Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Detection of gravity-induced polarity of cytoplasmic streaming in Chara

Gravity induces a polarity of cytoplasmic streaming in vertically-oriented internodal cells of characean algae. The motive force that powers cytoplasmic streaming is generated at the ectoplasmic/endoplasmic interface. The velocity of streaming, which is about 100 micrometers/s at this interface, decreases with distance from the interface on either side of the cell to 0 micrometers/s near the middle. Therefore, when discussing streaming velocity it is necessary to specify the tangential plane through the cell in which streaming is being measured. This is easily done with a moderate resolution light microscope (which has a lateral resolution of 0.6 micrometers and a depth of field of 1.4 micrometers), but is obscured when using any low resolution technique, such as low magnification light microscopy or laser Doppler spectroscopy. In addition, the effect of gravity on the polarity of cytoplasmic streaming declines with increasing physiological age of isolated cells. Using a classical mechanical analysis, we show that the effect of gravity on the polarity of cytoplasmic streaming cannot result from the effect of gravity acting directly on individual cytoplasmic particles. We suggest that gravity may best be perceived by the entire cell at the plasma membrane-extracellular matrix junction.

Non-NASA Center↗

Solar Contamination in Extreme-precision Radial-velocity Measurements: Deleterious Effects and Prospects for Mitigation

Solar contamination, due to moonlight and atmospheric scattering of sunlight, can cause systematic errors in stellar radial velocity (RV) measurements that significantly detract from the ~10 cm/s sensitivity required for the detection and characterization of terrestrial exoplanets in or near habitable zones of Sun-like stars. The addition of low-level spectral contamination at variable effective velocity offsets introduces systematic noise when measuring velocities using classical mask-based or template-based cross-correlation techniques. Here we present simulations estimating the range of RV measurement error induced by uncorrected scattered sunlight contamination. We explore potential correction techniques, using both simultaneous spectrometer sky fibers and broadband imaging via coherent fiber imaging bundles, that could reliably reduce this source of error to below the photon-noise limit of typical stellar observations. We discuss the limitations of these simulations, the underlying assumptions, and mitigation mechanisms. We also present and discuss the components designed and built into the NEID (NN-EXPLORE Exoplanet Investigations with Doppler spectroscopy) precision RV instrument for the WIYN 3.5m telescope, to serve as an ongoing resource for the community to explore and evaluate correction techniques. We emphasize that while “bright time” has been traditionally adequate for RV science, the goal of 10 cm/s precision on the most interesting exoplanetary systems may necessitate access to darker skies for these next generation instruments.

Arpita Roy↗

The NEID Port Adapter at WIYN: On-Sky Fast Guiding Performance

NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy) is an optical, fiber-fed spectrometer installed on the WIYN 3.5m Telescope. The radial velocity precision that NEID is expected to reach requires the stellar jitter (i.e., the slight irregular movement of the stellar image induced by atmospheric turbulence, wind-shake, etc.) to be controlled within 0.05 arc-seconds 90% of the time in nominal observing conditions (i.e., 0.8-arcsecond seeing and mild winds). To achieve that, the NEID Port Adapter incorporates a fast, first-order wavefront correction system, which implements an Electron-Multiplying CCD camera and a tip/tilt piezo stage to capture and stabilize the stellar image. Here, we use on-sky data to demonstrate the performance of this system under various observing conditions.

Dan Li↗

Doppler-Free Saturation Spectroscopy (DFSS) for Magnetic and Electric Field Measurements in an FRC plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on a feasibility study of Doppler-free saturation spectroscopy (DFSS) as a diagnostic strategy to measure the internal magnetic and electric fields of TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic and electric fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening linewidths and reveal Zeeman/Stark split hyperfine structures of target emission lines. The collaboration involved the use of ORNL’s suite of experimentally validated quantum mechanical modelling codes to simulate theoretical atomic spectra for a variety of machine parameters and laser beam configurations. TAE’s expertise was heavily used to provide measurements/models of the required machine parameters needed as inputs to the simulations. Results of an all-encompassing error analysis demonstrate the favourable capabilities of the diagnostic and provided invaluable insights as to how DFSS can be best used to accurately measure internal B/E-fields in C-2W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a Doppler-Free Saturation Spectroscopy (DFSS) Diagnostic for Helicon Wave Electric Field Vector Measurement in Edge Plasma in DIII-D

A laser-based technique known as Doppler-free saturation spectroscopy (DFSS) has been designed, fabricated, and installed on the DIII-D National Fusion Facility to measure the helicon wave electric field vector in the edge plasma. These experimental measurements quantify phenomena resulting in decreased current drive efficiency due to wave/edge plasma interactions. This implementation of DFSS on DIII-D is the first of its kind on a tokamak and thus presents unique engineering challenges, including integration of the system onto an existing multidiagnostic port flange without impacts to system serviceability, as well as maintaining precise laser alignment over a 2-m distance during disruptions and thermal drift of the vessel. Further, these challenges were resolved using innovative design approaches such as a novel decoupled shutter system to facilitate serviceability of the in-vessel mirror assemblies without the need for personnel vessel entry, as well as an ex-vessel piezo-mirror-based optical system for laser beam shaping and real-time steering of the measurement location. The solutions to these engineering challenges were demonstrated during the successful installation and operation of these diagnostic components during the 2022 DIII-D vent and subsequent experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of electric and magnetic fields from spectral data using machine learning algorithms for Doppler-free saturation spectroscopy diagnostics

The prediction of electric and magnetic field amplitudes from atomic spectral data is critical for plasma control in fusion devices such as tokamaks. Conventional approaches that rely on physics-based models are computationally expensive and unsuitable for real-time applications. In this work, we develop and benchmark three machine learning algorithms—simulation-based inference (SBI), fully connected neural networks (FCNN), and histogram-based gradient boosting regression (GBR-Hist)—to infer field intensities directly from Doppler-free saturation spectroscopy (DFSS) spectra. Synthetic datasets of spectra were generated using the EZSSS code and evaluated both with and without added Poisson noise to mimic experimental conditions. We find that SBI achieves the highest accuracy and robustness, FCNN provides a strong balance of accuracy and computational efficiency for real-time applications, and GBR-Hist offers the fastest inference but is more sensitive to noise. Furthermore, these results demonstrate the potential of machine learning to accelerate DFSS analysis and enhance its utility for plasma diagnostics and control.

Doppler-free saturation spectroscopy↗

Magnetic Field Vector Measurements Using Doppler-Free Saturation Spectroscopy

Experimentally measuring the magnetic-field vector topology in low-cost fusion-concept devices will provide critical information required to optimize and accelerate the development of those concepts for economical fusion energy. The magnetic-field measurement techniques most commonly used in modern tokamaks, i.e., beam-emission spectroscopy and optical emission spectroscopy, are not suitable below 5000 Gauss due to a lack of sensitivity. To diagnose magnetic field relevant to some of the ARPA-E-supported fusion concepts (50 to 1000 Gauss), a novel approach is required. Doppler-free saturation spectroscopy (DFSS) is a pump/probe laser-based technique and has been successfully demonstrated in the laboratory to provide a magnetic-field measurement accuracy of <10 Gauss. DFSS is implemented to obtain ultra-high-resolution spectra at a localized point in space. The spectral data is then fit to the Schrödinger equation for determination of the magnetic-field vector. To obtain the magnetic-field topology, the measurement spatial location is scanned over the desired region of space by steering the DFSS pump laser beam. The goal of this project is to assemble and commission a portable DFSS diagnostic capable of 2-D magnetic-field vector measurements utilizing the Hα spectral line profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Doppler-Shifted Raman Spectroscopy Measures Flows

Technique for measuring velocity, static pressure, and translational temperature of flowing molecules by use of stimulated Raman spectroscopy demonstrated in supersonic wind tunnel at NASA Langley Research Center. Nonintrusive, accurate wind-tunnel measurements obtained without seeding flows. Optical equipment for vibration-free Raman doppler velocimetry in wind tunnel includes specially designed retrometer that reduces sensitivity of system to vibrations. This capability very valuable in aerodynamic testing and proves useful in wide variety of laboratory, industrial, and engineering applications.

Exton, Reginald J.↗

Hyperfine structure and isotope shifts of xenon measured for near-infrared transitions with Doppler-free saturated absorption spectroscopy

Hyperfine structure and isotope shifts of Xe were investigated with Doppler-free saturated absorption spectroscopy for all transitions in the 820-841 nm spectral interval. The Xe samples were commercial gases of natural isotopic abundances. The measurements were performed by employing a widely tunable narrow line Ti:sapphire laser. The hyperfine structures for 129 Xe and 131 Xe were well resolved. For the transitions with the wavelengths in vacuum near 820.860 nm and 841.150 nm also isotope shifts of the even isotopes were clearly observed. The modeling of the shapes of the observed absorption lines qualitatively reproduces experimental spectral profiles. The measured absorption peaks of the hyperfine structure and isotope shifts of Xe isotopes present characteristic spectral fingerprints for their identification. Eventually, quantitative spectral analysis will provide isotopic abundances of natural, as well as radioactive Xe gas samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular flow velocity using Doppler shifted Raman spectroscopy

Measurements of molecular flow velocity, static pressure, and translational temperature in the free-stream of a supersonic wind tunnel and behind the shock of a simple model are reviewed. Based on the free-stream demonstration using inverse Raman spectroscopy, an experiment is outlined to investigate the lee-side flow field above a swept delta wing and simulated spectra expected for the leading-edge vortex are included. The extension of the technique to hypersonic wind tunnels is also explored through the use of simulated spectra.

Exton, Reginald J.↗

Sub-Doppler tunable far-infrared spectroscopy

The first experimental observations of sub-Doppler linewidths in a cell made using tunable far-infrared radiation are reported. A double-resonance scheme has been used, combining CO2-laser infrared radiation with tunable far-infrared radiation to observe a sub-Doppler line shape in an excited vibrational state of CH3OH.

Inguscio, M.↗

Measurements of Doppler shifts by gas correlation spectroscopy

IR gas correlation spectroscopy is a sensitive technique for the measurement of small Doppler shifts in spectra. This technique also exhibits several important advantages over alternative methods in the remote sensing of stratospheric and mesospheric winds from spacecraft. Attention is presently given to laboratory tests demonstrating gas correlation spectroscopy's quantitative measurement of small Doppler shifts in spectra, whose close agreement with theoretical predictions suggests that measurements of the change in the radiant flux through a gas correlation spectrometer can be used to measure the relative velocity between gas and instrument for a moving parcel of gas.

Mccleese, D. J.↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Structural tunability and origin of two-level systems in amorphous silicon

Amorphous silicon films prepared by electron-beam evaporation have systematically and substantially greater atomic density for higher thickness, higher growth temperature, and slower deposition rate, reaching the density of crystalline Si when films of thickness greater than ~300 nm are grown at 425 °C and at <1 Å/s. Here, a combination of spectroscopic techniques provide insight into atomic disorder, local strains, dangling bonds, and nanovoids. Electron diffraction shows that the short-range order of the amorphous silicon is similar at all growth temperatures, but fluctuation electron microscopy shows that films grown above room temperature show a form of medium-range order not previously observed in amorphous silicon. Atomic disorder and local strain obtained from Raman spectroscopy are reduced with increasing growth temperature and show a nonmonotonic dependence on thickness. Dangling bond density decreases with increasing growth temperature and is only mildly dependent on thickness. Positron annihilation Doppler broadening spectroscopy and electron energy loss spectroscopy show that nanovoids, and not density variations within the network, are responsible for reduced atomic density. Specific heat and mechanical loss measurements, which quantify the density of tunneling two-level systems, in combination with the structural data, suggest that two-level systems in amorphous silicon films are associated with nanovoids and their surroundings, which are in essence loosely bonded regions where atoms are less constrained.

36 MATERIALS SCIENCE↗

Using convolutional neural networks to detect edge localized modes in DIII-D from Doppler backscattering measurements

In H-mode tokamak plasmas, the plasma is sometimes ejected beyond the edge transport barrier. These events are known as edge localized modes (ELMs). ELMs cause a loss of energy and damage the vessel walls. Understanding the physics of ELMs, and by extension, how to detect and mitigate them, is an important challenge. In this paper, we focus on two diagnostic methods—deuterium-alpha (D α ) spectroscopy and Doppler backscattering (DBS). The former detects ELMs by measuring Balmer alpha emission, while the latter uses microwave radiation to probe the plasma. DBS has the advantages of having a higher temporal resolution and robustness to damage. These advantages of DBS diagnostic may be beneficial for future operational tokamaks, and thus, data processing techniques for DBS should be developed in preparation. In sight of this, we explore the training of neural networks to detect ELMs from DBS data, using D α data as the ground truth. With shots found in the DIII-D database, the model is trained to classify each time step based on the occurrence of an ELM event. The results are promising. When tested on shots similar to those used for training, the model is capable of consistently achieving a high f1-score of 0.93. Furthermore, this score is a performance metric for imbalanced datasets that ranges between 0 and 1. We evaluate the performance of our neural network on a variety of ELMs in different high confinement regimes (grassy ELM, RMP mitigated, and wide-pedestal), finding broad applicability. Beyond ELMs, our work demonstrates the wider feasibility of applying neural networks to data from DBS diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗