Quality Control of the Next-Generation Sequencing (NGS) Library through an Integrated Digital Microfluidic Platform.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as 'blobs.' Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly.
Monolayer transition metal dichalcogenides (TMDs) are a key class of two-dimensional (2D) materials with broad technological potential. Their Janus counterparts exhibit unique properties due to broken out-of-plane symmetry and further enrich the functionalities of TMDs. However, experimental synthesis and identification of Janus TMDs remain challenging. It is thus highly desirable to have a rapid, simple, and in situ characterization technique to monitor, in real time, the conversion process from the parent to Janus structure. Raman spectroscopy stands out for such a task as it is a powerful, nondestructive, and very commonly used tool to characterize 2D materials both in situ and ex situ. To realize the full potential of Raman spectroscopy on rapid characterization of Janus TMDs, we present a computational “Raman digital twin” library for various monolayer Janus TMDs in both 2H and Td phases. We focus on group-6 TMDs: MoS 2 , WS 2 , MoSe 2 , WSe 2 , MoTe 2 , WTe 2 and their Janus variants: MoSSe, MoSTe, MoSeTe, WSSe, WSTe, and WSeTe. Using first-principles density functional theory (DFT), we calculate their vibrational properties and predict distinct Raman fingerprints. These phonon and Raman signatures reflect each material’s structural symmetry and atomic composition, enabling clear identification via Raman spectroscopy. Our theoretical work supports experimental efforts by providing benchmarks for material identification, structural analysis, and quality control. In conclusion, the computational library expedites the discovery and development of Janus 2D materials, facilitating tighter integration between theoretical predictions and experimental validation.
Purpose: To evaluate uncertainties of organ specific Deformable Image Registration (DIR) for H and N cancer Adaptive Radiation Therapy (ART). Methods: A commercial DIR evaluation tool, which includes a digital phantom library of 8 patients, and the corresponding “Ground truth Deformable Vector Field” (GT-DVF), was used in the study. Each patient in the phantom library includes the GT-DVF created from a pair of CT images acquired prior to and at the end of the treatment course. Five DIR tools, including 2 commercial tools (CMT1, CMT2), 2 in-house (IH-FFD1, IH-FFD2), and a classic DEMON algorithms, were applied on the patient images. The resulting DVF was compared to the GT-DVF voxel by voxel. Organ specific DVF uncertainty was calculated for 10 ROIs: Whole Body, Brain, Brain Stem, Cord, Lips, Mandible, Parotid, Esophagus and Submandibular Gland. Registration error-volume histogram was constructed for comparison. Results: The uncertainty is relatively small for brain stem, cord and lips, while large in parotid and submandibular gland. CMT1 achieved best overall accuracy (on whole body, mean vector error of 8 patients: 0.98±0.29 mm). For brain, mandible, parotid right, parotid left and submandibular glad, the classic Demon algorithm got the lowest uncertainty (0.49±0.09, 0.51±0.16, 0.46±0.11, 0.50±0.11 and 0.69±0.47 mm respectively). For brain stem, cord and lips, the DVF from CMT1 has the best accuracy (0.28±0.07, 0.22±0.08 and 0.27±0.12 mm respectively). All algorithms have largest right parotid uncertainty on patient #7, which has image artifact caused by tooth implantation. Conclusion: Uncertainty of deformable CT image registration highly depends on the registration algorithm, and organ specific. Large uncertainty most likely appears at the location of soft-tissue organs far from the bony structures. Among all 5 DIR methods, the classic DEMON and CMT1 seem to be the best to limit the uncertainty within 2mm for all OARs. Partially supported by research grant from Elekta.
This paper introduces a novel and domain-independent method for automatically extracting keywords, as sequences of one or more words, from individual documents. We describe the method’s configuration parameters and algorithm, and present an evaluation on a benchmark corpus of technical abstracts. We also present a method for generating lists of stop words for specific corpora and domains, and evaluate its ability to improve keyword extraction on the benchmark corpus. Finally, we apply our method of automatic keyword extraction to a corpus of news articles and define metrics for characterizing the exclusivity, essentiality, and generality of extracted keywords within a corpus.
We report the development of an advanced high-throughput stress characterization method for thin film materials libraries sputter-deposited on micro-machined cantilever arrays consisting of around 1500 cantilevers on 4-inch silicon-on-insulator wafers. A low-cost custom-designed digital holographic microscope (DHM) is employed to simultaneously monitor the thin film thickness, the surface topography and the curvature of each of the cantilevers before and after deposition. The variation in stress state across the thin film materials library is then calculated by Stoney's equation based on the obtained radii of curvature of the cantilevers and film thicknesses. DHM with nanometer-scale out-of-plane resolution allows stress measurements in a wide range, at least from several MPa to several GPa. By using an automatic x-y translation stage, the local stresses within a 4-inch materials library are mapped with high accuracy within 10 min. The speed of measurement is greatly improved compared with the prior laser scanning approach that needs more than an hour of measuring time. A high-throughput stress measurement of an as-deposited Fe-Pd-W materials library was evaluated for demonstration. The fast characterization method is expected to accelerate the development of (functional) thin films, e.g., (magnetic) shape memory materials, whose functionality is greatly stress dependent.
Two primary goals of infrared spectroscopic dection are chemical identification and quantification. In order to accomplish these goals, a comprehensive and quantitative spectral library suitable for digital manipulation is required. To a large degree, the contents of such a library depend on the application. Since the primary application of the PNNL/DOE spectral library is for environmental monitoring, we have focused our efforts on hazardous pollutants, as well as a large variety of natural and anthropogenic chemicals. As a spin-off project and in collaboration with Dugway Proving Ground, we also had the opportunity to analyze a limited set of chemical warfare agents (CWAs).
This document pertains to the reporting requirements of DOE contract FE-0031767. The document covers the development of a model-based estimation (MBE) library for generating digital twins of coal-fired power plants (CFPPs). The models used by the MBE are transient and physics-based. Model classes in the library that correspond to different components in CFPPs are presented with physical explanations and representative results. MBE library provides Extended Kalman Filter (EKF), and Unscented Kalman Filter (UKF) algorithms. The MBE library is generic and can be used to represent a variety of CFPPs. A digital twin of a CFPP will be created as the reduced-order model of that CFPP is embedded in the developed MBE architecture.
Abstract not provided.
The well-known problem of reliability of partial photoneutron cross-section data obtained using beams of quasimonoenergetic annihilation photons was discussed. Noticeable disagreements between data from various experiments were analyzed using physical data reliability criteria. The experimentally-theoretical method for evaluating of reaction cross sections satisfied physical criteria was used and new reliable data were obtained for many nuclei. The disagreements between newly evaluated cross sections and data from the IAEA Digital Photonuclear Data Library were discussed.
Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.
Abstract not provided.
Twenty years have passed since first light for the Sloan Digital Sky Survey (SDSS). Here, we release data taken by the fourth phase of SDSS (SDSS-IV) across its first three years of operation (2014 July-2017 July). This is the third data release for SDSS-IV, and the 15th from SDSS (Data Release Fifteen; DR15). New data come from MaNGA—we release 4824 data cubes, as well as the first stellar spectra in the MaNGA Stellar Library (MaStar), the first set of survey-supported analysis products (e.g., stellar and gas kinematics, emission-line and other maps) from the MaNGA Data Analysis Pipeline, and a new data visualization and access tool we call "Marvin." The next data release, DR16, will include new data from both APOGEE-2 and eBOSS; those surveys release no new data here, but we document updates and corrections to their data processing pipelines. The release is cumulative; it also includes the most recent reductions and calibrations of all data taken by SDSS since first light. In this paper, we describe the location and format of the data and tools and cite technical references describing how it was obtained and processed. The SDSS website (www.sdss.org) has also been updated, providing links to data downloads, tutorials, and examples of data use. Although SDSS-IV will continue to collect astronomical data until 2020, and will be followed by SDSS-V (2020–2025), we end this paper by describing plans to ensure the sustainability of the SDSS data archive for many years beyond the collection of data.
Graphical Processing Units (GPUs) have recently become a valuable computing tool for the acquisition of data at high rates and for a relatively low cost. The devices work by parallelizing the code into thousands of threads, each executing a simple process, such as identifying pulses from a waveform digitizer. The CUDA programming library can be used to effectively write code to parallelize such tasks on Nvidia GPUs, providing a significant upgrade in performance over CPU based acquisition systems. The muon $g$-$2$ experiment at Fermilab is heavily relying on GPUs to process its data. The data acquisition system for this experiment must have the ability to create deadtime-free records from 700 $\mu$s muon spills at a raw data rate 18 GB per second. Data will be collected using 1296 channels of $\mu$TCA-based 800 MSPS, 12 bit waveform digitizers and processed in a layered array of networked commodity processors with 24 GPUs working in parallel to perform a fast recording of the muon decays during the spill. The described data acquisition system is currently being constructed, and will be fully operational before the start of the experiment in 2017.
This work details the development of a concentrating solar power (CSP) and thermal (CST) library archive. This work included digitization of one-of-a-kind documents that could be degraded or destroyed over time. Sandia National Laboratories (SNL) National Solar Thermal Test Facility (NSTTF) and Sandia's Technical Library departments collaborated to establish and maintain the first and only digital collection in the world of Concentrating Solar Power (CSP) related historical documents. These date back to the CSP program inception here at Sandia in the early 1970's thru to the present.
We present a 0.8-5 {mu}m spectral library of 210 cool stars observed at a resolving power of R {identical_to} {lambda}/{delta}{lambda} {approx} 2000 with the medium-resolution infrared spectrograph, SpeX, at the 3.0 m NASA Infrared Telescope Facility (IRTF) on Mauna Kea, Hawaii. The stars have well-established MK spectral classifications and are mostly restricted to near-solar metallicities. The sample not only contains the F, G, K, and M spectral types with luminosity classes between I and V, but also includes some AGB, carbon, and S stars. In contrast to some other spectral libraries, the continuum shape of the spectra is measured and preserved in the data reduction process. The spectra are absolutely flux calibrated using the Two Micron All Sky Survey photometry. Potential uses of the library include studying the physics of cool stars, classifying and studying embedded young clusters and optically obscured regions of the Galaxy, evolutionary population synthesis to study unresolved stellar populations in optically obscured regions of galaxies and synthetic photometry. The library is available in digital form from the IRTF Web site.
We have investigated the feasibilities and accuracies of the identifications of RR Lyrae stars and quasars from the simulated data of the Multi-channel Photometric Survey Telescope (Mephisto) W Survey. Based on the variable sources light curve libraries from the Sloan Digital Sky Survey (SDSS) Stripe 82 data and the observation history simulation from the Mephisto-W Survey Scheduler, we have simulated the uvgriz multi-band light curves of RR Lyrae stars, quasars and other variable sources for the first-year observation of Mephisto W Survey. We have applied the ensemble machine learning algorithm Random Forest Classifier (RFC) to identify RR Lyrae stars and quasars, respectively. We build training and test samples and extract ~150 features from the simulated light curves and train two RFCs respectively for the RR Lyrae star and quasar classification. We find that, our RFCs are able to select the RR Lyrae stars and quasars with remarkably high precision and completeness, with purity = 95.4% and completeness = 96.9% for the RR Lyrae RFC and purity = 91.4% and completeness = 90.2% for the quasar RFC. In conclusion, we have also derived relative importances of the extracted features utilized to classify RR Lyrae stars and quasars.
Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.