Hierarchical Intelligent Operation of Energy Storage Systems in Power Distribution Grids
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Abstract not provided.
Abstract not provided.
The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.
The effectiveness of a thermal energy storage (TES) system is typically characterized with the help of thermal stratification or temperature gradients along the direction of heat injection, which is typically the flow direction of heat transfer fluid. The steepness of temperature gradients are a direct indicator of the effectiveness or efficiency of the heat storage or dispatch process. The temperature gradient evolution along the packed bed of ceramic particles upon saturated steam injection is presented in this work. Distributed temperature sensing based on optical frequency domain reflectometry was deployed in a packed bed of ceramic particles to capture the thermal front evolution in the axial direction. The physical processes accompanying steam injection in packed beds are complex due to phase change, transitioning two-phase flow, and changes in condensate accumulation. Therefore, the variation of thermal response of the TES system for various steam injection flow rates was experimentally studied using a high-resolution distributed temperature sensing system in a chemically inert alumina particle-packed bed. Distinct zones of different heat transfer modes were observed during the steam injection experiments. A distinct conduction zone, evident from diffuse thermal fronts, was observed at low flow rates, and these thermal gradients became sharper as the flow rate increased. The diffuse thermal fronts in the heat storage media suggest a low exergy efficiency of the TES system, as energy losses started initiating before a significant fraction of the bed was saturated with steam.
The present disclosure can provide a distributed and anonymous approach to demand response of an electricity system. The approach can conceptualize energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems, among others. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.
The soft materials used in the infrastructure of hydrogen storage and distribution systems are vulnerable because exposure to high-pressure hydrogen can lead to mechanical damage and property degradation. Some materials, such as polymers, can undergo mechanical failure due to a phenomenon wherein hydrogen gas diffuses through the polymer chains and occupies preexisting cavities or voids inside the polymer material. If the hydrogen gas pressure is reduced more quickly than hydrogen can diffuse back out of the polymer which is necessary for some applications, the trapped hydrogen gas instead escapes by rupturing the material, causing surface blistering or permanent damage. In this study, a continuum mechanics-based fully coupled diffusion-deformation model with damage is developed to predict the stress distribution and damage propagation while the polymer undergoes rapid decompression failure. The hyperelastic material model, along with the maximum principal strain failure theory, was chosen for this study as it represents the nonlinear material response with brittle failure observed in uniaxial tensile tests perfectly. EPDM polymer was chosen for this study because of its commercial availability and common use in hydrogen storage and distribution system. It has superior mechanical properties, high and low temperature resistance, and certain compounds work well in hydrogen gas. This work is useful for design engineers to alter the parameters while manufacturing polymer composites to increase their performance in a high-pressure hydrogen environment.
A high level of electric demand flexibility must be integrated into our building infrastructure to enable greater renewable energy penetration in the grid. In the U.S., 9% of electricity generated is used to cool buildings in a periodic manner, making this end-use an ideal target for active management through cool thermal energy storage (CTES) technologies. Historic uses for CTES are designed around central chilled water plants, but these systems cool less than 25% of U.S. commercial floorspace. Emerging technologies are under development to serve the many smaller distributed cooling systems, such as rooftop units (RTUs), and have the potential to add CTES to an additional 66% of cooled commercial floorspace. However, these unitary thermal storage systems (UTSS) lack the modeling and analysis tools to evaluate them in the future interactive grid context. Here, this study develops the modeling and optimization tools necessary to simultaneously examine central and distributed ice storage systems within the multi-building, connected community context. An integrated simulation-optimization workflow is created to allow for rapid customized analysis. Results demonstrate the energy and flexibility tradeoffs of various implementations.
Power systems, which range in size from small microgrids to island systems to large regional grids, are typically managed by a central controller that requires complex communication methods and can be unreliable and pose cyber security risks in certain applications, especially when controlling a larger number of nodes. We propose an inherently robust, scalable method of integration using multiple energy storage systems and distributed energy resources, which does not require any means of dedicated communication. This method moves beyond the paradigm of controlling grid frequency at a fixed value (e.g., 60 Hz), instead allowing the frequency to fluctuate within certain limits (e.g., 59.6-60.4 Hz). With a greater operating range, the frequency can carry necessary information from energy storage systems to highly variable distributed energy resources like photovoltaics, wind, hydro, etc.
Energy storage has a unique and pivotal role to play in the transition to a low-carbon economy because it can help the electric grid accommodate more renewable energy. However, a number of barriers currently impede the process of connecting energy storage systems to the distribution grid. The Toolkit and Guidance for the Interconnection of Energy Storage and Solar-Plus-Storage (the “BATRIES Toolkit”), which is the publication subject to this Final Technical / Scientific Report, provides vetted solutions to eight regulatory and technical barriers to the interconnection of standalone storage and solar-plus-storage systems (referred to as “energy storage”) to the distribution grid. These recommendations are based on over a year of research and analysis by utility and industry experts. The BATRIES Toolkit also includes model language that utilities and utility regulators can use to update state interconnection rules to reduce the costs and time to safely interconnect energy storage and solar-plus-storage systems. The solutions are nationally applicable and can be applied in diverse states and markets across the U.S.
We introduce UnifyFS, a user-level file system that aggregates node-local storage tiers available on high performance computing (HPC) systems and makes them available to HPC applications under a unified namespace. UnifyFS employs transparent I/O interception, so it does not require changes to application code and is compatible with commonly used HPC I/O libraries. The design of UnifyFS supports the predominant HPC I/O workloads and is optimized for bulk-synchronous I/O patterns. Furthermore, UnifyFS provides customizable file system semantics to flexibly adapt its behavior for diverse I/O workloads and storage devices. In this paper, we discuss the unique design goals and architecture of UnifyFS and evaluate its performance on a leadership-class HPC system. In our experimental results, we demonstrate that UnifyFS exhibits excellent scaling performance for write operations and can improve the performance of application checkpoint operations by as much as 3× versus a tuned configuration.
With the intermittency that comes with electricity generation from renewables, utilizing dynamic pricing will encourage the demand-side to respond in a smart way that would minimize the electricity costs and flatten the net electricity demand curve. Determining the optimal dynamic pricing profile that would leverage distributed storage to flatten the curve is a novel idea that needs to be studied. Moreover, the economic feasibility of utilizing distributed electrical energy storage is still not given in the literature. Therefore, in this paper, a novel way of solving a citywide dynamic model using a bilevel programming algorithm is introduced. The problem is developed as a novel non-cooperative Stackelberg game that utilizes air-conditioning systems and electrical storage through the end-users to determine the optimal dynamic pricing profile. The results show that the combined effect of utilizing demand-side air-conditioning systems and distributed storage together can flatten the curve while employing the optimal dynamic pricing profile. An economic study is performed to determine the economic feasibility of 20 different cases with different battery designs and the level of solar penetration. Three metrics were used to evaluate the economic performance of each case: the levelized cost of storage, the levelized cost of energy, and the simple payback period. Most cases had levelized cost of storage values lower than 0.457 $/kWh, which is the lower bound available in the literature. Seven out of 16 cases have a simple payback period shorter than the lifetime of the system (25 years). The case with a 100 MW PV power plant and a battery storage of size 597 MWh, was found to be the most promising case with a simple payback period of 12.71 years for the photovoltaic plant and 19.86 years for the demand-side investments.
This report describes research related to electric power system frequency support from inverter-coupled distributed energy resources (DERs). This research was initiated under the U.S. Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) and also contains work funded through a Cooperative Research and Development Agreement with Hawaiian Electric. The purpose of this report is to summarize the findings of simulations, hardware testing, power hardware-in-the-loop (PHIL) simulation, and analysis examining the effects of DER frequency support on the Oahu power system. This report also includes recommendations for consideration in the use of DER grid frequency support functionality, and related topics. Note that a previous GMLC Technical Report from this project also provided specific recommendations for the activation of one specific grid frequency support function, frequency-watt control, for overfrequency events in Hawaii. Those recommendations included recommended frequency-watt control settings, which have since been approved by the Hawaii Public Utilities Commission on October 20, 2017, for system-wide activation. This report builds on the previous report by considering not only overfrequency events but also underfrequency events, and by considering distributed energy storage systems in addition to photovoltaic (PV) systems.
The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility in development that aims to emulate the daily interactions among power production industry systems and be capable of receiving real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect the laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (a methodology that enables systems to scale and project or extrapolate datasets to desired environments while conserving the observed transient behavior based on first principles) was applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System. The thermocline system was successfully scaled and a test case was conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facility. The accelerated data were determined as able to conserve the amount of energy stored and the associated test boundary conditions were charge line maximum temperature, charge line velocity, and thermocline maximum temperature at 354 °C, 0.458 m/s, and 418 °C, respectively. The research results represented a case that required signals to be accelerated without altering the stored energy.
As the capital cost of battery energy storage systems (BESS) declines, opportunities for commercial buildings to achieve net savings through peak demand management and energy arbitrage are emerging. National Renewable Energy Laboratory researchers modeled energy storage project economics - with and without accompanying solar photovoltaic systems - using local utility rates, ASHRAE climate zones, and solar intensity data to identify regions where these systems deliver life cycle savings now and in future cost scenarios.
The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.
Energy storage plays a pivotal role in enabling power system operation with more flexibility and resilience. Unlike current practice that considers energy storages as attached ancillary devices, this paper focuses on storages as a core infrastructure by looking at their spatial distribution in the system. A sensitivity analysis based on production cost modeling is conducted to demonstrate the benefits of distributed energy storages. First, the modeling of energy storages in production cost modeling is presented. Second, potential optimal locations of distributed energy storages in a power system are discussed. Finally, multiple scenarios with various numbers and locations of additional distributed energy storages in the WECC 2030 model are created. The production cost modeling results of these scenarios show that distributed energy storages have higher utilization compared to the centralized ES units and therefore provide significantly more benefits in terms of reduction in generation cost, emission cost, and volatility of location marginal prices. A saturation effect is observed suggesting the selection of optimal locations will further improve the benefits.
The use of hydrogen as a fuel is increasing exponentially, and the most economical way to store and transport hydrogen for fuel use is as a high-pressure gas. Polymers are widely used for hydrogen distribution and storage systems because they are chemically inert towards hydrogen. However, when exposed to high-pressure hydrogen, some hydrogen diffuses through polymers and occupies the preexisting cavities inside the material. Upon depressurization, the hydrogen trapped inside polymer cavities can cause blistering or cracking by expanding these cavities. A continuum mechanics--based deformation model was deployed to predict the stress distribution and damage propagation while the polymer undergoes depressurization after high-pressure hydrogen exposure. The effects of cavity size, cavity location, and pressure inside the cavity on damage initiation and evolution inside the polymer were studied. The stress and damage evolution in the presence of multiple cavities was also studied, because interaction among cavities alters the damage and stress field. It was found that all these factors significantly change the stress state in the polymer, resulting in different paths for damage propagation. The effect of adding carbon black filler particles and plasticizer on the damage was also studied. It was found that damage tolerance of the polymer increases drastically with the addition of carbon black fillers, but decreases with the addition of the plasticizer.