Search NASA⌕ Search

SEARCH · Search NASA

Results for “Density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Technique for an improved and time-resolved carbon areal density measurement with a single channel diagnostic for inertial confinement fusion

Measurement of the areal density and velocity of the carbon ablator shell during peak burn in inertial confinement fusion give powerful information on the state of the ablator and where in the trajectory of implosion it reaches peak burn. Detailed comparison of the absolute densities and velocities of the carbon in implosions has been prevented by the limited ability to resolve shot-to-shot variation within a shot series or within a campaign. Here, a new approach using a single, ultra fast (~10 ps) gamma ray channel can massively reduce uncertainties and will provide insights on improvements to target and drive variables. Small improvements in these experimental design parameters may result in much greater yields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Size and Density Measurement

This project has developed a miniature gravity settling classifier (flow cell) and flow system that separates slurry particles by settling rate into six different Cuts. The settling rates for particles in each Cut were determined from COMSOL computational fluid dynamics (CFD) modeling of the flow in the flow cell together with particle tracking for particles of differing settling rates. For particles collected in each Cut, the particle concentration and size distribution were measured. The effective particle densities from each Cut are calculated from their respective CFD modeled settling rates using a relationship between the unhindered settling rate, particle size distribution (PSD), and effective density. The particle size and density distribution (PSDD) of the slurry sample is then calculated by combining the size and density distributions determined for the particles collected in each of the settling rate Cuts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of spatially and temporally resolved electron density measurements for the assessment of radiation hydrodynamics simulations of laboratory X-ray photoionized plasmas

The photoionized plasma gas cell experiment is an established platform we use to make at-parameter (ξ > > 1 ergs cm s –1 ) measurements of plasma properties with application to high-energy astrophysical systems. We model the experiments with 1D radiation hydrodynamics simulations using the HELIOS-CR code to inform our understanding and assist in the interpretation of results. The simulations predict that the bulk of the plasma is in a quasi-uniform and hydrodynamically unperturbed state throughout the duration of the experiment. To evaluate this prediction, we introduced a photonic Doppler velocimetry (PDV) diagnostic to measure spatially and temporally resolved plasma electron density. The initial measurements were successful but had limitations that made model-data comparisons challenging. To address this, we re-designed the gas cell PDV diagnostic and doubled the number of measurement locations to sample across two thirds of the depth of the cell. We also present a comparison of the results from the upgraded PDV diagnostic to the HELIOS-CR simulations for the first time. As a result, the experimental data confirms the prediction of an unperturbed region in the bulk of the plasma but reveals discrepancies in the time evolution and spatial distribution of the simulated electron density.

79 ASTRONOMY AND ASTROPHYSICS↗

3D isotope density measurements by energy-resolved neutron imaging

Abstract Tools for three-dimensional elemental characterization are available on length scales ranging from individual atoms, using electrons as a probe, to micrometers with X-rays. However, for larger volumes up to millimeters or centimeters, quantitative measurements of elemental or isotope densities were hitherto only possible on the surface. Here, a novel quantitative elemental characterization method based on energy-resolved neutron imaging, utilizing the known neutron absorption cross sections with their ‘finger-print’ absorption resonance signatures, is demonstrated. Enabled by a pixilated time-of-flight neutron transmission detector installed at an intense short-pulsed spallation neutron source, for this demonstration 3.25 million state-of-the-art nuclear physics neutron transmission analyses were conducted to derive isotopic densities for five isotopes in 3D in a volume of 0.25 cm 3 . The tomographic reconstruction of the isotope densities provides elemental maps similar to X-ray microprobe maps for any cross section in the probed volume. The bulk isotopic density of a U-20Pu-10Zr-3Np-2Am nuclear transmutation fuel sample was measured, agrees well with mass-spectrometry and is evidence of the accuracy of the method.

36 MATERIALS SCIENCE↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Flux Density Measurements Inside the Z Environment Chamber During Warm X-Ray Shots

The peak magnetic flux density was measured as 148.7 T in the axial direction, at a distance of 41 inches from the source. This value is likely accurate as all field components fell within the 3 dB bandwidth of the accompanying balun, with the peak field component at 3.1 kHz. No field structure could be identified during the test series, suggesting the Z-pinch may create a “mode-stirred” EM environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of limited coverage effects on areal density measurements in inertial confinement fusion implosions

Accurate diagnosis of areal density ($\textit{ρR}$) is critical for the inference of performance metrics in inertial confinement fusion implosions. One potential source of error in this diagnosis is the existence of low mode perturbations in the imploding target, which lead to asymmetries in the inference of the $\textit{ρR}$ from different lines of sight. Here, the error accrued as a result of limited coverage of the sphere due to a finite number of detectors is quantified, and the development of a forward scatter measurement from the OMEGA neutron time-of-flight detectors is motivated. In this work, a method by which the 1D-equivalent 4 π-averaged $\langleρR\rangle$ can be reconstructed, if accurate mode information can be diagnosed by other means, is validated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density Measurements of Molten LiF–BeF 2 and LiF–BeF 2 –LaF 3 Salt Mixtures by Neutron Radiography

The densities of eutectic (LiF) 2 –BeF 2 and mixtures of this salt (FLiBe) with LaF 3 were measured by dilatometry and by neutron attenuation from 673 K to 1,073 K. Because LaF 3 has a limited solubility in FLiBe, it was necessary to determine the amount of LaF 3 in solution before the density could be determined. The FLiBe density determination was favorably benchmarked against the literature data. A simple comparison was not available for the LaF 3 –FLiBe mixtures, so extrapolation of published data was necessary based on analysis using the Molten Salt Thermal Properties Database-Thermochemistry, or MSTDB-TC, developed by the US Department of Energy. Solubilities for LaF 3 in FLiBe ranged from 1 to 4 mol % over 673 to 1,073 K. The salt system was heated and cooled over 24 h to evaluate potential changes in composition and hysteresis during the measurement. Changes in the meniscus were observed, and these were included in the correction for density determinations. Salt surface tension may have led to supersaturation of LaF 3 in the salt because the solubility curve was nonlinear with respect to the inverse temperature, as would be expected for an ideal system. Surface tension measurements are currently underway to test this hypothesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plating and Stripping of Lithium Metal Stabilized by a Block Copolymer Electrolyte: Local Current Density Measurement and Modeling

Here, plating and stripping of lithium protrusions in lithium metal symmetric cells containing a solid block copolymer electrolyte was studied as a function of time in 3D using time-resolved X-ray tomography. These measurements enabled determination of the spatial variation in current densities at the plating and stripping electrodes. The initial interelectrode distance was 27 μm. Correlation functions were calculated to reveal the relationships between current densities at the two electrodes and local electrolyte thickness. Current densities at opposing electrode locations during protrusion growth is uncorrelated until the local interelectrode distance decreases to less than 6 μm, just before the cell shorts. Mass balance was used to determine the area from which lithium ions that form a protrusion were stripped. Computational modeling of the plating and stripping process reveals the interplay between electrochemical and mechanical driving forces and their effect on nonuniform current distribution. Model predictions were compared with experiments without resorting to any adjustable parameters. The computed correlation functions were in qualitative agreement with experiments. Finally, the model was used to calculate contour plots of electrochemical potential within the electrolyte, shedding light on how geometry, salt concentration, interelectrode distance, and mechanical stress influence local rates of electrochemical reaction.

36 MATERIALS SCIENCE↗

Electron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma

We report a comparison of inferred electron density (n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature (T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He + and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum energy density measured from cosmological data

Within the ΛCDM cosmological model, the absolute value of Einstein's cosmological constant Λ, sometimes expressed as the gravitating mass-energy density ρΛ of the physical vacuum, is a fundamental constant of nature, whose accurate measurement plays a central role in testing some proposed theories of quantum gravity. Several combinations of currently public cosmological data and an assumed flat ΛCDM cosmological model are used here to make a joint Bayesian inference on the combination of conventional parameters Ω Λ h 2 that corresponds to the absolute physical density ρΛ. In physical units, we obtain ρ Λ = (60.3 ± 1.3)× 10 -31 g/cm 3 , the most accurate constraint to date, with an absolute calibration of cosmological measurements based on CMB temperature. Significantly different values are obtained with calibrations that use a local distance scale, mainly connected to systematic differences in the value of the Hubble constant. Furthermore, it is suggested that future comprehensive cosmological parameter studies assuming the ΛCDM model include constraints on the vacuum density.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute ion density measurements in the afterglow of a radiofrequency atmospheric pressure plasma jet

Atmospheric pressure plasma jets (APPJs) can enable large fluxes of reactive species impinging on treated substrates in many applications. The relative importance of ionic versus neutral reactive species fluxes produced by APPJs is to date mainly deduced from modeling due to the challenge of measuring absolute ion densities/fluxes. In this study, a calibration was performed to determine the absolute densities of cold ions in the afterglow region of an RF-driven atmospheric pressure plasma jet (APPJ) in Ar + 1% O 2 by molecular beam mass spectrometry. Here, positive ion densities were found to be about 3-4 orders of magnitudes lower than the densities of the dominant reactive neutral species (O, O 2 (a 1 Δ g ), O 3 ) in the afterglow region of the APPJ at a distance larger than 2 mm from the visible plasma plume. The results illustrate the ability of molecular beam mass spectrometry to enable a quantitative evaluation of both neutral and ionic species in many applications using APPJs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of XCT for Matrix Density Measurement of Particle Fuel Forms

Particle fuel forms generally consist of a dispersion of fuel, such as tristructural isotropic (TRISO) particles, within a refractory matrix (e.g., graphite or silicon carbide). The density of matrix materials for particle fuel forms is of interest for modeling fuel form strength and thermal properties and may be specified as a quality control parameter, depending on reactor design. Some of the uncertainty associated with traditional, manual approaches can be eliminated by performing x-ray computed tomography (XCT) on the fuel forms and applying image processing methods to generate a precise count of the number of particles. This also removes the need to include determination of particle count within each individual fuel form during fabrication. Unfortunately, reconstruction artifacts from high-Z uranium-bearing kernels prevent accurate measurement of individual particle volumes using this approach, so the use of mean particle mass and volume are still necessary for computation of average fuel form matrix density. This method of using XCT to count particles in individual fuel form for determination of average matrix density was applied to three archived compacts from the Advanced Gas Reactor Fuel Development and Qualification (AGR)-1 campaign, four archived compacts with uranium carbide/uranium oxide (UCO) TRISO from the AGR-2 campaign, and three archived UO 2 -TRISO compacts from the AGR-2 campaign. The resulting density values were compared with those previously reported, showing slight changes due to uncertainties in the previously used number of particles in each of these cylindrical, graphite matrix compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extreme compression of planetary gases: High-accuracy pressure-density measurements of hydrogen-helium mixtures above fourfold compression

Hydrogen (H 2 ) and helium (He), the most abundant elements in the universe, pose a unique challenge in measuring the equation of state of the mixture, owing to their differing physical properties. There remains a need for data with high enough precision to discriminate between existing equation of state (EOS) mix models in order to understand the internal structure of gas-giant planets. Here, we have measured the EOS of precompressed H 2 - He mixtures at conditions directly relevant to the planetary interiors using hypervelocity gas guns and Sandia’s Z machine with less than 10% uncertainty in density, enabling validation of mixture models. We precompressed 50:50 molar mixtures of H 2 -He to 0.1–0.2 GPa and directly measured particle velocity (in gas-gun experiments) and shock velocities (in Z-machine experiments). To complement the experimental efforts, we also computed the Hugoniots of precompressed H 2 -He mixtures using density-functional-theory-based molecular dynamics. Furthermore, we observe approximately 3- to 4.3-fold density compression at pressures up to 44 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

A tensor density measure of topological charge in three dimensional nematic phases

A path-independent measure in order parameter space is introduced such that, when integrated along any closed contour in a three-dimensional nematic phase, it yields the topological charge of any line defects encircled by the contour. A related measure, when integrated over either closed or open surfaces, reduces to known results for the charge associated with point defects (hedgehogs) or Skyrmions. We further define a tensor density, the disclination density tensor D, from which the location of a disclination line can be determined. This tensor density has a dyadic decomposition near the line into its tangent and its rotation vector, allowing a convenient determination of both. The tensor D may be non-zero in special configurations in which there are no defects (double-splay or double-twist configurations), and its behaviour there is provided. The special cases of Skyrmions and hedgehog defects are also examined, including the computation of their topological charge from D.

36 MATERIALS SCIENCE↗

A tensor density measure of topological charge in three dimensional nematic phases

A path independent measure in order parameter space is introduced such that, when integrated along any closed contour in a three dimensional nematic phase, it yields the topological charge of any line defects encircled by the contour. A related measure, when integrated over either closed or open surfaces, reduces to known results for the charge associated with point defects (hedgehogs) or Skyrmions. We further define a tensor density, the disclination density tensor D, from which the location of a disclination line can be determined. This tensor density has a dyadic decomposition near the line into its tangent and its rotation vector, allowing a convenient determination of both. The tensor D may be nonzero in special configurations in which there are no defects (double-splay or double-twist configurations), and its behavior there is provided. The special cases of Skyrmions and hedgehog defects are also examined, including the computation of their topological charge from D.

36 MATERIALS SCIENCE↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗