Search NASASearch

SEARCH · Search NASA

Results for “Doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Remote measurement utilizing NASA's scanning laser Doppler systems. Volume 2: Laser Doppler dust devil velocity profile measurement program

The first detailed velocity profile data on thermally induced dust vortices are presented. These dust devils will be analyzed and studied to determine their flow fields and origin in an effort to correlate this phenomena with the generation and characteristics of tornadoes. A continuing effort to increase mankind's knowledge of vortex and other meteorological phenomena will hopefully allow the prediction of tornado occurrence, their path, and perhaps eventually even lead to some technique for their destruction.

Howle, R. E.

Dual-Doppler Feasibility Study

When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any radar geometry issues at the NWS MLB radar, such as the "cone of silence" or beam blockage. In the event of a radar outage at one of the sites, the multi-radar algorithms would provide continuing coverage of the area through use of the data from the remaining operational radar sites. There are several options to collect, edit, synthesize and display dual-Doppler data sets. These options include commercial packages available for purchase and a variety of freeware packages available from the National Center for Atmospheric Research (NCAR) for processing raw radar data. However, evaluation of the freeware packages revealed that they do not have sufficient documentation and configuration control to be certified for 45 SW use. Additionally, a TI data line must be installed/leased from the NWS MLB office and CCAFS to enable the receipt of NWS MLB raw radar data to use in the dual-Doppler synthesis. Integration of the TI data line into the Eastern Range infrastructure that will meet the security requirements necessary for 45 SW use is time-consuming and costly. Overall evaluation indicates that establishment of the dual-Doppler capability using the existing operational radar systems is desirable and feasible with no technical concerns. Installation of such a system represents a significant enhancement to forecasting capabilities at the 45 WS and at NWS MLB. However, data security and cost considerations must be evaluated in light of current budgetary constraints. In any case, gaining the dual-Doppler capability will provide opportunities for better visualization of the wind field and better forecasting of the onset of convection and severe weather events to support space launch operations at KSC and CCAFS.

Huddleston, Lisa L.

Differenced Doppler tracking in interplanetary navigation - The Magellan cruise reconstruction

The Magellan mission was the first in which Doppler and differenced Doppler tracking data were acquired at X-band uplink/downlink frequencies from the Deep Space Network (DSN). This paper describes a reconstruction of the Venus approach-phase navigation investigating the capabilities of these data types, which are up to an order of magnitude more precise than similar data acquired at S-band frequencies in previous missions. Comparisons of orbit solutions obtained with Doppler, Doppler plus differenced Doppler, and Doppler plus delta-differential one-way Range (DeltaDOR) data indicate that both differenced Doppler and DeltaDOR yield improvements of factors of 3 to 5 over the accuracy of the Doppler-only solutions obtained during Venus approach operations, in which the Doppler data were deweighted from their inherent accuracy due to mismodeling problems.

Ryne, Mark S.

New Doppler echocardiographic applications for the study of diastolic function

Doppler echocardiography is one of the most useful clinical tools for the assessment of left ventricular (LV) diastolic function. Doppler indices of LV filling and pulmonary venous (PV) flow are used not only for diagnostic purposes but also for establishing prognosis and evaluating the effect of therapeutic interventions. The utility of these indices is limited, however, by the confounding effects of different physiologic variables such as LV relaxation, compliance and filling pressure. Since alterations in these variables result in changes in Doppler indices of opposite direction, it is often difficult to determine the status of a given variable when a specific Doppler filling pattern is observed. Recently, color M-mode and tissue Doppler have provided useful insights in the study of diastolic function. These new Doppler applications have been shown to provide an accurate estimate of LV relaxation and appear to be relatively insensitive to the effects of preload compensation. This review will focus on the complementary role of color M-mode and tissue Doppler echocardiography and traditional Doppler indices of LV filling and PV flow in the assessment of diastolic function.

NASA Discipline Cardiopulmonary

A Doppler centroid estimation algorithm for SAR systems optimized for the quasi-homogeneous source

Radar signal processing applications frequently require an estimate of the Doppler centroid of a received signal. The Doppler centroid estimate is required for synthetic aperture radar (SAR) processing. It is also required for some applications involving target motion estimation and antenna pointing direction estimation. In some cases, the Doppler centroid can be accurately estimated based on available information regarding the terrain topography, the relative motion between the sensor and the terrain, and the antenna pointing direction. Often, the accuracy of the Doppler centroid estimate can be improved by analyzing the characteristics of the received SAR signal. This kind of signal processing is also referred to as clutterlock processing. A Doppler centroid estimation (DCE) algorithm is described which contains a linear estimator optimized for the type of terrain surface that can be modeled by a quasi-homogeneous source (QHS). Information on the following topics is presented: (1) an introduction to the theory of Doppler centroid estimation; (2) analysis of the performance characteristics of previously reported DCE algorithms; (3) comparison of these analysis results with experimental results; (4) a description and performance analysis of a Doppler centroid estimator which is optimized for a QHS; and (5) comparison of the performance of the optimal QHS Doppler centroid estimator with that of previously reported methods.

Jin, Michael Y.

Designing clutter rejection filters with complex coefficients for airborne pulsed Doppler weather radar

Ground clutter interference is a major problem for airborne pulse Doppler radar operating at low altitudes in a look-down mode. With Doppler zero set at the aircraft ground speed, ground clutter rejection filtering is typically accomplished using a high-pass filter with real valued coefficients and a stopband notch centered at zero Doppler. Clutter spectra from the NASA Wind Shear Flight Experiments of l991-1992 show that the dominant clutter mode can be located away from zero Doppler, particularly at short ranges dominated by sidelobe returns. Use of digital notch filters with complex valued coefficients so that the stopband notch can be located at any Doppler frequency is investigated. Several clutter mode tracking algorithms are considered to estimate the Doppler frequency location of the dominant clutter mode. From the examination of night data, when a dominant clutter mode away from zero Doppler is present, complex filtering is able to significantly increase clutter rejection over use of a notch filter centered at zero Doppler.

Jamora, Dennis A.

Design and Calibration of Autonomous Coherent Doppler Lidar for Space Missions

Developed a new algorithm for the simulation of three dimensional homogeneous turbulent velocity fields. For typical atmospheric conditions it is impossible to produce a simulated velocity field that simultaneously satisfy a given spatial correlation and the corresponding spatial spectrum because of spectral aliasing. The new algorithms produce a turbulent velocity field which has accurate spatial correlations which is required for performance predictions from space-based systems. Developed a new algorithm for extracting the spatial statistics of the atmospheric velocity field using coherent Doppler lidar. The performance of the algorithm was compared with past methods and the new algorithm produces useful results for space-based data, which was not possible before. Developed new methods for verification of the errors in ground-based and space-based Doppler lidar wind measurements. These new methods do not require independent in situ data. This is an important issue for the verification of space-based Doppler lidar measurements of the global wind field. The performance of the new algorithm was compared with past results for both space-based and ground-based operation. The new algorithm has the best performance and is the only algorithm that performed satisfactory for spacebased operation. The performance of coherent Doppler lidar for a space missions with various scanning geometries was determined using computer simulation which contained the effects of random instrumental velocity errors, wind shear, wind variability along the range-gate and from shot-to-shot, and random variations in atmospheric aerosol backscatter over the measurement volume. The bias in the velocity estimates was small and the accuracy in the is typically less than 0.5 m/s for high signal conditions. For a large number of shot per velocity estimate, the threshold signal level for acceptable estimates is proportional to the number of shots to the minus one half power. This agrees with previous results determined for ground-based measurements. The use of multi-element optical detectors for autonomous operation of coherent Doppler lidar was shown to be a very promising technique. Optimal detector geometries were determined by computer simulation of performance: for ground-based testing with a fixed calibration target and for space-based operation using the random surface returns. The effects of refractive turbulence on ground-based calibration of coherent Doppler lidar was determined by computer simulations and compared with theoretical predictions. New techniques were required to correctly predict performance for the focused beam geometry commonly used for verification of space-based operation. An improved velocity estimator was evaluated for space-based applications were signal shot measurements are used to produce vector wind measurements. This permits more accurate measurements when the signal level is not known a priori or not available from multiple shot measurements. The average Doppler lidar signal spectrum including the effects of velocity turbulence was derived and calculated. This permits new estimation algorithms for turbulence based on spectral estimates. In situ atmospheric measurements were conducted and analyzed using an instrumented kite-platform. This work helps provide the required in situ data for verification of Doppler lidar velocity statistics.

Frehlich, Rod G.

Is Doppler tissue velocity during early left ventricular filling preload independent?

BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.

Non-NASA Center

Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography

OBJECTIVE: To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN: The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tested prospectively in a further 84 patients (test group). SETTING: Three tertiary referral centres. INTERVENTIONS: Flow velocities in grafts were recorded at rest and during hyperaemia induced by dipyridamole (0.56 mg/kg/4 min), under the guidance of transthoracic colour Doppler flow mapping. Findings on transthoracic Doppler were compared with angiography. MAIN OUTCOME MEASURES: Feasibility of identifying open grafts by Doppler and diagnostic accuracy for Doppler detection of significant (>/= 70%) graft stenosis. RESULTS: In the test group the identification rate for mammary artery grafts was 100%, for saphenous vein grafts to left anterior descending coronary artery 91%, for vein grafts to right coronary artery 96%, and for vein grafts to circumflex artery 90%. Coronary flow reserve (the ratio between peak diastolic velocity under hyperaemia and at baseline) of < 1.9 (95% confidence interval 1.83 to 2.08) had 100% sensitivity, 98% specificity, 87.5% positive predictive value, and 100% negative predictive value for mammary artery graft stenosis. Coronary flow reserve of < 1.6 (95% CI 1.51 to 1.73) had 91% sensitivity, 87% specificity, 85.4% positive predictive value, and 92.3% negative predictive value for significant vein graft stenosis. CONCLUSIONS: Transthoracic Doppler can provide non-invasive assessment of CABG patency.

Multicenter Study

Doppler lidar results from the San Gorgonio Pass experiments

During FY-84, the Doppler Lidar data from the San Gorgonio Pass experiments were analyzed, evaluated, and interpreted with regard to signal strength, signal width, magnitude and direction of velocity component and a goodness parameter associated with the expected noise level of the signal. From these parameters, a screening criteria was developed to eliminate questionable data. For the most part analysis supports the validity of Doppler Lidar data obtained at San Gorgonio Pass with respect to the mean velocity magnitude and direction. The question as to whether the Doppler width could be interpreted as a measure of the variance of the turbulence within the Doppler Lidar System (DLS) focal volume was not resolved. The stochastic nature of the Doppler broadening from finite residence time of the particles in the beam as well as other Doppler broadening phenomenon tend to mask the Doppler spread associated with small scale turbulence. Future tests with longer pulses may assist in better understanding.

Cliff, W. C.

Precise orbit determination of high-earth elliptical orbiters using differenced Doppler and range measurements

Recent advances in Deep Space Network station calibration methods have led to renewed interest in the use of differenced Doppler and range data types for interplanetary navigation. Described here is an orbit determination error analysis of the performance of these differenced data types when used with conventional two-way Doppler for precise navigation of High-Earth Orbiters. Three highly elliptical Earth orbits are investigated, with apogee heights on the order of 20,000 km, 70,000 km, and 156,000 km. Results indicate that the most significant navigational accuracy improvements, relative to the performance obtained from two way Doppler alone, are achieved for the lowest altitude orbit by using differenced Doppler measurements with two way Doppler (assuming that spacecraft onboard downlink antennas have no ground footprint limitation in the near-apogee regime). In the case of the two higher altitude orbits, accuracy improvements over Doppler-only performance, although less dramatic, are also achieved when differenced range measurements are combined with two-way Doppler.

Estefan, J. A.

Precise orbit determination of high-earth elliptical orbiters using differenced Doppler and ranging measurements

Recent advances in Deep Space Network station calibration methods have led to renewed interest in the use of differenced Doppler and range data types for interplanetary navigation. Described here is an orbit determination error analysis of the performance of these differenced data types when used with conventional two-way Doppler for precise navigation of High-Earth Orbiters. Three highly elliptical earth orbits are investigated, with apogee heights on the order of 20,000 km, 70,000 km, and 156,000 km. Results indicate that the most significant navigational accuracy improvements, relative to the performance obtained from two way Doppler alone, are achieved for the lowest altitude orbit by using differenced Doppler measurements with two way Doppler (assuming that spacecraft onboard downlink antennas have no ground footprint limitation in the near-apogee regime). In the case of the two higher altitude orbit accuracy improvements over Doppler-only performance, although less dramatic, are also achieved when differenced range measurements are combined with two-way Doppler.

Estefan, Jeff A.

Solar cycle variation of interplanetary disturbances observed as Doppler scintillation transients

Interplanetary disturbances characterized by plasma that is more turbulence and/or moves faster than the background solar wind are readily defected as transients in Doppler scintillation measurements of the near-Sun solar wind. Systematic analysis of over 23,000 hours of Pioneer Venus Orbiter Doppler measurements obtained inside 0.5 AU during 1979-1987 have made it possible for the first time to investigate the frequency of occurrence of Doppler scintillation transients under solar minimum conditions and to determine its dependence on solar cycle. On the basis of a total of 142 transients, Doppler scintillation transient rates vary from a high of 0.22 in 1979 (one every 4.6 days) to a low of 0.077 transients/d in 1986 (one every 13 days), a decrease by almost a factor of 3 from solar maximum to solar minimum. This solar cycle variation, the strongest yet of any solar wind Doppler scintillation property, is highly correlated with both solar activity characterized by sunspot number and the coronal mass ejection rates deduced from Solswind and Solar Maximum Mission (SMM) coronagraph observations. These results indicate that coronal mass ejections and Doppler scintillation transients are closely related not just during solar maximum, as occasional individual comparisons have shown in the past, but throughout the entire solar cycle, and strengthen the notation that the Doppler scintillation and optical transients are different manifestations of the same physical phenomenon. The magnitudes of the transients, as described by the ratio of peak to pretransient scintillation levels (EF for enhancement factor), and their distribution iwth heliocentric distance also vary with solar cycle. While EF tends to diminish with increasing heliocentric distance during high solar activity, it is more evenly distributed during low solar activity. EF is also lower during solar minimum, as 13% of the transients during solar maximum have values exceeding 23, the highest EF observed during solar minimum. These results are consistent with the fact that occasional major fast-moving interplanetary shocks that are observed during solar maximum are very rate during solar minimum.

Woo, Richard

Rain Fallspeeds and Rates Derived from Airborne Nadir-Pointing Doppler Radar Measurements

The use of vertical-incidence Doppler velocity in addition to radar reflectivity may yield information on drop size distribution and therefore result in better rainrate estimates. Doppler velocity can provide useful information on the raindrop size distribution. Doppler velocities from a zenith-pointing radar represent the sum of the mean reflectivity-weighted hydrometeor fallspeed and the vertical air motion. Dual-parameter rain estimation methods using the Doppler velocity, require that the latter can be removed, or is negligible. Atlas et al. (1972) derived relations between Doppler velocity, reflectivity, and rain rate assuming an exponential size distribution for rain. Ulbrich (1994) expanded on this work by deriving the relation between the Doppler velocity and the reflectivity assuming a Gamma size distribution. This distribution provides a more realistic representation of the small rain drops. To get accurate information on raindrop size distributions with the above method, the air motions must be removed from the observed Doppler velocities

Heymsfield, Gerald M.

Compact, High Energy 2-micron Coherent Doppler Wind Lidar Development for NASA's Future 3-D Winds Measurement from Space

This paper presents an overview of 2-micron laser transmitter development at NASA Langley Research Center for coherent-detection lidar profiling of winds. The novel high-energy, 2-micron, Ho:Tm:LuLiF laser technology developed at NASA Langley was employed to study laser technology currently envisioned by NASA for future global coherent Doppler lidar winds measurement. The 250 mJ, 10 Hz laser was designed as an integral part of a compact lidar transceiver developed for future aircraft flight. Ground-based wind profiles made with this transceiver will be presented. NASA Langley is currently funded to build complete Doppler lidar systems using this transceiver for the DC-8 aircraft in autonomous operation. Recently, LaRC 2-micron coherent Doppler wind lidar system was selected to contribute to the NASA Science Mission Directorate (SMD) Earth Science Division (ESD) hurricane field experiment in 2010 titled Genesis and Rapid Intensification Processes (GRIP). The Doppler lidar system will measure vertical profiles of horizontal vector winds from the DC-8 aircraft using NASA Langley s existing 2-micron, pulsed, coherent detection, Doppler wind lidar system that is ready for DC-8 integration. The measurements will typically extend from the DC-8 to the earth s surface. They will be highly accurate in both wind magnitude and direction. Displays of the data will be provided in real time on the DC-8. The pulsed Doppler wind lidar of NASA Langley Research Center is much more powerful than past Doppler lidars. The operating range, accuracy, range resolution, and time resolution will be unprecedented. We expect the data to play a key role, combined with the other sensors, in improving understanding and predictive algorithms for hurricane strength and track. 1

Singh, Upendra N.

An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P <.0001). In contrast to the mitral inflow velocities, mitral annulus early diastolic velocity decreased steadily (12.3-7.3 cm/s) resulting in a dramatic decrease in mitral annulus early/late (1.22-0.57) diastolic velocity with no tendency toward pseudonormalization. The color M-mode Doppler flow propagation velocity also showed significant steady decrease (57-24 cm/s) throughout the pacing period. Multiple regression analysis chose mitral annulus systolic velocity (r = 0.895, P <.0001) and propagation velocity (r = 0.782, P <.0001) for the most important factor predicting LV systolic and diastolic function, respectively. CONCLUSIONS: Doppler tissue echocardiography and color M-mode Doppler flow could evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

Evaluation Studies

Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application

This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.

NASA Discipline Cardiopulmonary

Configuration and Evaluation of a Dual-Doppler 3-D Wind Field System

Current LSP, GSDO, and SLS space vehicle operations are halted when wind speeds from specific directions exceed defined thresholds and when lightning is a threat. Strong winds and lightning are difficult parameters for the 45th Weather Squadron (45 WS) to forecast, yet are important in the protection of customer vehicle operations and the personnel that conduct them. A display of the low-level horizontal wind field to reveal areas of high winds or convergence would be a valuable tool for forecasters in assessing the timing of high winds, or convection initiation and subsequent lightning occurrence. This is especially important for areas where no weather observation platforms exist. Developing a dual-Doppler radar capability would provide such a display to assist forecasters in predicting high winds and convection initiation. The wind fields can also be used to initialize a local mesoscale numerical weather prediction model to help improve the model forecast winds, convection initiation, and other phenomena. The 45 WS and NWS MLB tasked the Applied Meteorology Unit (AMU) to develop a dual- Doppler wind field display using data from the 45th Space Wing radar, known as the Weather Surveillance Radar (WSR), NWS MLB Weather Surveillance Radar 1988 Doppler (KMLB), and the Orlando International Airport Terminal Doppler Weather Radar (KMCO). They also stipulated that the software used should be freely available. The AMU evaluated two software packages and, with concurrence from NWS MLB and the 45 WS, chose the Warning Decision Support System-Integrated Information (WDSS-II). The AMU collected data from two significant weather cases: a tornadic event on 14 April 2013 and a severe wind and hail event on 12 February 2014. For the 14 April case, the data were from WSR and KMLB. For the 12 February case, the data were from KMCO and KMLB. The AMU installed WDSS-II on a Linux PC, then processed and quality controlled the radar data for display and analysis using WDSS-II tools. Because of issues with de-aliasing the WSR velocity field, the AMU did not use data from this radar in this study and only analyzed the 12 February case. Merging the data to create the dual-Doppler analysis involved several steps. The AMU used instructions from the WDSS-II website and discussion forum to determine the correct tools to use for the analysis, and was successful in creating a merged reflectivity field, which was critical to the success of creating a merged velocity field. However, the AMU was unable to create a merged velocity field. The AMU researched the WDSS-II forum for discussions on similar issues, asked questions on the forum, and tested different options and values in the merger tool with no success. Developing a dual-Doppler wind field was the main goal of this task, but that was not accomplished. It could be an issue of not using the correct options or the correct value for the options used, or there could be issues with the radar data. There is a follow-on AMU task to install the operational version of WDSS-II in the NWS MLB office. This will provide more opportunities to try different options and input values in order to create a merged wind field from KMCO and KMLB.

Doppler radar