Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Uncertainty Analysis of Inhalation Dose Coefficients for Nuclear Incident Response

This study addressed the need to characterize variability in inhalation dose coefficients due to uncertainties in respiratory tract deposition, systemic biokinetics, and physiological parameters. A Python-based implementation of the International Commission on Radiological Protection Publication 66 Human Respiratory Tract Model was developed called the Radiological Exposure Dose Calculator (REDCAL) to propagate parameter uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Novel Platform for Evaluating Dose Rate Effects on Oxidative Damage to Peptides: Toward a High-Throughput Method to Characterize the Mechanisms Underlying the FLASH Effect

High dose rate radiation has gained considerable interest recently as a possible avenue for increasing the therapeutic window in cancer radiation treatment. The sparing of healthy tissue at high dose rates relative to conventional dose rates, while maintaining tumor control, has been termed the FLASH effect. Although the effect has been validated in animal models using multiple radiation sources, it is not yet well understood. Here, in this work, we demonstrate a new experimental platform for quantifying oxidative damage to protein sidechains in solution as a function of radiation dose rate and oxygen availability using liquid chromatography mass spectrometry. Using this reductionist approach, we show that for both X-ray and electron sources, isolated peptides in solution are oxidatively modified to different extents as a function of both dose rate and oxygen availability. Our method provides an experimental platform for exploring the parameter space of the dose rate effect on oxidative changes to proteins in solution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simple thermal vapor deposition process for and characterization of n-type indium oxysulfide thin films

The search continues for alternative nontoxic n-type electron transport layers in optoelectronic thin-film devices. Indium oxysulfide, In 2 (O,S) 3 , represents one promising material for this application, especially when paired with chalcogenide absorber layers. The ternary nature of the composition allows for electrical conductivity and optical bandgap tuning by tailoring the sulfur to oxygen ratio in the oxysulfide alloy. However, thin films of In 2 (O,S) 3 are typically deposited only by chemical bath deposition or plasma-enhanced atomic layer deposition. Here we report deposition of thin films of In 2 (O,S) 3 in a custom-built thermal reactor using only water vapor and hydrogen sulfide as the coreactants. This advance is enabled by the use of a recently reported, highly reactive indium formamidinate precursor. As shown by x-ray photoelectron spectroscopy, the composition can be tuned from pure In 2 (O,S) 3 to pure In 2 S 3 by varying the ratio of cycles employing water or hydrogen sulfide. The oxygen to the sulfur ratio in the film can be controlled by altering the dose sequence, although films typically contain more sulfur than would be expected naively from the percentage of hydrogen sulfide doses in the deposition recipe. Rutherford backscattering spectrometry confirms the composition is sulfur-rich relative to the dosing ratio. Structural characterization indicates films are relatively amorphous in nature. Electrically, these films offer reasonably constant electron mobility at different O:S ratios, with an electron concentration tunable over 4 orders of magnitude. These oxysulfide films possess a higher indirect bandgap than their oxygen-free indium sulfide counterparts, indicating higher transmittance to blue light. These indium oxysulfide films may be suitable candidates for electron transport layers in thin-film solar cells where their wider bandgap might result in higher optical transparency and thus short circuit current density, while the tunability of their conduction band offset with an absorber layer may result in higher open circuit voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Oxidative Modifications to Short Peptides Using Low Dose Rate X-Rays

The method of X-ray footprinting and mass spectrometry (XFMS) using high flux synchrotron X-ray sources has become an established method in structural biology and is based on the radiolytic production of hydroxyl radicals, which oxidatively modify protein sidechains. While other methods of producing hydroxyl radicals are available, one benefit of using high flux density sources is that hydroxyl radical scavenging reactions can be minimized, and exposure times kept short to minimize secondary reactions. Here we present an application of the XFMS method using low dose rate X-rays from a commercial instrument. We demonstrate the feasibility of the approach using short peptides, characterizing the oxidative modifications +14, +16, and +32 Da under both aerobic and low oxygen conditions, and we additionally quantify the hydrogen peroxide production for various doses using the low dose rate source. These results provide fundamental information on the oxidative damage to peptides due to hydroxyl radicals using a low dose rate X-ray source.

X-ray methods↗

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

Xanthohumol Alters Gut Microbiota Metabolism and Bile Acid Dynamics in Gastrointestinal Simulation Models of Eubiotic and Dysbiotic States

Xanthohumol (XN), a polyphenol from hops (Humulus lupulus), exhibits antioxidant, anti-inflammatory, antihyperlipidemic, and chemo-preventive activity. Preclinical evidence suggests gut microbiota are critical to mediating some of these bioactivities. Nevertheless, its precise impact on human gut microbiota, particularly at supplemental doses, remains poorly characterized. We evaluated 200 mg/day XN for 3 weeks on human gut microbiota in a eubiotic and dysbiotic model using the Simulator of the Human Intestinal Microbial Ecosystem (SHIME®). Functional assessments of microbiota included quantification of XN metabolites, short-chain fatty acids (SCFAs), and untargeted metabolomics of the digestive metabolome. Bacterial composition was assessed by 16S rRNA gene sequencing. XN reduced alpha-diversity and short-chain fatty acid production in both models, as well as altered taxa abundance variably between models. XN disrupted bile acid metabolism through inhibition of microbial bile salt hydrolase (BSH). The modulation of bile acid metabolism has important implications for host-level bioactivity of XN.

Humulus lupulus↗

Pediatric dosing for locally acting drugs in submissions to the U.S. Food and Drug Administration between 2002 and 2020

Abstract Deriving pediatric doses for locally acting drugs (LADs) presents a unique challenge because limited systemic exposure hinders commonly used approaches such as pharmacokinetic matching to adults. This study systematically evaluated drug development practices used for pediatric dose selection of LADs approved by the U.S. Food and Drug Administration from 2002 to 2020. The three study objectives were: (1) to determine the dose selection approach for the labeled pediatric dose, (2) to examine the studied pediatric dose(s), and (3) to evaluate the characteristics of the pediatric clinical programs used to support the labeled pediatric dose. A total of 187 pediatric submissions were characterized for the labeled and studied pediatric doses of LADs. The pediatric dose was predominantly labeled as a flat dose (91%) and at a single‐dose level (67%) similar to adults. The majority (68.4%) of the submissions had the same labeled dose for pediatrics and adults. Independent pharmacodynamic/efficacy studies in pediatric patients commonly (64.2%) provided supportive evidence for the labeled pediatric dose. Inhalation, nasal, and injectable submissions had the highest number of clinical trials, lowest usage of an extrapolation of efficacy approach, and utilized diverse approaches in selecting the studied pediatric doses. This article highlights approaches for LAD dosing in pediatric patients and can be used to inform drug development of these products in the pediatric population.

Research & Experimental Medicine↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Report on Evolution of Inconel 718 Following HFIR Irradiation

The report presents the microstructure and mechanical properties of 3D printed Inconel 718 after irradiation in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) to assess its potential use as a structural material. The structural components near the outlets of several proposed reactor cores will experience significant neutron fluxes and outlet coolant temperatures ranging from the hot standby temperature of 300 °C to nearly 550 °C at the center of the part. These components must support the core in appropriate loading conditions and require structural analysis at relevant temperatures. In FY21, three heat treatments were designed and conducted to simplify the microstructure and to determine how each precipitating phase contributed to the overall strength. In FY21, baseline mechanical properties were measured from uniaxial tensile tests on subsize SS-J2 specimens at room temperature and at elevated temperatures of 300, 450, and 600 °C to serve a comparison to the irradiated properties. Four capsules containing 3D printed Inconel 718 were inserted into HFIR in FY21 for a matrix of two temperatures and two doses. The lower of the two doses was available for characterization in FY22. Multiple heat treatments of Inconel 718 irradiated to nominal conditions of 2 displacements per atom (dpa) at either 300 or 600 °C were strained with uniaxial tensile tests at the Irradiated Material Examination and Testing (IMET) Facility to discern the mechanical properties. Transmission electron microscopy was performed to correlate the observed mechanical properties with nanoscale features. The initially homogenous AM718-HM increased in strength at both irradiation temperatures based on a high density of nanometer-scale radiation-induced cavities at lower temperature and nucleation and growth of γ" precipitates at higher temperatures. The precipitate-hardened AM718-HT2 showed very small differences in strength before and after irradiation: the contribution to strength from γ" precipitates was replaced with dislocation loops. Because the radioactivity of the nickel superalloys from neutron activation limited the scope of the analysis, a feasibility study examined the possibility of an ultra-miniature specimen geometry, colloquially SS-Tiny (SS-T), for mechanical property determination using the nonirradiated Inconel 718. This study found an overestimation of ductility from the SS-T geometry with yield strength and ultimate tensile strength slightly above the SS-J2 geometry: this could be contributed to a reduction in specimen thickness.

36 MATERIALS SCIENCE↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Translating nanoparticle dosimetry from conventional in vitro systems to occupational inhalation exposures

As encouraged by Toxicity Testing in the 21st Century, researchers increasingly apply high-throughput in vitro approaches to identify and characterize nanoparticle hazards, including conventional aqueous cell culture systems to assess respiratory hazards. Translating nanoparticle dose from conventional toxicity testing systems to relevant human exposures remains a major challenge for assessing occupational risk of nanoparticle exposures. Here, we explored existing computational tools and data available to translate nanoparticle dose metrics from cellular test systems to inhalation exposures of silver nanoparticles in humans. We used the Multiple-Path Particle Dosimetry (MPPD) Model to predict deposition of humans exposed to 20 and 110 nm silver nanoparticles at 0.9 µg/m3 over an 8 hr period, the proposed a National Institute of Occupational Safety and Health (NIOSH) recommended exposure limit (REL). MPPD predicts 1.88 and 0.98 µg of silver deposited in an 8 hr period for 20 and 110 nm nanoparticles, respectively, with 20 nm particles displaying nearly 11-fold higher total surface area deposited. Peak nanoparticle concentrations occurred more proximal in the pulmonary tract compared to mass deposition patterns (generation 5 vs. generations 20-21, respectively) due to regional differences in lung lining fluid volumes. Assuming 0.4% nanoparticle dissolution by mass as previously measured, we predict peak concentrations of silver ions in cells of 0.24 and 0.17 µg/mL for 20 and 110 nm particles, respectively. Both predicted concentrations are below the measured toxic threshold of 1.7 µg/mL of silver ions in cells from in vitro assessments. Assuming 4% dissolution by mass, we predict 10-fold higher silver concentrations in tissues, peaking at 2.4 and 1.7 µg/mL, for 20 and 110 nm nanoparticles respectively, exceeding the observed in vitro toxic threshold and highlighting the importance and sensitivity of dissolution rates. Overall, this approach offers a framework for extrapolating nanotoxicity results from in vitro cell culture systems to human exposures. Aligning appropriate dose metrics from in vitro and in vivo hazard characterizations and human pulmonary doses from occupational exposures are critical components for successful nanoparticle risk assessment and worker protection and provide guidance for designing future in vitro studies aimed at relevant human exposures.

Smith, Jordan N.↗

Evaluation of Skyshine from an Accelerator Facility: Dependence on Distance and Angle

Neutron skyshine from Linac Coherent Light Source II 4 GeV electron beam operation at SLAC National Accelerator Laboratory can contribute to prompt radiation exposure to the public at distances far beyond the accelerator tunnel housing. One of the shielding design requirements at SLAC is that the annual dose to a member of the public is no more than 0.05 mSv y -1 . Our work uses Monte Carlo code FLUKA to simulate the generation of neutrons from 4 GeVelectron beam losses on a thick copper target inside a generalized geometry of the Linac Coherent Light Source II Beam Transport Hall accelerator tunnel section. The effective dose from neutron skyshine was characterized as a function of both distance from the tunnel wall (up to 1 km away) and angle relative to the beam direction (between 0° and 180°). Furthermore, this new methodology for evaluating neutron skyshine dose is applicable to high-energy GeV-range electron accelerator facilities both at SLAC and elsewhere.

43 PARTICLE ACCELERATORS↗

Biophysical Characterization of the Leukemic Bone Marrow Vasculature Reveals Benefits of Neoadjuvant Low-Dose Radiation Therapy

Although vascular alterations in solid tumor malignancies are known to decrease therapeutic delivery, the effects of leukemia-induced bone marrow vasculature (BMV) alterations on therapeutic delivery are not well known. Additionally, functional quantitative measurements of the leukemic BMV during chemotherapy and radiation therapy are limited, largely due to a lack of high-resolution imaging techniques available preclinically. This study develops a murine model using compartmental modeling for quantitative multiphoton microscopy (QMPM) to characterize the malignant BMV before and during treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Selected Area Manipulation of MoS 2 via Focused Electron Beam-Induced Etching for Nanoscale Device Editing

Here we demonstrate direct-write patterning of single and multilayer MoS 2 via a focused electron beam-induced etching (FEBIE) process mediated with the XeF 2 precursor. MoS 2 etching is performed at various currents, areal doses, on different substrates, and characterized using scanning electron and atomic force microscopies as well as Raman and photoluminescence spectroscopies. Scanning transmission electron microscopy reveals a sub-40 nm etching resolution and the progression of point defects and lateral etching of the consequent unsaturated bonds. The results confirm that the electron beam-induced etching process is minimally invasive to the underlying material in comparison to ion beam techniques, which damage the subsurface material. Single-layer MoS 2 field-effect transistors are fabricated, and device characteristics are compared for channels that are edited via the selected area etching process. The source–drain current at constant gate and source–drain voltage scale linearly with the edited channel width. Moreover, the mobility of the narrowest channel width decreases, suggesting that backscattered and secondary electrons collaterally affect the periphery of the removed area. Focused electron beam doses on single-layer transistors below the etching threshold were also explored as a means to modify/thin the channel layer. The FEBIE exposures showed demonstrative effects via the transistor transfer characteristics, photoluminescence spectroscopy, and Raman spectroscopy. While strategies to minimize backscattered and secondary electron interactions outside of the scanned regions require further investigation, here, we show that FEBIE is a viable approach for selective nanoscale editing of MoS 2 devices.

36 MATERIALS SCIENCE↗

X-Ray Induced Chemical Reaction Revealed by In Situ X-Ray Diffraction and Scanning X-Ray Microscopy in 15 nm Resolution

The detection sensitivity of synchrotron-based X-ray techniques has been largely improved due to the ever-increasing source brightness, which has significantly advanced ex situ and in situ research for energy materials such as lithium-ion batteries. However, the strong beam–material interaction arising from the high beam flux can substantially modify the material structure. The beam-induced parasitic effect inevitably interferes with the intrinsic material property, making the interpretation of the experimental results difficult and requiring comprehensive assessments. Here, we present a quantitative study of the beam effect on an electrode material Ag 2 VO 2 PO 4 using four different X-ray characterization methods with different radiation dose rates. The material system exhibits interesting and reversible radiation-induced thermal and chemical reactions, further evaluated under electron microscopy to illustrate the underlying mechanism. Further, the work will provide a guideline for using synchrotron X-rays to distinguish the intrinsic behavior from extrinsic structure change of materials induced by X-rays.

36 MATERIALS SCIENCE↗