Search NASA⌕ Search

SEARCH · Search NASA

Results for “Densitometry, X-Ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of calcium and phosphorus excretion with bone density changes during restraint in immature Macaca nemestrina primates.

Calcium and phosphorus balance data on Macaca nemestrina monkeys during immobilization are presented and correlated with X-ray bone densitometry findings. A positive mineral balance was maintained during the immobilized period. A reduced bone density was observed in most skeletal sites examined with increased density observed in epiphyseal regions. Migration of mineral from one site to another is suggested as a possible explanation for the findings.

Hoffman, R. A.↗

Biomedical technology transfer. Applications of NASA science and technology

Ongoing projects described address: (1) intracranial pressure monitoring; (2) versatile portable speech prosthesis; (3) cardiovascular magnetic measurements; (4) improved EMG biotelemetry for pediatrics; (5) ultrasonic kidney stone disintegration; (6) pediatric roentgen densitometry; (7) X-ray spatial frequency multiplexing; (8) mechanical impedance determination of bone strength; (9) visual-to-tactile mobility aid for the blind; (10) Purkinje image eyetracker and stabilized photocoalqulator; (11) neurological applications of NASA-SRI eyetracker; (12) ICU synthesized speech alarm; (13) NANOPHOR: microelectrophoresis instrument; (14) WRISTCOM: tactile communication system for the deaf-blind; (15) medical applications of NASA liquid-circulating garments; and (16) hip prosthesis with biotelemetry. Potential transfer projects include a person-portable versatile speech prosthesis, a critical care transport sytem, a clinical information system for cardiology, a programmable biofeedback orthosis for scoliosis a pediatric long-bone reconstruction, and spinal immobilization apparatus.

Harrison, D. C.↗

Chemical Processing and Analysis of 'JACEE' Circumpolar Flight 13 & 14

This informal presentation will address the chemical processing status, the current locations and state of data analysis (including mapping and densitometry of x-ray films, event lists and tracing of events in nuclear emulsions, etc.) of the 12 cosmic ray chambers comprising the JACEE-13 and JACEE-14 South Pole circumnavigational long duration balloon flights.

Fountain, Walter↗

Advances in space technology: the NSBRI Technology Development Team

As evidenced from Mir and other long-duration space missions, the space environment can cause significant alterations in the human physiology that could prove dangerous for astronauts. The NASA programme to develop countermeasures for these deleterious human health effects is being carried out by the National Space Biomedical Research Institute (NSBRI). The NSBRI has 12 research teams, ten of which are primarily physiology based, one addresses on-board medical care, and the twelfth focuses on technology development in support of the other research teams. This Technology Development (TD) Team initially supported four instrumentation developments: (1) an advanced, multiple projection, dual energy X ray absorptiometry (AMPDXA) scanning system: (2) a portable neutron spectrometer; (3) a miniature time-of-flight mass spectrometer: and (4) a cardiovascular identification system. Technical highlights of the original projects are presented along with an introduction to the five new TD Team projects being funded by the NSBRI.

Non-NASA Center↗

High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

NASA Discipline Number 26-10↗

Fabrication of Ta-Reinforced Cu-Based Bulk Metallic Glass Composites by High-Pressure Torsion

Ex situ Cu{sub 54}Zr{sub 22}Ti{sub 18}Ni{sub 6} matrix bulk metallic glass composites (BMGCs) reinforced with Ta particles (10–30 vol.%) were fabricated by high-pressure torsion (HPT) under applied pressure of 6 GPa for 1–3 turns at temperatures of 25 or 200 °C. The densification, structure, thermal, and mechanical properties of BMGC samples were investigated by Archimedes densitometry, optical microscopy, x-ray diffraction, differential scanning calorimetry, small punch test, and microhardness measurements. Near full-density BMGC disks (relative densities higher than 0.97) are fabricated using HPT, irrespective of the processing strain and temperature. The microhardness of BMGCs is improved by increasing the number of turns, or the processing temperature due to the improvement in the deformation degree of both the amorphous and Ta particles as well as the reduction in the interlayer spacing of Ta particles. Nevertheless, there is an optimal amount of Ta which gives rise to the peak hardness in the BMGC samples, depending on the amount of imposed strain during HPT. The results of small punch test indicate that the addition of Ta to the monolithic BMG and increasing the HPT temperature significantly enhance the fracture load and deflection.

36 MATERIALS SCIENCE↗

Performance evaluation of the ORNL multi-elemental XRF analysis algorithms

Hybrid K-Edge Densitometer (HKED) systems integrate both K-Edge Densitometry (KED) and X-Ray Fluorescence (XRF) analyses to provide accurate rapid, assay results of the uranium and plutonium content of dissolver solution samples from nuclear fuel reprocessing facilities. Introduced for international safeguards applications in the late 1980s, the XRF component of the hybrid analyses is limited to quantification of U and Pu over a narrow range of U:Pu concentration ratios in the vicinity of ≈100. The analysis was further limited regarding the presence of minor actinide components where only a single minor actinide (typically Am) is included in the analysis and then only treated as an interference. The evolving nuclear fuel cycle has created the need to assay more complex dissolver solutions where uranium may no longer be the dominant actinide in the solution and the concentrations of the so called minor actinides (e.g., Th, Np, Am, and Cm) are sufficiently high that they can no longer be treated as impurities and ignored. Extension of the traditional HKED Region of Interest (ROI) based analysis to include these additional actinides is not possible due to the increased complexity of the XRF spectra. Oak Ridge National Laboratory (ORNL) has developed a spectral fitting approach to the HKED XRF measurement with an enhanced algorithm set to accommodate these complex XRF spectra. This report provides a summary of the spectral fitting methodology and examines the performance of these algorithms using data obtained from the ORNL HKED system, as well as data provided by the International Atomic Energy Agency (IAEA) on actual dissolver solutions.

97 MATHEMATICS AND COMPUTING↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Self-Irradiation Correction for the Hybrid K-Edge Densitometer

Hybrid x-ray fluorescence and K-edge densitometry is used at nuclear fuel reprocessing facilities to determine the concentrations of uranium and plutonium in the input accountability vessel. The uranium concentration is determined by K-edge densitometry, that is, from the step-difference in transmission on either side of the K-absorption edge measured using a continuous x-ray spectrum on a vial of the solution defining a well-known geometry. Historically this was done using a basic region of interest analysis but recently to accommodate more challenging solution full spectral analysis has been developed with considerable benefits. In parallel with the transmission measurement, the relative plutonium-to-uranium concentration is obtained from the relative strength of the x-ray–induced K-shell x-ray fluorescence production measured at a backward angle in energy-dispersive mode. However, gamma-ray emissions from fission products present in the solution also cause fluorescence of the characteristic actinide x-rays. Uncorrected, these self-irradiation–induced x-rays can introduce a bias into the reported U:Pu result. The commonly implemented method to correct this interference requires acquisition of a long (~8 hour) passive spectra for the sample. Although effective, it is often impractical to perform a passive measurement on every sample such that a representative passive spectrum is used. We have developed an alternative correction methodology using only the active x-ray fluorescence spectrum that eliminates the requirement for the time-consuming passive count. The active self-interrogation methodology will be discussed and initial performance results presented.

Mcelroy Jr, Robert↗

Cross-sectional structural parameters from densitometry

Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section along the length of the scan. Various aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of cross-sectional properties. Factors considered included X-ray photon energy, initial scan orientation, the angle spanned by the three scans (included angle), and I(min)/I(max) ratios. Principal moments of inertia were accurate to within +/-3.1% and principal angles were within +/-1 degrees of the expected value for phantoms scanned with included angles of 60 degrees and 90 degrees at the higher X-ray photon energy (140 kVp). Low standard deviations in the error (0.68-1.84%) also indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 degrees. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (I(min)/I(max)) values when various included angles are used make this technique viable for future in vivo studies.

NASA Center ARC↗

Assessment of metabolic bone diseases by quantitative computed tomography

Advances in the radiologic sciences have permitted the development of numerous noninvasive techniques for measuring the mineral content of bone, with varying degrees of precision, accuracy, and sensitivity. The techniques of standard radiography, radiogrammetry, photodensitometry, Compton scattering, neutron activation analysis, single and dual photon absorptiometry, and quantitative computed tomography (QCT) are described and reviewed in depth. Results from previous cross-sectional and longitudinal QCT investigations are given. They then describe a current investigation in which they studied 269 subjects, including 173 normal women, 34 patients with hyperparathyroidism, 24 patients with steroid-induced osteoporosis, and 38 men with idiopathic osteoporosis. Spinal quantitative computed tomography, radiogrammetry, and single photon absorptiometry were performed, and a spinal fracture index was calculated on all patients. The authors found a disproportionate loss of spinal trabecular mineral compared to appendicular mineral in the men with idiopathic osteoporosis and the patients with steroid-induced osteoporosis. They observed roughly equivalent mineral loss in both the appendicular and axial regions in the hyperparathyroid patients. The appendicular cortical measurements correlated moderately well with each other but less well with spinal trabecular QCT. The spinal fracture index correlated well with QCT and less well with the appendicular measurements. Knowledge of appendicular cortical mineral status is important in its own right but is not a valid predictor of axial trabecular mineral status, which may be disproportionately decreased in certain diseases. Quantitative CT provides a reliable means of assessing the latter region of the skeleton, correlates well with the spinal fracture index (a semiquantitative measurement of end-organ failure), and offers the clinician a sensitive means of following the effects of therapy.

Minerals/analysis↗

Current methods and advances in bone densitometry

Bone mass is the primary, although not the only, determinant of fracture. Over the past few years a number of noninvasive techniques have been developed to more sensitively quantitate bone mass. These include single and dual photon absorptiometry (SPA and DPA), single and dual X-ray absorptiometry (SXA and DXA) and quantitative computed tomography (QCT). While differing in anatomic sites measured and in their estimates of precision, accuracy, and fracture discrimination, all of these methods provide clinically useful measurements of skeletal status. It is the intent of this review to discuss the pros and cons of these techniques and to present the new applications of ultrasound (US) and magnetic resonance (MRI) in the detection and management of osteoporosis.

Review, Academic↗

Expanding the Description of Spaceflight Effects beyond Bone Mineral Density [BMD]: Trabecular Bone Score [TBS] in ISS Astronauts

Dual-energy x-ray absorptiometry [DXA] is the widely-applied bone densitometry method used to diagnose osteoporosis in a terrestrial population known to be at risk for age-related bone loss. This medical test, which measures areal bone mineral density [aBMD] of clinically-relevant skeletal sites (e.g., hip and spine), helps the clinician to identify which persons, among postmenopausal women and men older than 50 years, are at high risk for low trauma or fragility fractures and might require an intervention. The most recognized osteoporotic fragility fracture is the vertebral compression fracture which can lead to kyphosis or hunched backs typically seen in the elderly. DXA measurement of BMD however is recognized to be insufficient as a sole index for assessing fracture risk. DXA's limitation may be related to its inability to monitor changes in structural parameters, such as trabecular vs. cortical bone volumes, bone geometry or trabecular microarchitecture. Hence, in order to understand risks to human health and performance due to space exposure, NASA needs to expand its measurements of bone to include other contributors to skeletal integrity. To this aim, the Bone and Mineral Lab conducted a pilot study for a novel measurement of bone microarchitecture that can be obtained by retrospective analysis of DXA scans. Trabecular Bone Score (TBS) assesses changes to trabecular microarchitecture by measuring the grey color "texture" information extracted from DXA images of the lumbar spine. An analysis of TBS in 51 ISS astronauts was conducted to assess if TBS could detect 1) an effect of spaceflight and 2) a response to countermeasures independent of DXA BMD. In addition, changes in trunk body lean tissue mass and in trunk body fat tissue mass were also evaluated to explore an association between body composition, as impacted by ARED exercise, and bone microarchitecture. The pilot analysis of 51 astronaut scans of the lumbar spine suggests that, following an ISS mission, DXA BMD and TBS are detecting different effects of ARED exercise and of ARED + Bisphosphonate on the lumbar spine of astronauts. There is emerging evidence associating reduced TBS with terrestrial metabolic bone disorders where a TBS <1.200 is associated with "degraded" while > 1.350 is associated with "normal." However, it is not possible to conclude how the spaceflight-induced changes in TBS increase risk for vertebral fractures in the astronaut or if changes in body composition of the trunk region could be an indirect method of assessing exercise effect on bone microarchitecture. More importantly, this pilot analysis demonstrates a new, minimal risk approach for monitoring changes to vertebral bone microarchitecture. This method could help assess the combined skeletal effects of spaceflight with the effects of aging in the astronaut after return to Earth.

Sibonga, J. D.↗

Molecular Structure of Sphingomyelin in Fluid Phase Bilayers Determined by the Joint Analysis of Small-Angle Neutron and X-ray Scattering Data

In this work, we have determined the fluid bilayer structure of palmitoyl sphingomyelin (PSM) and stearoyl sphingomyelin (SSM) by simultaneously analyzing small-angle neutron and X-ray scattering data. Using a newly developed scattering density profile (SDP) model for sphingomyelin lipids, we report structural parameters including the area per lipid, total bilayer thickness, and hydrocarbon thickness, in addition to lipid volumes determined by densitometry. Unconstrained all-atom simulations of PSM bilayers at 55 °C using the C36 CHARMM force field produced a lipid area of 56 Å 2 , a value that is 10% lower than the one determined experimentally by SDP analysis (61.9 Å2). Furthermore, scattering form factors calculated from the unconstrained simulations were in poor agreement with experimental form factors, even though segmental order parameter (S CD ) profiles calculated from the simulations were in relatively good agreement with S CD profiles obtained from NMR experiments. Conversely, constrained area simulations at 61.9 Å 2 resulted in good agreement between the simulation and experimental scattering form factors, but not with S CD profiles from NMR. We discuss possible reasons for the discrepancies between these two types of data that are frequently used as validation metrics for molecular dynamics force fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying uncertainty in uranium concentration measurements via K-edge densitometry

This study quantifies the uncertainty in uranium concentration predictions of fluoride and chloride-based salts within a steel pipe using K-edge densitometry. Modeling and simulation was conducted with the Monte Carlo N-Particle Transport (MCNP) code. The quality of of this technique’s prediction in a pipe requires proper characterization of the pipe’s thickness, which is dependent on the source size and axial offset from the pipe centerline. The thickness was determined as either the center-line thickness seen by the X-ray source or an average value determined through random sampling. Generally, the predicted concentrations were slightly better at lower offset with the random sampling thickness and using the center-line thickness for the highest offsets. For a line-beam source and varying axial offsets, the relative error of concentration was within 1% of the true value but uncertainty increased by 2 orders of magnitude. Similarly, for no axial offset, the relative error was significantly less than 1% while no trend for uncertainty was found. However, at the largest possible offset for a given source size, the concentrations become erroneous and greater than the allowable 1% relative error. Furthermore, high offsets tended to increase the variance of the transmission spectra by 3 orders of magnitude.

Characterization and Analytical Technique↗

Three Dimensional Cross-Sectional Properties From Bone Densitometry

Bone densitometry has previously been used to obtain cross-sectional properties of bone in a single scan plane. Using three non-coplanar scans, we have extended the method to obtain the principal area Moments of inertia and orientations of the principal axes at each cross-section along the length of the scan. Various 5 aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of mass distribution. Factors considered included X-ray photon energy, initial scan orientation, the included angle of the 3 scans, and Imin/Imax ratios. Principal moments of inertia were accurate to within 3.1% and principal angles were within 1 deg. of the expected value for phantoms scanned with included angles of 60 deg. and 90 deg. at the higher X-ray photon energy. Low standard deviations in error also 10 indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 deg. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (Imin/Imax) values when various included angles are used make this technique viable for future in vivo studies.

Cleek, Tammy M.↗