calculation of electric fields has proved very useful, for exploring alternative configurations and operating conditions for achieving electro cell-lysis. To alleviate the problem associated with low electric fields within the microfluidics channel and the high voltage demand on the contact electrode strips, two "control plates" are added to the microfluidics configuration. The principle of placing the two controlling plate-electrodes is based on the electric fields generated by a combined insulator/dielectric (gladwater) media. Surface charges are established at the insulator/dielectric interface. This paper discusses the effects of this interface charge on the modification of the electric field of the flowing liquid/cell solution.

Jenkins, A.↗

Radiation Belt Storm Probe (RBSP) Mission

Scheduled to launch in May 2012, NASA's dual spacecraft Living With a Star Radiation Belt Storm Probe mission carries the field and particle instrumentation needed to determine the processes that produce enhancements in radiation belt ion and electron fluxes, the dominant mechanisms that cause the loss of relativistic electrons, and the manner by which the ring current and other geomagnetic phenomena affect radiation belt behavior. The two spacecraft will operate in low-inclination elliptical lapping orbits around the Earth, within and immediately exterior to the Van Allen radiation belts. During course of their two year primary mission, they will cover the full range of local times, measuring both AC and DC electric and magnetic fields to 10kHz, as well as ions from 50 eV to 1 GeV and electrons with energies ranging from 50 eV to 10 MeV.

Sibeck, D. G.↗

A statistical approach to analyzing domain dynamics in ferroelectric crystals using X-ray photon correlation spectroscopy

Ferroelectric materials exhibit strong electromechanical coupling, largely influenced by their domain structures. Numerous microstructural studies indicate that smaller domains with higher domain wall density generally enhance domain wall motion, although some inconsistencies have been reported. In this work, we use X-ray photon correlation spectroscopy (XPCS) to probe dynamic response in Pb(Mg 1/3 Nb 2/3 )O 3 -29PbTiO 3 (PMN-29PT) single crystals under applied electric fields. We introduce a two-field correlation approach, adapted from conventional two-time correlation to quantify dynamics. Statistical analysis reveals that both [001]-oriented direct current (DC) and alternating current (AC) poled samples show Poisson-like behavior within specific electric field regions. The DC-poled samples exhibit more frequent domain wall jump events but with smaller amount of decorrelation per jump event, whereas the AC-poled samples show fewer jump events with larger decorrelation per jump event. This observation aligns with the prevalence of 109° domain walls in the AC-poled samples, which contribute to more domain wall motion. These findings provide experimental evidence of collective domain wall motion and establish a direct connection between mesoscale dynamics and electromechanical response.

36 MATERIALS SCIENCE↗

The resolved layer of a collisionless, high beta, supercritical, quasi-perpendicular shock wave. I - Rankine-Hugoniot geometry, currents, and stationarity

Data collected by the ISEE dual-spacecraft mission (on November 7, 1977) on a slowly moving, supercritical, high-beta, quasi-perpendicular bow shock are presented, and the local geometry, spatial scales, and stationarity of this shock wave are assessed in a self-consistent Rankine-Hugoniot-constrained frame of reference. Included are spatial profiles of the ac and dc magnetic and electric fields, electron and proton fluid velocities, current densities, electron and proton number densities, temperatures, pressures, and partial densities of the reflected protons. The observed layer profile is shown to be nearly phase standing and one-dimensional in a Rankine-Hugoniot frame, empirically determined by the magnetofluid parameters outside the layer proper.

Scudder, J. D.↗

An Overview of Scientific and Space Weather Results from the Communication/Navigation Outage Forecasting System (C/NOFS) Mission

The Communication/Navigation Outage Forecasting System (C/NOFS) Mission of the Air Force Research Laboratory is described. C/NOFS science objectives may be organized into three categories: (1) to understand physical processes active in the background ionosphere and thermosphere in which plasma instabilities grow; (2) to identify mechanisms that trigger or quench the plasma irregularities responsible for signal degradation; and (3) to determine how the plasma irregularities affect the propagation of electromagnetic waves. The satellite was launched in April, 2008 into a low inclination (13 deg), elliptical (400 x 850 km) orbit. The satellite sensors measure the following parameters in situ: ambient and fluctuating electron densities, AC and DC electric and magnetic fields, ion drifts and large scale ion composition, ion and electron temperatures, and neutral winds. C/NOFS is also equipped with a GPS occultation receiver and a radio beacon. In addition to the satellite sensors, complementary ground-based measurements, theory, and advanced modeling techniques are also important parts of the mission. We report scientific and space weather highlights of the mission after nearly four years in orbit

Pfaff, R.↗

Small Radioisotope Power System Testing at NASA Glenn Research Center

In April 2009, NASA Glenn Research Center (GRC) formed an integrated product team (IPT) to develop a Small Radioisotope Power System (SRPS) utilizing a single Advanced Stirling Convertor (ASC) with passive balancer. A single ASC produces approximately 80 We making this system advantageous for small distributed lunar science stations. The IPT consists of Sunpower, Inc., to provide the single ASC with a passive balancer, The Johns Hopkins University Applied Physics Laboratory (JHUAPL) to design an engineering model Single Convertor Controller (SCC) for an ASC with a passive balancer, and NASA GRC to provide technical support to these tasks and to develop a simulated lunar lander test stand. The single ASC with a passive balancer, simulated lunar lander test stand, and SCC were delivered to GRC and were tested as a system. The testing sequence at GRC included SCC fault tolerance, integration, electromagnetic interference (EMI), vibration, and extended operation testing. The SCC fault tolerance test characterized the SCCs ability to handle various fault conditions, including high or low bus power consumption, total open load or short circuit, and replacing a failed SCC card while the backup maintains control of the ASC. The integrated test characterized the behavior of the system across a range of operating conditions, including variations in cold-end temperature and piston amplitude, including the emitted vibration to both the sensors on the lunar lander and the lunar surface. The EMI test characterized the AC and DC magnetic and electric fields emitted by the SCC and single ASC. The vibration test confirms the SCCs ability to control the single ASC during launch. The extended operation test allows data to be collected over a period of thousands of hours to obtain long term performance data of the ASC with a passive balancer and the SCC. This paper will discuss the results of each of these tests.

Vibration↗

Stirling Convertor Controller Development at NASA Glenn Research Center

For nearly two decades, NASA Glenn Research Center (GRC) has been supporting the development of Radioisotope Power Systems (RPS). NASA desires higher conversion efficiency RPS options that are reliable and robust with long life design. Dynamic conversion, such as Stirling and Brayton, offer the potential for higher conversion efficiencies than current RPS but have yet to be demonstrated in a flight application. The RPS program sent out a solicitation to investigate options for dynamic conversion technologies. As a result of this solicitation, four dynamic power convertor (DPC) technologies were selected for design and three are proceeding to the fabrication phase of prototype dynamic convertors. One lesson learned from the Advanced Stirling Radioisotope Generator (ASRG) project is that controller development should be coordinated with the development of a dynamic convertor. As a result of this, NASA GRC has been utilizing hardware from past Stirling convertor projects including that of the ASRG to support controller development for the DPC's. NASA GRC has developed a strong knowledge base on both analog and digital Stirling dynamic power convertor controllers and will continue to expand and apply that knowledge to the DPC's. Over the past 15 years, controllers were developed at GRC, at Lockheed Martin (LM) and by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL). Various generations of the controllers have been developed as lessons were learned through various component and system level tests. Some of the tests performed were fault tolerance, flight acceptance vibration, electromagnetic interference (EMI), spacecraft integration, and extended operation. The fault tolerance test characterized the controller's ability to handle various fault conditions, including high or low bus power consumptions, total open load or short circuit, and replacing a failed controller card while the backup maintains control of the Stirling convertor. The vibration test confirms the controller's ability to control an ASC during launch. The EMI test characterized the AC and DC magnetic and electric fields emitted by the single ASC and if the controller has an impact on the radiated EMI. Spacecraft integration testing in the Radioisotope Power Systems System Integration Laboratory (RSIL) provided insight into the electrical interactions between the representative RPS, its associated control schemes, and realistic electric system loads. The extended operation test allows data to be collected over a period of thousands of hours to obtain long term performance data of the system. This paper describes the history of controller development at NASA GRC, tests performed on these controllers, and lessons learned.

Dugala, Gina M.↗

Stirling Convertor Controller Development at NASA Glenn Research Center

Over the past decade, NASA Glenn Research Center (GRC) has been supporting the development of Radioisotope Power Systems (RPS). NASA desires higher conversion efficiency RPS options that are reliable and robust with long life design. Dynamic conversion, such as Stirling and Brayton, offer the potential for higher conversion efficiencies but have yet to be demonstrated in a flight application. The RPS program sent out a solicitation to investigate options for dynamic conversion technologies. As a result of this solicitation, four dynamic power convertor (DPC) technologies were selected for design and fabrication of a prototype dynamic convertor. One lesson learned from the Advanced Stirling Radioisotope Generator (ASRG) project is that controller development should start early in the development of a dynamic convertor. As a result of this, NASA GRC has been utilizing hardware from past Stirling convertor projects including that of the ASRG to support controller development for the DPC's. NASA GRC has developed a strong knowledge base on both analog and digital Stirling dynamic power convertor controllers and will continue to expand and apply that knowledge to the four DPC's. Over the past 15 years, controllers were developed in-house at GRC, at Lockheed Martin Coherent Technologies (LMCT) and by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL). Various generations of the controllers, have been developed as lessons were learned through various component and system level tests. Some of the tests performed were fault tolerance, qualification vibration level, electromagnetic interference, Radioisotope Power System Systems Integration (RSIL) tests, and extended operation. The fault tolerance test characterized the controller's ability to handle various fault conditions, including high or low bus power consumptions, total open load or short circuit, and replacing a failed controller card while the backup maintains control of the ASC. The vibration test confirms the controller's ability to control an ASC during launch. The EMI test characterized the AC and DC magnetic and electric fields emitted by the single ASC and if the controller has an impact on the radiated EMI. RSIL testing provided insight into the electrical interactions between the representative RPS, its associated control schemes, and realistic electric system loads. The extended operation test allows data to be collected over a period of thousands of hours to obtain long term performance data of the system. This paper describes the history of controller development at NASA GRC, tests performed on these controllers, and lessons learned.

Dugala, Gina M.↗

High Voltage Power Supply Design Guide for Space

This book is written for newcomers to the topic of high voltage (HV) in space and is intended to replace an earlier (1970s) out-of-print document. It discusses the designs, problems, and their solutions for HV, mostly direct current, electric power, or bias supplies that are needed for space scientific instruments and devices, including stepping supplies. Output voltages up to 30kV are considered, but only very low output currents, on the order of microamperes. The book gives a brief review of the basic physics of electrical insulation and breakdown problems, especially in gases. It recites details about embedment and coating of the supplies with polymeric resins. Suggestions on HV circuit parts follow. Corona or partial discharge testing on the HV parts and assemblies is discussed both under AC and DC impressed test voltages. Electric field analysis by computer on an HV device is included in considerable detail. Finally, there are many examples given of HV power supplies, complete with some of the circuit diagrams and color photographs of the layouts.

Bever, Renate S.↗

Electric field and fine structure in aurora.

Simultaneous rocket measurements of electric field and optical aurora during a weak PCA event are presented. The aurora consisted of faint structures superposed on a homogeneous glow, and on-board photometers showed that the rocket passed through two discrete auroral forms. These enhanced auroral emissions coincided with variations in the dc electric field and an increase in the ac field. A detailed comparison between electric fields and optical emissions shows that the relation is quite complex. The results are compared with earlier electric field and optical auroral measurements.

Maseide, K.↗

Stirling Convertor Controller Development at NASA Glenn Research Center

For nearly two decades, NASA Glenn Research Center has been supporting the development of radioisotope power systems (RPS). NASA desires higher conversion efficiency RPS options that are reliable and robust with long-life design. Dynamic conversion, such as Stirling and Brayton, offer the potential for higher conversion efficiencies than current RPS but have yet to be demonstrated in a flight application. The RPS program sent out a solicitation to investigate options for dynamic conversion technologies. As a result of this solicitation, four dynamic power convertor (DPC) technologies were selected for design and three are proceeding to the fabrication phase of prototype dynamic convertors. One lesson learned from the Advanced Stirling Radioisotope Generator (ASRG) project is that controller development should be coordinated with the development of a dynamic convertor. As a result of this, Glenn has been utilizing hardware from past Stirling convertor projects, including that of the ASRG, to support controller development for the DPCs. Glenn has developed a strong knowledge base on both analog and digital Stirling DPC controllers and will continue to expand and apply that knowledge to the DPCs. Over the past 15 years, controllers were developed at Glenn, at Lockheed Martin (LM), and by the Johns Hopkins University Applied Physics Laboratory (APL). Various generations of the controllers have been developed as lessons were learned through various component- and system-level tests. Some of the tests performed were fault tolerance, flight acceptance vibration, electromagnetic interference (EMI), spacecraft integration, and extended operation. The fault tolerance test characterized the controller’s ability to handle various fault conditions, including high or low bus power consumption, total open load or short circuit, and replacing a failed controller card while the backup maintains control of the Stirling convertor. The vibration test confirms the controller’s ability to control an Advanced Stirling Convertor (ASC) during launch. The EMI test characterized the alternating-current (AC) and direct-current (DC) magnetic and electric fields emitted by the single ASC and if the controller has an impact on the radiated EMI. Spacecraft integration testing in the Radioisotope Power Systems (RPS), System Integration Laboratory (RSIL) provided insight into the electrical interactions between the representative RPS, its associated control schemes, and realistic electric system loads. The extended operation test allows data to be collected over a period of thousands of hours to obtain long-term performance data of the system. This paper describes the history of controller development at Glenn, tests performed on these controllers, and lessons learned.

Dugala, Gina M.↗

Electrical Charging Hazards Originating from the Surface (ECHOS): Understanding the Martian Electro-Meteorological Environment

In 1999, the NASA/Human Exploration and Development of Space (HEDS) enterprise selected a number of payloads to fly to the Martian surface in an 03 opportunity (prior to the MPL loss). Part of a proposed experiment, ECHOS, was selected to specifically understand the electrical charging hazards from tribocharged dust in the ambient atmosphere, in dust devils, and in larger storms. It is expected that Martian dust storms become tribocharged much like terrestrial dust devils which can possess almost a million elementary charges per cubic centimeter. The ECHOS package features a set of instruments for measuring electric effects: a radio to detect AC electric fields radiating from discharges in the storm,a DC electric field system for sensing electrostatic fields from concentrations of charged dust grains, and a lander electrometer chain for determining the induced potential on its body and MAV (Mars Ascent Vehicle) during the passages of a charged dust storm. Given that electricity is a systemic process originating from wind-blown dust, we also proposed to correlate the electrical measurements with fundamental fluid/meteorological observations, including wind velocity and vorticity, temperature, and pressure. Triboelectricity will also affect local chemistry, and chemical-sensing devices were also considered a feature of the package. The primary HEDS objectives of the ECHOS sensing suite is to discover and monitor the natural electrical hazards associated with dust devils and storms, and determine their enviro-effectiveness on human systems. However, ECHOS also has a strong footprint in the overarching science objectives of the Mars Surveyor Program.

Farrell, W. M.↗

External Magnetic Field Reduction Techniques for the Advanced Stirling Radioisotope Generator

Linear alternators coupled to high efficiency Stirling engines are strong candidates for thermal-to-electric power conversion in space. However, the magnetic field emissions, both AC and DC, of these permanent magnet excited alternators can interfere with sensitive instrumentation onboard a spacecraft. Effective methods to mitigate the AC and DC electromagnetic interference (EMI) from solenoidal type linear alternators (like that used in the Advanced Stirling Convertor) have been developed for potential use in the Advanced Stirling Radioisotope Generator. The methods developed avoid the complexity and extra mass inherent in data extraction from multiple sensors or the use of shielding. This paper discusses these methods, and also provides experimental data obtained during breadboard testing of both AC and DC external magnetic field devices.

Thermoelectric Power Generation↗

Development of a dual-field heteropoplar power converter

The design and testing of a 400 watt, dual phase, dual rotor, field modulated inductor alternator is described. The system is designed for use as a flywheel to ac utility line or flywheel to dc bus (electric vehicle) power converter. The machine is unique in that it uses dual rotors and separately controlled fields to produce output current and voltage which are in phase with each other. Having the voltage and current in phase allows the power electronics to be made of simple low cost components. Based on analytical predictions and experimental results, development of a complete 22 kilowatt (30 Hp) power conversion system is recommended. This system would include power electronics and controls and would replace the inductor alternator with an improved electromagnetic conversion system.

Eisenhaure, D. B.↗

Enhanced domain dynamics in alternating current poled rhombohedral Pb(Mg 1/3 Nb 2/3 )O 3 –PbTiO 3 single crystals

Abstract The understanding of domain dynamics in ferroelectric materials is crucial for optimizing their performance in piezoelectric and electro‐optic applications. Although previous studies have focused on static domain structures and macroscopic characteristics, the time‐resolved approach of domains remains largely unexplored. In this study, we compare the dynamic responses of direct current (DC) and alternating current (AC) poled [001]‐oriented rhombohedral Pb(Mg 1/3 Nb 2/3 )O 3 –PbTiO 3 (PMN–PT) single crystals using X‐ray photon correlation spectroscopy (XPCS) during the application of external electric fields. Our results demonstrate that the AC‐poled sample exhibit enhanced reconfiguration of domain variants in response to driving fields compared to the DC‐poled counterpart, as evidenced by accelerated correlation decay and faster relaxation time. This phenomenon is attributed to enhanced reversible domain wall motion achieved through AC poling, which facilitates field‐induced domain realignment. These findings provide insight into the relationship between dynamics and macroscopic properties in relaxor‐PT single crystals for high‐performance applications.

36 MATERIALS SCIENCE↗