30 records · Page 2

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

Bayes_Opt-SWMM: A Gaussian process-based Bayesian optimization tool for real-time flood modeling with SWMM

Real-time flood model plays a pivotal role in averting urban flood damage, particularly when there is minimal lead time for preparatory measures. However, urban flood modeling in real-time often contends with inherent uncertainties arising from input data uncertainty and parameter ambiguities. Here this study introduces a real-time calibration (RTC) tool called Bayes_Opt-SWMM, specifically tailored for real-time urban flood modeling and uncertainty optimization. This tool leverages the Gaussian process-based Bayesian optimization algorithm and interfaces seamlessly with the Stormwater Management Model (SWMM). It integrates real-time model forcing data and flood monitoring collected through sensors and gauges which are strategically placed within critical locations of urban drainage systems. Our approach hinges on the Surrogate Model based Uncertainty Optimization (SMUO) concept, providing an avenue for enhancing real-time flood modeling. Bayes_Opt-SWMM runs the optimization process using a surrogate model called Gaussian Process emulator with two inference methods: (1) the Gaussian Process (GP) model and (2) Markov Chain Monte Carlo (MCMC) algorithm in GP model (GP_MCMC). Furthermore, three acquisition functions, namely Expected Improvement (EI), Maximum Probability of Improvement (MPI), and Lower Confidence Bound (LCB), facilitate optimal parameter fitting within the surrogate models. The efficiency of GP-based surrogate models in learning SWMM model parameters, leads to an improved uncertainty quantification and accelerated real-time flood modeling in urban areas. Overall, Bayes_Opt-SWMM emerges as a cost-effective and valuable tool for real-time flood modeling and monitoring, with significant potential for managing intelligent storm water systems in urban environments.

54 ENVIRONMENTAL SCIENCES↗

Diverse fates of ancient horizontal gene transfers in extremophilic red algae

Abstract Horizontal genetic transfer (HGT) is a common phenomenon in eukaryotic genomes. However, the mechanisms by which HGT‐derived genes persist and integrate into other pathways remain unclear. This topic is of significant interest because, over time, the stressors that initially favoured the fixation of HGT may diminish or disappear. Despite this, the foreign genes may continue to exist if they become part of a broader stress response or other pathways. The conventional model suggests that the acquisition of HGT equates to adaptation. However, this model may evolve into more complex interactions between gene products, a concept we refer to as the ‘Integrated HGT Model’ (IHM). To explore this concept further, we studied specialized HGT‐derived genes that encode heavy metal detoxification functions. The recruitment of these genes into other pathways could provide clear examples of IHM. In our study, we exposed two anciently diverged species of polyextremophilic red algae from the Galdieria genus to arsenic and mercury stress in laboratory cultures. We then analysed the transcriptome data using differential and coexpression analysis. Our findings revealed that mercury detoxification follows a ‘one gene‐one function’ model, resulting in an indivisible response. In contrast, the ars H gene in the arsenite response pathway demonstrated a complex pattern of duplication, divergence and potential neofunctionalization, consistent with the IHM. Our research sheds light on the fate and integration of ancient HGTs, providing a novel perspective on the ecology of extremophiles.

59 BASIC BIOLOGICAL SCIENCES↗

A New Inelastic Neutron Spectrometer HODACA

In this study, a new multiplex-type inelastic neutron scattering spectrometer, HOrizontally Defocusing Analyzer Concurrent data Acquisition spectrometer (HODACA), was recently developed and built at the C1-1 cold neutron beam port in the neutron source reactor JRR-3 at Japan Atomic Energy Agency. The spectrometer is suitable for dynamics measurements in the energy range of -1 meV ≲ ℏω ≲ 7 meV, catering to a broad array of research fields in physics and material science. HODACA combines 24 detectors and 132 pieces of analyzer crystals and has an estimated measurement efficiency that is 70 times greater than the existing conventional triple-axis spectrometer at the C1-1 beam port. The concept, design, specification, and results of commissioning experiments are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward Unified Autonomous Scattering Experiments: A Cross-Facility Case Study at ALS and PETRA III

Autonomous experiments rely on the integration of control, data acquisition, analysis, and decision-making frameworks. While such systems have been demonstrated at individual facilities, adapting them to additional instruments remains challenging due to differences in local infrastructure. We present a modular workflow that connects existing open-source tools for data access (Tiled), workflow orchestration (Prefect), analysis and visualization (pyFAI, Plotly Dash), and Gaussian-process-based adaptive sampling (gpCAM) into a unified framework for autonomous scattering experiments. The same configuration operates across two synchrotron beamlines (ALS 7.3.3 and PETRA III P03) with only minimal facility-specific adjustments, as shown in proof-of-concept demonstrations. This validates that a consistent design emphasizing modularity and shared interfaces can ease deployment across diverse experimental environments. The resulting framework provides a flexible foundation for extending autonomous control and analysis capabilities beyond a single beamline or instrument.

47 OTHER INSTRUMENTATION↗

The SEMA3F-NRP1/NRP2 axis is a key factor in the acquisition of invasive traits in in situ breast ductal carcinoma

A better understanding of ductal carcinoma in situ (DCIS) is urgently needed to identify these preinvasive lesions as distinct clinical entities. Semaphorin 3F (SEMA3F) is a soluble axonal guidance molecule, and its coreceptors Neuropilin 1 (NRP1) and NRP2 are strongly expressed in invasive epithelial BC cells. We utilized two cell line models to represent the progression from a healthy state to the mild-aggressive or ductal carcinoma in situ (DCIS) stage and, ultimately, to invasive cell lines. Additionally, we employed in vivo models and conducted analyses on patient databases to ensure the translational relevance of our results. We revealed SEMA3F as a promoter of invasion during the DCIS-to-invasive ductal carcinoma transition in breast cancer (BC) through the action of NRP1 and NRP2. In epithelial cells, SEMA3F activates epithelialmesenchymal transition, whereas it promotes extracellular matrix degradation and basal membrane and myoepithelial cell layer breakdown. Together with our patient database data, these proof-of-concept results reveal new SEMA3F-mediated mechanisms occurring in the most common preinvasive BC lesion, DCIS, and represent potent and direct activation of its transition to invasion. Moreover, and of clinical and therapeutic relevance, the effects of SEMA3F can be blocked directly through its coreceptors, thus preventing invasion and keeping DCIS lesions in the preinvasive state.

60 APPLIED LIFE SCIENCES↗

Chatbots can guide experimentalists to avoid many common mistakes in measuring fluorescence spectra

The concepts of fluorescence spectroscopy are well established, yet the experimental collection of a spectrum is susceptible to a range of errors. A recent study showed that chatbots – derived from substantial advances in artificial intelligence – can provide practical assistance to the experimentalist during collection of absorption spectra and thereby achieve improved quality. Fluorescence, while the complement of absorption, is prone to a far richer array of experimental errors encompassing environmental factors, instrumental settings, and experimentalist mistakes. Here, 10 chatbots (ChatGPT 5, Gemini 2.5 Pro, Microsoft Copilot, Meta AI Llama 4, Claude Sonnet 4.5, X.ai Grok 4, Perplexity Pro, DeepSeek V3.1, Z.ai GLM-4.6, and KIMI K2) have been evaluated for the suitability in providing quality-improvement advice to the experimentalist during acquisition of fluorescence spectra. Significant opportunities for practical assistance are noted, although intervention by a domain expert is often required. Here, if combined with image recognition and/or signal processing, chatbots embedded in instruments may enable real-time guidance during fluorescence data acquisition.

Artificial intelligence↗

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION↗

An ontology-based knowledge graph for representing interactions involving RNA molecules

The "RNA world" represents a novel frontier for the study of fundamental biological processes and human diseases and is paving the way for the development of new drugs tailored to each patient's biomolecular characteristics. Although scientific data about coding and non-coding RNA molecules are constantly produced and available from public repositories, they are scattered across different databases and a centralized, uniform, and semantically consistent representation of the "RNA world" is still lacking. We propose RNA-KG, a knowledge graph (KG) encompassing biological knowledge about RNAs gathered from more than 60 public databases, integrating functional relationships with genes, proteins, and chemicals and ontologically grounded biomedical concepts. To develop RNA-KG, we first identified, pre-processed, and characterized each data source; next, we built a meta-graph that provides an ontological description of the KG by representing all the bio-molecular entities and medical concepts of interest in this domain, as well as the types of interactions connecting them. Finally, we leveraged an instance-based semantically abstracted knowledge model to specify the ontological alignment according to which RNA-KG was generated. RNA-KG can be downloaded in different formats and also queried by a SPARQL endpoint. A thorough topological analysis of the resulting heterogeneous graph provides further insights into the characteristics of the "RNA world". RNA-KG can be both directly explored and visualized, and/or analyzed by applying computational methods to infer bio-medical knowledge from its heterogeneous nodes and edges. The resource can be easily updated with new experimental data, and specific views of the overall KG can be extracted according to the bio-medical problem to be studied.

59 BASIC BIOLOGICAL SCIENCES↗

The ATLAS trigger system for LHC Run 3 and trigger performance in 2022

The ATLAS trigger system is a crucial component of the ATLAS experiment at the LHC. It is responsible for selecting events in line with the ATLAS physics programme. This paper presents an overview of the changes to the trigger and data acquisition system during the second long shutdown of the LHC, and shows the performance of the trigger system and its components in the proton-proton collisions during the 2022 commissioning period as well as its expected performance in proton-proton and heavy-ion collisions for the remainder of the third LHC data-taking period (2022–2025).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗