Comparative assessment of neutron flux sensor technologies for advanced reactors

This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Correlation of As-read and As-run Dosimetry Data

The Nuclear Science Users Facilities (NSUF) is responsible for the coordination of experiments conducted in Advanced Test Reactor (ATR) by Universities and other outside organizations. Completion of the experiment and data reporting process is long and expensive. As such, it is expected that targets for temperature and neutron dosage are met. Simulations of expected reactor performance under specific conditions to meet these targets are critical for this process. However, it is not often that these reports are correlated with the data produced by monitors in ATR. This project aims to correlate simulation and read data from experiments in ATR to gauge uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Dosimetry for the SAM-2 Irradiation in ATR

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673 and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the SAM-2 irradiation which was conducted in position B8 of the ATR. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and sent to INL for loading into the SAM-2 assembly prior to irradiation. The SAM-2 experiment has 8 capsules labelled A through H designed for different exposures in successive irradiation cycles. This report is for the first three capsules, A, B and C, co-irradiated for 1 cycle. The remaining capsules and fluence monitors will be removed and analyzed after additional irradiation. Following irradiation, the fluence monitors from capsules A, B, and C were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the University of Central Florida (UCF3) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the University of Central Florida (UCF)-3 third stage experiment which was conducted in position B8 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the UCF-3 assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 8 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the GE Hitachi 16-10393 Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work (SOW) No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the GE Hitachi 16-10393 irradiation which was conducted in positions B11 of the ATR. Three other irradiations included in the SOW will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the GE Hitachi assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis. The measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the CSM assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 12 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the Boise State University JW 15-8242 Irradiation in ATR (Rev.1)

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the Boise State University (BSU) JW 15-8242 irradiations which were conducted in positions A6, A7 and A8 of the ATR. We previously reported data for this experiment after about 1 dpa in a report issued in January 2021 (1). This report is for longer irradiations to about 3 dpa. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the BSU assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

Initial Findings in Qualifying the Instrument Thimble 11 Position in the Advanced Test Reactor Critical

The Advanced Test Reactor (ATR) is a versatile nuclear research reactor located at the Idaho National Laboratory (INL) in Eastern Idaho, United States of America. It is one of the most powerful and flexible research reactors in the world and is primarily used for materials testing, isotope production and basic nuclear science research. The ATR is a light-water-cooled, beryllium-moderated reactor with a nominal thermal power capacity of 250 MW utilizing specially designed fuel, arranged in a serpentine pattern to create 9 flux traps. The special design of ATR allows for the neutron flux within each of the flux traps providing flexibility for experiments, programs and allowing experiments with different dose requirements to be irradiated simultaneously. The Advance Test Reactor Critical (ATRC) is a full-scale replica of the ATR core but is housed in a pool instead of a pressure vessel. ATRC is usually operated at less than 600 watts [1]. There are 12 dry instrument thimbles located around the outside of the core tank where a variety of measurement equipment is housed to facilitate reactor operations. Currently Instrument Thimble 11 (IT-11) is not utilized in ATR or ATRC. A range of measurements is ongoing to qualify IT-11 as a test platform for nuclear instrumentation research, development and further experimentation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IRDFF-II: A New Neutron Metrology Library

High quality nuclear data is the most fundamental underpinning for all neutron metrology applications. This paper describes the release of version II of the International Reactor Dosimetry and Fusion File (IRDFF-II) that contains a consistent set of nuclear data for fission and fusion neutron metrology applications up to 60 MeV neutron energy. The library is intended to support: a) applications in research reactors; b) safety and regulatory applications in the nuclear power generation in commercial fission reactors; and c) material damage studies in support of the research and development of advanced fusion concepts. The paper describes the contents of the library, documents the thorough verification process used in its preparation, and provides an extensive set of validation data gathered from a wide range of neutron benchmark fields. The new IRDFF-II library includes 119 metrology reactions, four cover material reactions to support self-shielding corrections, five metrology metrics used by the dosimetry community, and cumulative fission products yields for seven fission products in three different neutron energy regions. In support of characterizing the measurement of the residual nuclei from the dosimetry reactions and the fission product decay modes, the present document lists the recommended decay data, particle emission energies and probabilities for 68 activation products. It also includes neutron spectral characterization data for 29 neutron benchmark fields for the validation of the library contents. Additional six reference fields were assessed (four from plutonium critical assemblies, two measured fields for thermal-neutron induced fission on 233U and 239Pu targets) but not used for validation due to systematic discrepancies in C/E reaction rate values or lack of reaction-rate experimental data. Another ten analytical functions are included that can be useful for calculating average cross sections, average energy, thermal spectrum average cross sections and resonance integrals. The IRDFF-II library and comprehensive documentation is available online at www-nds.iaea.org/IRDFF/. Evaluated cross sections can be compared with experimental data and other evaluations at www-nds.iaea.org/exfor/endf.htm. The new library is expected to become the international reference in neutron metrology for multiple applications.

IAEA IRDFF↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Melt Wire Analyses for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Neutron fluence monitor results were reported in February 2021 in report Neutron Dosimetry for the Colorado School of Mines (CM 16-10584) Irradiation in ATR. This report presents the analyses of the melt wire capsules that were included along with the neutron fluence monitors. Each capsule was identified by the ID stamp on the bottom, then opened to assess the condition of the Pb and Zn-Al wires as well as the Bi powder. Pictures are included to illustrate the results.