Search NASA⌕ Search

SEARCH · Search NASA

Results for “Denver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Low-Temperature Geothermal Play Fairway Analysis for the Denver Basin

This project is part of a national initiative to showcase the benefits of incorporating low-temperature geothermal resource assessment into the deployment of geothermal heating, combined heat and power (CHP), and geothermal direct-use (GDU) technologies. The initiative was established to accelerate the country's decarbonization efforts by identifying potential for low-temperature geothermal resource utilization (<150 degrees C, e.g., CHP and GDU) in selected sedimentary basins with numerous population centers. The play fairway analysis (PFA) methodologies in this study were adapted from previous PFA investigations of sedimentary basin geothermal play types (SBGPTs) that evaluated the potential for low-temperature resources (<150 degrees C). Workflows, relevant datasets, a new Python library, and common and composite geological criteria maps are utilized to develop low-temperature geothermal resource favorability maps for the Denver Basin, a sedimentary basin spanning Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. To facilitate future assessment of low-temperature geothermal resources in SBGPTs, this project provides PFA workflows, data, tools, and favorability maps that will ultimately support the utilization of low-temperature geothermal resources in sedimentary basins.

combined heat and power↗

AmeriFlux US-DUF Denver Urban Field Station

This is the AmeriFlux version of the carbon flux data for the site US-DUF Denver Urban Field Station. Site Description - This site was established on a 25m freestanding former radio tower at the Forest Service's Rocky Mountain Research Station headquarters in Fort Collins, CO. The tower is situated next to a parking lot and several one and two story buildings. To the north and west is the campus of Colorado State University, and to the north and east is low density residential development. To the south and east are a busy intersection and rapid transit bus line, and to the south is green space surrounding the City of Fort Collins' Spring Creek Trail.

Frank, John [US Forest Service, Rocky Mountain Res↗

2011 Residential Energy Efficiency Technical Update Meeting Summary Report: Denver, Colorado - August 9-11, 2011

This report provides an overview of the U.S. Department of Energy Building America program's Summer 2011 Residential Energy Efficiency Technical Update Meeting. This meeting was held on August 9-11, 2011, in Denver, Colorado, and brought together more than 290 professionals representing organizations with a vested interest in energy efficiency improvements in residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Air Sealing Demonstration: Denver Federal Center Building 40

This project aimed to demonstrate building airtightness achieved by automated air sealing in a commercial building setting. The automated air sealing demonstrated in this project uses a modified blower door to pressurize and distribute the sealing aerosol to achieve the required building airtightness. To demonstrate this technology, Building 40 at the Denver Federal Center, a federally owned campus under the jurisdiction, custody and control of the U.S. General Services Administration (GSA), was selected for testing (Figure 2). This building is currently undergoing several retrofit projects, including increasing insulation, installing high-performance windows, and adding advanced equipment, control systems, and automated air sealing. This demonstration project involved installing automated air sealing and measuring the improvements in the building's airtightness. The automated air sealing was installed over two days by AeroBarrier, the vendor. An external blower door test contractor measured the airtightness of the demonstration space before and after air sealing. The new airtightness value and the percentage increase in airtightness were used to evaluate the energy savings potential of automated air sealing. These airtightness values were used to compute the energy savings and CO 2 emissions reduction for different climate zones, building types, and initial airtightness conditions. In addition, the heating, ventilation and air conditioning (HVAC) load reduction attributable to the reduced building air leakage was studied. This study included research to determine the cost and time reduction of automated air sealing. Finally, the automated air sealing performance was evaluated qualitatively using a focus group discussion that included GSA and Bristol, the general contractor. The installation has shown the demonstration site, with a floor size of 4,462 ft 2 , air leakage has reduced by more than 50% in less than 7 hours, including preparation, site sealing, and cleanup. The performance objectives were classified as quantitative or qualitative based on the evaluation metrics used to assess the project’s success. The key performance objectives for this project were the level of airtightness achieved, the time and cost required to perform the sealing, and the HVAC load reduction attributable to air sealing. Table 1 shows the quantitative performance objectives.

42 ENGINEERING↗

High-Penetration Photovoltaics Standards and Codes Workshop, Denver, Colorado, May 20, 2010: Workshop Proceedings

Effectively interconnecting high-level penetration of photovoltaic (PV) systems requires careful technical attention to ensuring compatibility with electric power systems. Standards, codes, and implementation have been cited as major impediments to widespread use of PV within electric power systems. On May 20, 2010, in Denver, Colorado, the National Renewable Energy Laboratory, in conjunctionwith the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), held a workshop to examine the key technical issues and barriers associated with high PV penetration levels with an emphasis on codes and standards. This workshop included building upon results of the High Penetration of Photovoltaic (PV) Systems into the Distribution Grid workshop held in OntarioCalifornia on February 24-25, 2009, and upon the stimulating presentations of the diverse stakeholder presentations.

14 SOLAR ENERGY↗

Estimating Total Methane Emissions from the Denver-Julesburg Basin Using Bottom-Up Approaches

Methane is a powerful greenhouse gas with a 25 times higher 100-year warming potential than carbon dioxide and is a target for mitigation to achieve climate goals. To control and curb methane emissions, estimates are required from the sources and sectors which are typically generated using bottom-up methods. However, recent studies have shown that national and international bottom-up approaches can significantly underestimate emissions. In this study, we present three bottom-up approaches used to estimate methane emissions from all emission sectors in the Denver-Julesburg basin, CO, USA. Our data show emissions generated from all three methods are lower than historic measurements. A Tier 1/2 approach using IPCC emission factors estimated 2022 methane emissions of 358 Gg (0.8% of produced methane lost by the energy sector), while a Tier 3 EPA-based approach estimated emissions of 269 Gg (0.2%). Using emission factors informed by contemporary and region-specific measurement studies, emissions of 212 Gg (0.2%) were calculated. The largest difference in emissions estimates were a result of using the Mechanistic Air Emissions Simulator (MAES) for the production and transport of oil and gas in the DJ basin. The MAES accounts for changes to regulatory practice in the DJ basin, which include comprehensive requirements for compressors, pneumatics, equipment leaks, and fugitive emissions, which were implemented to reduce emissions starting in 2014. The measurement revealed that normalized gas loss is predicted to have been reduced by a factor of 20 when compared to 10-year-old normalization loss measurements and a factor of 10 less than a nearby oil and production area (Delaware basin, TX); however, we suggest that more measurements should be made to ensure that the long-tail emission distribution has been captured by the modeling. This study suggests that regulations implemented by the Colorado Department of Public Health and Environment could have reduced emissions by a factor of 20, but contemporary regional measurements should be made to ensure these bottom-up calculations are realistic.

03 NATURAL GAS↗

Long-term evaluation of air sensor technology under ambient conditions in Denver, Colorado

Air pollution sensors are quickly proliferating for use in a wide variety of applications, with a low price point that supports use in high-density networks, citizen science, and individual consumer use. This emerging technology motivates the assessment under real-world conditions, including varying pollution levels and environmental conditions. A seven-month, systematic field evaluation of low-cost air pollution sensors was performed in Denver, Colorado, over 2015–2016; the location was chosen to evaluate the sensors in a high-altitude, cool, and dry climate. A suite of particulate matter (PM), ozone (O 3 ), and nitrogen dioxide (NO 2 ) sensors were deployed in triplicate and were collocated with federal equivalent method (FEM) monitors at an urban regulatory site. Sensors were evaluated for their data completeness, correlation with reference monitors, and ability to reproduce trends in pollution data, such as daily concentration values and wind-direction patterns. Most sensors showed high data completeness when dataloggers were functioning properly. The sensors displayed a range of correlations with reference instruments, from poor to very high (e.g., hourly-average PM Pearson correlations with reference measurements varied from 0.01 to 0.86). Some sensors showed a change in response to laboratory audits/testing from before the sampling campaign to afterwards, such as Aeroqual, where the O 3 response slope changed from about 1.2 to 0.6. Some PM sensors measured wind-direction and time-of-day trends similar to those measured by reference monitors, while others did not. This study showed different results for sensor performance than previous studies performed by the U.S. EPA and others, which could be due to different geographic location, meteorology, and aerosol properties. These results imply that continued field testing is necessary to understand emerging air sensing technology.

54 ENVIRONMENTAL SCIENCES↗

Reservoir Characterization and Techno-Economic Analysis of Enhanced Geothermal and Closed-Loop Systems in the Wattenberg Field of the Denver-Julesburg Basin, Colorado

This report provides details of reservoir characterization and techno-economic analysis for enhanced geothermal systems and closed-loop geothermal systems in the Denver-Julesburg Basin Wattenberg area. The analysis contributes to the Geothermal Limitless Approach to Drilling Efficiencies (GLADE) project, a multi-institutional research initiative focused on advancing geothermal energy development by reducing drilling costs and improving the rate of penetration. The GLADE project brings together national laboratories, academic institutions, and industry partners, including the U.S. Department of Energy's Geothermal Technologies Office, Occidental Petroleum, the National Laboratory of the Rockies (NLR), Los Alamos National Laboratory, Colorado School of Mines, Louisiana State University, Texas A&M University, and several drilling technology companies. As part of this effort, NLR developed and applied slender-body theory modeling tools and the GEOPHIRES simulator to support techno-economic analysis. The slender-body theory wellbore simulator evaluated thermal performance in U-loop, Eavor-type multilateral, and enhanced geothermal system well configurations. Results indicated that an optimized single U-loop design delivers an outlet temperature of 168.8 degrees Celsius,stabilizing at a final outlet temperature of 135.3 degrees Celsius. Heat production also improved significantly, with an average thermal output of 16.9 MWth and a final thermal output of 11.0 MWth. These results provided critical baseline data for selecting optimized systems for techno-economic analysis. Building on these outputs, NLR applied the GEOPHIRES techno-economic simulator to estimate the levelized cost of electricity for both the Eavor multilateral and enhanced geothermal systems. The sensitivity analysis showed that drilling costs exert a particularly strong impact on the levelized cost of electricity of multilateral systems. Therefore, advances in drilling technology and improved drilling rates could yield significant gains in the economic performance of these systems. In this context, the GLADE project directly supports the U.S. Department of Energy's mission to reduce the cost of geothermal energy and accelerate the deployment of next-generation geothermal technologies.

15 GEOTHERMAL ENERGY↗

Preliminary results from the University of Denver infrared spectrometer - 1977 intertropical convergence zone experiment

The Denver University Infrared Spectrometer (DUIRS) is a liquid-helium-cooled emission radiometer designed to study minor atmospheric constituents. DUIRS flew on 12 data flights during the 1977 Intertropical Convergence Zone experiment. No data were obtained on the flight from Wallops Island to Panama because of a power failure or on the return flight to Wallops Island because of a cryogen line freeze-up. The data coverage on the nine vertical profile flights that were flown before the freeze-up are shown. Typical spectra and variations as a function of U-2 (research aircraft) altitude are also shown. Radio metric data and rawinsonde temperature data were used to perform band model calculations to obtain molecular number densities in the column above the aircraft at each altitude.

Barker, D. B.↗

Operational wind shear detection and warning - The 'CLAWS' experience at Denver and future objectives

An operational wind shear detection and warning experiment was conducted at Denver's Stapleton International Airport in summer 1984. Based on meteorological interpretation of scope displays from a Doppler weather radar, warnings were transmitted to the air traffic control tower via voice radio. Analyses of results indicated real skill in daily microburst forecasts and very short-term (less than 5-min) warnings. Wind shift advisories with 15-30 min forecasts, permitted more efficient runway reconfigurations. Potential fuel savings were estimated at $875,000/yr at Stapleton. The philosophy of future development toward an automated, operational system is discussed.

Mccarthy, John↗

Analysis of records from four airliners in the Denver microburst, July 11, 1988

Flight and radar position records are analyzed to determine the winds encountered by four airliners that penetrated a multicell microburst on approach to Denver's Stapleton International Airport. The results show significant expansion in the size of the microburst, and indicate that there were fluctuations in the internal wind velocity. At its peak strength, as experienced by the second aircraft, the microburst produced a head-wind-to-tail-wind shear of 115 ft/sec. The wind patterns derived from the flight-data analysis are in general agreement with results derived from Doppler weather radar and from a numerical microburst simulation.

Coppenbarger, R. A.↗

Synthetic Aperture Radar Imagery of Airports and Surrounding Areas: Denver Stapleton International Airport

This is the third in a series of three reports which address the statistical description of ground clutter at an airport and in the surrounding area. These data are being utilized in a program to detect microbursts. Synthetic aperture radar (SAR) data were collected at the Denver Stapleton Airport using a set of parameters which closely match those which are anticipated to be utilized by an aircraft on approach to an airport. These data and the results of the clutter study are described. Scenes of 13 x 10 km were imaged at 9.38 GHz and HH-, VV-, and HV-polarizations, and contain airport grounds and facilities (up to 14 percent), cultural areas (more than 50 percent), and rural areas (up to 6 percent). Incidence angles range from 40 to 84 deg. At the largest depression angles the distributed targets, such as forest, fields, water, and residential, rarely had mean scattering coefficients greater than -10 dB. From 30 to 80 percent of an image had scattering coefficients less than -20 dB. About 1 to 10 percent of the scattering coefficients exceeded 0 dB, and from 0 to 1 percent above 10 dB. In examining the average backscatter coefficients at large angles, the clutter types cluster according to the following groups: (1) terminals (-3 dB), (2) city and industrial (-7 dB), (3) warehouse (-10 dB), (4) urban and residential (-14 dB), and (5) grass (-24 dB).

Onstott, Robert G.↗

The 11 July 1988 Denver windshear encounters

On July 11, 1988, between 2207 and 2213 UTC (16:07 to 16:13 MDT), four successive United flights had inadvertent encounters with microburst windshear conditions while on final approach to Denver Stapleton Airport (DEN), each resulting in a missed approach, subsequent delay, and uneventful arrival. A fifth flight executed a missed approach without encountering the phenomena. There was no damage to aircraft and no passenger injuries were incurred. The term inadvertent is used within United Airlines' windshear training materials and the Federal Aviation Administration (FAA) Windshear Training Aid to connote an encounter with windshear after vigilance and cautionary practices fail to identify and afford complete avoidance of the hazardous area. No crew culpability is implied. A comprehensive investigation for scientific purposes in the study of windshear phenomenon is being conducted separately under the guidance of the FAA with involvement and cooperation from United, the National Transportation Safety Board (NTSB), National Center for Atmospheric Research (NCAR), Boeing, Douglas, NASA, and others.

Ireland, Robert L.↗

Three-dimensional simulation of the Denver 11 July Storm of 1988 - An intense microburst event

An account is given of results from a numerical simulation of an intense microburst-generating storm observed near Denver during a test operation of the Terminal Doppler Radar System, on July 11, 1988. The numerical simulation encompassed comparisons with 'observed' data from measurements by Doppler radar, aircraft flight data recorders, and surface field instruments. Model results are in excellent qualitative and quantitative agreement with major storm feature observations. The intense microburst that was generated some distance 'downshear' of the primary precipitation area was driven by cooling due to sublimating snow.

Proctor, Fred H.↗

Three-dimensional simulation of the Denver 11 July 1988 microburst-producing storm

A simulation of the July 11, 1988 thunderstorm near Denver, which produced a microburst of unusual intensity during the test operation of the Terminal Doppler Weather Radar system is carried out using the Terminal Area Simulation System also known as the NASA-Langley Windshear Model. The results show the evolution and structure of the storm, including hazard indices based on F-factor. Results of simulation show that the storm is of unusual structure, producing multiple low- to moderate-reflectivity microbursts formed downshear of the main precipitation shaft. The most intense of the microbursts contains a velocity differential exceeding 40 m/s, strong downdrafts, and hazardous windshear with F-factors approaching 0.2. A comparison with observations, including Doppler radar measurements and aircraft flight data, indicates that the model can proivide information that is not always apparent from observed data.

Proctor, F. H.↗

Case study of a low-reflectivity pulsating microburst - Numerical simulation of the Denver, 8 July 1989, storm

An intense, low-reflectivity, and pulsating microburst event, detected on July 8, 1989 by the Low-Level Windshear Alert System north of Denver Stapleton Airport is described using a Terminal Area Simulation System (TASS) model (Proctor, 1987). This 3d nonhydrostatic cloud model includes parametrizations for both liquid- and ice-phase microphysics. Simulation results show that the dissipating cloud induces a type-1 pulsating microburst event, with at least three distinct microburst pulses over a period of 20 min. Virga from the dissipating cloud continued to maintain hazardous windshear for a period much longer than the typical lifetime of a single microburst.

Proctor, Fred H.↗