Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

33 records · Page 2

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Application of modern autoradiography to nuclear forensic analysis

Modern autoradiography techniques based on phosphorimaging technology using image plates (IPs) and digital scanning can identify heterogeneities in activity distributions and reveal material properties, serving to inform subsequent analyses. Here, we have adopted these advantages for applications in nuclear forensics, the technical analysis of radioactive or nuclear materials found outside of legal control to provide data related to provenance, production history, and trafficking route for the materials. IP autoradiography is a relatively simple, non-destructive method for sample characterization that records an image reflecting the relative intensity of alpha and beta emissions from a two-dimensional surface. Such data are complementary to information gathered from radiochemical characterization via bulk counting techniques, and can guide the application of other spatially resolved techniques such as scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS). IP autoradiography can image large 2-dimenstional areas (up to 20 × 40 cm), with relatively low detection limits for actinides and other radioactive nuclides, and sensitivity to a wide dynamic range (10 5 ) of activity density in a single image. Distributions of radioactivity in nuclear materials can be generated with a spatial resolution of approximately 50 μm using IP autoradiography and digital scanning. While the finest grain silver halide films still provide the best possible resolution (down to ~10 μm), IP autoradiography has distinct practical advantages such as shorter exposure times, no chemical post-processing, reusability, rapid plate scanning, and automated image digitization. Sample preparation requirements are minimal, and the analytical method does not consume or alter the sample. These advantages make IP autoradiography ideal for routine screening of nuclear materials, and for the identification of areas of interest for subsequent micro-characterization methods. Here in this article we present a summary of our setup, as modified for nuclear forensic sample analysis and related research, and provide examples of data from select samples from the nuclear fuel cycle and historical nuclear test debris.

07 ISOTOPE AND RADIATION SOURCES↗

SoK: What does it Mean to Benchmark Database Forensics?

Relational Database Management Systems are the backbone of modern enterprises and public-sector services, and are thus frequent targets of security incidents, insider threats, and thorough regulatory audits. Consequently, databases have become key sources of digital evidence, requiring investigators to reconstruct past activity from audit logs, transaction logs, and backups. Although benchmarking frameworks such as those developed by the Transaction Processing Performance Council (TPC) are widely used to evaluate database performance, they do not capture forensic requirements such as evidentiary completeness, tamper-evidence, chain of custody, or regulatory compliance under GDPR and CCPA. This survey examines the emerging domain of forensic database benchmarking. We gathered prior research on database forensics, secure logging, and tamper-evident data structures; we analyze modern forensic-ready features in commercial and open-source systems (SQL Server Ledger, Oracle Blockchain Tables, PostgreSQL pgAudit, Db2 Audit, Aurora Database Activity Streams, Oracle Real Application Security and IBM Guardium) and assess why existing benchmarks are insufficient. We propose forensic workloads, metrics, and methodologies that incorporate adversarial stressors, deleted-record recovery, and backup analysis. We also identify open research problems and call for a community-driven forensic benchmark suite. The result is an idea for evaluating not only database performance but also forensic soundness, bridging the gap between system engineering, compliance, and digital investigations.

Lenard, Ben↗

Digital Twins and Living Models at NASA

The idea of a “digital twin” was born at NASA in the 1960s as a “living model” of the Apollo mission. In response to Apollo 13’s oxygen tank explosion and subsequent damage to the main engine, NASA employed multiple simulators to evaluate the failure and extended a physical model of the vehicle to include digital components. This “digital twin” was the first of its kind, allowing for a continuous ingestion of data to model the events leading to up to the accident for forensic analysis and exploration of next steps. Fast forward half a century and NASA, along with others in the aerospace community, continues to develop and utilize high-fidelity digital models of physical systems and components as well as the extreme environments in which they operate. NASA aims to travel further and stay longer in space as we realize the Artemis program, taking us from the moon to Mars by establishing a sustainable presence on the Moon to prepare for missions to Mars. We will no longer be able to rely on constant connectivity with an asset nor be in-the-loop for on-demand human intervention in the event of an anomaly. Further, the importance of digital twins is increasing as we seek alternatives for certification of structures so large that they cannot be fully evaluated in existing test facilities and autonomous systems that are not deterministic. The idea of a digital twin is not a new one. What is new is the scale, ordinality, and non-deterministic nature of the models that are critical to achieving NASA’s goals. Their number and autonomy from each other as well as the reference system is suggestive of a changing ecosystem, returning us the idea of a living model.

Digital Twin↗

Categorizing An Explosive Device by its Nuclear Signature (Rev. 1)

This report documents a study to eliminate ambiguity in identifying a very low-yield nuclear detonation in the early stages of the response to such an event. The ambiguity arises from the very similar explosive and radiation effects produced by three categories of explosive devices: An explosively driven radiological dispersal device (RDD) or an accidental explosion in which radiologic material is scattered by chemical explosives. A failed nuclear device in which nuclear material, such as uranium or plutonium, has been scattered by conventional explosives. A nuclear device that, in addition to scattering nuclear material, produced a very low-yield from nuclear fission. The study found that the properties of fission products provide a ready solution to the problem. The radiation dose rate from fission products that were produced in a nearly instantaneous “fission event” decreases extremely rapidly over the first eight hours after that event, whereas nuclear materials and common radiological materials produce an essentially constant dose rate. This contrast provides an unequivocal fission product signature. The measurements required to utilize this signature can be made by first responders with radiation detectors already in the field, on time scales of an hour, although later confirmation using more capable detectors, including spectroscopic capability, is advised. The process of categorizing an explosives-related incident, both pre- and post-detonation, can be represented as a Decision Tree. The Decision Tree illustrates the use of already-fielded radiation detectors to categorize incidents as likely to involve only conventional explosives, an explosively driven RDD, or a nuclear device. The identification of an explosion as a fission event is extremely important to evacuation planners. It has been shown that delayed evacuation after sheltering in place for up to 24 hours after a fission event has the potential to reduce radiation exposure to the affected public and responders by a factor of ten. Traditional evidence collection after a nuclear detonation is likely to be similarly delayed, as the value and urgency of collection efforts must be weighed against radiation and other hazardous exposure of the collectors. The evidence that survives the immediate effects of a nuclear detonation will, in many cases, still be available for collection once radiation levels have diminished to acceptable levels. Certain classes of evidence, notably information stored on digital media, may significantly degrade from exposure to post-detonation radiation fields. Technical nuclear forensics collections will be performed in all events with nuclear yield. Modification of the high-yield collection strategy may be necessary for a very low-yield device.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Morphology and particle size (MaPS) exercise: testing the applications of image analysis and morphology descriptions for nuclear forensics

Image analysis techniques have been applied and shown to be a valuable tool in nuclear forensics analysis. The interlaboratory exercise reported here has tested quantitative and qualitative approaches for characterizing nuclear materials. Particle size, surface features and morphology descriptions were compared by four laboratories on a common image set generated by Scanning Electron Microscopy and Digital Light Microscopy. Quantitative analysis of the image sets through the Morphological Analysis for MAterials software highlighted the strength of image analysis, but also that the application of the software alone can introduce significant bias in the analysis. Qualitative morphology descriptions following the process outlined by Tamasi et al. (J Radioanal Nuclear Chem 307:1611–1619, 2015) were compared with a discussion on the robustness and reproducibility of the results. Finally, future work should continue to focus on proficiency and standardization of image analysis through continued exercises within the extended nuclear forensics community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photogrammetry Tool for Forensic Analysis

A system allows crime scene and accident scene investigators the ability to acquire visual scene data using cameras for processing at a later time. This system uses a COTS digital camera, a photogrammetry calibration cube, and 3D photogrammetry processing software. In a previous instrument developed by NASA, the laser scaling device made use of parallel laser beams to provide a photogrammetry solution in 2D. This device and associated software work well under certain conditions. In order to make use of a full 3D photogrammetry system, a different approach was needed. When using multiple cubes, whose locations relative to each other are unknown, a procedure that would merge the data from each cube would be as follows: 1. One marks a reference point on cube 1, then marks points on cube 2 as unknowns. This locates cube 2 in cube 1 s coordinate system. 2. One marks reference points on cube 2, then marks points on cube 1 as unknowns. This locates cube 1 in cube 2 s coordinate system. 3. This procedure is continued for all combinations of cubes. 4. The coordinate of all of the found coordinate systems is then merged into a single global coordinate system. In order to achieve maximum accuracy, measurements are done in one of two ways, depending on scale: when measuring the size of objects, the coordinate system corresponding to the nearest cube is used, or when measuring the location of objects relative to a global coordinate system, a merged coordinate system is used. Presently, traffic accident analysis is time-consuming and not very accurate. Using cubes with differential GPS would give absolute positions of cubes in the accident area, so that individual cubes would provide local photogrammetry calibration to objects near a cube.

Lane, John↗

Uncertainty in the use of MAMA software to measure particle morphological parameters from SEM images

The MAMA software package developed at LANL is designed to make morphological measurements on a wide variety of digital images of objects. At LANL, we have focused on using MAMA to measure scanning electron microscope (SEM) images of particles, as this is a critical part of our forensic analysis of interdicted radiologic materials. In order to successfully use MAMA to make such measurements, we must understand the level of uncertainty involved in the process, so that we can rigorously support our quantitative conclusions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Better Pictures in a Snap

Retinex Imaging Processing, winner of NASA's 1999 Space Act Award, is commercially available through TruView Imaging Company. With this technology, amateur photographers use their personal computers to improve the brightness, scene contrast, detail, and overall sharpness of images with increased ease. The process was originally developed for remote sensing of the Earth by researchers at Langley Research Center and Science and Technology Corporation (STC). It automatically enhances a digital image in terms of dynamic range compression, color independence from the spectral distribution of the scene illuminant, and color/lightness rendition. As a result, the enhanced digital image is much closer to the scene perceived by the human visual system, under all kinds and levels of lighting variations. TruView believes there are other applications for the software in medical imaging, forensics, security, recognizance, mining, assembly, and other industrial areas.

Source record↗

Multispectral Gamma-Ray Analysis Using Clover Detectors with Application to Uranium Fission Product Analysis

A high-efficiency gamma-ray counting system has been built at Los Alamos National Laboratory for use in analyzing nuclear forensics samples. This system consists of two clover high-purity germanium detectors and is surrounded by a thallium-doped sodium iodide annulus. Special precautions have been taken to ensure the system has a low background. The system is connected to XIA Pixie-4 fast digitizers and collects data in list-mode. This work is split into two main parts. The first part describes the proper steps and techniques to initialize the settings of a detector system connected to fast digitizers in order to optimize the system for resolution and throughput. The various counting modes for this particular system are described in detail, including the benefits and drawbacks of each mode. Steps are then shown to characterize the system by obtaining efficiency curves for various counting modes and sample geometries. Because of the close counting geometry involved with this system, true coincidence summing factors must be calculated, and are done so in part by measuring the peak-to-total ratios of the system in its various counting modes across a wide energy range. The dead-time for the system can be complicated due to the multiple inputs of the system. Techniques for calculating the dead-time of multiple-detector systems are discussed. The second part of this work shows the system’s usefulness in analyzing nuclear forensics samples, specifically irradiated enriched uranium. Three fission product parent-daughter pairs of different lifetimes are analyzed over a course of six months. The activities of each nuclide are calculated at each time step. Age dating techniques using the parent-daughter pairs are discussed, as well as the detection limits of each nuclide for a range of sample ages. Finally, avenues for further research are presented, as well as potential sources of error or uncertainty for this work.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Use of Compton suppression gamma ray spectrometry to determine 239 Pu

We report 239 Pu has been characterized by gamma-ray spectroscopy for a level higher than the usual environmental ones typically needing alpha spectrometry, ICP-MS or TIMS. The higher activities typically have applications in reprocessing, safeguards verification, and nuclear forensics. For activities of hundreds of Bq/g, it is possible to use gamma ray spectrometry for 239 Pu characterization. A soil reference standard of 185 Bq/g (75 ng/g) was measured on a 79% efficient HPGe with a digital Compton suppression system. The ratios of the counting statistics for suppressed and unsuppressed uncertainties for various 239 Pu photopeaks were determined. The effects of self-attenuation on the low energy gamma rays were evaluated, and it was determined that Compton suppression was an effective characterization method of 239 Pu after accounting for self-attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Document-Based Nuclear Archaeology

Deeper reductions in the nuclear arsenals will require better understanding of historic fissile material management and production. The concept of “nuclear archaeology” has been considered since the 1990s to provide the tools and methods to develop independent production estimates, primarily based on nuclear forensic techniques. Here, we propose to add a framework for reconstructing the history of a nuclear program that complements traditional nuclear archaeology techniques by examining the role of operating records to support such an effort. As a test case, we use the JEEP II reactor, a 2 MW civilian research reactor at Norway’s Institute for Energy Technology (IFE), in operation for more than fifty years, however, recently shut down permanently. We have collected, analyzed, and started to preserve the reactor’s operating records, which exist on both analog and digital media, and to simulate parts of its history using OpenMC/ONIX neutronics calculations. Here, a particular focus of this project has been on digital data curation and preservation to confirm and maintain the integrity, authenticity, and provenance of these records. In developing guidelines for best practices that conform to existing standards for long-term digital preservation and curation, we hope this project can help lay the basis for future nuclear archaeology efforts to support nuclear arms control and disarmament.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nondestructive Testing As a Tool in the Space Shuttle Columbia Accident Investigation

Nondestructive testing (NDT) played a crucial role in determining the Columbia tragedy's cause. Over 84,000 pieces of debris were recovered; hundreds were subsequently subjected to NDT and materials analysis. Visual NDT of the debris revealed localized areas of damage such as erosion, excessive heating, knife edging and mechanical damage. Three-dimensional reconstructions were made of the left wing leading edge, utilizing a tripod-mounted laser scanning head and focused laser beam, and an advanced topometric optical scanner (ATOS) with digital white light to scan complex-shaped debris, producing monochrome 3-D models. Texture mapping provided a means to capture true colors of the debris and superimpose them on the scanned images. Uniform deposits were found over large portions of debris, obscuring underlying materials. To determine what was beneath, inverse radiography was enlisted. The radiographs guided investigators to where samples should be taken. To ascertain compositions, these samples were subjected to analytical testing, including energy dispersive X-ray spectroscopy and electron microprobe analysis. This combination of visual evidence, radiography, virtual reconstruction, and materials analysis allowed the forensic scientists to verify that a breach occurred in the leading edge of the left wing, the path the plasma followed, and the sequence of events that led to the loss.

McDanels, Steve↗

3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events

An analytical, advanced imaging method has been developed for the initial monitoring and identification of foam debris and similar anomalies that occur post-launch in reference to the space shuttle s external tank (ET). Remote sensing technologies have been used to perform image enhancement and analysis on high-resolution, true-color images collected with the DCS 760 Kodak digital camera located in the right umbilical well of the space shuttle. Improvements to the camera, using filters, have added sharpness/definition to the image sets; however, image review/analysis of the ET has been limited by the fact that the images acquired by umbilical cameras during launch are two-dimensional, and are usually nonreferenceable between frames due to rotation translation of the ET as it falls away from the space shuttle. Use of stereo pairs of these images can enable strong visual indicators that can immediately portray depth perception of damaged areas or movement of fragments between frames is not perceivable in two-dimensional images. A stereoscopic image visualization system has been developed to allow 3D depth perception of stereo-aligned image pairs taken from in-flight umbilical and handheld digital shuttle cameras. This new system has been developed to augment and optimize existing 2D monitoring capabilities. Using this system, candidate sequential image pairs are identified for transformation into stereo viewing pairs. Image orientation is corrected using control points (similar points) between frames to place the two images in proper X-Y viewing perspective. The images are then imported into the WallView stereo viewing software package. The collected control points are used to generate a transformation equation that is used to re-project one image and effectively co-register it to the other image. The co-registered, oriented image pairs are imported into a WallView image set and are used as a 3D stereo analysis slide show. Multiple sequential image pairs can be used to allow forensic review of temporal phenomena between pairs. The observer, while wearing linear polarized glasses, is able to review image pairs in passive 3D stereo.

Brown, Richard↗

Digital droplet multiple displacement amplification (ddMDA) for whole genome sequencing of limited DNA samples

Here, multiple displacement amplification (MDA) is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples) before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA) technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently, the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet), ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli) compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.

59 BASIC BIOLOGICAL SCIENCES↗