Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of ARM tethered-balloon system instrumentation for supercooled liquid water and distributed temperature sensing in mixed-phase Arctic clouds

A tethered-balloon system (TBS) has been developed and is being operated by Sandia National Laboratories (SNL) on behalf of the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) User Facility in order to collect in situ atmospheric measurements within mixed-phase Arctic clouds. Periodic tethered-balloon flights have been conducted since 2015 within restricted airspace at ARM's Advanced Mobile Facility 3 (AMF3) in Oliktok Point, Alaska, as part of the AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), ERASMUS (Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems), and POPEYE (Profiling at Oliktok Point to Enhance YOPP Experiments) field campaigns. The tethered-balloon system uses helium-filled 34 m 3 helikites and 79 and 104 m 3 aerostats to suspend instrumentation that is used to measure aerosol particle size distributions, temperature, horizontal wind, pressure, relative humidity, turbulence, and cloud particle properties and to calibrate ground-based remote sensing instruments. Supercooled liquid water content (SLWC) sondes using the vibrating-wire principle, developed by Anasphere Inc., were operated at Oliktok Point at multiple altitudes on the TBS within mixed-hase clouds for over 200 h. Sonde-collected SLWC data were compared with liquid water content derived from a microwave radiometer, Ka-band ARM zenith radar, and ceilometer at the AMF3, as well as liquid water content derived from AMF3 radiosonde flights. The in situ data collected by the Anasphere sensors were also compared with data collected simultaneously by an alternative SLWC sensor developed at the University of Reading, UK; both vibrating-wire instruments were typically observed to shed their ice quickly upon exiting the cloud or reaching maximum ice loading. Temperature sensing measurements distributed with fiber optic tethered balloons were also compared with AMF3 radiosonde temperature measurements. Combined, the results indicate that TBS-distributed temperature sensing and supercooled liquid water measurements are in reasonably good agreement with remote sensing and radiosonde-based measurements of both properties. From these measurements and sensor evaluations, tethered-balloon flights are shown to offer an effective method of collecting data to inform and constrain numerical models, calibrate and validate remote sensing instruments, and characterize the flight environment of unmanned aircraft, circumventing the difficulties of in-cloud unmanned aircraft flights such as limited flight time and in-flight icing.

47 OTHER INSTRUMENTATION↗

Ultrasonic Measurements of Temperature Distribution in Extreme Environments: Results of Power Plant Testing

The most hardened insertion sensors do not perform reliably in extreme environmental conditions. We address this problem by developing an ultrasonic thermometry system for the measurements of segmental temperature distributions (MSTD) in solid materials and, specifically, across containments of energy conversion processes. The MSTD approach uses an echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features. In pulse-echo mode, these features produce a train of echoes in response to an external pulse of ultrasonic excitation created and acquired by a transducer located outside the extreme environment. The delays between the echoes encode the information on the temperature distribution in the corresponding segments of the ultrasonic propagation path, which we use to reconstruct an unknown temperature profile. This note describes the preliminary results and initial experience in applying the developed MSTD ultrasonic thermometry system to the measurements of temperatures in a utility-scale 500MW coal-fired boiler.

John, Mason↗

Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration

Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.

Distributed Strain Sensing↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Optimization of the number and locations of the calibration stations needed to monitor soil moisture using distributed temperature sensing systems: A proof-of-concept study

The single-probe heat-pulse (SPHP) technique combined with the Fiber-optic Distributed Temperature Sensing (DTS) technology can offer novel high-resolution measurements of soil moisture (θ) over spatial scales ranging from several centimeters to several kilometers. However, the key limitation of this method is in obtaining the calibration relationship between θ and soil thermal conductivity (λ) across a specific field. In a previous study, a new methodology using a Gaussian processes model was presented to account for the spatial variability in the λ-θ relationship. The model aggregated θ measurements from soil moisture sensors scattered over the SPHP transect with the corresponding DTS λ measurements at their locations. In this study, a novel methodology is tested to optimize the number and locations of soil moisture sensors required to account for the spatial variability of the λ - θ relationship to achieve higher accuracy from the SPHP technique. The proposed methodology utilizes hierarchical clustering to analyze the information contained in the spatial structure of the SPHP measurements as the soil dries from a nearly-saturated condition. The proposed methodology was tested using data from a field in Oklahoma. Monte-Carlo simulation was performed to validate the performance of the proposed methodology. The predictions obtained from the proposed methodology resulted in θ measurements accuracy comparable to those obtained from the 10% best Monte-Carlo iterations of randomly assigned soil moisture locations. Further, this study demonstrates that the proposed methodology is more efficient than the traditional practice of randomly spreading calibration soil moisture sensors along the SPHP transect.

54 ENVIRONMENTAL SCIENCES↗

Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer

We present a model and numerical simulation of a distributed temperature sensor based on a two-pulse differential coherent optical time-domain reflectometer (COTDR). The differential phase measured using a phase-sensitive Rayleigh reflectometer is shown to have a regular component, which is a linear function of temperature, and a random component, which is related to a random distribution of scattering centres in the fibre and restricts the accuracy of measurements of variations in temperature. Measurement accuracy can be improved by reducing the relative contribution of the random component via a decrease in pulse duration and/or an increase in the time delay between pulses. The spatial resolution of a differential two-pulse phase-sensitive reflectometer is shown to be determined by the time delay between pulses and to vary little with pulse duration. At a typical pulse duration (200 ns) and delay time (300 ns), the accuracy in measurements of variations in temperature in the 0.1-K range is 2 % and the spatial resolution is about 30 m. (fibre-optic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal Forecasting of Distributed Temperature Sensing in a Thermal Hydraulic System With Machine Learning and Statistical Models

We benchmark performance of long-short term memory (LSTM) network machine learning model and autoregressive integrated moving average (ARIMA) statistical model in temporal forecasting of distributed temperature sensing (DTS). Data in this study consists of fluid temperature transient measured with two co-located Rayleigh scattering fiber optic sensors (FOS) in a forced convection mixing zone of a thermal tee. We treat each gauge of a FOS as an independent temperature sensor. We first study prediction of DTS time series using Vanilla LSTM and ARIMA models trained on prior history of the same FOS that is used for testing. The results yield maximum absolute percentage error (MaxAPE) and root mean squared percentage error (RMSPE) of 1.58% and 0.06% for ARIMA, and 3.14% and 0.44% for LSTM, respectively. Next, we investigate zero-shot forecasting (ZSF) with LSTM and ARIMA trained on history of the co-located FOS only, which is advantageous when limited training data is available. The ZSF MaxAPE and RMSPE values for ARIMA are comparable to those of the Vanilla use case, while the error values for LSTM increase. We show that in ZSF, performance of LSTM network can be improved by training on most correlated gauges between the two FOS, which are identified by calculating the Pearson correlation coefficient. The improved ZSF MaxAPE and RMSPE for LSTM are 4.4% and 0.33%, respectively. Performance of ZSF LSTM can be further enhanced through transfer learning (TL), where LSTM is re-trained on a subset of the FOS that is the target of forecasting. We show that LSTM pre-trained on correlated dataset and re-trained on 30% of testing target dataset achieves MaxAPE and RMSPE values of 2.32% and 0.28%, respectively.

ARIMA↗

Distributed Temperature Sensing (DTS) to Monitor CO 2 Migration in an Enhanced Oil Recovery Field in Northern Michigan

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. MRCSP conducted analysis of CO 2 flow patterns using distributed temperature sensing (DTS) data acquired from the Chester 16 pinnacle reef located in Otsego County, Michigan. The reef has one injection well Chester 6-16 and one monitoring well Chester 8-16 where DTS is installed. DTS provides a means to track temperature within the wellbores in real time and characterize the migration patterns of CO 2 in the subsurface when DTS data is combined with other operational data such as the injection rates, bottomhole pressures and temperature. The primary objective of this study was to determine the distribution of CO 2 inflow zones in the A1 Carbonate and Brown Niagaran formations.

01 COAL, LIGNITE, AND PEAT↗

NO PLIF flow visualization and time-resolved temperature distributions in laser induced breakdown plumes

NO planar laser induced fluorescence (PLIF) is used to obtain images of laser-induced breakdown plasma plumes in NO-seeded nitrogen and dry air at near atmospheric pressure. Single-shot PLIF-images show that the plume development 5–50 μs after the breakdown pulse is fairly reproducible shot-to-shot, although the plume becomes increasingly stochastic on longer timescales, 100–500 μs. The stochastic behavior of the plume is quantified using probability distributions of the loci of the plume boundary. Analysis of the single-shot images indicates that the mixing of the plume with ambient gas on sub-ms time scale is insignificant. The induced flow velocity in the plume is fairly low, up to 30 m s –1 , suggesting that laser breakdowns are ineffective for mixing enhancement in high speed flows. The ensemble-averaged PLIF images indicate the evolution of the plume from an initially elongated shape to near-spherical to toroidal shape, with a subsequent radial expansion and formation of an axial jet in the center. Temperature distributions in the plume in air are obtained from the NO PLIF images, using two rotational transitions in the NO(X, v' = 0 → A, v'' = 0) band, J'' = 6.5 and 12.5 of the Q R 12 + Q 2 branch. The results indicate that the temperature in the plume remains high, above 1000 K, for approximately 100 μs, after which it decays gradually, to below 500 K at 500 μs. The residual NO fraction in the plume is ~0.1%, indicating that repetitive laser-assisted ignition may result in significant NO-generation. Furthermore, these measured temperature and velocity distributions can be used for detailed validation of kinetic models of laser-induced breakdown and assessment of their predictive capability.

42 ENGINEERING↗

Calibration of Distributed Temperature Sensors Using Commercially Available SMF-28 Optical Fiber From 22 °C to 1000 °C

Optical frequency domain reflectometry (OFDR) is a family of optical techniques which can be used to produce distributed temperature measurements from the spectral shift of an interference pattern based on the Rayleigh backscatter signature of an optical fiber. Adaptive signal processing techniques have recently been used with OFDR to record meaningful spectral shift data from commercially available SMF-28 optical fibers heated beyond 950 °C. Furthermore, a correlation between the measured spectral shift and temperature has not yet been developed at these high temperatures. To extend the measurable temperature range of OFDR in SMF-28, this work describes the development of such a correlation from room temperature (22 °C) to 1000 °C. The relationship between spectral shift and temperature change over this range was found to be best characterized by the fourth-order polynomial ΔT=(-4.241 * 10 -11 )S 4 + (-2.017 * 10 -7 )S 3 + (-3.677 * 10 -4 )S 2 + (-0.8057)S, where ΔT represents the temperature difference compared to the reference temperature, and S represents the spectral shift measured by the fibers. The calibration developed in this work assumes that the fiber has been fully annealed by heating the fiber to 1000 °C for a few hours. This paper is the first to demonstrate the calibration and use of SMF-28 distributed optical fiber sensors up to 1000 °C, enabled using adaptive OFDR-based signal processing.

47 OTHER INSTRUMENTATION↗

A compact x-ray spectrometer for measurements of electron temperature distributions in inertial confinement fusion implosions at OMEGA

The Wedge Range Filter (WRF), commonly used for proton spectroscopy at the OMEGA Laser Facility and National Ignition Facility, is adapted to measure the x-ray continuum spectrum through transmission measurement using a continuous-gradient filter. Continuum x rays emitted from the hotspot of an implosion contain information about the plasma composition and electron temperature. The WRF data are leveraged to probe this distribution, specifically the electron temperature distribution. In this work, the data recorded with the WRF are forward modeled using a temperature distribution model folded with the WRF response function. An uncertainty analysis is conducted through a Bayesian regression algorithm using a Hamiltonian Monte Carlo sampler. This analysis enables the uncertainties in the instrument response to be folded into the uncertainty estimation of the electron temperature and absolute x-ray emission. Data analysis for a series of OMEGA implosions is presented and compared with radiation hydrodynamic simulations.

Lasers↗

Optimizing temperature distributions for training neural quantum states using parallel tempering

Parametrized artificial neural networks (ANNs) can be very expressive ansatzes for variational algorithms, reaching state-of-the-art energies on many quantum many-body Hamiltonians. Nevertheless, the training of the ANN can be slow and stymied by the presence of local minima in the parameter landscape. One approach to mitigate this issue is to use parallel tempering methods, and in this work, we focus on the role played by the temperature distribution of the parallel tempering replicas. Using an adaptive method that adjusts the temperatures in order to equate the exchange probability between neighboring replicas, we show that this temperature optimization can significantly increase the success rate of the variational algorithm with negligible computational cost by eliminating bottlenecks in the replicas' random walk. Furthermore, we demonstrate this using two different neural networks, a restricted Boltzmann machine and a feedforward network, which we use to study a toy problem based on a permutation invariant Hamiltonian with a pernicious local minimum and the 𝐽 1 −𝐽 2 model on a rectangular lattice.

Neural network simulations↗

Understanding the Effect of Sample Geometry on Temperature Distribution during Optical Floating Zone Crystal Growth in Vacuum Environment through Heat Transfer Modeling

Optical floating zone furnaces (OFZ) have had a transformative impact on fundamental science due to their ability to rapidly produce large single crystals of a wide variety of complex materials. However, a quantitative understanding of the OFZ growth environment is generally lacking due to the difficulty of measuring the local sample temperatures during OFZ growth, as well as to the general lack of information about the temperature-dependent physical parameters needed to model heat transfer. To overcome these challenges, we apply a physics-based heat transfer model, parametrized by measurements from synchrotron experiments and a machine-learning (ML) algorithm, to simulate the temperature distributions of samples heated in an OFZ furnace in a vacuum environment. This model is used to quantitatively understand how the sample maximum temperature and temperature gradient (key parameters that influence the success of crystal growth) are affected by the rod size, rod shape, and heat-zone position on the rod. The results of this study can be applied to make informed decisions on how crystal growth parameters can be tuned to modify temperature profiles and to optimize crystal growth outcomes even when data on internal sample temperature profiles (e.g., those obtained through in situ synchrotron experiments) are not accessible.

36 MATERIALS SCIENCE↗

A Study of Temperature Distribution and Thermal Stresses in a Hot Rock Due to Rapid Cooling

Thermal stresses may be induced in a hot dry rock when a cold fluid is injected in the well. To study this problem, we look at the thermoelastic response of a hot rock that is suddenly cooled. The cooling is assumed to be either at a constant temperature or at a constant heat flux per unit depth. Our approach is to nondimensionalize the equations and perform a parametric study and look at the temperature distribution and the induced-thermal stresses. The results indicate that depending on the extent of cooling and the cooling time, thermal stresses can be induced. Numerical simulations on sandstone, with an initial uniform temperature of 473 K, are also carried out. The results show that if the cooling is due to the surface temperature maintained at 463 K (10 °C lower than the initial temperature of the hot rock), thermal stresses that are larger than the rock tensile strength could be induced. When the cooling is due to a constant surface heat flux, this temperature can be reached after about 777 days of cooling with a minimum value of a heat flux of -20 W/m.

Tran, Phuoc↗

Development of fracture diagnostic methods for fluid distribution based on quantitative interpretation of distributed acoustic sensing and distributed temperature sensing

Multistage hydraulic fracturing design on horizontal wells has significantly evolved with larger fluid volume, more fracturing stages, and tighter perforation cluster spacing to efficiently stimulate unconventional reservoirs. From the published field observations, the recent fracturing design results in complex fracture networks or swarm of fractures. Fracture treatment evaluation is extremely challenging in such a case because of the large amount of variables in well completion and stimulation design. Combined measurements from different technologies can help in fracture diagnosis. Fluid distribution, either during fracture injection or during production, directly relates to the stimulation efficiency at the cluster level and at the stage level. Because it is unlikely in the real world to distribute the injected fluid uniformly among all the clusters, we need diagnostic techniques to generate the flow profile along a lateral. Fiber-optic measurements, such as distributed acoustic sensing (DAS) and distributed temperature sensing (DTS), are currently used to diagnose downhole flow conditions. This technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs. For optimizing a fracturing design, we also need to understand how the design parameters are correlated with the stimulation efficiency. In this study, we combine two sets of models of DAS and DTS data interpretation for injected fluid volume distribution. The DAS is interpreted based on an empirical correlation between fluid flow rates and frequency band energy from the acoustic signals. The DTS is interpreted by performing temperature history match-based thermal energy conservation. Because of the completely different physics behind the interpretations, the confirmation of two interpretations provides confidence in fluid distribution.

Geochemistry & Geophysics↗