Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct Current (DC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Printed circuit board for integrated LED driver

A light emitting diode (LED) module may include a direct current (DC) voltage node formed on a first layer. The DC voltage node may be configured to sink a first current. One or more devices may be formed on the first layer configured to provide a second current to one or more LEDs. A device of the one or more devices may carry a steep slope voltage waveform. A local shielding area may be formed in a second layer directly below the DC voltage node and the one or more devices. The local shielding area may include a substantially continuous area of conductive material. A conductive via may extend through one or more layers. The conductive via may electrically connect the DC voltage node and the local shielding area.

Song, Zhihua↗

Enhancing Surface Finish of Additively Manufactured 316L Stainless Steel with Pulse/Pulse Reverse Electropolishing

To improve the reliable integration of additively manufactured (AM) metal components, there is an urgent need for surface finishing methods capable of processing rough, “as-printed” surfaces. Here, we present a new and scalable electropolishing (EP) technique for use on AM 316L stainless steel (SS) that is capable of achieving a surface roughness equivalent to a machined finish, with arithmetic mean heights (S a ) as low as 1.0 µm. This technique utilizes the sequential application of a new, NaCl/H 2 O pulse/pulse reverse (P/PR) EP step along with a conventional DC (direct current) EP step, where P/PR expands the capability of EP by removing roughness features > 1 µm, which has been previously unattainable with DC EP alone without substantial material removal. This is achieved by independently varying pulse parameters, such as pulse width and height, allowing more control over electrodynamic processes at the part-electrolyte interface. Additionally, P/PR EP resulted in higher smoothing efficiency, where a higher degree of smoothing was achieved with less material removal when compared with conventional DC EP alone. This minimizes unwanted change in geometry from excessive metal dissolution.

36 MATERIALS SCIENCE↗

Enabling AC electroluminescence in quasi-2D perovskites by uniformly arranging different-n-value nanoplates to allow bidirectional charge transport

Perovskite light-emitting diodes (LEDs) are normally operated under forward direct current (DC) to realize electron/hole injection at cathode/anode surfaces. In this work, we demonstrate an alternating current (AC) driven LED enabled by bi-directionally allowed charge transport in quasi-2D perovskite (PEA 2 MA n-1 PbnI 3n+1 ) film. Essentially, the bi-directional charge transport is realized by uniformly arranging different-n-value 2D nanoplates together with symmetrically designed anode/cathode interfaces, which can allow injected electrons and holes to form light-emitting states under both forward and reverse biases, leading to an AC electroluminescence (EL) with the device architecture of ITO/PEI/PEDOT:PSS/PEA 2 MA n-1 PbnI 3n+1 /P3HT/PEI/Ag. The high AC EL performance was achieved with the radiance = 24 W Sr -1 m -2 and 18.3 W Sr -1 m -2 and EQE = 12.5% and 3.7% under forward and reverse biases. Furthermore, the device-operational stability was largely improved with the half-intensity time of T 50 = 11.0 h under AC bias (+2 V/-2 V, 50 Hz) as compared to T 50 = 3.9 h under forward bias (+2 V/0 V, 50 Hz).

36 MATERIALS SCIENCE↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Advanced spectroscopic studies of (PPh 4 ) 2 [Co(N 3 ) 4 ], a field-induced single-ion magnet

The high-spin Co II complex (PPh 4 ) 2 [Co(N 3 ) 4 ] (Co-N 3 )has been investigated using advanced spectroscopic techniques [far-IR magneto-spectroscopy (FIRMS), high-frequency and high-field EPR (HFEPR), and inelastic neutron scattering (INS)] to study its zero-field-splitting (ZFS), giving spin-Hamiltonian (SH) parameters. The analysis of multi-frequency HFEPR reveals the easy-axis anisotropy with a D value of −10.39(5) cm −1 and a rhombic ratio (E/D) of 0.21(1). The magnetic properties have also been probed by direct-current (DC) magnetometry, suggesting minor differences in anisotropy from the previously reported polymorph (Co-N 3 ′). Ligand-field theory (LFT) analysis indicates that the structures of Co-N 3 and Co-N 3 ′ are closer to D 2d symmetry than other symmetries considered. Alternate-current (AC) susceptibility reveals slow magnetic relaxation under an applied field, indicating that Co-N 3 is a field-induced single-ion magnet (SIM). Here, while both Co-N 3 and Co-N 3 ′ were studied by DC magnetometry, one unusual aspect of the current work on Co-N 3 is that advanced spectroscopies HFEPR, FIRMS, and INS were used to directly observe transitions between ZFS split states, giving accurate SH parameters.

Hand, Adam T. [Univ. of Tennessee, Knoxville, TN (↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Optimal Operation of PV Sources in DC Grids for Improving Technical, Economical, and Environmental Conditions by Using Vortex Search Algorithm and a Matrix Hourly Power Flow

This document presents a master–slave methodology for solving the problem of optimal operation of photovoltaic (PV) distributed generators (DGs) in direct current (DC) networks. This problem was modeled using a nonlinear programming model (NLP) that considers the minimization of three different objective functions in a daily operation of the system. The first one corresponds to the minimization of the total operational cost of the system, including the energy purchasing cost to the conventional generators and maintenance costs of the PV sources; the second objective function corresponds to the reduction of the energy losses associated with the transport of energy in the network, and the third objective function is related to the minimization of the total emissions of CO2 by the conventional generators installed on the DC grid. The minimization of these objective functions is achieved by using a master–slave optimization approach through the application of the Vortex Search algorithm combined with a matrix hourly power flow. To evaluate the effectiveness and robustness of the proposed approach, two test scenarios were used, which correspond to a grid-connected and a standalone network located in two different regions of Colombia. The grid-connected system emulates the behavior of the solar resource and power demand of the city of Medellín-Antioquia, and the standalone network corresponds to an adaptation of the generation and demand curves for the municipality of Capurganá-Choco. A numerical comparison was performed with four optimization methodologies reported in the literature: particle swarm optimization, multiverse optimizer, crow search algorithm, and salp swarm algorithm. The results obtained demonstrate that the proposed optimization approach achieved excellent solutions in terms of response quality, repeatability, and processing times.

14 SOLAR ENERGY↗

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient, Rural, and Revolutionary: Salisbury Square's Direct-Current Affordable Microgrid Community: Preprint

The technology to interconnect buildings with a dedicated direct-current (DC) power distribution network is in place today; what is missing is a turnkey approach to designing a DC microgrid - and the business models allowing such systems to be deployed, owned, and operated at scale. To close this gap, the Salisbury Square Development Team, comprising clean-energy experts, has engineered a resilient community DC microgrid for an affordable housing community in Randolph, Vermont. Ten single-family, occupant-owned residences and 12 multifamily rental units will share locally generated and stored solar energy via a DC power distribution bus capable of operating during extended grid outages. With a DC power distribution network in place, each home will be equipped with high-efficiency DC lighting and appliances, operating alongside alternating current (AC) appliances, even during an islanded mode of operation. To obtain a comprehensive understanding of what is possible and achievable, the Team collaborated with the local utility, regulatory agencies, a national laboratory, energy-as-service providers, and vendors. The collaborators evaluated microgrid typologies, business models, and energy modeling, and analyzed electrification and resilience. Further, the Team applied the URBANoptTM (Urban Renewable Building and Neighborhood optimization, NREL 2022) software development kit (SDK) to Salisbury Square's single-family and multifamily buildings to validate workflows and identify needs for advanced capability. This paper addresses the barriers to entry, scalability, and impact on residents and system ownership. It also examines the analysis that informed the design and engineering of the DC microgrid and the opportunities to streamline the process.

DER↗

Orientation-Dependent Distortion of Lamellae in a Block Copolymer Electrolyte under DC Polarization

Lithium-salt-doped block copolymers have the potential to serve as solid electrolytes in rechargeable batteries with lithium metal anodes. In this work, we use small-angle X-ray scattering (SAXS) to study the structure of polystyrene-block-poly(ethylene oxide) (PS-b-PEO) doped with bis-(trifluoromethylsulfonyl)amine lithium salt (LiTFSI) during direct current (dc) polarization experiments in lithiu-lithium symmetric cells. The block copolymer studied is nearly symmetric in composition, has a total molecular weight of 39 kg mol -1 , and exhibits a lamellar morphology at all studied salt concentrations. When ionic current is passed through the electrolyte, a salt concentration gradient forms that induces a spatial gradient in the domain spacing, d. The dependence of d on distance from the positive electrode, x, was determined experimentally by scanning the incident X-ray beam from one lithium electrode to the other. By studying the two-dimensional (2D) SAXS patterns as a function of azimuthal scattering angle, we find that lamellae with PS/PEO interfaces oriented perpendicular to the flow of ionic current (LAM ⟂ ) swell and contract to a greater degree than those with interfaces oriented parallel to the current direction (LAM || ). While domains with the LAM ⟂ do not provide direct conducting pathways between the electrodes, our analysis suggests that they play an important role in establishing the salt concentration gradient necessary for sustaining a large ionic current through greater expansion and contraction.

25 ENERGY STORAGE↗

Navigating the Use of Direct Current in Residential Settings: Merits and Obstacles

This review paper provides an in-depth analysis of the role of Direct Current (DC) power systems in residential settings, focusing on their safety, efficiency, and environmental advantages. It recognizes the significant contribution of the residential sector to global carbon dioxide emissions and explores how DC power systems can help mitigate these effects. The paper traces the historical evolution of DC power, its resurgence with renewable energy technologies, and the advancements in power electronics that facilitate its integration. Emphasizing the efficiency and safety benefits, especially in low-voltage applications, the paper highlights the seamless integration of DC systems with inherently DC-generating renewable sources like solar PV and wind. The review discusses the critical role of converter technologies in the transition to DC power and examines the compatibility of DC systems with energy storage solutions, underscoring their potential for enhanced energy management. It also addresses the environmental impacts of adopting DC power, aligning with global carbon reduction efforts. The paper analyzes regional case studies, exploring practical applications and outcomes, and addresses challenges such as the need for standardization. It concludes with recommendations for stakeholders and future research directions, emphasizing the economic, technological, and environmental aspects of DC power systems. Overall, the paper presents DC power as a viable and sustainable option for residential energy conservation, contingent upon ongoing technological progress, supportive policies, and standardization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Candidate spin-liquid ground state in CsNdSe 2 with an effective spin-1/2 triangular lattice

Rare-earth-based triangular lattice materials are extremely attractive for studying unconventional magnetism. Here, we report the magnetic properties of layered CsNdSe 2 based on direct current (DC) and alternating current (AC) susceptibility measurements down to 0.04 K. While the AC susceptibility at the zero DC field shows a broad hump below 0.5 K, there is no sign of any long-range magnetic ordering. Quantitative analysis of the DC magnetic susceptibility gives the negative Curie-Weiss (CW) temperature θ CW < 0 in all directions, indicating antiferromagnetic interaction between Nd ions. Of particular interest is the low temperature magnetic susceptibility, which reflects the effective spin-1/2 state with $\theta^a_{\text {cw}}/\theta^c_{\text {cw}}$ > 3. The estimated exchange interactions are J a /k B = 1.42 K (in-plane) and J c /k B = 0.44 K (out-of-plane), pointing to the anisotropic magnetism. First-principles calculations that include spin-orbit coupling and Coulomb correlations reveal multiple states with zero net magnetization for CsNdSe 2 . Both experiment and simulation strongly suggest CsNdSe 2 has the spin liquid ground state with effective spin-1/2. Application of a magnetic field can induce long-range antiferromagnetic ordering with the maximum transition temperature around 0.3 K, in further support of the zero-field spin liquid state.

36 MATERIALS SCIENCE↗

A New Capability of E4D For 3D Parallel Joint Inversion of DC Resistivity And Traveltime Data on Unstructured Mesh

A major challenge in interpreting geophysical data is how to derive consistent three-dimensional (3D) earth models of different physical properties from spatially and temporally limited measurements. Joint inversion with cross-gradient constraints is an approach to find such models by imposing structural similarities between different physical parameters. We have developed a parallel distributed-memory joint inversion code for direct-current (DC) resistivity and traveltime data using the cross-gradient constraint on unstructured mesh. The code utilizes existing E4D framework for parallel forward simulation, distributed storage and computation of the Jacobian matrix of forward operator, and parallel execution of matrix-vector multiplication during inversion. Besides, the joint inversion is solved by nonlinear conjugate gradient algorithm parallelized for DC resistivity and traveltime data. The joint inversion capability of E4D was tested using synthetic data from cross-borehole DC resistivity and traveltime data. The results indicate that the shape and size of the anomalies from the joint inversion are more reliable than those from separate inversions.

58 GEOSCIENCES↗

Mitigating dust particle contamination in an afterglow plasma by controlled lifting with a DC electric field

Abstract Particle contamination due to plasma processing motivates the design of a method of electrically lifting particles in a time interval after a plasma’s power is turned off. Small solid dust particles have electric charges that are not frozen until a late stage of the plasma afterglow. Beyond that time, before they fall to a surface below and cause defects, particles can be lifted in a controlled manner by applying an appropriate direct-current (DC) electric field, as we demonstrate experimentally. A few milliseconds after an argon plasma’s capacitively coupled radio-frequency power is switched off, a vertical DC electric field is applied. Thereafter, video imaging shows that the falling of the particles is slowed or stopped altogether, depending on the magnitude of the upward electric force.

Physics↗

Determining Proton Transport in Pseudo Catalyst Layers Using Hydrogen Pump DC and AC Techniques

Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.

25 ENERGY STORAGE↗

A statistical approach to analyzing domain dynamics in ferroelectric crystals using X-ray photon correlation spectroscopy

Ferroelectric materials exhibit strong electromechanical coupling, largely influenced by their domain structures. Numerous microstructural studies indicate that smaller domains with higher domain wall density generally enhance domain wall motion, although some inconsistencies have been reported. In this work, we use X-ray photon correlation spectroscopy (XPCS) to probe dynamic response in Pb(Mg 1/3 Nb 2/3 )O 3 -29PbTiO 3 (PMN-29PT) single crystals under applied electric fields. We introduce a two-field correlation approach, adapted from conventional two-time correlation to quantify dynamics. Statistical analysis reveals that both [001]-oriented direct current (DC) and alternating current (AC) poled samples show Poisson-like behavior within specific electric field regions. The DC-poled samples exhibit more frequent domain wall jump events but with smaller amount of decorrelation per jump event, whereas the AC-poled samples show fewer jump events with larger decorrelation per jump event. This observation aligns with the prevalence of 109° domain walls in the AC-poled samples, which contribute to more domain wall motion. These findings provide experimental evidence of collective domain wall motion and establish a direct connection between mesoscale dynamics and electromechanical response.

36 MATERIALS SCIENCE↗