Search NASA⌕ Search

SEARCH · Search NASA

Results for “DORIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Combined Weekly Coordinate Solutions from SLR and DORIS

In International Terrestrial Reference Frame (ITRF) 2005 and ITRF2008, the approach for the construction of solutions by the IERS has been for individual analysis centers of each technique to process geodetic tracking data, and for each technique to develop a solution (or contribution) that is integrated into the final ITRF solution by careful combination of the technique solutions. The connections between the geodetic networks are realized by the application of local ties. In an alternate approach, we may assure processing homogeneity by creating normal equations for different techniques with the same orbit determination software, using identically derived algorithms. Another derivative of this approach is to realize the ties between the techniques using satellites tracked with multiple techniques; in effect tieing the networks together using satellite dynamics. In this solution, we develop a time series and a set of cumulative solutions from Satellite Laser Ranging (SLR) & Doppler Orbitography and Radio-positioning Integrated by Satellite (DORIS) based on homogeneous processing with the NASA GEODYN precise orbit determination suite of programs, where we jointly combine weekly the SLR data to Lageos1, Lageos2, Starlette, and Stella with the DORIS data from SPOT2-SPOT5, as well as satellites that utilize both techniques (TOPEX/Poseidon, Envisat, Jason-2). We discuss the modeling that is applied including upgrades implemented since the submission of the GSC ITRF2008 contributions for IDS. Firstly, we compare the SLR-only solutions comprising four geodetic satellites with the standard approach of utilizing only Lageos1 & Lageos2. Secondly, we evaluate the impact on the DORIS coordinates of the joint analysis with the SLR data.

Lemoine, F.↗

Research Activities for the DORIS Contribution to the Next International Terrestrial Reference Frame

For the preparation of ITRF2008, the IDS processed data from 1993 to 2008, including data from TOPEX/Poseidon, the SPOT satellites and Envisat in the weekly solutions. Since the development of ITRF2008, the IDS has been engaged in a number of efforts to try and improve the reference frame solutions. These efforts include (i) assessing the contribution of the new DORIS satellites, Jason-2 and Cryosat2 (2008-2011), (ii) individually analyzing the DORIS satellite contributions to geocenter and scale, and (iii) improving orbit dynamics (atmospheric loading effects, satellite surface force modeling. . . ). We report on the preliminary results from these research activities, review the status of the IDS combination which is now routinely generated from the contributions of the IDS analysis centers, and discuss the prospects for continued improvement in the DORIS contribution to the next international reference frame.

Soudarin, L.↗

The proposed international DORIS service

The goal of this paper is to discuss the status of the DORIS Pilot experiment, to analyze the progress made during the past two years and to propose the official creation within the IAG of an International DORIS Service (IDS).

DORIS IDS International DORIS Service IGGOS↗

Looking for systematic error in scale from terrestrial reference frames derived from DORIS data

The long-term stability of the scale of Terrestrial Reference Frames is directly linked with station height determination and is critical for several scientific studies, such as global mean sea level rise or ocean circulation with consequences on global warming studies. In recent International Terrestrial Reference Frame solutions, the DORIS technique was not sonsidered able to provide any useful information on scale. We have analyzed three different DORIS time series of coordinates performed independently using different software packages.

Terrestrial Reference Frame (TRF)↗

Status of DORIS stations in Antarctica for precise geodesy

In Antarctica, besides the quite numerous GPS stations, four DORIS stations are permanently operating. In addition to the permanent DORIS stations, episodic campaigns took place at DomeC/Conccordia and on Sorsdal and Lambert glaciers. In this paper, we first collect general information concerning the stations and the campaigns (location, start of measurements, etc). We then present the results of observations of the permanent stations keeping in mind that we are primarily interested here in the vertical component, which is the most uncertain component.

Antarctica↗

DORIS weekly solutions: status report and open problems

Since the official start of the International DORIS Service (IDS) in 2003, several Analysis Centers have submitted time series of station coordinates in SINEX format. We discuss here the different DORIS weekly solutions available for ITRF 2004 and for the IERS Combinationa Campaign Project.

DORIS↗

Real-time on-board orbit determination with DORIS

A spaceborne orbit determination system is being developed by the French Space Agency (CNES) for the SPOT 4 satellite. It processes DORIS measurements to produce an orbit with an accuracy of about 50O meters rms. In order to evaluate the reliability of the software, it was combined with the MERCATOR man/machine interface and used to process the TOPEX/Poseidon DORIS data in near real time during the validation phase of the instrument, at JPL and at CNES. This paper gives an overview of the orbit determination system and presents the results of the TOPEX/Poseidon experiment.

Berthias, J.-P.↗

The DORIS Data Center at the CDDIS

The DORIS system (Doppler Orbitography and Radio positioning Integrated by Satellite) was designed and developed by CNES, the National Geographic Institute, IGN (Institut G6ographique National), and the Space Geodesy Research Group, GRGS (Groupe de Recherches de Geodesie Spatiale - CNES/CNRS/Universite Paul Sabatier) to meet new needs for the precise determination of satellite positions on their orbits and for precise positioning of terrestrial beacons. This system has been carried since 1990 on the French SPOT 2 satellite, since 1992 on the French/American satellite TOPEX/POSEIDON, and since 1998 on the French SPOT 4 satellite. It will be part of the JASON (CNES/NASA) and ENVISAT (ESA) altimetric missions and also the SPOT follow-on Earth observation missions. DORIS is a radio-electrical system which takes Doppler measurements between a satellite in low orbit and a permanent global network for the purpose, on the one hand, of determining the satellite's position in orbit, and on the other hand, of locating ground beacons with a high degree of precision.

Noll, Carey E.↗

JASON-1 Precise Orbit Determination (POD) Through the Combination and Comparison of GPS, SLR, DORIS and Altimeter Crossover Data

Jason-1, launched on December 7,2001, is continuing the time series of centimeter level ocean topography observations as the follow-on to the highly successful TOPEX/POSEIDON (T/P) radar altimeter satellite. The precision orbit determination (POD) is a critical component to meeting the ocean topography goals of the mission. T P has demonstrated that the time variation of ocean topography can be determined with an accuracy of a few centimeters, thanks to the availability of highly accurate orbits based primarily on SLR+DORIS tracking. The Jason-1 mission is intended to continue measurement of the ocean surface with the same, if not better accuracy. Fortunately, Jason- 1 POD can rely on four independent tracking data types available including near continuous tracking data from the dual frequency codeless BlackJack GPS receiver. Orbit solutions computed using individual and various combinations of GPS, SLR, DORIS and altimeter crossover data types have been determined from over 100 days of Jason-1 tracking data, The performance of the orbit solutions and tracking data has been evaluated. Orbit solution evaluation and comparison has provided insight into possible areas of refinement. Several aspects of the POD process are examined to obtain orbit improvements including measurement modeling, force modeling and solution strategy. The results of these analyses will be presented.

Luthcke, Scott B.↗

JASON-1 Precise Orbit Determination (POD) Through the Combination and Comparison of GPS, SLR, DORIS and Altimeter Crossover Data

Jason-1, launched on December 7, 2001, is continuing the time series of centimeter level ocean topography observations as the follow-on to the highly successful TOPEX/POSEIDON (T/P) radar altimeter satellite. The precision orbit determination (POD) is a critical component to meeting the ocean topography goals of the mission. T/P has demonstrated that the time variation of ocean topography can be determined with an accuracy of a few centimeters, thanks to the availability of highly accurate orbits based primarily on SLR+DORIS tracking. The Jason-1 mission is intended to continue measurement of the ocean surface with the same, if not better accuracy. Fortunately, Jason-1 POD can rely on four independent tracking data types available including near continuous tracking data from the dual frequency codeless BlackJack GPS receiver. Orbit solutions computed using individual and various combinations of GPS, SLR, DORIS and altimeter crossover data types have been determined from over 100 days of Jason-1 tracking data. The performance of the orbit solutions and tracking data has been evaluated. Orbit solution evaluation and comparison has provided insight into possible areas of refinement. Several aspects of the POD process are examined to obtain orbit improvements including measurement modeling, force modeling and solution strategy. The results of these analyses will be presented.

Luthcke, S. B.↗

IVS Tropospheric Parameters: Comparison with DORIS and GPS for CONT02

In April 2002 the IVS (International VLBI Service for Geodesy and Astrometry) set up the Pilot Project - Tropospheric Parameters, and the Institute of Geodesy and Geophysics (IGG), Vienna, was put in charge of coordinating the project. Seven IVS Analysis Centers have joined the project and regularly submitted their estimates of tropospheric parameters (wet and total zenith delays, horizontal gradients) for all IVS-R1 mid IVS-R4 sessions since January 1st, 2002. The individual submissions are combined by a two-step procedure to obtain stable, robust and highly accurate tropospheric parameter time series with one hour resolution (internal accuracy: 2-4 ram). Starting with July 2003, the combined tropospheric estimates became operational IVS products. In the second half of October 2002 the VLBI campaign CONT02 was observed with 8 stations participating around the globe. At four of them (Gilmore Creek, U.S.A.; Hartebeesthoek, South Africa; Kokee Park, U.S.A.; Ny-Alesund, Norway) also total zenith delays from DORIS (Doppler Orbitography and Radiopositioning Integrated by Satellite) are available and these estimates are compared with those from the IGS (International GPS Service) and the IVS. The distance from the DORIS beacons to the co-located GPS and VLBI stations is around 2 km or less for the four sites mentioned above.

Schuh, Harald↗

The Global GNSS, SLR, VLBI, and DORIS Networks and their Support of GGOS: IGS+ILRS+IVS+IDS

The global network of the International GNSS Service (IGS), the International Laser Ranging Service (ILRS), the International VLBI Service for Geodesy and Astrometry (IVS), and the International DORIS Service (IDS) are part of the ground-based infrastructure for GGOS. The observations obtained from these global networks provide for the determination and maintenance of the International Terrestrial Reference Frame (ITRF), an accurate set of positions and velocities that provides a stable coordinate system allowing scientists ts to link measurements over space and time. Many of these sites offer co-location of two or more techniques. Co-location provides integration of technique-specific networks into the ITRF as well as an assessment/validation of the quality and accuracy of the resulting measurements. As of fall 2008, these networks consisted of 410 GNSS sites, 42 laser ranging sites, 45 VLBI sites, and 58 DORIS sites. This poster will illustrate the global coverage of these networks, highlighting inter-technique co-locations, and show the importance of these networks 60 the underlying goals of GGOS including providing the observational basis to maintain a stable, accurate, global reference frame.

Noll, Carey↗

Vertical Crustal Motion Derived from Satellite Altimetry and Tide Gauges, and Comparisons with DORIS Measurements

A somewhat unorthodox method for determining vertical crustal motion at a tide-gauge location is to difference the sea level time series with an equivalent time series determined from satellite altimetry, To the extent that both instruments measure an identical ocean signal, the difference will be dominated by vertical land motion at the gauge. We revisit this technique by analyzing sea level signals at 28 tide gauges that are colocated with DORIS geodetic stations. Comparisons of altimeter-gauge vertical rates with DORIS rates yield a median difference of 1.8 mm/yr and a weighted root-mean-square difference of2.7 mm/yr. The latter suggests that our uncertainty estimates, which are primarily based on an assumed AR(l) noise process in all time series, underestimates the true errors. Several sources of additional error are discussed, including possible scale errors in the terrestrial reference frame to which altimeter-gauge rates are mostly insensitive, One of our stations, Male, Maldives, which has been the subject of some uninformed arguments about sea-level rise, is found to have almost no vertical motion, and thus is vulnerable to rising sea levels. Published by Elsevier Ltd. on behalf of COSPAR.

Ray, R. D.↗

International DORIS Service (IDS): The IDS at 20 and the IVS at 25; Together on a Long Journey

This is an invited presentation to the the IVS General Meeting 2024 to celebrate the 25th anniversary of the International VLBI Service (IVS). The presentation shares aspects of the common journey of the International DORIS Service (IDS), and IVS over the last 20 years, as sibling services of the International Association of Geodesy, and as space geodetic techniques that contribute to the International Terrestrial Reference Frame (ITRF).

DORIS↗

DORIS as a potential part of a global geodetic observing system

We have processed all available DORIS data from all available satellites, except JASON over the past 10 years. Weekly solutions have been produced for stations positions coordinates, geocenter motion and scale factor stability. We present here the current accuracy presently achievable for all types of potential geodetic products.

DORIS Fairbanks Terrestrial Reference Frame GPS↗

Set-up of an XAFS beamline for measurements between 2.4-8 keV at DORIS III

In this paper results from the commissioning phase and from first user experiments of a new EXAFS beamline at the DORIS III storage ring are presented. The bending magnet EXAFS beamline A1 underwent a complete rebuild and now covers the energy range 2.4-8 keV. A Ni-coated toroidal mirror, placed in a 2:1 focusing position and a plane mirror with one Ni coated stripe and one uncoated (SiO{sub 2}) stripe are used for effective higher harmonics suppression and focusing. The UHV-compatible fixed-exit Double Crystal Monochromator (DCM) is equipped with two Si(111) crystal pairs. The second crystal of one of the two crystal pairs is tilted by 90 deg. around the surface normal to shift the position of glitches. It allows Bragg angles between 5 deg. and 55.5 deg. and continuous scans in quick-EXAFS mode. Test measurements during the commissioning phase proved the excellent performance of the monochromator and a high quality of the XAFS spectra over the entire working range.

43 PARTICLE ACCELERATORS↗

Note: Comparison of grazing incidence small angle x-ray scattering of a titania sponge structure at the beamlines BW4 (DORIS III) and P03 (PETRA III)

Grazing incidence small angle x-ray scattering (GISAXS) is a powerful technique for morphology investigation of nanostructured thin films. GISAXS measurements at the newly installed P03 beamline at the storage ring PETRA III in Hamburg, Germany, are compared to the GISAXS data from the beamline BW4 at the storage ring DORIS III, which had been used extensively for GISAXS investigations in the past. As an example, a titania thin film sponge structure is investigated. Compared to BW4, at beamline P03 the resolution of larger structures is slightly improved and a higher incident flux leads to a factor of 750 in scattered intensity. Therefore, the acquisition time in GISAXS geometry is reduced significantly at beamline P03.

43 PARTICLE ACCELERATORS↗