Search NASA⌕ Search

SEARCH · Search NASA

Results for “Decontamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Decontamination Technologies, Task 3, Urban Remediation and Response Project

In the aftermath of a Radiological Dispersal Device (RDD, also known as a dirty bomb) it will be necessary to remediate the site including building exteriors and interiors, equipment, pavement, vehicles, personal items etc. Remediation will remove or reduce radioactive contamination from the area using a combination of removing and disposing of many assets (including possible demolition of buildings), decontaminating and returning to service other assets, and fixing in place or leaving in place contamination that is deemed 'acceptable'. The later will require setting acceptable dose standards, which will require negotiation with all involved parties and a balance of risk and cost to benefit. To accomplish the first two, disposal or decontamination, a combination of technologies will be deployed that can be loosely classified as: Decontamination; Equipment removal and size reduction; and Demolition. This report will deal only with the decontamination technologies that will be used to return assets to service or to reduce waste disposal. It will not discuss demolition, size reduction or removal technologies or equipment (e.g., backhoe mounted rams, rock splitter, paving breakers and chipping hammers, etc.). As defined by the DOE (1994), decontamination is removal of radiological contamination from the surfaces of facilities and equipment. Expertise in this field comes primarily from the operation and decommissioning of DOE and commercial nuclear facilities as well as a small amount of ongoing research and development closely related to RDD decontamination. Information related to decontamination of fields, buildings, and public spaces resulting from the Goiania and Chernobyl incidents were also reviewed and provide some meaningful insight into decontamination at major urban areas. In order to proceed with decontamination, the item being processed needs to have an intrinsic value that exceeds the cost of the cleaning and justifies the exposure of any workers during the decontamination process(es). In the case of an entire building, the value may be obvious; it's costly to replace the structure. For a smaller item such as a vehicle or painting, the cost versus benefit of decontamination needs to be evaluated. This will be determined on a case by case basis and again is beyond the scope of this report, although some thoughts on decontamination of unique, personal and high value items are given. But, this is clearly an area that starting discussions and negotiations early on will greatly benefit both the economics and timeliness of the clean up. In addition, high value assets might benefit from pre-event protection such as protective coatings or HEPA filtered rooms to prevent contaminated outside air from entering the room (e.g., an art museum).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lessons Learned from Most Recent Chemical Decontamination for Decommissioning Projects - 19280

In 2017, Westinghouse performed a full system chemical decontamination of Units 1 and 2 of the Bohunice V1 Nuclear Power Plant. Bohunice V1 is a VVER 440 design with six loops. The application was performed two loops at a time, with the reactor core bypassed. The Pressurizer and Pressurizer Relief Tank (Bubble Tank) were decontaminated as well, in a separate application. This was a recovery decontamination that had been attempted by another company prior to Westinghouse. Several modifications to equipment and design of process were required to make the decontamination successful. The project was initiated to perform pre-dismantling chemical decontamination of primary circuits of both V1 units using Decontamination for Decommissioning (DfD) to meet the following objectives (see References 1 and 2 for process descriptions of DfD): - Remove activity from the primary circuit components; - Reduce dose rates around piping and components; - Simplify access to the installations, making it possible to use hands-on techniques for dismantling, rather than the more expensive use of robotics or manipulators; - Minimize the potential for spreading contamination during decommissioning activities - Reduce the activity of components that they may be disposed of at a lower classification, therefore more economical, waste disposal category. Several techniques were employed that were unique, or first of a kind, to aid in the decontamination, including resin regeneration and bypass of the reactor core, while still providing enough flow to to allow sufficient dispersal through all the steam generator tubes. Equipment that was already available on site was evaluated and, when possible, combined with Westinghouse equipment to minimize application cost and schedule. The lessons learned from the first unit (Unit 2) were applied to the second unit (Unit 1) application. The partial relocation of equipment allowed for the most efficient schedule to complete the second decontamination. The paper will describe in more detail the results and lessons learned from the full system chemical decontaminations performed, as well as updates on another recent decontamination project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Chemical Decontamination Technology by the IF7 Gas

When we decommission the equipments contaminated by the uranium, both the dismantling process of the equipments and the disposal process of the radioactive waste will be carried out. However, costs of these processes will be very expensive because the dismantling facilities are required in the dismantling process and many radioactive wastes are generated. Here, if it is possible to decontaminate the equipments below the clearance level, the amount of radioactive wastes is reduced very much. As a result, costs of the disposal will be able to reduce extremely. Moreover, if it is possible to decontaminate the equipments before dismantling, costs of the dismantling will be reduced, too. In other words, the total costs of the dismantling process and the disposal process will be minimized by decontaminating below the clearance level without dismantling. So, we have developed new decontamination technology to decontaminate below the clearance level without dismantling. In this paper, as an example, we tried to decontaminate the uranium enrichment plant in order to reveal the practicality of our technology. In conclusion: we proposed new decontamination technology by the IF7 gas. And, as an example, we tried to decontaminate the uranium enrichment plant. As a result, we could reveal that our technology has the high performance which can decontaminate below the assumed clearance level: 1.0 Bq/g in the limited time. Finally, we simulated the amount of the radioactive waste for decommissioning the uranium enrichment plant. As a result, though a lot of radioactive wastes will usually be generated, we obtained the prospect that it is possible to reduced 85% of the radioactive waste by using our technology.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Evaluation of Chemical Decontamination for Contaminated Carbon Steel Scrap by Multiphase Treatment Process - 20249

There is a significant growth in the field of decommissioning of nuclear facilities due the fact that for a lot of them their end of life is nearing. In Taiwan, the government plans to steadily reduce the dependence on nuclear power and moves gradually towards a nuclear-free homeland. Therefore, the development of decommissioning technology becomes the significant issue for the next coming years. The decommissioning of a nuclear power plant is a long process and practical work including radiological surveys, decontamination, dismantling, and the subsequent waste management. Chemical decontamination is an important task in the decommissioning of nuclear power plants and is usually performed by circulating the chemical solution in selected systems or full systems in order to reduce dose levels. However, the decontamination of segmented metal parts is also considered to reduce the contamination to such levels that they may be disposed of at a lower classification or be unconditionally released, and it helps to achieve the goal of waste minimization and provide a more economical cost for disposal management. Chemical decontamination technology is used to remove the contaminated oxides deposited on the surface of metals by dissolving them with chemical mechanisms, such as chelation, acidic or alkaline dissolution, redox reaction and so on. Carbon steel is the major material used in systems and pipelines in the nuclear power plant, thus it is also commonly selected as the target to be decontaminated in the decommissioning process. In this study, the effectiveness of chemical decontamination is evaluated by using multiphase treatment process including the reduction and the oxidation steps. In the step of redox reaction, the oxidation state of the substance is very important. Especially metals of some oxidation states show solubility in water, which has a decisive influence on the chemical decontamination. The experiment of decontamination of metal scraps is carried out by the immersion method within a chemical solution. The relative operation parameters such as temperature, pH, and concentration of the chemical solution are recorded to demonstrate the effect of the decontamination process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decontamination and Management of Human Remains Following Incidents of Hazardous Chemical Release

Abstract Objective: To provide specific procedural guidance and resources for identification, assessment, control, and mitigation of compounds that may contaminate human remains resulting from chemical attack or release. Design: A detailed technical, policy, and regulatory review is summarized. Setting: Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present. Settings would include sites of transportation accidents, natural disasters, terrorist or military operations, mortuary affairs or medical examiner processing and decontamination points, and similar. Patients, Participants: While recommended procedures have not been validated with actual human remains, guidance has been developed from data characterizing controlled experiments with fabrics, materiel, and laboratory animals. Main Outcome Measure(s): Presentation of logic and specific procedures for remains management, protection and decontamination of mortuary affairs personnel, as well as decision criteria for determining when remains are sufficiently decontaminated so as to pose no chemical health hazard. Results: Established procedures and existing equipment/materiel available for decontamination and verification provide appropriate and reasonable means to mitigate chemical hazards from remains. Extensive characterization of issues related to remains decontamination indicates that supra-lethal concentrations of liquid chemical warfare agent VX may prove difficult to decontaminate and verify in a timely fashion. Specialized personnel can and should be called upon to assist with monitoring necessary to clear decontaminated remains for transport and processing. Conclusions: Once appropriate decontamination and verification have been accomplished, normal procedures for remains processing and transport to the decedent s family and the continental United States can be followed.

99 GENERAL AND MISCELLANEOUS↗

Demonstration of Wide Area Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles - 16508

Researchers at the U.S. Environmental Protection Agency in collaboration with the Department of Homeland Security conducted the 'Wide-Area Urban Radiological Contaminant, Mitigation, and Clean-Up Technology Demonstration' in Columbus, Ohio on June 22-25, 2015. EPA's National Homeland Security Research Center (NHSRC) demonstrated five wide-area radiological decontamination technologies (including strippable coatings, gels, and chemical foam technologies) on an urban building. Decontamination technologies were applied to remove the contaminants from the building's surfaces by physical, chemical, or other methods, which in practice could reduce radiation exposure level. In addition, NHSRC teamed with the Department of Homeland Security (DHS) to demonstrate several radiological contaminant mitigation technologies including building and vehicle wash technologies, as well as several approaches to contain wash water and radioactive particles. 'Radiological contaminant mitigation' technologies are measures taken to reduce adverse impacts of radiological contamination on people and the environment, and facilitate such purposes as restoration of first responder services and critical infrastructure. Radiological contaminant mitigation technologies are designed for containing and removing radiological contamination on the surface in the first hours or days following a radiological event (early phase response). Such technologies include 'radiological particle containment', which is design to prevent the spread of particles which might result from vehicle or foot traffic. Radiological particle containment technologies are applicable for early phase response to contain the radionuclides and to reduce radiation dose to responders and the public. Mitigation also includes 'gross decontamination' technologies, which perform a type of decontamination that is conducted with the goal of reducing contamination levels. This reduction may not meet final cleanup levels, but may be useful to mitigate some public hazard or contain contamination. The purpose of the demonstrations was to educate potential end-users and stakeholders of this technology about a 'Toolbox of Options' for radiological decontamination, as well as radiological contaminant mitigation. Both demonstrations were conducted using a 75-year old brick building and the surrounding area (including parking lots) in Columbus, OH. No radioactive contaminants were applied during either demonstration, as the objective was to duplicate and implement realistic operational conditions for these technologies. Surrogate contaminants such as particle tracers were used in several demonstrations. The decontamination technologies were used in a scaled-up setting with application to the building. Contaminant mitigation technologies were demonstrated on the building as well as on vehicles. Example technology application techniques/accessories included an articulating boom lift, repelling boatswain chair, stand-alone surface material structures, high-volume foam applicators, fire truck foam applicator, a vehicle wash tent for vehicles, particle tracers to simulate radiological contaminants, and high- and low-technology liquid containment approaches. Results and stakeholder observations from the demonstration are now publically in a report entitled 'Technical Report for the Demonstration of Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles' available at http://www.epa.gov/hsresearch Example information that was obtained included decontamination rate, contaminant mitigation and containment capacity, user friendliness of each technology, the required utilities (electric, water, etc.) for each technology, skill of worker required, and the cost. The condition (color, texture, integrity, etc.) of each building material present on the structure along with all structural components such as gutters, windows, doors, etc. were carefully examined and documented. All demonstrations were open to individuals, organizations, and local, state, federal, tribal, and international governments who may be involved with implementing or planning radiological incident response. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decontamination Experiments and Simulations Supporting Recovery After Widespread Contamination - 18685

Clean-up after an uncontrolled nuclear material release differs from common decontamination practices in the nuclear industry and military combat scenarios. Uncontrolled releases, particularly acts of terror, require specific protective actions guides (PAGs) to optimize short and long-term repercussions. Ideally, non-destructive decontamination methods would be employed. To help fulfill this need, the IWATERS (Integrated Wash Aid Treatment Emergency Reuse System) was proposed in 2014 for remediation outside the immediate blast area. 'Wash-Aid' is hosed onto affected areas, and the used wash solution is collected and recycled through sand/clay beds. To help characterize the IWATERS technology, the below was completed: - Decontamination experiments with a pressurized wash solution using Cs-137, Sr- 85, and Eu-152 contaminants on porous urban materials. - Sensitivity analyses on recycling bed variables using GoldSim{sup TM} CT. - A proposed framework that expands the recycling bed model to include probabilistic simulation of immediate recovery efforts. Removal efficacy of tap water and 0.5 M KCl were compared for Cs, Sr, and Eu across asphalt, brick, and concrete. The 0.5 M KCl solution significantly outperformed tap water in every case except for Eu on concrete and Cs on brick. Trends in the high-pressure decontamination with salt additive compared to low pressure decontamination show evidence of physical and chemical removal. Variations in cleaning rate yielded no significant trend. Pressure changes (by adjusting nozzle-to-coupon distance) were only significant for the highest pressure. Hypothetical Contamination Scenario: To tie the decontamination experiments and recycling bed model together, a small contamination scenario was created. Imagine the sides of a small concrete building uniformly contaminated with Cs-137. Power washing the building with 0.5 M KCl solution would result in 857 L of contaminated solution generated in 185 minutes. Two sand clay beds were designed to clean the used solution. With a sand mass fraction of 0.9, a 10 ft{sup 2} bed 4 ft tall could recycle the solution in 1.05 hrs. Changing the sand mass fraction to 0.5 yielded a 2.5 ft{sup 2} bed 4 ft tall (∼55-gallon drum) that recycled the solution in 7.43 hrs. This exercise showed how the sand/clay bed design can easily change to match the primary remediation goals. The second sand/clay bed would reduce the waste generation while the first bed reduces the remediation time. Conclusions: Variations on speed and nozzle distance (pressure) yielded insignificant differences in efficacy except for the closest distance. High-pressure washing showed increased decontamination efficacy with KCl additive in the majority of cases. Except for bed composition, key recycling bed parameters can be varied on-the-fly. This allows for optimization of, for example, time and waste generation. The hypothetical contamination scenario showed pairing decontamination experiment results with modeling tools can lead to increased preparedness for a large-scale contamination event. With collaboration and time, an expanded recovery/remediation model could aid in development of effective protective action guides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effects of Contaminant-Aging on Decontamination Efficacy for Rapid Remediation of Concrete Surfaces - 20412

Understanding the relationship between decontamination efficacy and contaminant aging is imperative for developing effective remediation strategies following a large-scale contamination event. Non-destructive decontamination of concrete following a contamination incident becomes more difficult with increased time between contamination and decontamination because contaminants may chemically bind to concrete and/or penetrate into the concrete subsurface. In this work, we evaluated the decontamination efficacy of two decontamination methods on concrete samples contaminated with soluble Cesium-137 (Cs-137) and silica particles with 0.5 μm and 2 μm diameters. Concrete samples were aged between 1 and 59 days, with half of the coupons receiving 1 mL of artificial rainwater about once every three days. After aging, coupons were either decontaminated or analyzed to determine contaminant penetration depths. Coupons were decontaminated with 0.1 M Potassium Chloride (KCI) solution applied either by flowing solution across the contaminated coupon face or non-destructive power washing. Contaminant depth profiles were created by removing the top surface of the coupon at least 15 times, measuring the activity in each removed layer, normalizing the total activity removed to the measured decontamination efficacy following the last layer removal, and determining the penetration thickness using the coupon dimensions, bulk density, and mass of material removed for each layer. Pressurized washing effectively removed particles, but not soluble cesium, despite the majority of Cs-137 being located within the first millimeter of the subsurface. Soluble cesium removal by flowing 0.1 M KCI solution across the contaminated surface dropped to less than 12% within the first ten days. This drop in Cs-137 removal efficacy occurred within the first five days for coupons experiencing artificial rainfall events. Flowing 0.1 M KCI solution across the contaminated face was ineffective at removing particles, likely because particles had localized in surface depressions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of Passive Phoretic Decontamination by Accident Simulation in a Scaled Reactor Containment

Reactor containment performance is a critical defense-in- depth barrier for the prevention of radioactive release in the event of a nuclear accident. One of the functions of the containment is to assist in the decontamination of aerosolized radioactive particles through both 'passive' or natural processes and 'active' or mechanical processes. Current United States Nuclear Regulatory Commission (NRC) guidance (Reg. guide 1.183) allows the use of aerosol natural deposition correlations to quantify postaccident nuclear containment decontamination factors. Large Light Water Reactor (LLWR) correlations have previously been developed to quantify the contribution of natural phenomena to post-accident aerosol decontamination. Specific correlations must similarly be developed to support the safety analyses of Small Modular Reactors (SMRs). For LLWR plants, decontamination is achieved 'actively' by mechanical systems such as containment sprays and 'passively' via natural phenomena such as gravitational settling, condensation, impaction, thermophoresis, diffusiophoresis and hygroscopic effects. Integrated pressurized water reactor (iPWR) SMR designs do not have containment sprays; therefore, they rely primarily on passive natural phenomena for decontamination in the integrated reactor vessel. Analytical studies and inferences from LLWR test data suggest that the smaller containment vessel volume to surface area ratio, coupled with the thermal hydraulic properties of iPWR plants, would significantly enhance decontamination factors for these smaller designs. The research aims to quantify the amount of decontamination from natural phenomena for the range of iPWR physical and thermal hydraulic characteristics. A preliminary assessment has shown that diffusiophoresis, thermophoresis and hygroscopic effects are the major areas with a research gap for iPWR plants; hence these areas are the foci of the research. These first-of-a-kind experiments will be described and preliminary analytical results will be presented that show the expected effects of SMR-specific correlations on passive decontamination of aerosolized radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Laboratory Scoping Tests Of Decontamination Of Hanford Waste Treatment Plant Low Activity Waste Off-Gas Condensate Simulant

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of glass waste. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task seeks to examine the potential treatment of this stream to remove radionuclides and subsequently disposition the decontaminated stream elsewhere, such as the Effluent Treatment Facility (ETF), for example. The treatment process envisioned is very similar to that used for the Actinide Removal Process (ARP) that has been operating for years at the Savannah River Site (SRS), and focuses on using mature radionuclide removal technologies that are also compatible with longterm tank storage and immobilization methods. For this new application, testing is needed to demonstrate acceptable treatment sorbents and precipitating agents and measure decontamination factors for additional radionuclides in this unique waste stream. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet and will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. One of the radionuclides that is volatile and expected to be in high concentration in this LAW Off-Gas Condensate stream is Technetium-99 ( 99 Tc). Technetium will not be removed from the aqueous waste in the Hanford WTP, and will primarily end up immobilized in the LAW glass by repeated recycle of the off-gas condensate into the LAW melter. Other radionuclides that are also expected to be in appreciable concentration in the LAW Off-Gas Condensate are 129 I, 90 Sr, 137 Cs, and {sup 241}Am. This report discusses results of preliminary radionuclide decontamination testing of the simulant. Testing examined use of Monosodium Titanate (MST) to remove 90 Sr and actinides, inorganic reducing agents for 99 Tc, and zeolites for 137 Cs. Test results indicate that excellent removal of 99 Tc was achieved using Sn(II)Cl 2 as a reductant, coupled with sorption onto hydroxyapatite, even in the presence of air and at room temperature. This process was very effective at neutral pH, with a Decontamination Factor (DF) >577 in two hours. It was less effective at alkaline pH. Conversely, removal of the cesium was more effective at alkaline pH, with a DF of 17.9. As anticipated, ammonium ion probably interfered with the Ionsiv®a IE-95 zeolite uptake of 137 Cs. Although this DF of 137 Cs was moderate, additional testing is expected to identify more effective conditions. Similarly, Monosodium Titanate (MST) was more effective at alkaline pH at removing Sr, Pu, and U, with a DF of 319, 11.6, and 10.5, respectively, within 24 hours. Actually, the Ionsiv® IE-95, which was targeting removal of Cs, was also moderately effective for Sr, and highly effective for Pu and U at alkaline pH. The only deleterious effect observed was that the chromium co-precipitates with the {sup 99}Tc during the SnCl 2 reduction. This effect was anticipated, and would have to be considered when managing disposition paths of this stream. Results of this separation testing indicate that sorption/precipitation was a viable concept and has the potential to decontaminate the stream. All radionuclides were at least partially removed by one or more of the materials tested. Based on the results, a possible treatment scenario could involve the use of a reductive precipitation agent (SnCl 2 ) and sorbent at neutral pH to remove the Tc, followed by pH adjustment and the addition of zeolite (Ionsiv® IE-95) to remove the Cs, Sr, and actinides. Addition of MST to remove Sr and actinides may not be needed. Since this was an initial phase of testing, additional tasks to improve separation methods were expected to be identified. Primarily, further testing is needed to identify the conditions for the decontamination process. Once these conditions are established, follow-on tasks likely include evaluation and testing of applicable solid-liquid separation technologies, slurry rheology measurements, composition variability testing and evaluations, corrosion and erosion testing, slurry storage and immobilization investigations, and decontaminated LAW Off-Gas Condensate evaporation and solidification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced chemical CRUD decontamination combined with electrokinetic process - 15242

This study has tested about the deposition and dissolution of Chalk River Unidentified Deposit (CRUD), and investigated the remediation of CRUD. CRUD is an accumulated corrosion product on external fuel rod cladding surfaces and composed of either dissolved ions or solid particles such as Ni and Co. As nuclear power plants are getting older, decontaminating process has been concerned due to increased contamination. Corrosion product can be activated through nuclear reaction to form radionuclide such as Co-60. Because the CRUD is formed at cladding surface and radionuclides can be contained in CRUD, it can affect to human health and environment. Therefore CRUD needs to be removed safely during NPP's decontaminating process by efficient. In order to decontaminate the CRUD, first thing it has to be dissolved and removed. Deposition behavior of corrosion products has been well studied, but the study about behavior of CRUD dissolution is required in various environments. In this study, the CRUD synthesis, the dissolution method of CRUD, and the CRUD decontamination method was investigated. There are three major approaches the remediation of CRUD. First one is well synthesized the CRUD, second one is finding the optimum condition for CRUD dissolution, and last one is applying the Electro-Kinetic (EK) process to CRUD remediation. Synthesis of simulated CRUD for the decontamination experiments was successful. The combination of EK process with chemical decontamination of CRUD proved to be a more economical method for removing CRUD; it can be directly applied to the NPP decommissioning and decontamination process, and it can decrease the volume of secondary radioactive waste as well. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Remote Laser Decontamination System - 18183

A cleaning method using a laser ablation technology is widely used in various industries such as automobile, aviation, and semiconductor industries. Recently, applying this technology to decontamination works has been receiving attention as a useful and effective decontamination method. The laser decontamination method allows for decreasing a generation of secondary radioactive waste because materials like abrasive and water are not required. This is one of big advantages in use for decontamination works. Additionally, the system is compact and requires less than 100 W electric power. These features provide a low running cost. Remote operation obviously plays an important role in terms of a dose reduction in highly-radioactive and contaminated environment. The laser decontamination method is also suitable for remote works using manipulators as the laser head is light and compact, and a reaction force during operation is small, compared to the other types of decontamination tools. This paper provides an outline and a capability of the remote laser decontamination system developed by IHI Corporation (IHI) with some results of component tests for this system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Techniques for Concrete Decontamination During Decommissioning - 19005

As the primary material of construction for nuclear power plant structures, concrete naturally represents the largest fraction of contaminated material by surface area. As such, decontamination of concrete is a major activity during decommissioning projects. As reported in EPRI 3002005412, Characterization and Remediation of Contaminated Concrete, currently used techniques for decontamination of contaminated concrete are generally slow and labor-intensive to apply. This report notes that little change to the techniques used for concrete decontamination have been made during the past 20 years. There is a clear need for improvement to the techniques available for decontamination of concrete. Needed enhancements include substantial improvements in efficiency, waste management, industrial safety, and worker radiation exposure. Potential areas for development include increased automation of existing techniques, improvement in delivery systems for decontamination equipment, and further development of alternative techniques such as microwave and laser scabbling, and nitrogen blasting. To address this need, EPRI is conducting a project to develop enhanced techniques for concrete decontamination. The project focuses on two primary areas: 1. Adaption of existing techniques to improve efficiency through automation and/or altering the delivery systems for the decontamination equipment (for example, through use of exiting robotic systems); and 2. Field demonstration of technologies currently in the engineering development stage, such as nitrogen blasting and laser scabbling. This paper will report the initial results of this EPRI project, which includes identification of promising candidate technologies that will be demonstrated during the next project phase. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DECONTAMINATION OF ZIRCALOY CLADDING HULLS FROM SPENT NUCLEAR FUEL

The feasibility of decontaminating spent fuel cladding hulls using hydrofluoric acid (HF) was investigated as part of the Global Energy Nuclear Partnership (GNEP) Separations Campaign. The concentrations of the fission product and transuranic (TRU) isotopes in the decontaminated hulls were compared to the limits for determining the low level waste (LLW) classification in the United States (US). The {sup 90}Sr and {sup 137}Cs concentrations met the disposal criteria for a Class C LLW; although, in a number of experiments the criteria for disposal as a Class B LLW were met. The TRU concentration in the hulls generally exceeded the Class C LLW limit by at least an order of magnitude. The concentration decreased sharply as the initial 30-40 {micro}m of the cladding hull surface were removed. At depths beyond this point, the TRU activity remained relatively constant, well above the Class C limit. Reprocessing of spent nuclear fuel generates a cladding waste which would likely require disposal as a Greater than Class C LLW in the US. If the cladding hulls could be treated to remove a majority of the actinide and fission product contamination, the hulls could potentially meet acceptance criteria for disposal as a LLW or allow recycle of the Zr metal. Discard of the hulls as a LLW would result in significant cost savings compared to disposal as a Greater than Class C waste which currently has no disposition path. During fuel irradiation and reprocessing, radioactive materials are produced and deposited in the Zircaloy cladding. Due to short depths of penetration, the majority of the fission products and actinide elements are located in the ZrO{sub 2} layer which forms on the surface of the cladding during fuel irradiation. Therefore, if the oxide layer is removed, the majority of the contamination should also be removed. It is very difficult, if not impossible to remove all of the activity from spent fuel cladding since traces of U and Th in the unirradiated Zircaloy adsorb neutrons generating higher actinides in the bulk material. During fuel irradiation, {sup 92}Zr is also converted to radioactive {sup 93}Zr by neutron adsorption. Methods for decontaminating and conditioning irradiated Zircaloy cladding hulls have been investigated in Europe, Japan, and the US during the last 35 years; however, a method to decontaminate the hulls to an activity level which meets US acceptance criteria for disposal as a LLW was not deployed on a commercial scale. The feasibility of decontaminating spent fuel cladding hulls was investigated as part of the GNEP Separations Campaign. Small-scale experiments were used to demonstrate the removal of the ZrO{sub 2} layer from Zircaloy coupons using dilute solutions ({le}1.0 M) of HF. The most effective conditions resulted in dissolution rates which were less than approximately 2 mg/cm{sup 2}-min. With dissolution rates in this range, uniform removal of the oxide layer was obtained and a minimal amount of Zircaloy metal was dissolved. To test the HF decontamination process, experiments were subsequently performed using actual spent fuel cladding hulls. Decontamination experiments were performed to measure the fission product and actinide concentrations as a function of the depth of the surface removed from the cladding hull. The experimental methods used to perform these experiments and a discussion of the results and observations are presented in the following sections.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Developing Surrogate Far-Field Nuclear Fallout and its Rapid Decontamination from Aircraft Surfaces

Naval aircraft and vehicles deployed in response to the tsunami of 2011 and subsequent nuclear meltdown at the Fukushima Daiichi nuclear power station were exposed to and contaminated with radioactive materials released to the atmosphere. In response, the Navy and Argonne National Laboratory are testing various decontamination methods to clean aircraft surfaces exposed to far-field nuclear fallout. Far-field fallout, which can travel hundreds of miles, includes dissolved radionuclides and fine particulate matter. To simulate contamination with such materials, dissolved cesium-137 ( 137 Cs) and radiolabeled particles were deposited on coupons (1 x 1 in. sections) of tire, acrylic, and painted metal surfaces. These coupons were subjected to six different decontamination methods, including ones involving four strippable products, a soap solution, and tap water. Removals of dissolved 137 Cs were generally high: over 90% of the deposited radionuclide was removed after three decontaminations. To simulate exposure to inert, radioactive fallout or other inert, airborne particulate, silica (SiO 2 ) particles were used as surrogate fine particulate matter. The silica particles were radio-labeled by first depositing europium-152 ( 152 Eu) or americium-241 ( 241 Am) on the particle surface as sesquioxides (Eu 2 O 3 or Am 2 O 3 ), then coating it with sodium silicate. Scanning electron microscopy confirmed that particle size was not altered by the treatment, while leaching studies into numerous solutions and decontamination agents confirmed that minimal amounts of the radiolabel dissolved into solution. Three different methods to apply the radioactive particles to the silica were evaluated. Pressing the coupons into a dish containing the particles resulted in particle clumping on the surface, while applying the particles within water also resulted in heterogeneous surface coverage. Suspending the particles in ethanol and then applying them to the surface supplied homogeneous surface coverage that provided acute and precise removal percentages. Finally, particle-surface interactions seemingly play an important role in radiological decontamination as the removal percentages were lower than those of soluble 137 Cs for aqueous decontamination methods. These decreased removal percentages indicate that more complex methods such as strippable decontamination agents are required to remove particulate far-field fallout from aircraft and similar vehicle surfaces.

36 MATERIALS SCIENCE↗

Trimming and Decontamination of Metagenomic Data can Significantly Impact Assembly and Binning Metrics, Phylogenomic and Functional Analysis

Background: Investigators using metagenomic sequencing to study microbiomes often trim and decontaminate reads without knowing their effect on downstream analyses. Objective: This study was designed to evaluate the impacts JGI trimming and decontamination procedures have on assembly and binning metrics, placement of MAGs into species trees, and functional profiles of MAGs extracted from complex rhizosphere metagenomes, as well as how more aggressive trimming impacts these binning metrics. Methods: Twenty-three Miscanthus x giganteus rhizosphere metagenomes were subjected to different combinations and thresholds of force, kmer, and quality trimming and decontamination using BBDuk. Reads were assembled and binned in KBase. Phylogenomic and statistical analyses were applied to evaluate the effects of trimming and decontamination on downstream analyses. Results: We found that JGI trimmed and decontaminated reads had significant impacts on assembly and binning metrics compared to raw reads, including significantly higher total contig counts, more contigs greater than 10k bp in length, and larger total lengths of raw assemblies compared to QC assemblies, and 2.0% lower average contamination of QC MAGs compared to raw MAGs. We also found that differences in the placement of MAGs in species trees increased with decreasing completeness and contamination thresholds. Furthermore, aggressive trimming (Q20) was found to significantly reduce MAG counts. Conclusion: Trimming and decontamination of metagenomics reads prior to assembly can change an investigator’s answer to the questions, “Who is there and what are they doing?” However, mild trimming and decontamination of metagenomic reads with high-quality scores are recommended for removing sample processing and sequencing artifacts.

Whitham, Jason M.↗

Distribution of radioactive Cesium in trees and effect of decontamination of forest contaminated by the Fukushima nuclear accident

In decontamination pilot projects conducted by Japan Atomic Energy Agency (JAEA), many different techniques were tested to determine their applicability to remediate areas evacuated after the Fukushima Daiichi nuclear accident following the Great Tohoku earthquake and tsunami of March 11, 2011. In addition to buildings, roads and farmland, the forest adjacent to living areas was one of the main decontamination targets. The projects evaluated the radioactive contamination of trees and the effectiveness of decontaminating a highly contaminated evergreen forest. This forest was located 1.3 km southwest of the Fukushima Daiichi Nuclear Power Plant and is dominated by Japanese cedar trees and fir trees. As the first step, three Japanese cedar trees and three fir trees were cut down and the distributions of radioactive cesium (Cs) were measured in each. The total concentrations of {sup 134}Cs and {sup 137}Cs in the leaves and branches were about 1 MBq/kg for both cedar and fir trees, and were appreciably higher than in the bark for cedar. The concentrations in the outer part of the trunks (under the bark) were lower, on the order of 10 kBq/kg, and those in the core of the trunks were lower than 1 kBq/kg for both kinds of trees. The observation that the Cs concentrations are higher in the outer part of trees, is compatible with the assumption that radio-Cs was mostly adsorbed on the surface of trees and partly penetrated into the trunks through the bark. Evolution of air dose rates in a 100 x 60 m pasture adjacent to the forest was monitored during decontamination of the forest and of the pasture itself. The dose rates in the pasture decreased drastically after stripping contaminated topsoil from the pasture and decreased slightly more after stripping contaminated topsoil of the forest floor and pruning the trees. Cutting down and removing 84 trees in the outermost area (10- m width) of the forest also slightly decreased these dose rates. After decontamination, the residual dose rates around the highly contaminated forest were mostly attributed to radioactive Cs existing in or on trees and topsoil in the untouched forest beyond the decontaminated area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗