Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct current fast charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

DC Fast Charger Usage in the Pacific Northwest

This document will describe the use of a number of Direct Current Fast Charging Stations throughout Washington and Oregon as a part of of the West Coast Electric Highway. It will detail the usage frequency and location of the charging stations INL has data from. It will also include aggregated data from hundreds of privately owned vehicles that were enrolled in the EV Project regarding driving distance when using one of the West Coast Electric Highway fast chargers. This document is a white paper that will be published on the INL AVTA website.

33 ADVANCED PROPULSION SYSTEMS↗

DCFC + Hydrogen Station Design Optimization [Slides]

Both direct current fast charging (DCFC) and Hydrogen stations are working to create successful long-term business models; however, analyses for DCFC and hydrogen fueling infrastructure are almost always performed separately. This work provides a detailed exploration of the benefit of integrating DCFC and hydrogen stations to lower the total system cost from load balancing and equipment cost sharing. To achieve this we have adapted the REopt optimization framework to simultaneously optimize the design and operation of integrated DCFC and H2 fueling station. Results indicate that 1) combining hydrogen fueling and DCFC stations can significantly reduce lifetime costs compared to separated stations. 2) Co-location with additional site load reduces DCFC costs, however, integration of DCFC with hydrogen provides an even greater cost reduction. 3) Adding PV to combined stations further reduces the lifetime station cost. 4) Capital investments in station combination today can help reduce the cost of operating DCFC tomorrow and 5) product diversification acts as a hedge against variability and enables a more dynamic response to market changes.

08 HYDROGEN↗

I-80 Mid-America Clean Fuels Corridor: Deployment Plan Report

The I-80 Mid-America Clean Fuels Corridor, which spans I-80 from Fort Lee, New Jersey, to Council Bluffs, Iowa, was designated an Alternative Fuels Corridor (AFC) in Round 1 of the Alternative Fuels Corridor program administered by the U.S. Department of Transportation’s (DOT’s) Federal Highway Administration (FHWA). Originally called the “I-80 Mid-America Alternative Fuels Corridor,” it is now named the “I-80 Mid-America Clean Fuels Corridor.” As of Round 6 AFC designation, parts of the corridor have sufficient direct current fast charging (DCFC) stations to be designated Electric Vehicle (EV)-Ready and sufficient compressed natural gas (CNG) fueling stations to be designated CNG-Ready. However, much of the corridor’s approximately 1,240 miles (mi) are not yet EV- or CNG-Ready. This includes about 1,130 mi that are designated EV-Pending and 700 mi that are designated CNG-Pending. This report presents a plan to develop EV charging and CNG fueling infrastructure sufficient to convert the entire length of the corridor to EV-Ready and CNG-Ready. Specific sites are not identified for future infrastructure. Rather, priority exits are identified, and information, analysis, and additional steps are recommended to support further refinement of these locations, as well as additional outreach and deployment efforts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Enabling fast charging – Vehicle considerations

To achieve a successful increase in the plug-in battery electric vehicle (BEV) market it is anticipated that a significant improvement in battery performance is required to improve the range that BEVs can travel. While the range that BEVs can travel on a single recharge is improving, the rate at which these vehicles can be recharged is still much slower than conventional internal combustion engine vehicles. To achieve comparable recharge times we explore the vehicle considerations of charge rates up to 350 kW. This faster recharge is expected to significantly mitigate the perceived deficiencies for long-distance transportation, to provide alternative charging in densely populated areas where overnight charging at home may not be possible, and to reduce range anxiety for travel within a city when unplanned charging maybe required. This substantial increase in the charging rate is expected to create technical issues in the design of the battery system and the vehicle electrical architecture that must be resolved. This work will focus on the battery system thermal design and total recharge time to meet the goals of implementing higher charge rates as well as the impacts of the expected increase in system voltage on the components of the vehicle.

25 ENERGY STORAGE↗

Considerations for Corridor and Community DC Fast Charging Complex System Design

The Idaho National Laboratory (INL), a U.S. Department of Energy (DOE) national laboratory located in Idaho Falls, Idaho, has been DOE’s lead laboratory for the field testing of light-duty plug-in electric vehicles (PEVs), charging infrastructure, and other alternative vehicle technologies for 25 years. INL has tested and collected data from more than 17,000 charging stations, documenting efficiencies, charge profiles, and PEV drivers’ behaviors when using charging infrastructure. Based on the experience of INL staff and support personnel, DOE requested that INL perform three tasks: • Identify pertinent lessons learned from previous direct current (DC) fast charger (DCFC) deployment and data collection activities in order to perform an analysis of the experience to date with DC fast charging systems • Establish the criteria for siting DC fast charging systems, including access to current or future sizeable penetrations of PEVs and existing power, the potential to be used by local (intracity) as well as pass-through (intercity) PEV drivers, expandability, and accessible to the federal highway system • Develop a draft system specification that lists the components that will be incorporated in a DC fast charging complexes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electricity Cost for Electric Vehicle Fast Charging

As the adoption of plug-in electric vehicles (PEVs) continues to grow, so does the development of a network of fast-charging stations to support long-distance travel and provide alternatives to residential and workplace charging. Fast charging, however, could be significantly more expensive than residential/workplace charging, mainly due to high power consumption and low utilization. This poster highlights NREL's review of the current cost of electricity for PEV fast charging in the United States as well as its evaluation of alternative charting options to mitigate electricity costs for public fast-charging stations via on-site electricity generation (from photovoltaics) and storage.

25 ENERGY STORAGE↗

Empirical analysis of electric vehicle fast charging under cold temperatures

This paper presents an empirical analysis of the effects of temperature on Direct Current Fast Charger (DCFC) charging rate and discusses the impact of such effects on wider adoptions of electric vehicles (EVs). The authors conducted statistical analysis on the effects of temperature and constructed an electric vehicle charging model that can show the dynamics of DCFC charging process under different temperatures. The results indicate that DCFC charging rate can deteriorate considerably in cold temperatures. These findings may be used as a reference to identify and assess the regions that may suffer from slow charging. In conclusion, the problems associated with temperature effects on DCFC charging deserve greater attention as electrification of motor vehicles progresses and DCFC usage increases in the future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enabling Fast Charging: A Technology Gap Assessment

The transportation sector accounts for the largest percentage of energy use in the United States. Decreasing energy consumption across this sector, especially in commercial light duty transportation, is essential for the U.S. to gain energy independence. Recently, powertrain electrification with plug-in electric vehicles (PEVs) have gained traction as an alternative due to their inherent efficiency advantages compared to the traditional internal combustion engine vehicle (ICEV). Accounting for 500,000 vehicle on the road today, these PEVs will reduce oil imported into the U.S. by five billion gallons and save two billion dollars in fuel costs to consumers over their useful life. Though there are many different classes of PEV, the intent of this study is to focus on non-hybrid powertrains, or battery electric vehicles (BEVs). Despite rapid drops in cost within the BEV powertrain of over 4x in the last 10 years, the PEV market still only accounts for approximately 1% of new light duty vehicle sales annually. Though BEV powertrain costs are not quite at parity with the ICEV, another gap to wider adoption of BEVs that have been identified is the ability to refuel quickly, or to fast charge. Though the majority of recharging BEVs is done at home, having access to fast charge stations has a big impact on BEV utility from a consumer perspective. To address the fast charge barrier, charging at 350 kW, or extreme fast charging (XFC), has been proposed and will serve as the basis for discussion in this report. Studies have shown that in areas where drivers have access to 50 kW or 120 kW fast charge stations, annual electric vehicle miles traveled (eVMT) increased by over 25%, even in cases where fast charging was used for 1-5% of total charging events [1, 2]. Having access to these fast charge stations can help alleviate the “range anxiety” that is cited as a common reason for consumers to hesitate to buy a BEV. Though, to be truly competitive to the ICEV refueling experience, even higher power stations are necessary. These extreme fast charge stations (XFC) should be able to recharge a BEV in less than 10 minutes and provide approximately 175 additional miles of driving. However, this introduces a host of new challenges that need to be addressed. As a result, it is expected that packs designed to meet XFC will be significantly more expensive initially than BEVs optimized for range that can reach 140kW with current technology. From the battery cell to the power grid to which these 350 kW chargers are connected, this study will discuss the issues that need to be addressed at each level in order to implement a 350 kW charging network. Although this report is U.S.-focused, the findings should be applicable to other countries with mature automotive infrastructures.

25 ENERGY STORAGE↗

Optimal charging management and infrastructure planning for free-floating shared electric vehicles

Recently, major car-sharing service providers have begun to include electric vehicles (EVs) in free-floating car-sharing fleets. For these EVs, downtime due to charging, including time spent traveling to and waiting in queues at charging stations in a sparse charging infrastructure network, is a major barrier to sustainable operation. An intuitive solution to overcome this barrier is to increase the number of fast-charging stations in the fleet service area. This paper studies the relationship between fleet vehicle downtime and the number of charging stations by modeling the fleet operations of a major car-sharing service provider. An integer programming model is developed that jointly optimizes charging station allocation, in terms of the number and location of charging stations, and the assignment of EVs to charging stations. Case study results showed that fleet vehicle charging time comprises 72-75% of the total downtime spent on charging trips. This indicates that charging time, as opposed to travel time or waiting time, is the dominant component of total fleet downtime for charging. The study also shows that by adding 5 to 20 new charging stations reduces total fleet downtime and travel time during charging trips by 2-4% and 26-49%, respectively. Although adding new charging stations to the fleet service area reduces total charging trip travel time significantly, it does not reduce total downtime significantly. Results also show that if the EV battery state of the charge (SOC) threshold—below which a charging trip is initiated—is less than 18%, not all EVs in the car-sharing fleet can be charged using the existing direct current fast chargers (DCFCs) in the fleet’s service area. Furthermore, this implies that adequate charging infrastructure coverage is required to ensure that EVs of a given range can operate in the car-sharing fleet.

25 ENERGY STORAGE↗

Fast-Charging Aging Considerations: Incorporation and Alignment of Cell Design and Material Degradation Pathways

Fast charging of batteries for electric vehicles is seen as one of the most direct ways to enhance adoption. Currently, fast charging is limited by increased cell aging, which is primarily driven by Li plating and degradation of cathode materials. Here, using combined sets of experimental and computational analysis and a suite of different charge protocols, we begin to examine the interplay between failure mode, cell designs, and ultimately aging mechanisms. Slight variation in cell design and the subsequent impacts that charge protocols have on aging can create distinct cell-to-cell variation. As little as 2% difference in porosity change at the cell negative electrode during cycling due to early Li metal plating has been found to alter the aging pathway and either accelerate or inhibit the loss due to Li plating.

25 ENERGY STORAGE↗

Port of New York and New Jersey Drayage Electrification Analysis

The National Renewable Energy Laboratory (NREL) evaluated the potential for drayage electrification in the Port of New York and New Jersey (PoNYNJ), with a focus on operators: Harbor Freight Transport (HF), Safeway Trucking (SWT), and International Motor Freight Inc (IMF). This report summarizes the data collection and electrification evaluation of all three drayage operators, includes detailed operational data, and identifies the performance requirements for battery electric tractors (BETs) and corresponding infrastructure operated within the context of PoNYNJ drayage operation. This report also details a methodology to evaluate opportunities, strategies, and challenges associated with future expansions of BETs in meeting PANYNJ emissions goals. The Port Authority has established a goal of achieving Net Zero carbon emissions by 2050 across all facilities, including from tenant and stakeholder sources such as drayage trucks. NREL used real-world performance data collected on the three PoNYNJ drayage operations, along with modeling and analysis tools to compare BET to diesel trucks. From March to July 2021, NREL collected 1Hz vehicle and engine data from 46 drayage trucks at the three operators totaling nearly 121,000 miles of operation, providing enough information to assess vehicle operations for electrification potential. A Future Automotive Systems Technology Simulator (FASTSim) electric truck powertrain model was validated using PoNYNJ data and scenarios were run to evaluate drayage truck electrification requirements over the real-world cycles. The first scenario examined BET viability with minimal changes to existing operations. This assumes the trucks charge when stopped for two hours or longer, have a functional battery size of 375 kWh, and can charge at 270 kilowatts (kW) average which are the specification of the commercially available Freightliner eCascadia. The second scenario looked at what operational, charging infrastructure, and BET technology changes would be needed to fully electrify. Finally, detailed analysis was run on charging rate structure to understand operational costs to the fleets. The studied drayage trucks averaged 5.1 MPG, spent roughly 9% of their energy at idle, and drove an average of 140 miles per day with a maximum daily distance of 573 miles. The FASTSim model results indicate a comparable BET would use 417 kWh of energy per day on average accounting for cargo weight, which is close to the full usable capacity of the eCascadia currently available on the market. Based on the daily average operating data, partial fleet electrification is possible with current technology. However, some specific days of operation would require over 1,600 kWh of energy due to longer distances traveled by the trucks and more intense operation. Trucks used for long distance and intense operation cannot be readily electrified with current technology without operational changes. Full adoption of BETs could reduce CO 2 emissions from these fleets by roughly 75% today, eliminating 76 metric tons of CO 2 (MTCO 2 ) per vehicle each year, which equates to 24,100 MTCO 2 per year for all three operators. Commercially available direct current fast chargers (DCFC) have charge rates up to 350 kW. Based on the average daily modeled energy use for each operator, current industrial rate structures, and the assumption of 350 kW peak charging, full drayage electrification would increase electricity consumption. In addition, peak demand usage would increase with unmanaged charging along with cost of electricity having a direct impact on cost per mile for electric vehicles. The resulting cost per mile for BETs along with comparable cost per mile for conventional diesel trucks are also examined at $\$$4.00 per gallon of diesel. It will be important for PANYNJ and the drayage operators within the PoNYNJ to consider these load impacts to their existing electrical infrastructure and devise operational strategies that avoid coincident charging of vehicles to mitigate demand charges. Despite these electricity cost increases, savings from reductions in diesel consumption will help offset the costs of this increased electricity consumption. However, prices of both electricity and diesel are subject to change based on various factors meaning the realized savings will vary over time. This shows BETs could be cost-competitive on an energy cost per mile basis for all scenarios while diesel is above $\$$3.00/gal. Further, if diesel prices dropped to the 15-year low of $2.33/gal, it would still be cost competitive to operate the EVs with electricity costs of 16.3 ¢/kWh or less.

33 ADVANCED PROPULSION SYSTEMS↗

Challenges of Fast Charging for Electric Vehicles and the Role of Red Phosphorous as Anode Material: Review

Electric vehicles (EVs) are being endorsed as the uppermost successor to fuel-powered cars, with timetables for banning the sale of petrol-fueled vehicles announced in many countries. However, the range and charging times of EVs are still considerable concerns. Fast charging could be a solution to consumers’ range anxiety and the acceptance of EVs. Nevertheless, it is a complicated and systematized challenge to realize the fast charging of EVs because it includes the coordinated development of battery cells, including electrode materials, EV battery power systems, charging piles, electric grids, etc. This paper aims to serve as an analysis for the development of fast-charging technology, with a discussion of the current situation, constraints and development direction of EV fast-charging technologies from the macroscale and microscale perspectives of fast-charging challenges. If the problem of fast-charging can be solved, it will satisfy consumers’ demand for 10-min charging and accelerate the development of electric vehicles. This paper summarized the development statuses, issues, and trends of the macro battery technology and micro battery technology. It is emphasized that to essentially solve the problem of fast charging, the development of new battery materials, especially anode materials with improved lithium ion diffusion coefficients, is the key. Finally, it is highlighted that red phosphorus is one of the most promising anodes that can simultaneously satisfy the double standards of high-energy density and fast-charging performance to a maximum degree.

33 ADVANCED PROPULSION SYSTEMS↗

Considerations for Corridor and Community DC Fast Charging Complex System Design

As auto manufacturers bring vehicles to market with large batteries that provide over 200 miles of driving range, interest in faster charging options for plug-in electric vehicles (PEVs) is intensifying. This report focuses on direct current fast charger (DCFC) systems and how they can be deployed to provide convenient charging for PEV drivers. First, lessons learned from previous DCFC deployment and data collection activities are shared to describe consumer experience with DCFC systems to date. Second, considerations and criteria are established for designing and upgrading DCFC complexes that provide fast-charging opportunities for PEV drivers in urban communities and on rural corridors. Third, cost estimates are shared for hypothetical high-power DCFC complexes that meet simplified design requirements. Finally, results for a business case analysis are presented that shed light on the financial challenges associated with DCFCs.

25 ENERGY STORAGE↗

Understanding the crack formation of graphite particles in cycled commercial lithium-ion batteries by focused ion beam - scanning electron microscopy

Here in this paper, the structure degradation of commercial Lithium-ion battery (LIB) graphite anodes with different cycling numbers and charge rates was investigated by focused ion beam (FIB) and scanning electron microscopy (SEM). The cross-section image of graphite anode by FIB milling shows that cracks, resulted in the volume expansion of graphite electrode during long-term cycling, were formed in parallel with the current collector. The crack occurs in the bulk of graphite particles near the lithium insertion surface, which might derive from the stress induced during lithiation and de-lithiation cycles. Subsequently, crack takes place along grain boundaries of the polycrystalline graphite, but only in the direction parallel with the current collector. Furthermore, fast charge graphite electrodes are more prone to form cracks since the tensile strength of graphite is more likely to be surpassed at higher charge rates. Therefore, for LIBs long-term or high charge rate applications, the tensile strength of graphite anode should be taken into account.

25 ENERGY STORAGE↗

Analysis of Fast Charging Station Network for Electrified Ride-Hailing Services

Today's electric vehicle (EV) owners charge their vehicles mostly at home and seldom use public direct current fast charger (DCFCs), reducing the need for a large deployment of DCFCs for private EV owners. However, due to the emerging interest among transportation network companies to operate EVs in their fleet, there is great potential for DCFCs to be highly utilized and become economically feasible in the future. This paper describes a heuristic algorithm to emulate operation of EVs within a hypothetical transportation network company fleet using a large global positioning system data set from Columbus, Ohio. DCFC requirements supporting operation of EVs are estimated using the Electric Vehicle Infrastructure Projection tool. Operation and installation costs were estimated using real-world data to assess the economic feasibility of the recommended fast charging stations. Results suggest that the hypothetical transportation network company fleet increases daily vehicle miles traveled per EV with less overall down time, resulting in increased demand for DCFC. Sites with overhead service lines are recommended for hosting DCFC stations to minimize the need for trenching underground service lines. A negative relationship was found between cost per unit of energy and fast charging utilization, underscoring the importance of prioritizing utilization over installation costs when siting DCFC stations. Although this preliminary analysis of the impacts of new mobility paradigms on alternative fueling infrastructure requirements has produced several key results, the complexity of the problem warrants further investigation.

33 ADVANCED PROPULSION SYSTEMS↗