At least 37 records · Page 2

Precursor Analysis Report: Ryuk Ransomware Attack on Universal Health Services 2020

The Ryuk Ransomware Attack on Universal Health Services (UHS) 2020 Precursor Analysis Report leverages publicly available information about the 2020 UHS cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. UHS manages over 400 hospitals and is one of the largest healthcare providers in the United States with 3.5 million patients each year. On 27 September 2020, UHS suffered a widespread ransomware attack that resulted in a denial of service to critical internet-dependent healthcare systems including workstations, phones, and data centers. Employees resorted to filing patient details with pen and paper, while other facilities had to redirect ambulances and urgent patients to other facilities for adequate care. Adversaries carried out the attack with Ryuk, a ransomware that encrypts data and generates a RyukReadMe.txt ransom note with the ransom fee to decrypt the data, varying from 15 Bitcoin (BTC) to 50 BTC, equivalent to roughly $\$$353,892 to $\$$964,617. UHS did not pay the ransom and was able to recover data through backups, but still reported an impact of $\$$67 million dollars in recovery costs. On 29 October, one month after the attack, UHS made an official statement that their systems had been restored and they were resuming normal operations. Researchers and analysts identified 18 unique techniques (used in a sequence of 19 steps) utilized during the attack with a total of 185 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fourteen of the identified techniques used during the UHS cyber attack were precursors to the triggering event. Analysis identified 106 observables associated with these precursor techniques, 82 of which were assessed to have an increased likelihood of being perceived in the 30 days to two hours preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

Evaluating software defined networking solutions to reduce the digital attack surface of nuclear security systems

Most nuclear security systems used today were not designed for today’s threat environment. Systems that were intended to be stand alone are now interconnected. Devices that have a single purpose are built on multi-purpose platforms and communication protocols that, while effective, have no ability to authenticate authorized versus unauthorized commands. These attributes provide an attacker significant ability to affect the system, pivot throughout the interconnected networks, and remain undetected if he/she is able to compromise a single node. Software defined networking (SDN) has been used for years by information technology (IT) cloud service providers to quickly provision or remove servers or other systems to meet changing demand. The same concept has recently been applied to operational technology (OT) systems to enable very fast failover on critical systems that have stringent and deterministic (<5ms) transmit/receive times. By carefully engineering the communication flows through a network using preplanned routes and specific pathways it is possible to achieve deterministic and extremely reliable message delivery even when components fail. This engineering approach to network design has added security benefits including securing the networking control plane, eliminating network scanning and mapping, inhibiting ARP spoofing and host masquerading, eliminating unauthorized network pivoting and enabling greater situational awareness on the network. SDN in OT environments is new but early testing in electrical power and other critical infrastructure has shown it to be a very powerful tool for building reliable networks and reducing the digital attack surface of the network. The authors tested a software defined network switch on a simple physical protection system with components commonly found in nuclear security systems and found improved mitigations to denial of service attacks, lateral movement and network reconnaissance. The paper details the tests and their results.

Cyber security, Nuclear security, software defined↗

Security Assessment of an LBP16-Protocol-Based Computer Numerical Control Machine

Subtractive manufacturing systems, specifically, computer numerical control machines, have revolutionized the manufacturing industry. Computer numerical control machining is the preferred method for producing finished parts due to its efficiency, speed and suitability for high-volume production. Securing computer numerical control machines is a priority. Compromises or disruptions of these machines can result in significant downtime, loss of productivity and financial loss. This study examines the vulnerabilities and risks associated with computer numerical control machines, in particular, systems utilizing the LBP16 protocol for controller-machine communications. The study reveals that an adversary can execute cyber-physical attacks such as sabotage and denial of service. The potential security threats emphasize the importance of implementing robust security measures to mitigate the cyber risks to computer numerical control machines.

Forihat, Yahya [Virginia Commonwealth University, ↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility of critical infrastructure protection using network functions for programmable and decoupled ICS policy enforcement over WAN

Industrial control systems (ICS) represent a major component of our critical infrastructure. With the increasing need for more control and monitoring of such systems, ICS have seen an increase in connectivity to wide area networks (WAN) exposing aging equipment to rapidly evolving cybersecurity threats. Furthermore, the ICS data requires a reliability measure from the networks for critical functions for infrastructure monitoring and control. Especially when remote plant sites are involved such as pipelines, energy distribution networks, and transportation, WAN transport impairments most often provide a best effort delivery with no strict reliability guarantees. Network functions can provide a vendor agnostic, programmable critical infrastructure protection with a single maintenance, policy determination, and reliability assurance surface. A network function (NF) can be utilized for policy enforcement over the communication between remote entities and the main control office. This paper presents the research on transparent integration with existing ICS without disrupting communications, resulting in minimal downtime while decoupling the fast paced evolution of defensive security measures from the upgrade cycle of expensive long term hardware. We report our measurements on the resource requirements and overhead in the network for successful NF insertion under a wide variety of network impairments (network packet delay, reordering, and loss). Our paired NF implementation provides a policy enforcement platform extensible to cover myriad cybersecurity-related communication goals, including packet signing for verification, encryption for data privacy, packet filtering and data diode operation (i.e. protecting against eavesdropping, packet injection, and denial-of-service). Furthermore, bundling communication specifications into packet flows allows for tunability in applying policies as coarse- or fine-grained as the needs of the operator. We report on network function resource requirements in the form of required queue depth and network utilization overhead to inform the decision making against hardware cost constraints.

42 ENGINEERING↗

Design and evaluation of a cyber‐physical testbed for improving attack resilience of power systems

Abstract A power system is a complex cyber‐physical system whose security is critical to its function. A major challenge is to model, analyse and visualise the communication backbone of the power systems concerning cyber threats. To achieve this, the design and evaluation of a cyber‐physical power system (CPPS) testbed called Resilient Energy Systems Lab (RESLab) are presented to capture realistic cyber, physical, and protection system features. RESLab is architected to be a fundamental platform for studying and improving the resilience of complex CPPS to cyber threats. The cyber network is emulated using Common Open Research Emulator (CORE), which acts as a gateway for the physical and protection devices to communicate. The physical grid is simulated in the dynamic time frame using Power World Dynamic Studio (PWDS). The protection components are modelled with both PWDS and physical devices including the SEL Real‐Time Automation Controller (RTAC). Distributed Network Protocol 3 (DNP3) is used to monitor and control the grid. Then, the design is exemplified and the tools are validated. This work presents four case studies on cyberattack and defence using RESLab, where we demonstrate false data and command injection using Man‐in‐the‐Middle and Denial of Service attacks and validate them on a large‐scale synthetic electric grid.

Sahu, Abhijeet↗

FL‐ADS: Federated learning anomaly detection system for distributed energy resource networks

Abstract With the ongoing development of Distributed Energy Resources (DER) communication networks, the imperative for strong cybersecurity and data privacy safeguards is increasingly evident. DER networks, which rely on protocols such as Distributed Network Protocol 3 and Modbus, are susceptible to cyberattacks such as data integrity breaches and denial of service due to their inherent security vulnerabilities. This paper introduces an innovative Federated Learning (FL)‐based anomaly detection system designed to enhance the security of DER networks while preserving data privacy. Our models leverage Vertical and Horizontal Federated Learning to enable collaborative learning while preserving data privacy, exchanging only non‐sensitive information, such as model parameters, and maintaining the privacy of DER clients' raw data. The effectiveness of the models is demonstrated through its evaluation on datasets representative of real‐world DER scenarios, showcasing significant improvements in accuracy and F1‐score across all clients compared to the traditional baseline model. Additionally, this work demonstrates a consistent reduction in loss function over multiple FL rounds, further validating its efficacy and offering a robust solution that balances effective anomaly detection with stringent data privacy needs.

Purohit, Shaurya [Iowa State University Ames Iowa ↗

Cross-Layered Distributed Data-Driven Framework for Enhanced Smart Grid Cyber-Physical Security

Smart Grid (SG) research and development has drawn much attention from academia, industry and government due to the great impact it will have on society, economics and the environment. Securing the SG is a considerably significant challenge due the increased dependency on communication networks to assist in physical process control, exposing them to various cyber-threats. In addition to attacks that change measurement values using False Data Injection (FDI) techniques, attacks on the communication network may disrupt the power system's real-time operation by intercepting messages, or by flooding the communication channels with unnecessary data. Addressing these attacks requires a cross-layer approach. In this paper a cross-layered strategy is presented, called Cross-Layer Ensemble CorrDet with Adaptive Statistics(CECD-AS), which integrates the detection of faulty SG measurement data as well as inconsistent network inter-arrival times and transmission delays for more reliable and accurate anomaly detection and attack interpretation. Numerical results show that CECD-AS can detect multiple False Data Injections, Denial of Service (DoS) and Man In The Middle (MITM) attacks with a high F1-score compared to current approaches that only use SG measurement data for detection such as the traditional physics-based State Estimation, Ensemble CorrDet with Adaptive Statistics strategy and other machine learning classification-based detection schemes.

cyber-physical security↗

Virtual Agents-Based Attack-Resilient Distributed Control for Islanded AC Microgrid

Due to its dependence on a communication network, distributed secondary control of microgrids is susceptible to denial-of-service (DoS) attacks in channel shutdown mode, which may negatively impact the network connectivity and thus deteriorate the coordination and power sharing among distributed generators (DGs). Honeypot is a common method for cyber deception by introducing fake targets. However, in the context of microgrid, the misleading information spread by honeypots will also impact the system performance. This paper proposes an attack-resilient distributed control for AC microgrids utilizing virtual agents (VAs) to counteract both DoS edge and node attacks. The VAs are designed to not impact the system’s steady state during normal operation but to share information among neighboring real agents and serve as dummy targets for DoS attacks. The control with VAs is implemented by a primal-dual gradient based distributed algorithm to efficiently obtain a practical solution for voltage/frequency regulation and power sharing. The simulation results on a 4-DG test system and a modified IEEE 34-bus system show that 1) VAs do not impact the normal functionality of the test system, and 2) deploying VAs can enhance the resilience of the microgrid control against DoS edge and node attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Cyber Defense Against Dynamic Multi-strategy Infrastructural DDoS Attacks

Dynamic Infrastructural Distributed Denial of Service (I-DDoS) attacks constantly change attack vectors to congest core backhaul links and disrupt critical network availability while evading end-system defenses. To effectively counter these highly dynamic attacks, defense mechanisms need to exhibit adaptive decision strategies for real-time mitigation. This paper presents a novel Autonomous DDoS Defense framework that employs model-based reinforcement agents. The framework continuously learns attack strategies, predicts attack actions, and dynamically determines the optimal composition of defense tactics such as filtering, limiting, and rerouting for flow diversion. Our contributions include extending the underlying formulation of the Markov Decision Process (MDP) to address simultaneous DDoS attack and defense behavior, and accounting for environmental uncertainties. We also propose a fine-grained action mitigation approach robust to classification inaccuracies in Intrusion Detection Systems (IDS). Additionally, our reinforcement learning model demonstrates resilience against evasion and deceptive attacks. Evaluation experiments using real-world and simulated DDoS traces demonstrate that our autonomous defense framework ensures the delivery of approximately 96 - 98% of benign traffic despite the diverse range of attack strategies.

Dutta, Ashutosh↗

Moving Target Defense Routing for SDN-enabled Smart Grid

The increasing attack surface area in the smart grid communication networks is making the grid more susceptible to cyber attacks that can lead to instability of the grid and even blackouts. While there are multiple types of cyber attacks that can impact the grid, Denial of Service (DoS) attacks are relatively easier to inject as they require lesser knowledge about the system as compared to data integrity attacks. Various research works showcase methods to prevent or mitigate the impacts of DoS attacks in the smart grid but the research still lacks in demonstrating the feasibility and efficacy of the solutions in a real-world environment. In this paper, we propose a Moving Target Defense (MTD)-enabled Software Defined Network (SDN) for the Smart Grid communication implemented on a Hardwarein- the-Loop (HIL) Testbed. We showcase the implementation of the proposed architecture of MTD-enabled SDN using Mininet 2.3.0 which enables communication between the physical grid and the control center. The results show the advantages of using MTD based on SDN for the wide-area network (WAN) with much lower packet drop percentages in the case of MTD-based routing in the SDN WAN. Index Terms—SDN,

97 MATHEMATICS AND COMPUTING↗

A Typology of Quantum-Classical Faults

This paper introduces an extended taxonomy of faults specific to hybrid quantum-classical systems, addressing the unique challenges that arise from integrating quantum accelerators into high-performance computing (HPC) infrastructures. Building on the foundational fault classification by Avizienis et al., we incorporate fault types unique to quantum computing-such as qubit decoherence, spontaneous gate errors, and photon loss-alongside traditional and human-induced faults including development errors, operational mistakes, and malicious attacks. Our taxonomy classifies faults by their origin (natural vs. human-made), intent (accidental, deliberate non-malicious, or malicious), system boundaries (internal vs. external), and persistence (transient to permanent). We also explore how different architectural integration patterns-ranging from tight coupling to loose on-premise and cloud-based configurations-shape the manifestation and propagation of faults. These scenarios are analyzed in terms of timing mismatches, interface inconsistencies, and security threats such as data tampering and denial-of-service attacks. Through this fault-centric lens, we aim to support the co-design of dependable quantum-classical systems and highlight the critical role that integration strategies play in ensuring reproducibility, resilience, and security across hybrid computing platforms.

Giusto, Edorado [University of Naples Federico II,↗

Time Sequence Machine Learning-Based Data Intrusion Detection for Smart Voltage Source Converter-Enabled Power Grid

Smart inverters of distributed energy resources can enable cloud computing, condition monitoring, result visualization, remote control, and peer-to-peer energy trading in advanced power systems. However, the advent of data injection attacks in the communication architecture can alter measurement characteristics of power grids and have devastating consequences. In this article, we propose a time sequence machine learning-based anomaly detection methodology for detecting cyber intrusion into control signal setpoints and dc voltage signal measurement bias of the voltage source converter (VSC) in wind generators. We first investigated the effects of four types of denial of service, tampering signal, and stealthy-type data intrusion attacks on smart VSCs and overall wind farms. We then proposed a novel time sequence machine learning-based intrusion detection framework that can be implemented to detect different cyberattacks in the VSCs. The performance of the proposed framework has been compared with that of autoencoder and clustering-based intrusion detection framework. The proposed framework was validated by using the IEEE 39 bus power system in the presence of four wind farms in different locations. Using several metrics for intrusion detection performance, we validated the effectiveness of the proposed framework.

42 ENGINEERING↗

Cybersecurity Challenges in Low-Inertia Power-Electronics-Dominated Grids

Here, the low inertia characteristics of the power electronics dominated grid (PEDG) introduces challenges while restoring voltage and frequency to their nominal values. These stability challenges create new cybersecurity vulnerabilities that are not thoroughly discussed in the literature. Cyber events such as false data injection (FDI), denial of service (DoS), man-in-the-middle attacks, stealthy attacks, and advanced persistent threats target PEDG to disrupt grid stability or gain financial benefits. The low inertia of PEDG (< 2s) compared to traditional grids (~10s) exacerbates these vulnerabilities. In response to stealthy attacks on state variables that supervisory layers cannot detect until significant harm occurs, the low inertia characteristics of PEDG offer substantial stealthy attack surfaces. To counteract such threats, PEDG must be equipped with ultra-fast real-time anomaly detection system and trajectory prediction mechanism to achieve effective cyberattack resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insecurity of Wireless Networks

Wireless is a powerful core technology enabling our global digital infrastructure. Wi-Fi networks are susceptible to attacks on Wired Equivalency Privacy, Wi-Fi Protected Access (WPA), and WPA2. These attack signatures can be profiled into a system that defends against such attacks on the basis of their inherent characteristics. Wi-Fi is the standard protocol for wireless networks used extensively in US critical infrastructures. Since the Wired Equivalency Privacy (WEP) security protocol was broken, the Wi-Fi Protected Access (WPA) protocol has been considered the secure alternative compatible with hardware developed for WEP. However, in November 2008, researchers developed an attack on WPA, allowing forgery of Address Resolution Protocol (ARP) packets. Subsequent enhancements have enabled ARP poisoning, cryptosystem denial of service, and man-in-the-middle attacks. Open source systems and methods (OSSM) have long been used to secure networks against such attacks. This article reviews OSSMs and the results of experimental attacks on WPA. These experiments re-created current attacks in a laboratory setting, recording both wired and wireless traffic. The article discusses methods of intrusion detection and prevention in the context of cyber physical protection of critical Internet infrastructure. The basis for this research is a specialized (and undoubtedly incomplete) taxonomy of Wi-Fi attacks and their adaptations to existing countermeasures and protocol revisions. Ultimately, this article aims to provide a clearer picture of how and why wireless protection protocols and encryption must achieve a more scientific basis for detecting and preventing such attacks.

99 GENERAL AND MISCELLANEOUS↗

Novel control solutions for DoS attack delay mitigation in grid-connected and standalone inverters

This paper introduces two novel control solutions, which allow localised delay compensation for grid-connected and standalone inverters. As the prediction horizon of the existing controllers are quite small as compared to large communication delays and information unavailability due to denial-of-service (DoS) attacks, the proposed strategy offers a robust delay mitigation range using localized dynamics. Its design philosophy is leveraged via a prediction policy using the inner control loop dynamics. Based on different control objectives in grid-connected and standalone mode, the proposed solutions have been augmented into the control system accordingly. Finally, its robustness under various communication delay and DoS attacks have been tested.

Roig Greidanus, Mateo D.↗

Identification of a Delay Attack in the Secondary Control of Grid-Tied Inverter Systems

This work is developed for the identification of a denial-of-service cyberattack on the secondary controller of inverter systems which is connected to the power grid. The identification is made through the dynamic response of the reactive power (Q) of the system under attack. By observing the dynamic characteristic of Q, it is possible to correlate the attack with the nominal response of the hierarchical controller. The article shows that the occurrence of the attack can be identified through a supervisory control that runs a model in parallel. The article argues that after an early identification of the attack, a local controller can take action to mitigate its effects on the system’s response.

Roig Greidanus, Mateo D.↗