Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffusion Coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of Experimental Methods for Estimating Matrix Diffusion Coefficients for Contaminant Transport Modeling

Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Determination of Ce 3+ , Co 2+ , Mn 2+ and Fe 2+ diffusion coefficients in Nafion® membrane

Concentration gradient diffusion coefficients for Ce 3+ , Co 2+ , Mn 2+ and Fe 2+ cations are determined in Nafion®211 membranes over a wide range of environmental conditions. Measurements are made using finite-width cation-rich bands introduced to NR211 via a hot-pressing procedure. A robust method of accurate diffusion coefficient determination of the finite-width deposits is developed using a Fick's second law of diffusion solution for one-dimensional systems. The transition metal dications are found to have nearly identical NR211 diffusion coefficients under water saturated conditions over the 22–80 °C range. The powerful chemical mitigant, Ce 3+ , is about one-half as diffusive as the dications under identical conditions. Derived diffusion coefficients for Ce 3+ and Co 2+ are found to be independent of initial cation concentration over the range of 12.5–70 mol% exchange level. The diffusion behavior of Ce 3+ in 80 °C liquid water and saturated water vapor is identical. The diffusion coefficients of Ce 3+ are shown to have a strong dependence on membrane hydration level varying by a factor of more than 30 over the range of 95 to 40% RH. Finally, the implications of these new diffusion findings are applied to a discussion of potential guidelines for the development of highly durable fuel cell systems, which employ mobile metal cations as lifetime-extending redox stabilizers.

08 HYDROGEN↗

Characterization of the fluorescence correlation spectroscopy (FCS) standard Rhodamine 6G and calibration of its diffusion coefficient in aqueous solutions

Precise diffusion measurements of rhodamine 6G (Rh6G) dissolved in D{sub 2}O at concentrations between 50 and 200 μM were carried out in the temperature range from 280 to 320 K using pulsed field gradient nuclear magnetic resonance (PFG-NMR). The obtained diffusion coefficients can be used as a calibration reference in fluorescence correlation spectroscopy (FCS). Besides measuring the diffusivity of Rh6G, the diffusion coefficient of the solvent in the same system could be determined in parallel by PFG-NMR as the resonances of water and Rh6G are well separated in the {sup 1}H NMR spectrum. To analyze the differences due to the isotope effect of the solvent (D{sub 2}O vs. H{sub 2}O), the correlation time τ{sub D} of Rh6G was measured by FCS in both D{sub 2}O and H{sub 2}O. The obtained isotopic correction factor, τ{sub D}(D{sub 2}O)/τ{sub D}(H{sub 2}O) = 1.24, reflects the isotope effect of the solvent´s self-diffusion coefficients as determined previously by PFG-NMR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of experimental methods for estimating matrix diffusion coefficients for contaminant transport modeling

Here, diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating effective matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of effective matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than effective matrix diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields effective matrix diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

54 ENVIRONMENTAL SCIENCES↗

In Situ Effective Diffusion Coefficient Profiles in Live Biofilms Using Pulsed-Field Gradient Nuclear Magnetic Resonance

Diffusive mass transfer in biofilms is characterized by the effective diffusion coefficient. It is well-documented that the effective diffusion coefficient can vary by location in a biofilm. The current literature is dominated by effective diffusion coefficient measurements for distinct cell clusters and stratified biofilms showing this spatial variation. Regardless of whether distinct cell clusters or surface-averaging methods are used, position-dependent measurements of the effective diffusion coefficient are currently: 1) invasive to the biofilm, 2) performed under unnatural conditions, 3) lethal to cells, and/or 4) spatially restricted to only certain regions of the biofilm. Invasive measurements can lead to inaccurate results and prohibit further (time dependent) measurements which are important for the mathematical modeling of biofilms. In this study our goals were to: 1) measure the effective diffusion coefficient for water in live biofilms, 2) monitor how the effective diffusion coefficient changes over time under growth conditions, and 3) correlate the effective diffusion coefficient with depth in the biofilm. We measured in situ two-dimensional effective diffusion coefficient maps within Shewanella oneidensis MR-1biofilms using pulsed-field gradient nuclear magnetic resonance methods, and used them to calculate surface-averaged relative effective diffusion coefficient (Drs) profiles. We found that 1) Drs decreased from the top of the biofilm to the bottom, 2) Drs profiles differed for biofilms of different ages, 3) Drs profiles changed over time and generally decreased with time, 4) all the biofilms showed very similar Drs profiles near the top of the biofilm, and 5) the Drs profile near the bottom of the biofilm was different for each biofilm. Practically, our results demonstrate that advanced biofilm models should use a variable effective diffusivity which changes with time and location in the biofilm.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of ICRF-Induced Ion Diffusion Coefficients Calculated with the DC and AORSA Codes

The DC (Diffusion Coefficient) code obtains RF diffusion coefficients by direct numerical integration of the Lorentz force equation for ion motion in the combined equilibrium fields and the RF full wave EM fields from the AORSA full-wave code. Suitable averaging over initial gyro- and toroidal-angle of coordinate 'kicks' after a bounce-period, gives noise-free bounce-averaged diffusion coefficients. For direct comparison with zero-banana-width coefficients from AORSA, perpendicular-drift terms in the Lorentz equation are subtracted off the integration. The DC code has been coupled to the CQL3D Fokker-Planck code. For a C-Mod minority ion ICRF heating test case, the total power absorption using the diffusion coefficients agree well, and the profiles are similarly close. This supports the DC calculation and the Kennel-Engelmann-based, no-correlations, coefficient calculation in AORSA. However, resonance correlations cause large differences in the pitch angle variations of the diffusion coefficients, and in the resulting evolution of the ion distribution functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accurate and efficient measurement of impurity (dilute) diffusion coefficients without isotope tracer experiments

We report most impurity diffusion coefficients were measured in the 1960s and 1970s using tracer experiments with only 14 sets of tracer measurements performed worldwide in the past 15 years. It is thus impractical to rely on tracer experiments to obtain the missing thousands of impurity diffusion coefficients. A recently developed forward-simulation analysis can change the scenario by reliably extracting impurity diffusion coefficients from regular diffusion couple profiles. A comparison of 51 values obtained from the forward-simulation analysis with tracer experiment values in the literature shows an excellent agreement, thus validating the reliability of the forward-simulation analysis in obtaining accurate impurity diffusion coefficients.

36 MATERIALS SCIENCE↗

Mutual Diffusion Coefficients of Na 2 SO 4 at C = 0.02989 mol·dm -3 and 298.15 K by Using Rayleigh Interferometry with Free Diffusion Boundary Conditions: Experimental Test of the Effect of the C 3/2 Concentration Dependence of Refractive Index at Low Concentration

Rayleigh interferometry is one of the most precise and accurate methods for the experimental determination of the mutual diffusion coefficients of both electrolytes and non-electrolytes in liquid solutions. For binary solutions at moderate and high concentrations where the concentration dependences of both diffusion coefficient and refractive index can be assumed to be linear or almost linear and the concentration difference ΔC between a pair of solutions undergoing free diffusion is not large compared to their average concentration, and by using proper combinations of the interference fringe positions as they vary with time, under these conditions diffusion coefficients are obtained that are independent of the size of ΔC. However, this situation becomes more complicated at low concentrations for electrolyte solutions where the concentration dependences of both the diffusion coefficient and refractive index are non-linear, with C 1/2 dependence for the diffusion coefficient and C 3/2 dependence for the refractive index. As a test of these effects on calculated mutual diffusion of electrolyte solutions at low concentrations as measured by Rayleigh interferometry, apparent mutual diffusion coefficients D v,a (volume-fixed reference frame) were measured for fixed average concentrations C=(0.02989 ± 0.00001) mol·dm –3 of Na 2 SO 4 (aq) at 298.15 K while varying ΔC/C from 0.66673 to 2, a threefold variation. The dependence of the diffusion coefficient on ΔC/C was found to be linear, yielding D v = 1.041 6 × 10 –9 m 2 ·s –1 for an infinitely small concentration difference between the diffusing solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolution of a Few Problems in the Application of Quasilinear Theory to Calculating Diffusion Coefficients in Heliophysics

A theory of quasilinear diffusion for obliquely propagating electromagnetic waves was developed in the 1960's and applied in the 1970's to model scattering of relativistic electrons by a prescribed distribution of waves. In the latter work, a transformation of variables, from wavevector space to the temporal frequency and tangent of the wave normal angle, was used so that simple Gaussian functions of frequency and tangent of the wave normal angle could be multiplied together to define the distribution of wave power, although arbitrary distributions of power in these two variables is also permitted. Finally, in 2005, previous work was consolidated and has been widely used in heliophysics studies that require computation of quasilinear diffusion coefficients. Here it is shown that this transformation is inppropriate when the precise wave vector distribution is known. The correct transformation is derived and used to produce diffusion coefficients that can differ by orders of magnitude from those computed using the inappropriate transformation. The differences are largest when the distribution of wave power extends to wave normal angles near the resonance cone. When the ratio of the plasma frequency to the gyrofrequency is large, only low energies (keV) are affected, but as the ratio decreases higher energies (MeV) also show differences. It is also shown that the derivation from the 1960's uses a notation that results in the diffusion coefficients depending on the distribution of wave power with respect to the wave azimuthal angle whereas there should be no such dependence.

79 ASTRONOMY AND ASTROPHYSICS↗

ANALYTIC FORMS OF THE PERPENDICULAR DIFFUSION COEFFICIENT IN NRMHD TURBULENCE

In the past different analytic limits for the perpendicular diffusion coefficient of energetic particles interacting with magnetic turbulence were discussed. These different limits or cases correspond to different transport modes describing how the particles are diffusing across the large-scale magnetic field. In the current paper we describe a new transport regime by considering the model of noisy reduced magnetohydrodynamic turbulence. We derive different analytic forms of the perpendicular diffusion coefficient, and while we do this, we focus on the aforementioned new transport mode. We show that for this turbulence model a small perpendicular diffusion coefficient can be obtained so that the latter diffusion coefficient is more than hundred times smaller than the parallel diffusion coefficient. This result is relevant to explain observations in the solar system where such small perpendicular diffusion coefficients have been reported.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Learning Predictions of Simulated Self-Diffusion Coefficients for Bulk and Confined Pure Liquids

Diffusion properties of bulk fluids have been predicted using empirical expressions and machine learning (ML) models, suggesting that predictions of diffusion also should be possible for fluids in confined environments. The ability to quickly and accurately predict diffusion in porous materials would enable new discoveries and spur development in relevant technologies such as separations, catalysis, batteries, and subsurface applications. Here in this work, we apply artificial neural network (ANN) models to predict the simulated self-diffusion coefficients of real liquids in both bulk and pore environments. The training data sets were generated from molecular dynamics (MD) simulations of Lennard-Jones particles representing a diverse set of 14 molecules ranging from ammonia to dodecane over a range of liquid pressures and temperatures. Planar, cylindrical, and hexagonal pore models consisted of walls composed of carbon atoms. Our simple model for these liquids was primarily used to generate ANN training data, but the simulated self-diffusion coefficients of bulk liquids show excellent agreement with experimental diffusion coefficients. ANN models based on simple descriptors accurately reproduced the MD diffusion data for both bulk and confined liquids, including the trend of increased mobility in large pores relative to the corresponding bulk liquid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating diffusion coefficients of shale oil, gas, and condensate with nano-confinement effect

Molecular diffusion plays an important role in oil and gas migration in tight shale formations. However, there are insufficient reference data in the literature to specify the diffusion coefficients within porous media. This study aims at calculating diffusion coefficients of shale gas, shale condensate, and shale oil at reservoir conditions with CO 2 injection for EOR/EGR. The large nano-confinement effects including large gas-oil capillary pressure and critical property shifts could alter the phase behaviors. This paper estimates the diffusivities of shale fluids in nanometer-scale shale rock from two perspectives: 1) examining the shift of diffusivity caused by nanopore confinement effects from phase change (phase composition and fluid property) perspective, and 2) calculating the effective diffusion coefficient in porous media by incorporating rock intrinsic properties (porosity and tortuosity factor). The tortuosity is obtained by using tortuosity-porosity relations as well as the measured tortuosity of shale from 3D imaging techniques. The results indicated that nano-confinement effects could affect the diffusion coefficient through altering the phase properties, such as phase compositions and densities. Compared to bulk phase diffusivity, the effective diffusion coefficient in porous shale rock is reduced by 10 2 to 10 4 times as porosity decreases from 0.1 to 0.03.

04 OIL SHALES AND TAR SANDS↗

Cross-correlation analysis of X-ray photon correlation spectroscopy to extract rotational diffusion coefficients

Coefficients for translational and rotational diffusion characterize the Brownian motion of particles. Emerging X-ray photon correlation spectroscopy (XPCS) experiments probe a broad range of length scales and time scales and are well-suited for investigation of Brownian motion. While methods for estimating the translational diffusion coefficients from XPCS are well-developed, there are no algorithms for measuring the rotational diffusion coefficients based on XPCS, even though the required raw data are accessible from such experiments. In this paper, we propose angular-temporal cross-correlation analysis of XPCS data and show that this information can be used to design a numerical algorithm (Multi-Tiered Estimation for Correlation Spectroscopy [MTECS]) for predicting the rotational diffusion coefficient utilizing the cross-correlation: This approach is applicable to other wavelengths beyond this regime. We verify the accuracy of this algorithmic approach across a range of simulated data.

97 MATHEMATICS AND COMPUTING↗

Banded structures in electron pitch angle diffusion coefficients from resonant wave-particle interactions

Electron pitch angle (D{sub αα}) and momentum (D{sub pp}) diffusion coefficients have been calculated due to resonant interactions with electrostatic electron cyclotron harmonic (ECH) and whistler mode chorus waves. Calculations have been performed at two spatial locations L = 4.6 and 6.8 for electron energies ≤10 keV. Landau (n = 0) resonance and cyclotron harmonic resonances n = ±1, ±2, … ±5 have been included in the calculations. It is found that diffusion coefficient versus pitch angle (α) profiles show large dips and oscillations or banded structures. The structures are more pronounced for ECH and lower band chorus (LBC) and particularly at location 4.6. Calculations of diffusion coefficients have also been performed for individual resonances. It is noticed that the main contribution of ECH waves in pitch angle diffusion coefficient is due to resonances n = +1 and n = +2. A major contribution to momentum diffusion coefficients appears from n = +2. However, the banded structures in D{sub αα} and D{sub pp} coefficients appear only in the profile of diffusion coefficients for n = +2. The contribution of other resonances to diffusion coefficients is found to be, in general, quite small or even negligible. For LBC and upper band chorus waves, the banded structures appear only in Landau resonance. The D{sub pp} diffusion coefficient for ECH waves is one to two orders smaller than D{sub αα} coefficients. For chorus waves, D{sub pp} coefficients are about an order of magnitude smaller than D{sub αα} coefficients for the case n ≠ 0. In case of Landau resonance, the values of D{sub pp} coefficient are generally larger than the values of D{sub αα} coefficients particularly at lower energies. As an aid to the interpretation of results, we have also determined the resonant frequencies. For ECH waves, resonant frequencies have been estimated for wave normal angle 89° and harmonic resonances n = +1, +2, and +3, whereas for whistler mode waves, the frequencies have been calculated for angle 10° and Landau resonance. Further, in ECH waves, the banded structures appear for electron energies ≥1 keV, and for whistler mode chorus waves, structures appear for energies >2 keV at L = 4.6 and above 200 eV for L = 6.8. The results obtained in the present work will be helpful in the study of diffusion curves and will have important consequences for diffuse aurora and pancake distributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The tracer diffusion coefficient of soft nanoparticles in a linear polymer matrix

The diffusion properties of nanoparticles in polymer nanocomposites are largely unknown and are often difficult to determine experimentally. To address this shortcoming, we have developed a novel method to determine the tracer diffusion coefficient of soft polystyrene nanoparticles in a linear polystyrene matrix. Monitoring the interdiffusion of soft nanoparticles into a linear polystyrene matrix provides the mutual diffusion coefficient of this system, from which the tracer diffusion coefficient of the soft nanoparticle can be determined using the slow mode theory. Utilizing this protocol, the role of nanoparticle molecular weight and rigidity on its tracer diffusion coefficient is provided. These results demonstrate that the diffusive behavior of these soft nanoparticles differ from that of star polymers, which is surprising since our recent studies suggest that the nanoparticle interacts with a linear polymer similarly to that of a star polymer. It appears that these deformable nanoparticles mostly closely mimic the diffusive behavior of fractal macromolecular architectures or microgels, where the transport of the nanoparticle relies on the cooperative motion of neighboring linear chains. Finally, the less cross-linked, and thus more deformable, nanoparticles diffuse faster than the more highly crosslinked nanoparticles, presumably because the increased deformability allows the nanoparticle to distort and fit into available space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The frequency-dependent response of single aerosol particles to vapour phase oscillations and its application in measuring diffusion coefficients

A new method for measuring diffusion in the condensed phase of single aerosol particles is proposed and demonstrated. The technique is based on the frequency-dependent response of a binary particle to oscillations in the vapour phase of one of its chemical components. Here, we discuss how this physical situation allows for what would typically be a non-linear boundary value problem to be approximately reduced to a linear boundary value problem. For the case of aqueous aerosol particles, we investigate the accuracy of the closed-form analytical solution to this linear problem through a comparison with the numerical solution of the full problem. Then, using experimentally measured whispering gallery modes to track the frequency-dependent response of aqueous particles to relative humidity oscillations, we determine diffusion coefficients as a function of water activity. The measured diffusion coefficients are compared to previously reported values found using the two common experiments: (i) the analysis of the sorption/desorption of water from a particle after a step-wise change to the surrounding relative humidity and (ii) the isotopic exchange of water between a particle and the vapour phase. The technique presented here has two main strengths: first, when compared to the sorption/desorption experiment, it does not require the numerical evaluation of a boundary value problem during the fitting process as a closed-form expression is available. Second, when compared to the isotope exchange experiment, it does not require the use of labeled molecules. Therefore, the frequency-dependent experiment retains the advantages of these two commonly used methods but does not suffer from their drawbacks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗