Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC magnetics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electron paramagnetic resonance study of alinement induced by magnetic fields in two smectic-A liquid crystals not exhibiting nematic phases

Using vanadyl acetylacetonate (VAAC) as a paramagnetic probe, the molecular ordering in two smectic-A liquid crystals that do not display nematic phases were studied. Reproducible alinement was attained by slow cooling throughout the isotropic smectic-A transition in dc magnetic fields of 1.1 and 2.15 teslas. The degree of order attained is small for a smectic-A liquid crystal. Measurements were made of the variation of the average hyperfine splitting of the alined samples as a function of orientation relative to the dc magnetic field of the spectrometer. This functional dependence is in agreement with the theoretical prediction except where the viscosity of the liquid crystal becomes large enough to slow the tumbling of the VAAC, as indicated by asymmetry in the end lines of the spectrum.

Fryburg, G. C.↗

Lower hybrid emission diagnostics on the NASA Lewis bumpy torus

The feasibility of using RF emission near the lower hybrid frequency of the NASA Lewis Bumpy Torus plasma for diagnostic purposes is examined. The emission is detected using a spectrum analyzer and a 50 omega miniature coaxial antenna that is sensitive to the polarization of the incoming signal. The frequency shift of the lower hybrid emission peak is monitored as a function of the background pressure, electrode voltage, electrode ring configuration and the strength of the toroidal dc magnetic field. Simultaneous measurements of the average plasma density are made with a polarization diplexing microwave interferometer. Data derived from the experiment are discussed with reference to the following: (1) the strength of the dc magnetic field in the emitting region; (2) comparison of the lower hybrid plasma density with the average plasma density; and (3) validity of the cold plasma lower hybrid resonance formula in the high density operating regime of the bumpy torus plasma.

Mallavarpu, R.↗

Investigation of possible lower hybrid emission from the NASA Lewis Bumpy Torus plasma

Radio frequency emission detected near the lower hybrid frequency of the NASA Lewis Bumpy Torus plasma is studied, using a simple detection system that consists of a spectrum analyzer and a 50-ohm miniature co-axial antenna concentrically located in a re-entrant quartz tube. The frequency shift of a broad emission peak is monitored as a function of the background pressure, electrode voltage, and the strength of the dc magnetic field. Simultaneous measurements of the average plasma density are made with a polarization diplexing microwave interferometer. Information from the experiment is discussed with particular reference to the role of atomic or molecular species of deuterium in the emissions, the strength of the dc magnetic field in the emitting region, the geometric location of the emitting region of the plasma, the lower hybrid plasma density as compared with the average plasma density, and the relation of the ion spoke geometry to the lower hybrid emission.

Mallavarpu, R.↗

Investigation of possible lower hybrid emission from the NASA Lewis bumpy torus plasma

Radio frequency emission has been detected near the power hybrid frequency of a bumpy torus plasma by using a responsive detection system that consists of a spectrum analyzer and a 50 ohm miniature coaxial antenna concentrically located in a re-entrant quartz tube. The frequency shift of a broad emission peak was monitored as a function of background pressure, electrode voltage, and the strength of the dc magnetic field. Simultaneous measurements of the average plasma density were made with a polarization diplexing microwave interferometer. The information derived from the experiment is discussed with particular reference to the following: (1) whether the emissions are dominated by atomic or molecular species of deuterium; (2) the strength of the dc magnetic field in the emitting region; (3) the geometric location of the emitting region of the plasma; (4) comparison of the lower hybrid plasma density with the average plasma density; and (5) relation of ion spoke geometry to lower hybrid emission.

Mallavarpu, R.↗

Lower hybrid emission diagnostics on the NASA Lewis Bumpy Torus

The feasibility of using RF emission near the lower-hybrid frequency of the NASA Lewis Bumpy Torus plasma for diagnostic purposes is examined. The emission is detected using a spectrum analyzer and a 50-ohm miniature coaxial antenna that is sensitive to the polarization of the incoming signal. The frequency shift of the lower-hybrid emission peak is monitored as a function of the background pressure, electrode voltage, electrode ring configuration, and the strength of the toroidal dc magnetic field. Simultaneous measurements of the average plasma density are made with a polarization diplexing microwave interferometer. The experimental results extend previous work to include negative electrode voltages and plasma densities up to 1 trillion per cu cm. The information derived from the experiment is discussed with reference to: (1) the strength of the dc magnetic field in the emitting region, (2) a comparison of the lower-hybrid plasma density with the average plasma density, and (3) the validity of the cold-plasma lower-hybrid resonance formula in the high-density operating regime of the bumpy-torus plasma.

Mallavarpu, R.↗

Potential damage to dc superconducting magnets due to high frequency electromagnetic waves

Studies of a d.c. superconducting magnet coil indicate that the large coil behaves as a straight waveguide structure. Voltages between layers within the coil sometimes exceeded those recorded at terminals where protective resistors are located. Protection of magnet coils against these excessive voltages could be accomplished by impedance matching throughout the coil system. The wave phenomenon associated with superconducting magnetic coils may create an instability capable of converting the energy of a quiescent d.c. superconducting coil into dissipative a.c. energy, even in cases when dielectric breakdown does not take place.

Gabriel, G. J.↗

The development of a magnetically enhanced hydrogen gas dissociation

Application of a dc magnetic field on an RF hydrogen gas dissociator led to the development of a more efficient source of atoms for hydrogen masers. The influence of the applied magnetic field on the plasma and some details of the resulting enhancement of the dissociation efficiency are discussed. Ways that this improved efficiency can result in the enhancement of the operation and field life of hydrogen masers, as well as aid the development of spaceborne masers, are considered.

Maleki, L.↗

Magnetostatic Cleanliness of the Radioistope Thermoelectric

This paper describes the field-mapping technique, the numerical modeling and the compensation approach used for the RTGs with the goal of minimizing its magnetic field interference with Cassini's DC magnetic field science instruments.

Magnetics RTG Cassini↗

Survival of itinerant excitations and quantum spin state transitions in YbMgGaO 4 with chemical disorder

A recent focus of quantum spin liquid (QSL) studies is how disorder/randomness in a QSL candidate affects its true magnetic ground state. The ultimate question is whether the QSL survives disorder or the disorder leads to a “spin-liquid-like” state, such as the proposed random-singlet (RS) state. Since disorder is a standard feature of most QSL candidates, this question represents a major challenge for QSL candidates. YbMgGaO 4 , a triangular lattice antiferromagnet with effective spin-1/2 Yb 3+ ions, is an ideal system to address this question, since it shows no long-range magnetic ordering with Mg/Ga site disorder. Despite the intensive study, it remains unresolved as to whether YbMgGaO 4 is a QSL or in the RS state. Here, through ultralow-temperature thermal conductivity and magnetic torque measurements, plus specific heat and DC magnetization data, we observed a residual κ 0 /T term and series of quantum spin state transitions in the zero temperature limit for YbMgGaO 4 . These observations strongly suggest that a QSL state with itinerant excitations and quantum spin fluctuations survives disorder in YbMgGaO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetism of single crystalline breathing pyrochlore spinel AgInCr 4 ⁢S 8

Single crystals of Ag⁢In⁢Cr 4⁢ S 8 are grown by chemical vapor transport and crystallographic ordering of Ag/In that results in a breathing pyrochlore motif of Cr 3+ is verified by x-ray and neutron diffraction. Long-range antiferromagnetic order is observed below a Néel temperature of 𝑇 N ≈ 9.6 K. The magnetic properties are characterized using ac and dc magnetization, specific heat capacity, and single crystal neutron diffraction measurements. The specific heat data are characterized by a small lambda anomaly near 9.5 K and the estimated magnetic entropy reaches ≈ $\frac{1}{3}$ of the expected value by 3⁢𝑇 N , suggesting significant short-range order in the paramagnetic phase. Single crystal neutron diffraction evidences an incommensurate spin structure with propagation vector 𝒌 = (0,0,𝛿) and 𝛿 = 0.343 at 5 K. The minimal model that accounts for the data consists of ferromagnetic layers of Cr atoms, with magnetic moments lying in the plane of the layers and modulating in the perpendicular direction to form a helical structure propagating along 𝒌. Furthermore, this study represents a rare investigation of single crystals within the family of breathing pyrochlore materials.

Frustrated magnetism↗

Transport critical current and magnetization measurements of melt-processed YBa2Cu3O(7-x)

This paper reports on the magnetic field dependence of the transport critical current and dc magnetic susceptibility measurements on YBa2Cu3O(7-x) superconductors formed by melt-solid reactions at 950 C between Ba-Cu-O (or Tb-Ba-cu-O) and solid nonstoichiometric Y-Ba-Cu oxide. Four-probe dc critical current measurements at 77, 64, and 4.2 K show strong depression of the critical current density with increasing magnetic field, in agreement with a model of weakly linked superconducting regions. Diamagnetic shielding and Meissner flux expulsion measurements in the temperature range 10-300 K show about one-third volume fraction of perfect superconductivity. Both shielding and flux expulsion were observed to be approximately temperature independent below 60 K, indicating strong coupling between the grains throughout the entire volume below this temperature.

Hermann, A. H.↗

Analysis of payload bay magnetic fields due to dc power multipoint and single point ground configurations

An analysis of magnetic fields in the Orbiter Payload Bay resulting from the present grounding configuration (structure return) was presented and the amount of improvement that would result from installing wire returns for the three dc power buses was determined. Ac and dc magnetic fields at five points in a cross-section of the bay are calculated for both grounding configurations. Y and Z components of the field at each point are derived in terms of a constant coefficient and the current amplitude of each bus. The dc loads assumed are 100 Amperes for each bus. The ac noise current used is a spectrum 6 db higher than the Orbiter equipment limit for narrowband conducted emissions. It was concluded that installing return wiring to provide a single point ground for the dc Buses in the Payload Bay would reduce the ac and dc magnetic field intensity by approximately 30 db.

Lawton, R. M.↗

Three-dimensional plasma diffusion in a very strong magnetic field.

The thermal equilibrium coefficient of spatial diffusion transverse to a strong uniform dc magnetic field is calculated for a fully ionized plasma. The particles are assumed to move transverse to the field only as a consequence of the E x B drift, but to move freely parallel to it. The particles interact only electrostatically. The calculation is done at large, but fixed and finite, plasma volume. It is shown that, as magnetic field density approaches infinity, the leading term of the coefficient of transverse spatial diffusion falls off in a prescribed manner, but contains a multiplicative factor which goes to zero as the plasma volume becomes infinite. The method of calculation fails for unbounded plasmas.

Montgomery, D.↗

Magnetic flux imaging in a 3D superconductor integrated circuit

We report on imaging magnetic flux distributions in a multilayered superconductor integrated circuit which emerge during magnetization and after field cooling of the circuit in the DC magnetic field. The obtained complicated field maps expose the flux propagation across the patterned superconducting ground planes sandwiching layers with Josephson junction-based logic cells, fine wire grid around the functional units, and multiple superconducting fill structures located in different inner layers. The observed intricate flux distributions are explained by specific patterns of Meissner screening currents and superconducting critical currents in different mutually interacting parts of the integrated circuit. Our results provide important insights into possible ways of improving the protection of superconductor integrated circuits from magnetic fields and their resilience against flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnets are Weber Bar Gravitational Wave Detectors

When a gravitational wave (GW) passes through a dc magnetic field, it couples to the conducting wires carrying the currents which generate the magnetic field, causing them to oscillate at the GW frequency. The oscillating currents then generate an ac component through which the GW can be detected-thus forming a resonant mass detector or a nagnetic Weber bar. We quantify this claim and demonstrate that magnets can have exceptional sensitivity to GWs over a frequency range demarcated by the mechanical and electromagnetic resonant frequencies of the system; indeed, we outline why a magnetic readout strategy can be considered an optimal Weber bar design. The concept is applicable to a broad class of magnets, but can be particularly well exploited by the powerful magnets being deployed in search of axion dark matter, for example, by DMRadio and ADMX-EFR. Explicitly, we demonstrate that the MRI magnet that is being deployed for ADMX-EFR can achieve a broadband GW strain sensitivity of ∼10^{-20}/sqrt[Hz] from a few kHz to about 10 MHz, with a peak sensitivity down to ∼10^{-22}/sqrt[Hz] at a kHz exploiting a mechanical resonance.

Domcke, Valerie↗