Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of time-resolved photoluminescence and deep-level transient spectroscopy defect evaluations in an InAs nBn detector subjected to in situ and ex situ 63 MeV proton irradiation

Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in situ and ex situ 63 MeV proton irradiation to assess their generation and recombination dynamics. Pre-irradiation, the n-type InAs absorbing region, exhibits a steadily increasing minority carrier lifetime with increasing temperature, providing evidence that excited minority carriers may be recombining via shallow defect levels. From deep-level transient spectroscopy, two features are found between 10 and 275 K: a low temperature broad “shoulder,” which suggests emission from multiple shallow electron defect levels with energies <29 meV and a high temperature minimum occurring at ∼230 K with an activation energy of 539 meV, which suggests a defect in the barrier layer in the device. Two similar nBn detectors are then subjected to 63 MeV proton irradiation in step doses and measured between steps. One experiment is performed in situ with an nBn held at ∼10 K during dosing, and the other experiment is performed ex situ with a similar nBn held at room temperature for dosing. The ex situ dosing results in an evaluation of the defect introduction rate that is three to four times lower than in situ due to partial annealing of the proton-induced displacement damage at room temperature. The results of these two experiments are then compared with the dose-dependent recombination rate analysis, resulting in an estimated recombination defect cross section of 1.6 × 10 −13 cm 2 for the shallow shoulder defect.

Carrasco, Rigo A. [Air Force Research Laboratory (↗

Impact of 12-nm FinFET Technology Variations on TID Effects: A Comparative Study of GF 12LP and 12LP+ at the Transistor Level

Here, this article presents a comparative analysis of total ionizing dose (TID) response in GlobalFoundries’ (GF) 12 low-power (LP) and 12LP+12-nm bulk fin field effect transistor (FinFET) technologies using 10-keV X-rays. Our findings show that 12LP+ n-type transistors demonstrate higher sensitivity to TID degradation of the off-state leakage drain current compared to 12LP. Data indicate that for both 12LP and 12LP+, transistors with higher threshold voltages (VTs) exhibit lower off-state drain-source leakage postirradiation compared to transistors with lower VTs. Data consistently show that transistors with fewer fins per transistor show superior TID tolerance, in both 12LP and 12LP+ technologies. Lower VT transistors in both technologies display similar preirradiation leakage currents. On the other hand, higher VT transistors in 12LP+ show lower preirradiation leakage currents than those in 12LP, highlighting that the front-end-of-line of 12LP+ technology has been modified compared to 12LP. p-type devices in 12LP+ presented negligible degradation. Larger TID sensitivity in 12LP+ might be attributed to the implementation of dual-metal gate work functions, reduced halo doping, deeper source/drain (S/D) doping profiles, and/or 12LP+ having narrower fins compared to 12LP.

Dual-metal gate work functions↗

Comparison of Ion and Neutron Irradiations to 3 dpa at 500C in Ferritic-Martensitic Alloys

The growing global demand for energy will increasingly call upon advanced nuclear fission reactors to supply safe and reliable electricity. The structural and fuel cladding components of these reactors will be subject to extreme conditions of irradiation damage up to several hundred displacements per atom (dpa) at temperatures as high as 700°C. Ferritic-martensitic (F-M) steels are leading candidates for these challenging conditions due to their strength and dimensional stability under irradiation. In order to accelerate the process for evaluating F-M alloys, charged particles are increasingly being used to emulate neutron irradiations. Charged particle irradiations allow the possibility of conducting irradiation experiments within a shorter time period (i.e. at a rate up to 4 orders of magnitude faster) and with minimal radioactivation of the material, enabling lower cost and faster turnaround of post irradiation examination and analysis. However, the irradiation dose rate, damage cascade morphologies, and irradiation damage depth profiles all differ widely between protons, heavier ions, and neutrons. Currently, there is limited understanding of the significance of these physical differences and how they manifest in the irradiated microstructure and mechanical properties of F-M steels. The objective of this study is to evaluate charged particles as a surrogate for neutron irradiations in F-M alloys by assessing common irradiation conditions using Fe++ ions, protons, and neutrons. Keeping the temperature and dose consistent enables isolation of the effects of each irradiating particle and their respective dose rates and cascade morphologies.

Swenson, M.J.↗

E-Area Low-Level Waste Facility Inadvertent Human Intruder Limits and Doses in Support of the PA2022

This report documents the inadvertent human intruder (IHI) analysis for the E-Area Low-Level Waste Facility (ELLWF) at the Savannah River Site (SRS), near Aiken, South Carolina. This analysis supports the revised ELLWF Performance Assessment (PA), complying with the Department of Energy standard for operation of low-level waste disposal facilities (USDOE, 2017). The ELLWF is an operating waste disposal facility and is scheduled to continue accepting waste to 2065. One task of the revised PA is to establish waste inventory limits for the various disposal units at ELLWF. This is done by modeling future contaminant release and transport through applicable pathways to human receptors, comparing predicted doses per disposed curie with applicable performance measures, to obtain inventory limits which will assure that doses to receptors do not exceed performance measures. This report documents results of modeling future doses to one class of receptor, the inadvertent human intruder. It is assumed that after site closure, public knowledge of the site is lost, and IHIs will engage in activities on the ELLWF that will disrupt the closure cap, causing dose to the IHI. Following USDOE (2017), six different stylized exposure scenarios are considered, simulating activities by an IHI which could result in a radiological dose. The six scenarios are: • Acute – Basement Construction: IHI constructs a basement and encounters waste during excavation which is inadvertently mixed with clean soil and diluted. • Acute – Well Drilling: IHI drills a water well through waste and is exposed to drill cuttings mixed with clean soil that are brought to the surface. • Acute – Discovery: IHI begins constructing a basement but stops when encountering the riprap in the final closure cap and is exposed to photon radiation from unexcavated material residing in the undisturbed waste zone. • Chronic – Agriculture: Resident IHI is exposed to waste that was excavated for basement construction and mixed with native soil in the intruder’s vegetable garden. • Chronic – Post-Drilling: Resident IHI is exposed to waste from drill cuttings mixed with native soil and scattered in the garden area. • Chronic – Residential: Resident IHI is exposed to external radiation while in home located above waste with shielding provided by the concrete basement floor and any soil or engineered material remaining between the basement and waste. Dose calculations are performed using the SRNL Dose Toolkit (Aleman, 2023), following the approach of Smith et al (2019). Calculations are performed separately for 27 of the 33 disposal units (DUs) at ELLWF and are radionuclide specific. The results of the IHI analysis include: • Dose Factors: mrem per disposed curie (acute) and mrem/yr per disposed curie (chronic) for each parent radionuclide, for each DU. • Inventory Limits: in curies, for each parent radionuclide, for each DU. • Estimated Dose to IHI: mrem (acute) and mrem/yr (chronic), for each DU, given its projected closure inventory without inventory biases applied. Most DU-specific IHI inventory limits are in the range of 10 3 to 10 7 curies per nuclide. The lowest inventory limits are associated with gamma-emitters such as Sn-126, Ra-226, Th-232, and Cm-248. Radionuclides with short half-lives such as Pu-241, and nuclides which are pure beta emitters or which decay by electron capture, such as Ni-59 and Ni-63, have the highest limits. For the 27 evaluated DUs, predicted IHI doses are shown in Table ES-1. The maximum acute dose is 1.18 mrem, at ST23, much less than the DOE performance measure of 500 mrem (USDOE, 2017). The highest chronic dose is 37.2 mrem/yr at ST02, below the DOE performance measure of 100 mrem/yr. Also shown are estimated inventory sums of fractions (SOFs) at closure in 2065, for groundwater (GW) and IHI pathways. For each DU, the inventory is constrained by the GW pathway. For most DUs, the IHI SOFs are approximately 1000 times lower than the GW SOF values, and the IHI pathway does not drive risk for any disposal unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Deformation and Fracture Mechanisms in the Harvested High-Dose Baffle-Former Bolt with Stress-Corrosion Cracks Formed While in Service

This report presents the results of advanced mechanical testing conducted on miniature tensile specimens excised from an irradiated baffle-former bolt, a commercial pressurized water reactor component. The specimens were extracted from the midsection of the bolt shank, where the estimated damage dose reached 23 displacements per atom. The mechanical testing included the following tests: (1) conventional tensile testing at room temperature, augmented by digital image correlation (DIC) to enable noncontact strain measurements, and (2) in situ tensile testing within a scanning electron microscopy (SEM) instrument equipped with energy-dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD) detectors to evaluate active deformation and fracture mechanisms. Additionally, SEM fractographic analysis revealed alterations in the fracture mechanism from a predominantly ductile fracture in nonirradiated steel to a mixed fracture mode (still dominating ductile and minor cleavage spots) in irradiated specimens derived from the baffle bolts. The findings indicate a complex strain localization behavior for in-service irradiated steel specimens. Beyond conventional necking at the macro scale and defect-free channel formation at the micro scale, DIC results identified the presence of deformation bands approximately 100 μm in width. These bands consist of chains of grains exhibiting elevated local strain levels and may be considered an intermediate or mesoscale level of strain localization. These bands become discernible near the yield stress as localized hot spots, areas of elevated strain, persisting throughout most of the experiment. The formation of mesoscale deformation bands as a strain localization mechanism may exacerbate the defect-free channel formation in irradiated materials, further promoting irradiation-assisted stress corrosion crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiological Safety Analysis Computer (RSAC 7.2) Presentation

This presentation will be for the graduate seminar class for the University of New Mexico. We will discuss the Radiological Safety Analysis Computer (RSAC) version 7.2, a critical tool in radiological consequence analysis within the nuclear safety domain. We will begin with an introduction to radiological consequence analysis and the importance of dose modeling in nuclear safety, referencing key regulatory frameworks such as DOE-STD-3009 and 10 CFR 20. The presentation will provide an overview of RSAC, including its history, primary functions, and the inputs and outputs involved in its calculations. A detailed examination of RSAC's atmospheric dispersion model, based on the Gaussian plume methodology, will be presented, highlighting how meteorological factors influence the results. We will discuss the regulatory alignment of RSAC with DOE and NRC guidelines, emphasizing the assumptions required for compliance and the balance between conservative and realistic inputs. The presentation will also address the limitations and assumptions inherent in RSAC, comparing it with other consequence analysis codes like MACCS, HotSpot, and RASCAL. An example RSAC run will be demonstrated, showcasing a hypothetical accident scenario and interpreting the resulting dose calculations. Finally, we will introduce new ideas to enhance the current RSAC framework. This future work aims to provide multi-industry adaptability and integration with new dispersion models, addressing the evolving needs of DOE and NRC. The presentation will conclude with a discussion on RSAC's ongoing role in nuclear safety and the opportunities for future innovation.

computer program↗

HDG-1 Fiber Bragg grating data analysis

The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Electron Beam Irradiation for Water Treatment of Per- and Polyfluoroalkyl Substances (PFAS)

Per- and polyfluoroalkyl substances (PFAS) are widely used but are now considered a water contamination risk. Fermi National Accelerator Laboratory’s IARC group has demonstrated that passing water through electron beam radiation can destroy PFAS. This project aims to develop a process to scale the system for bulk water treatment. The key is efficient radiation usage, ensuring that all water receives only the minimum dose. Software was developed for this purpose, consisting of a computational fluid dynamics model (CFD) in COMSOL, which calculates particle trajectories through the radiation area. A MATLAB script integrates the radiation dose of these particles, and statistical analysis is performed to evaluate the radiation utilization efficiency. These models are validated with a flow test where colored dye is injected and optically tracked. Radiation dose is measured by testing under an e-beam to measure the degradation of a PFAS analog.

Mueller, Scott [Northern Illinois U.]↗

A Review of the Lawrence Livermore Nuclear Accident Dosimeter 1980s-present

A Nuclear Accident Dosimetry program is a federal requirement for all facilities that have the potential to have a criticality accident. Personnel Nuclear Accident Dosimeter (PNAD) theory and analytical procedures are driven by various scientific needs and interacting regulations. A brief history of the status of USA Department of Energy (DOE) nuclear accident dosimetry regulations, recommendations, and performance testing criteria are given. Then, the history of the Lawrence Livermore National Laboratory (LLNL) PNAD is explored, including changes in the physical dosimeter and adjustments of the analysis method through the last four decades. Finally, the performance of LLNL’s PNAD at criticality accident intercomparison training exercises since 2009 is explored. In general, reported neutron doses have been within or close to DOE-STD-1098 performance criteria while reported gamma doses have been outside of DOE-STD-1098 performance criteria. Reported total absorbed doses have varied in meeting ANSI/HPS N13.3 and ANSI/HPS N13.3 (R2019) performance criteria. Dosimetry staff retirement and turnover have left historical knowledge gaps, yet provided opportunities within the NAD program at LLNL. This review paper serves as an overview of the history and status of the NAD program. Brief technical, procedural and programmatic recommendations to improve LLNL’s NAD program are given. Technical recommendations include investigating orientation factors through modeling or empirical experimentation, investigating gamma dosimetry methods for high-dose scenarios, and exploring other dosimetric methods for simpler, quicker NAD analysis. Procedural recommendations include better documentation of conversion factor (activity-to-fluence and fluence-to-dose) derivations and spectrum uses, and updated analysis spreadsheets or simple Graphic User Interfaces for dose calculations. In conclusion, programmatic recommendations include formalized training for NAD analysts, and having multiple SMEs trained on the NAD program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Activation of Insulation in Low Power Nuclear Experiments

Nuclear experiments aim to test new designs, procedures, and materials. Similar to conventional power reactors, potential sources of worker exposure to radiation is a primary concern. One such concern is the insulation materials that are used in or near the reactor, which can often create dust when being handled. If this material receives a substantial neutron dose, then it can become activated, which can pose a health risk if inhaled or ingested. This analysis looked at the activation of, and conservative dose estimates from, industrial grade insulations that may be used in a reactor experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Safety Considerations for Advanced Material Irradiation at the Advanced Test Reactor

The Advanced Test Reactor (ATR) is a light water reactor with aluminum-clad driver fuel. A primary mission of the ATR is to support the next generation of nuclear reactors. This support necessarily requires irradiation of advanced materials such as sodium, fuel salts, and metal eutectics. Irradiation of advanced materials in the ATR environment presents a challenge when completing accident analyses and demonstrating compliance to the Safety Analysis Report (SAR). Many advanced materials have the possibility to react with the ATR protective barriers such as the cladding or primary coolant system (PCS) boundary during postulated accident scenarios. Further, molten fuel experiments fall outside of the standard regulatory framework for dose consequence analyses. ATR is currently developing new safety analysis methods to support irradiation of advanced materials. The primary considerations for this development are 1) experiment containment design requirements, 2) primary coolant system response to an experiment containment failure, and 3) dose analyses for molten fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety Considerations for Advanced Material Irradiation at the ATR

The Advanced Test Reactor (ATR) is a light water reactor with aluminum-clad driver fuel. A primary mission of the ATR is to support the next generation of nuclear reactors. This support necessarily requires irradiation of advanced materials such as sodium, fuel salts, and metal eutectics. Irradiation of advanced materials in the ATR environment presents a challenge when completing accident analyses and demonstrating compliance to the Safety Analysis Report (SAR). Many advanced materials have the possibility to react with the ATR protective barriers such as the cladding or primary coolant system (PCS) boundary during postulated accident scenarios. Further, molten fuel experiments fall outside of the standard regulatory framework for dose consequence analyses. ATR is currently developing new safety analysis methods to support irradiation of advanced materials. The primary considerations for this development are 1) experiment containment design requirements, 2) primary coolant system response to an experiment containment failure, and 3) dose analyses for molten fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of The DOME Shield Model For The NRIC Virtual Test Bed

As several advanced reactor concepts are maturing, test beds are needed to accelerate the demonstration and deployment of these advanced nuclear technologies. The National Reactor Innovation Center (NRIC) is building new or enhancing existing US Department of Energy infrastructure to support testing of components and systems. Demonstration of Microreactor Experiments (DOME) will utilize the Experimental Breeder Reactor-II (EBR-II) dome containment structure to host reactor demonstrations. A reactor supplemental shielding is needed so that DOME dose requirements are met. To accelerate the confirmatory analysis required for the reactor demonstration, the NRIC Virtual Test Bed (VTB) is developing a virtual model of the DOME shield that will be made available on the VTB public repository. This will allow developers to leverage advanced modeling and simulation tools to ensure their reactor demonstration concept will meet dose requirement and the limit concrete temperature in the shield during steady state and transient operation conditions. This paper presents the model developed for the DOME shield using open-source tools: MOOSE heat transfer module, Monte Carlo code OpenMC, and Cardinal to calculate the DOME shield temperature distribution during steady state

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Insulation Activation and Contamination in Low-Power Experiments

Among the diverse advanced nuclear reactor concepts being developed are designs that expect to operate at much higher temperatures than conventional light-water reactors, and therefore require alternative materials for components capable of withstanding these extreme temperatures. Insulation is one such component where alternative high-temperature industrial composites are being considered. Low-power experiments can provide an opportunity for advancing our understanding of material behavior under irradiation; however, these experiments are not without occupational hazards. The focus of this paper is the potential for activation of insulating composites when exposed to neutron fluence during reactor experiments, and to discuss the subsequent contamination of the testing area. This paper will also discuss practical measures for preventing the creation and inhalation of activated particulate matter (i.e., dust), such as engineering and administrative controls and personal protective equipment. This paper evaluates the suitability of several insulation materials for use in reactor experiments based on their activation from neutron irradiation. The materials considered are Pyrogel XTE by Aspen Aerogel, Cerablanket and Kaowool by Morgan Advanced Materials, Thermo-12 Gold by Johns Manville, and Maxsil CF6-2000 by McAllister Mills. Although these materials are not yet widely used in the nuclear industry, they are common in other industries due to their thermal insulating properties. These materials produce dust while handling that can pose health and safety hazards, which could be further exacerbated by activation. The analysis presented in this paper utilizes a deterministic method developed to predict the activation source term of the provided insulation materials. The method calculates the atomic density of each element within the composites and simulates their exposure to a specified neutron flux density representative of low power experimental conditions. During the irradiation phase and throughout the extensive cooling period, neutron absorptions and nuclear decays are tracked for relevant isotopes. The residual activity within each composite is then assessed to identify the material with the lowest potential radiological hazard to workers. Dust will be created during installation and removal of insulating materials and may also be generated during the experiment. Contamination of surrounding surfaces due to dispersion is highly likely unless preventative measures are taken. The results of this analysis are used to estimate an internal dose from inhalation of activated dust, which is significantly lower than the allowable whole-body dose. However, the risk of internal exposure may increase if the dust becomes a transport vector for nuclear material. The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of these insulating materials in low-power nuclear experiments and to foster safer work environments through informed decision-making and strategic planning. This work ultimately contributes to a broader understanding of how new non-nuclear materials for advanced reactors impact the radiological safety of co-located workers, helping to ensure the responsible management of radioactive materials during installation and decommissioning activities.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Idaho National Laboratory CY 2025 National Emission Standards for Hazardous Air Pollutants Analysis, Methodology, and Results for Radionuclides

This report details calculations of potential dose—at public receptor locations surrounding the Idaho National Laboratory (INL) Site boundary and INL in-town facilities—from radionuclides reported to be in use and potentially emitted from INL facilities during calendar year (CY) 2025. All calculations were performed in accordance with the requirements of Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H). Modeling methodology, model-input parameters, and contribution to dose by facility, source, and radionuclide at the maximally exposed individual (MEI) location are also discussed. The information in this report supports the “National Emission Standards for Hazardous Air Pollutants—Calendar Year 2025 INL Report for Radionuclides” (DOE-ID 2026). During CY 2025, the estimated annual potential dose at the INL Site MEI location was 2.45E-02 mrem/yr, up from the previous year, but remaining far less than the regulatory standard of 10 mrem/yr (CFR 40 Part 61, Subpart H). Approximately 92% of the total dose to the INL Site MEI originated from Materials and Fuels Complex sources. Emissions from INL in-town facilities resulted in an estimated annual potential dose of 4.50E-03 mrem/yr to the MEI, down slightly from the CY 2024 estimated dose. Year-to-year variations in estimated annual dose can be attributed to adjustments in laboratory operations, changes to facility infrastructure, and variation in meteorological conditions.

42 - ENGINEERING↗