Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSIMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

Empirical evidence that mean soil contaminant concentration is not a conservative indicator of external exposure to wildlife

Adequate information on external exposure is often a limiting factor in ecological risk assessments because of a lack of exposure data for free-ranging animals as they interact with a heterogeneous distribution of contaminants. Instead, most wildlife exposure data are estimated from model simulations. However, empirical exposure data are rarely available to verify model results, or to test fundamental assumptions inherent in exposure assessments. We used novel, GPS-coupled radiation dosimeters on reindeer (Rangifer tarandus) to quantify their external exposure for five months in a Chernobyl fallout affected mountainous area of Norway. The exposure data were then used to test a fundamental assumption in screening-level risk assessments: Mean soil contaminant concentrations can be used to conservatively estimate chronic external exposures to representative animals. External exposure and GPS coordinates were obtained hourly and compared to model simulations of exposure based on airborne surveys of 137 Cs soil contamination. Our objectives were to determine 1) if modelled dose estimates based on mean 137 Cs soil concentrations were conservative, and 2) if modelled dose estimates could be improved by adjusting for spatial–temporal heterogeneity of contaminants using 137 Cs concentrations within reindeers’ GPS-defined home ranges and core areas. We found that external exposure modelled from mean soil contaminant concentrations underestimated exposure by 70% compared to empirical measurements from GPS-dosimeter collars worn on individual animals. Using area-weighted mean contaminant levels within the animals’ home range improved the model estimates, but still underestimated the field dosimeter data by 53%. The best estimate of external exposure was obtained when high-use areas within their home range, along with spatial heterogeneity of the contaminant, was accounted for by using area-weighted mean soil contaminant levels within GPS-derived core areas. Accounting for temporal use of core areas within animals’ home range provided a 24% improvement. Here, a comparison of our analyses to similar work performed on Chernobyl wolves found the two studies concur that risk assessors should be cautious in relying on the paradigm of using averaged soil contaminant levels to provide conservative estimates of external exposure to representative individuals. Results of modelled external exposure based on mean soil contaminant concentrations could misguide assessors and cause inappropriate management decisions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Review of Pantex Radiation Safety Department 2020 Backup Dosimetry Processing Methodology

In the first quarter (Q1) of Calendar Year 2020, the Pantex Radiation Safety Department (Pantex) experienced various issues and failures with their dosimeter processing equipment. Efforts to repair the equipment resulted in limited functionality without the ability to process dosimeters assigned to personnel for monitoring dose. As a result of the impairments to the dosimeter processing equipment, Pantex called upon Nevada National Security Site (NNSS) for support, as their designated backup processor. In January of 2021, LLNL Subject Matter Experts in External Dosimetry started an NNSA-requested review of Pantex’s personnel doses in Q1 2020. Its focus was the technical validity of the means and methods used by Pantex and its conclusions and provide a level of confidence to National Nuclear Security Administration (NNSA) that the resulting personnel doses were reasonable, conservative, and defensible.

61 RADIATION PROTECTION AND DOSIMETRY↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermoluminescence and optically stimulated luminescence response of Al 2 O 3 coatings deposited by mist-chemical vapor deposition

Aluminum oxide (Al 2 O 3 ) is a widely used ceramic material which can be applied as a protective coating on metallic structures to improve corrosion resistance and mechanical properties. Al 2 O 3 also has great potential as a functional thin film device in optoelectronics. When it is doped with carbon (Al 2 O 3 :C), this material system can serve as a reliable radiation dosimeter. The combination of optoelectronic, dosimetric, and protective properties demonstrated by Al 2 O 3 uniquely positions it for dual use applications in nuclear forensics, nonproliferation and safeguards, emergency response, retrospective dosimetry, and nondestructive inspection. Here, in this study, an innovative ultrasonic mist-chemical vapor deposition (Mist-CVD) system was used to deposit thin (nm level) Al 2 O 3 coatings on 304 stainless steel substrates. The single aliquot regeneration (SAR) and additive dose reconstruction techniques were then used to investigate the thermoluminescence (TL) and optically stimulated luminescence (OSL) response of the coated substrates to increasing doses of β irradiation. This study demonstrates that nm-thick Al 2 O 3 coatings hold promise as novel nano-dosimeters which could be leveraged for a series of applications such as nonproliferation and safeguards, retrospective dosimetry, and nondestructive inspection.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytical Bit-Error Model of NAND Flash Memories for Dosimetry Application

In this work, we provide an analytical model for the total ionizing dose (TID) effects on the bit error statistics of commercial flash memory chips. We have validated the model with experimental data collected by irradiating several commercial NAND flash memory chips from different technology nodes. We find that our analytical model can project bit errors at higher TID values (~ 20 krad(Si)) from measured data at lower TID values (<1 krad(Si)). Based on our model and the measured data, we have formulated basic design rules for using a commercial flash memory chip as a dosimeter. We discuss the impact of NAND chip-to-chip variability, noise margin and the intrinsic errors on the dosimeter design using detailed experimentation.

3-D NAND↗

Characterization of B255 R183 C-Cell Cobalt-60 Irradiator Pool

Characterization of the Radiation Calibration and Spectroscopy Laboratory (RCS) Co-60 source radiation pool was successfully completed. The characterization was done by performing several measurements of dose rate in the center of the Co-60 source radiation pool and at multiple heights from the bottom of the pool. The measurements were taken between November 2018 through January 2019. Opti-Chromic FWT-70-40M dosimeters were used for this measurement. A 7.3 cm inner diameter stainless steel cylinder (vessel) was used to lower the dosimeters to the bottom of the pool inside the 16 cm dimeter Co-60 source basket. The dose rate was measured at heights of 5.5, 12, 19, and 23 cm from the bottom of the pool. The report “Tour of the Standards and Calibration Laboratory” includes information about the Co-60 source radiation pool. The importance of performing the Co-60 source characterization is to confirm previously reported Co-60 source dose rate measurements and to provide a documented measuring procedure for researchers and others who want to use the Co-60 source to evaluate the effects of radiation on space-based equipment for other applications. The measured dose rate at the abovementioned heights was 0.65, 0.69, 0.53, 0.23 krad/min respectively with the highest coefficient of variation of less than 10%.

61 RADIATION PROTECTION AND DOSIMETRY↗

IER-484 CED4a Report: AFRRI ER1 Dosimetry Characterization

This report presents an analytical function as the reference neutron and photon dose (normalized to an ion chamber integral) for future nuclear accident dosimeter (NAD) exercise at the Armed Forces Radiobiology Research Institute (AFRRI). Various dosimeters and equipment were positioned within exposure room 1 (ER1) and irradiated using a 1.1 MW Training, Research, Isotope, General Atomics (TRIGA) Mark-F nuclear reactor. An ion chamber located in ER1 was used as a normalization factor in Equation 2. This allows for a quick calculation of neutron and photon dose based on the ion chamber data. Currently, AFRRI is in preparation to host a NAD exercise this summer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗