2D coherence imaging measurements of C 2+ ion temperatures in the divertor of Wendelstein 7-X

For the first time, 2D ion temperature values are derived from coherence imaging spectroscopy (CIS) fringe contrast measurements by taking Zeeman line broadening effects into account during the analysis procedure of a spatial-heterodyne CIS instrument. This allowed 2D images of C 2+ ion temperatures (T i ) across the 3D-shaped island divertor of the Wendelstein 7-X stellarator. Ion temperatures ranging from 10 to 20 eV are observed for the C 2+ impurity species in the region above the divertor targets. During the transition from the attached to the detached plasma state, the C 2+ radiation zone moves from close to the divertor target towards the last closed flux surface. Within this radiation zone, C 2+ temperature does not decrease significantly. Experimentally, the coherence imaging measurements were cross-calibrated at one poloidal cross-section using a high resolution Echelle spectrometer, that shared its sightlines with the coherence imaging diagnostic. The spectra demonstrated that, apart from Doppler broadening, the Zeeman effect significantly contributes to the spectral line broadening and cannot be neglected when analyzing the CIS contrast data for T i extraction in the edge and scrape-off-layer of Wendelstein 7-X (W7-X), due to the relatively low temperatures (T i < 100 eV) and high magnetic fields (B ≈ 2.5 T).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

Two-photon Rydberg EIT resonances in non-collinear beam configurations

We study the modifications of Rydberg EIT resonances in non-collinear geometry in which the two required optical fields cross at a small non-zero angle. We observe a strong broadening and amplitude reduction even for small angles when compared to exact counter-propagating and co-propagating collinear geometries. We confirm that such EIT peak deterioration results from the additional Doppler broadening due to the transverse velocity distribution of atoms. The numerical simulation closely matches the experimental measurements. While a non-collinear geometry provides improved spatial resolution for Rydberg EIT electrometry, we conclude that the crossing angle must be small to maintain field sensitivity.

Su, Kevin↗

Correct Interpretations of ENDF-102 Definitions for Resonance Effects

My Uncle Willie circa 1600 wrote “What’s in a name; a rose by any other name would smell as sweet.” I fear in this case we have a somewhat similar problem in that we may be using the same word but are not using the same definition; specifically, the word Unresolved. The simplest physics definition as it applies to neutron resonances, is the energy point where we can no longer see/measure ALL – let me repeat that – ALL - of the individual resonances. That seems simple and clear, but the question is: how to represent resonances beyond this point in order to accurately reproduce the effects we have seen in measurements and expect/need to reproduce in our applications. We know there are more, unseen resonances, otherwise we wouldn’t say Unresolved. The ENDF approach is well defined in ENDF-102 and simple: for ENDF data the only way to represent Unresolved data is by using a theoretical model to define the distribution of resonances, including those that are too narrow to measure (i.e., are unresolved). It is important to note that in ENDF this is the one and only Unresolved model, e.g., there is no provision in ENDF to accurately define individually ALL resonances above the Resolved energy range – by ALL here I mean both those that we can measure and those that we cannot individually measure, but that theory and integral measurements tells us are present. An alternative approach, which would appear to be equally valid, would be to include the latest measured data as tabulated energy expendent data extending upwards in energy above the Resolved energy range. In this approach the evaluation would not include an ENDF style Unresolved energy range; it would only include a Resolved resonance region, followed by tabulated higher energy points, representing the resonances that could be measured beyond the Resolved range. But an important point to note: By listing these resonances above the resolved energy one admits that at least some resonances in this energy range are missing as Unresolved; i.e., they are too narrow or overlapping to measure. The purpose of this paper is to illustrate that the later approach, while done with good intentions, and appearing to be valid/adequate in plots, does not meet the need of our engineering applications. Why? As we will see below, of these two possible approaches, only the ENDF use of a model to statistically include the missing, i.e., unresolved, resonances, can meet our engineering needs to reproduce the integral effects we have measured and understand. Only with this statistical model can we predict and include in our calculated results the important effects of temperature (Doppler broadening), and energy integrals (self-shielding). Below I will first present results using two ENDF/B-VIII.1 evaluations, U235 and U238, that use the correct ENDF-102 definition of an Unresolved resonance region, using a statistical model to include the effects of resonances that theory predicts are present, but are too narrow to measure. These two evaluations reproduce the expected temperature (Doppler) and energy integral (self-shielding) effects that we expect. Next I will present results using one ENDF/B-VIII.1 evaluation, 26-Fe-56, that does not use an ENDF-102 Unresolved resonance region; instead above its Resolved energy range it lists many tabulated energy points, that look like measured data, but by definition, since they are included above the ENDF Resolved energy range there are missing Unresolved resonances, i.e., there are missing the resonances that are too narrow to resolve, i.e., are unresolved. My conclusion, and I hope yours, is that the below figures illustrate that this approach does not reproduce the temperature and energy integrals that we expect and need to accurately calculate results for our fission reactor calculations. As such this approach should not be used in ENDF formatted evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accessing tens-to-hundreds femtoseconds nuclear state lifetimes with low-energy binary heavy-ion reactions

A novel Monte Carlo technique has been developed to determine lifetimes of excited states in the tens-to-hundreds femtoseconds range in products of low-energy heavy-ion binary reactions, with complex velocity distributions. The method is based on a detailed study of Doppler-broadened γ-ray lineshapes. Its relevance is demonstrated in connection with the 18 O(7.0MeV/u)+ 181 Ta experiment, performed at GANIL with the AGATA+VAMOS+PARIS setup, to study neutron-rich O, C, N, ... nuclei. Excited states in 17 O and 19 O, with known lifetimes, are used to validate the method over the ~20-400fs lifetime-sensitivity range. Emphasis is given to the unprecedented position resolution provided by γ-tracking arrays, which turns out to be essential for reaching the required accuracy in Doppler-shift correction. The technique is anticipated to be an important tool for lifetime investigations in exotic neutron-rich nuclei, produced with intense ISOL-type beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The mechanism behind the high radiation tolerance of Fe-Cr alloys

With the great demand for high radiation tolerant materials for advanced nuclear energy technologies, Fe-Cr alloys are at the forefront with long standing validated performance. Yet, the real mechanism behind their high radiation resistance is in question and understanding the effect of varying Cr percentage is a grand challenge limiting further improvements. Here we applied depth resolved atomic scale probe of defects to uncover the real mechanism on how Cr improves radiation resistance and explain the controversial impact of increasing Cr percentage. By combining depth-resolved positron annihilation lifetime spectroscopy and Doppler broadening spectroscopy we investigated the effect of Cr alloying on the formation and evolution of atomic size clusters induced by ion irradiation in Fe. We also used atom probe tomography to investigate the possible presence of Cr clusters or a’ phase with high Cr composition. The study reveals that the well-known resistance to radiation in Fe-Cr alloys arises from the stabilization of vacancy clusters around Cr atoms which act as sinks for radiation-induced defects. Thus, Cr atoms do not provide a direct sink for interstitials; rather defect complexes for that consist of Cr atoms and vacancies in turn act as sinks for irradiation-induced vacancies and interstitials. Most importantly, we find that lower amounts of Cr create smaller, uniformly distributed defect clusters that act as efficient sinks for radiation damage, but larger quantities of Cr form a defect structure that is less homogenous in size and spatial distribution, resulting in less efficient damage recombination. No evidence of phase a’ was found before or after irradiation, which indicates that it does not contribute to the observed radiation tolerance.

36 MATERIALS SCIENCE↗

Defect Characterization Using Positron Annihilation Spectroscopy on Laser-Ablated Surfaces

In recent years, short, pulsed laser ablation has been gaining popularity for machining small-scale test geometries from bulk samples and for efficient serial sectioning. These laser-based techniques are being added to the toolbox in material science, which makes it necessary to understand the changes in the material that occur from the laser–material interaction. Positron annihilation spectroscopy is a unique, nondestructive technique to investigate small defects in materials difficult to investigate by other tools. In this work, Doppler broadening and positron lifetime annihilation spectroscopy are utilized to help quantify the damage in materials treated with short, pulsed lasers. Using a femtosecond laser on single crystal silicon, this manuscript shows that clusters of vacancy-like defects and small voids increase systematically with laser power. Lastly, the damage induced by the laser can also reach to micrometer depths.

36 MATERIALS SCIENCE↗

Thermomechanics coupling to Monte Carlo particle transport on unstructured mesh geometries using Cardinal

Geometry deformation due to thermal expansion influences neutron transport in many systems. Studying this phenomenon involves coupling models for neutronics, thermal hydraulics, and solid mechanics. To enable high fidelity modeling of these coupled physics, new capabilities were introduced in Cardinal, coupling OpenMC Monte Carlo particle transport models with MOOSE thermomechanical physics on unstructured moving-mesh geometries. In this work, we present a fully open-source capability leveraging on-the-fly mesh skinning to automatically regenerate OpenMC geometry, which allows multiphysics feedback from temperature, density, and geometry changes. The new capability is verified using an analytic benchmark slab problem, which couples S 2 neutron transport with thermal conduction, convective boundary conditions, Doppler-broadened cross sections, and nonlinear thermal expansion effects along the heated slab. Cardinal reproduces the analytic solutions for the neutron flux, heating, k eff , and temperature with demonstrated convergence in various error terms including mesh resolution and cross section temperature library spacing. For the nominal benchmark conditions and with a fine mesh, maximum relative errors for neutron flux, temperature, and heating are lower than 1%, while errors in integral quantities such as k eff and slab length are within 1 pcm and 48 µm, respectively. This work (i) presents a new numerical approach to thermomechanics coupling with OpenMC models, (ii) is the first (to our knowledge) to utilize a mechanical partial differential equation (PDE) solution to solve the (Griesheimer and Kooreman, 2022) analytic benchmark, and (iii) develops this verified capability within an open-source package.

97 - MATHEMATICS AND COMPUTING↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

The Primary Interaction Compton Couple algorithm for sorting GRETINA/GRETA interaction points

The Primary Interaction Compton Couple (PICC) algorithm is presented in this work. The algorithm is used to determine the first-interaction-point position for $γ$-ray events in GRETINA. The first-interaction-point position is crucial for in-beam $γ$-ray spectroscopy experiments with fast beams due to the effect of Doppler broadening on the in-beam energy resolution. The development of the algorithm and its performance compared to a tracking algorithm and the Main Interaction assumption is presented. The PICC algorithm is demonstrated with real data to outperform the $γ$-ray energy tracking algorithm used for comparison here and the Main Interaction assumption in first-interaction-point determinations.

GRETINA↗

Status of GPU capabilities within the Shift Monte Carlo radiation transport code

Shift is a general-purpose Monte Carlo (MC) radiation transport code for fission, fusion, and national security applications. Shift has been adapted to efficiently run on GPUs in order to leverage leadership-class supercomputers. This work presents Shift’s current GPU capabilities. These include core radiation transport capabilities for eigenvalue and fixed-source simulations, and support for non-uniform domain decomposition, Doppler broadening, free-gas elastic scattering, general-purpose geometry, hybrid MC/deterministic transport, and depletion. Transport results demonstrate a 2–5× GPU-to-CPU speedup on a per-node basis for an eigenvalue problem on the Frontier supercomputer and a 28× speedup for a fixed-source problem on the Summit supercomputer.

Biondo, Elliott [ORNL] (ORCID:0000000290881360)↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory tests of CO2 laser collective Thomson scattering for measurements of ion temperature in the divertor

Collective Thomson scattering (CTS) is a diagnostic method that measures the ion velocity distribution of a plasma. CO2 laser CTS measurements are challenging because of the inherently small Doppler broadening and scattering signals that are difficult to detect. We implemented a heterodyne detection scheme to measure spectrum changes of less than a GHz. To maximize the collected light at small scattering angles, we designed a unique light collection approach consisting of a customized conical-shaped (axicon) lens with a hole in the center. The axicon lens is used to collect the scattered light emitted within an annular cross-section from the scattering volume while the probe beam is passed through the hole at the center of the lens. The performance of the heterodyne detection scheme and annular collection approach was demonstrated using a Transverse Excited Atmospheric pressure CO2 laser with a pulse energy of 160 mJ at λ = 10.59 µm.

Instruments & Instrumentation↗

Design study of an edge current density diagnostic using new high-performance single-channel beam emission spectrometers at DIII-D

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Further, light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny–Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.