Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SU-F-T-557: Evaluation of Detector Response in Rectangular Small Field Dosimetry

Purpose: As stereotactic treatment modalities grow towards becoming the standard of care, the need for accurate dose computation in small fields is becoming increasingly essential. The purpose of this study is to evaluate the response of different detectors, intended for small field dosimetry, in jaw defined small rectangular fields by analyzing output factors from a stereotactic clinical accelerator. Methods: Two Dosimeters, the Exradin A26 Microionization Chamber (Standard Imaging) and Edge Diode Detector (Sun Nuclear) were used to measure output factors taken on the Varian Edge Stereotactic Linear accelerator. Measurements were taken at 6MV and 6FFF at 10cm depth, 100cm SSD in a 48×48×40cm3 Welhoffer BluePhantom2 (IBA) with X and Y jaws set from 0.6 to 2.0cm. Output factors were normalized to a 5×5cm2 machine-specific reference field. Measurements were made in the vertical orientation for the A26 and horizontal orientation for both the A26 and Edge. Output factors were measured as: OF{sub FS} = M{sub FS}/M{sub ref} where M{sub FS} and M{sub ref} are the measured signals for the clinical field and the reference field, respectively. Measured output factors were then analyzed to establish relative responses of the detectors in small fields. Results: At 6MV the Edge detector exhibited a variation in output factors dependent on jaw positioning (X-by-Y vs Y-by-X) of 5.7% of the 5×5cm reference output and a variation of 3.33% at 6FFF. The A26 exhibited variation of output factor dependent on jaw positioning of upto 7.7% of the 5×5cm reference field at 6MV and upto 5.33% at 6FFF. Conclusion: Both the Edge detector and A26 responded as expected at small fields however a dependence on the jaw positioning was noted. At 6MV and 6FFF the detector response showed an increased dependence on the positioning of the X jaws as compared to the positioning of the Y jaws.

60 APPLIED LIFE SCIENCES↗

Experimental validation of scintillator detector response to correlated neutrons with MCNP and associated packages

Time, energy, and angle correlated neutrons are emitted in nuclear fission. New, physics-based fission event generators that capture these correlations have been incorporated into MCNP6.2 because correlations can impact nuclear non-proliferation and safeguards systems response. DRiFT is a detector response code that takes MCNP outputs and reproduces laboratory analogous detector quantities. Previous work has compared DRiFT to single detector experiment data and has discussed recent updates to DRiFT specific to correlated fission experiments. In this work, we demonstrate a validation of recent updates to DRiFT for organic scintillator response in correlated fission neutron experiments using a 252Cf source. Furthermore, outputs from MCNP with the FREYA fission event generator were post-processed with DRiFT and compared to experiment data. Simulation and experiment results are in reasonably good agreement for multiple correlated neutron quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generative machine learning for detector response modeling with a conditional normalizing flow

In this paper, we explore the potential of generative machine learning models as an alternative to the computationally expensive Monte Carlo (MC) simulations commonly used by the Large Hadron Collider (LHC) experiments. Our objective is to develop a generative model capable of efficiently simulating detector responses for specific particle observables, focusing on the correlations between detector responses of different particles in the same event and accommodating asymmetric detector responses. Here, we present a conditional normalizing flow model ($\mathcal{CNF}$) based on a chain of Masked Autoregressive Flows, which effectively incorporates conditional variables and models high-dimensional density distributions. We assess the performance of the $\mathcal{CNF}$ model using a simulated sample of Higgs boson decaying to diphoton events at the LHC. We create reconstruction-level observables using a smearing technique. We show that conditional normalizing flows can accurately model complex detector responses and their correlation. This method can potentially reduce the computational burden associated with generating large numbers of simulated events while ensuring that the generated events meet the requirements for data analyses. We make our code available at https://github.com/allixu/normalizing_flow_for_detector_response

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon detector response function methodology using MCNP and shift hybrid radiation transport code for wide-area contamination assay applications

Here, radiation transport modeling using the Monte Carlo N-Particle (MCNP) radiation transport code and Monte Carlo code, Shift, were employed to model detector responses for a variety of wide-area photon contamination scenarios. In this study, 2" × 2" and 3" × 3" cylindrical NaI(Tl) scintillation detector configurations at source detector-distances of 0.5 cm, 1 cm, 2.54 cm, 10 cm, and 30 cm were modeled. Media of soil, concrete, and steel were evaluated for contamination depths ranging from surface to a depth of an infinite thickness in each medium for photon energies ranging from 20 keV to 3 MeV, which correspond to the energies that current detectors can discern. Monoenergetic photon surface contamination detector responses for each of the media, source–detector distances, and detectors were estimated using MCNP v6.2. Shift was harnessed for improved variance reduction of particle transport in highly attenuating media to obtain average cell fluxes in the two MCNP NaI(Tl) scintillation detector configurations. Average cell flux values in Shift were coupled with detector responses from MCNP to convert average cell flux in a void to energy distribution of pulses in the NaI(Tl) scintillation detector crystal of interest. An optimized detector response function methodology was developed by coupling the MCNP radiation transport method with the Consistent Adjoint Driven Importance Sampling (CADIS) hybrid radiation transport method built into Shift to significantly decrease the runtime of thousands of MCNP pulse height simulations. The methodology may be utilized to quickly and accurately facilitate the assessment of a broad range of wide-area environmental contamination assay and decommissioning cleanup applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Material-Dependent Detector Responses for Airborne Gamma-Ray Spectroscopy

The aim of this work is to create a library of predicted detector responses used for real-time background estimation during airborne gamma-ray spectroscopy. The simulated spectra are a function of naturally occurring radioactive potassium, uranium, and thorium (KUT) and radioactive daughter products which are present in terrestrial-based materials. Self-attenuation within these materials varies, such that the gamma spectra emitted from the surfaces can differ, despite all having KUT origins. This study also compared various simulated detector responses among materials to determine if some could be accurately scaled from another across reasonable helicopter altitudes and orientations, relative to the ground. Results show that materials with comparable sample thicknesses can be scaled consistently across altitude. This work allows for efficient background estimation via aggregation of simulated detector responses in real time.

radioactive potassium, uranium, and thorium, KUT, ↗

Organic Scintillator Detector Response Simulations with DRiFT

Here, this work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNPR output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed- field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNPR ® 6, which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discrimination plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252 Cf and PuBe, and photon spectra from 22 Na and 228 Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector-Response Correction of Two-Dimensional γ -Ray Spectra from Neutron Capture

The neutron-capture reaction produces a large variety of γ-ray cascades with different γ-ray multiplicities. A measured spectral distribution of these cascades for each γ-ray multiplicity is of importance to applications and studies of γ-ray statistical properties. The DANCE array, a 4π ball of 160 BaF2 detectors, is an ideal tool for measurement of neutron-capture γ-rays. The high granularity of DANCE enables measurements of high-multiplicity γ-ray cascades. The measured two-dimensional spectra (γ-ray energy, γ-ray multiplicity) have to be corrected for the DANCE detector response in order to compare them with predictions of the statistical model or use them in applications. The detector-response correction problem becomes more difficult for a 4π detection system than for a single detector. A trial and error approach and an iterative decomposition of γ-ray multiplets, have been successfully applied to the detector-response correction. Applications of the decomposition methods are discussed for two-dimensional γ-ray spectra measured at DANCE from γ-ray sources and from the 10B(n, γ) and 113Cd(n, γ) reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for detectors used with an 800 MU/min CyberKnife{sup ®} system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method

Purpose: In a previous work, output ratio (OR{sub det}) measurements were performed for the 800 MU/min CyberKnife{sup ®} at the Oscar Lambret Center (COL, France) using several commercially available detectors as well as using two passive dosimeters (EBT2 radiochromic film and micro-LiF TLD-700). The primary aim of the present work was to determine by Monte Carlo calculations the output factor in water (OF{sub MC,w}) and the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors. The secondary aim was to study the detector response in small beams using Monte Carlo simulation. Methods: The LINAC head of the CyberKnife{sup ®} was modeled using the PENELOPE Monte Carlo code system. The primary electron beam was modeled using a monoenergetic source with a radial gaussian distribution. The model was adjusted by comparisons between calculated and measured lateral profiles and tissue-phantom ratios obtained with the largest field. In addition, the PTW 60016 and 60017 diodes, PTW 60003 diamond, and micro-LiF were modeled. Output ratios with modeled detectors (OR{sub MC,det}) and OF{sub MC,w} were calculated and compared to measurements, in order to validate the model for smallest fields and to calculate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors, respectively. For the study of the influence of detector characteristics on their response in small beams; first, the impact of the atomic composition and the mass density of silicon, LiF, and diamond materials were investigated; second, the material, the volume averaging, and the coating effects of detecting material on the detector responses were estimated. Finally, the influence of the size of silicon chip on diode response was investigated. Results: Looking at measurement ratios (uncorrected output factors) compared to the OF{sub MC,w}, the PTW 60016, 60017 and Sun Nuclear EDGE diodes systematically over-responded (about +6% for the 5 mm field), whereas the PTW 31014 Pinpoint chamber systematically under-responded (about −12% for the 5 mm field). OR{sub det} measured with the SFD diode and PTW 60003 diamond detectors were in good agreement with OF{sub MC,w} except for the 5 mm field size (about −7.5% for the diamond and +3% for the SFD). A good agreement with OF{sub MC,w} was obtained with the EBT2 film and micro-LiF dosimeters (deviation less than 1.4% for all fields investigated). k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for several detectors used in this work have been calculated. The impact of atomic composition on the dosimetric response of detectors was found to be insignificant, unlike the mass density and size of the detecting material. Conclusions: The results obtained with the passive dosimeters showed that they can be used for small beam OF measurements without correction factors. The study of detector response showed that OR{sub det} is depending on the mass density, the volume averaging, and the coating effects of the detecting material. Each effect was quantified for the PTW 60016 and 60017 diodes, the micro-LiF, and the PTW 60003 diamond detectors. None of the active detectors used in this work can be recommended as a reference for small field dosimetry, but an improved diode detector with a smaller silicon chip coated with tissue-equivalent material is anticipated (by simulation) to be a reliable small field dosimetric detector in a nonequilibrium field.

07 ISOTOPE AND RADIATION SOURCES↗

Source Range Detector Response Modeling using VERA

The CASL reactor simulation package VERA has been adapted to provide high-fidelity simulation capabilities for modeling source range detector response during subcritical reactor configurations. New features include the activation and shuffling of secondary source assemblies, transfer of burned fuel neutron emission data from the ORIGEN depletion solver to the MPACT deterministic neutron transport solver, allowance of user-defined sources in MPACT based on material composition, ability to solve the subcritical source-driven system with neutron multiplication using the MPACT diffusion solver, and transfer of the calculated fission source from MPACT to the continuous energy Monte Carlo solver Shift for final detector response evaluation. These new capabilities were benchmarked against Watts Bar Unit 1 plant operating data and found to be in very good agreement.

Gentry, Cole↗

Organic Scintillator Detector Response Simulations with DRiFT

Accurate detector modeling is a requirement to design systems in many non-proliferation scenarios; by determining a Detector’s Response Function (DRF) to incident radiation, it is possible characterize measurements of unknown sources. DRiFT is intended to post-process MCNP® output and create realistic detector spectra. Capabilities currently under development include the simulation of semiconductor, gas, and (as is discussed in this work) scintillator detector physics. Energy spectra and pulse shape discrimination (PSD) trends for incident photon and neutron radiation have been reproduced by DRiFT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creating a Detector Response Matrix for the Micro-Calorimeter

To better understand the results from the micro calorimeter, a detector response matrix (DRM) was generated. This will allow to predict source responses, which in turn will improve the confidence in the instrument. To generate a DRM, the simulation package Rapid Adaptable Multi-threaded Particle and Radiation Transport Simulation (RAMPART) that utilizes underlying Geant4 libraries for particle transport was used to generate the simulation. A flat energy input spectrum ranging from 0 keV to 3000 keV was used to generate the response. 37 x 10 9 particles were simulated. In this report, the details and findings are presented.

47 OTHER INSTRUMENTATION↗

SU-F-T-490: Separating Effects Influencing Detector Response in Small MV Photon Fields

Purpose: Different detector properties influence their responses especially in field sizes below the lateral electron range. Due to the finite active volume, the detector density and electron perturbation at other structural parts, the response factor is in general field size dependent. We aimed to visualize and separate the main effects contributing to detector behavior for a variety of detector types. This was achieved in an experimental setup, shielding the field center. Thus, effects caused by scattered radiation could be examined separately. Methods: Signal ratios for field sizes down to 8 mm (SSD 90 cm, water depth 10 cm) of a 6MV beam from a Siemens Primus LINAC were recorded with several detectors: PTW microDiamond and PinPoint ionization chamber, shielded diodes (PTW P-60008, IBA PFD and SNC Edge) and unshielded diodes (PTW E-60012 and IBA SFD). Measurements were carried out in open fields and with an aluminum pole of 4 mm diameter as a central block. The geometric volume effect was calculated from profiles obtained with Gafchromic EBT3 film, evaluated using FilmQA Pro software (Ashland, USA). Results: Volume corrections were 1.7% at maximum. After correction, in small open fields, unshielded diodes showed a lower response than the diamond, i.e. diamond detector over-response seems to be higher than that for unshielded diodes. Beneath the block, this behavior was amplified by a factor of 2. For the shielded diodes, the overresponse for small open fields could be confirmed. However their lateral response behavior was strongly type dependent, e.g. the signal ratio dropped from 1.02 to 0.98 for the P-60008 diode. Conclusion: The lateral detector response was experimentally examined. Detector volume and density alone do not fully account for the field size dependence of detector response. Detector construction details play a major role, especially for shielded diodes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The detector response matrices of the burst and transient source experiment (BATSE) on the Compton Gamma Ray Observatory

The detector response matrices for the Burst And Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory (CGRO) are described, including their creation and operation in data analysis. These response matrices are a detailed abstract representation of the gamma-ray detectors' operating characteristics that are needed for data analysis. They are constructed from an extensive set of calibration data coupled with a complex geometry electromagnetic cascade Monte Carlo simulation code. The calibration tests and simulation algorithm optimization are described. The characteristics of the BATSE detectors in the spacecraft environment are also described.

Pendleton, Geoffrey N.↗

Impact of Spontaneous Fission Neutron Emission Energy on Neutron Detector Response

A parametric study was simulated in MCNP to investigate the impact of spontaneous fission neutron energy on neutron detector response. A total of 880 configurations were simulated by varying 3 He pressure and polyethylene reflector thickness for 8 different isotopes. Results showed that deviations between the simulated isotopes become more prevalent at higher energies with 238 U showing the greatest deviation. It was also observed that configurations comparable to most detection setups, 10 atm and 6 - 8 cm polyethylene, were closer to the upper bound of deviations from a 252 Cf. 240 Pu, a common spontaneous fission source of interest, ranged from 2% - 3% within this space. This suggests that further investigation is required to determine exact correction factors when calibrating neutron detectors with a 252 Cf. Although demonstrated here for a 4π-detection system, future plans include simulating a more detailed model of the MC-15 detection setup to determine exact correction factors for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-FG-207B-02: Material Reconstruction for Spectral Computed Tomography with Detector Response Function

Purpose: Different from the conventional computed tomography (CT), spectral CT based on energy-resolved photon-counting detectors is able to provide the unprecedented material composition. However, an important missing piece for accurate spectral CT is to incorporate the detector response function (DRF), which is distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. Methods: The polyenergetic X-ray forward model takes the DRF into account for accurate material reconstruction. Two image reconstruction methods are proposed: a direct method based on the nonlinear data fidelity from DRF-based forward model; a linear-data-fidelity based method that relies on the spectral rebinning so that the corresponding DRF matrix is invertible. Then the image reconstruction problem is regularized with the isotropic TV term and solved by alternating direction method of multipliers. Results: The simulation results suggest that the proposed methods provided more accurate material compositions than the standard method without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Conclusion: We have proposed material reconstruction methods for spectral CT with DRF, whichprovided more accurate material compositions than the standard methods without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Jiulong Liu and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect

Purpose: To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution-based method to address the volume averaging effect (VAE). Methods: A convolution-based approach has been proposed recently to address the ionization chamber VAE. It simulates the VAE in the treatment planning system (TPS) by iteratively convolving the calculated beam profiles with the DRF while optimizing the beam model. Since the convolved and the measured profiles are subject to the same VAE, the calculated profiles match the implicit “real” ones when the optimization converges. Three DRFs (Gaussian, Lorentzian, and parabolic function) were used for three ionization chambers (CC04, CC13, and SNC125c) in this study. Geometry dependent/independent DRFs were obtained by minimizing the difference between the ionization chamber-measured profiles and the diode-measured profiles convolved with the DRFs. These DRFs were used to obtain eighteen beam models for a commercial TPS. Accuracy of the beam models were evaluated by assessing the 20%–80% penumbra width difference (PWD) between the computed and diode-measured beam profiles. Results: The convolution-based approach was found to be effective for all three ionization chambers with significant improvement for all beam models. Up to 17% geometry dependence of the three DRFs was observed for the studied ionization chambers. With geometry dependent DRFs, the PWD was within 0.80 mm for the parabolic function and CC04 combination and within 0.50 mm for other combinations; with geometry independent DRFs, the PWD was within 1.00 mm for all cases. When using the Gaussian function as the DRF, accounting for geometry dependence led to marginal improvement (PWD < 0.20 mm) for CC04; the improvement ranged from 0.38 to 0.65 mm for CC13; for SNC125c, the improvement was slightly above 0.50 mm. Conclusions: Although all three DRFs were found adequate to represent the response of the studied ionization chambers, the Gaussian function was favored due to its superior overall performance. The geometry dependence of the DRFs can be significant for clinical applications involving small fields such as stereotactic radiotherapy.

60 APPLIED LIFE SCIENCES↗