Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dropwise condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Fabrication and durability characterization of superhydrophobic and lubricant-infused surfaces

Hypothesis: Practical applications of non-wetting surfaces require good mechanical durability in the wet environments for which they are intended to be used. Durability of non-wetting surfaces is influenced by the surface features, interaction with the functionalization agent, and the lubricant properties that can be tuned independently to identify optimal combination. Experiments: In this study, superhydrophobic and lubricant-infused surfaces are fabricated on copper tubes using chemical etching and electrodeposition texturing techniques, six different functionalizing agents, and five different infused lubricants. Through 180 fabrication combinations and 102 durability tests, each parameter is systematically studied for contributions to initial non-wetting behavior and its durability in heated, wet environment, under high-energy water jet impingement, and under accelerated flow conditions. Findings: Among the adsorbing and curing functionalization agents investigated, n-Hexadecyl mercaptan that belongs to the sulfhydryl group and Sylgard-184, respectively, showed high durability in heated water immersion and under jet impingement tests. For lubricant-infused surfaces, lubricants with high surface tension demonstrated high durability in heated water immersion test, whereas durability in hydrodynamic conditions is closely correlated to lubricant viscosity. Results showed that a lubricant-infused surface will maintain its non-wetting properties in dropwise condensation conditions for approximately 1.5 years.

36 MATERIALS SCIENCE↗

Advanced Anti-Fouling Coatings to Improve the Efficiency of Coal Power Plants

As the total cost of carbon to generate energy has become a global concern, operators are increasingly looking at all parts of the generation cycle to find areas where efficiency gains may be found. It has been long identified that fouling of heat exchangers is a persistent cause of up to 2.5% of global CO 2 emissions. Unfortunately, practice has also demonstrated that unless a powerful economic driver exists to encourage preemptive mitigation of fouling, there will always be a strong tendency for operators to minimize any form of intervention due to high costs and challenges in scheduling downtime. The objective of this proposed research effort was to demonstrate how existing power plants could lower their carbon emissions and significantly improve heat transfer efficiency using new surface treatment materials to control fouling in a variety of heat exchange equipment. The surface treatment material which was optimized and deployed in this effort is now known commercially as HeatX. It is a low-surface energy, water- and oil-repellent, abrasion resistant material which can be applied in-situ to a wide variety of previously worn/used/in-service substrates. Once applied, it provides a barrier against corrosion, scale deposit formation, and biofilm adhesion on the circulating water-containing tube-side. Alternatively, if applied to the tube exterior, the non-wetting nature of the surface was demonstrated to promote dropwise condensation, subsequently lowering condenser backpressure and increasing overall plant efficiency. As part of this cooperative effort, the Department of Energy’s support was crucial to de-risk and demonstrate the concept of HeatX, while validating both the performance and economic benefit in multiple pilot field studies. The HeatX material properties were optimized in this effort for full field applicability to heat exchangers and condensers, and Oceanit developed the necessary procedures and protocols to provide enough material to support extended length, multi-year demonstrations in the power generation, desalination, and refining industries, making this technology broadly applicable and ready for commercial transition. Field deployment case studies at thermal power plants have shown that the HeatX treatment can provide economic savings of up to $15,000 per day for an operator based on avoiding maintenance costs and lowering fuel usage. The complete mitigation of fouling effects can increase the efficiency of equipment by up to 7%, in a field where gains of 0.5% are generally seen as operationally significant. The HeatX treatment has also demonstrated exceptional lifetime and compatibility with a wide variety of seawater and hydrocarbon environments, further increasing both the return on investment and the effective emission reduction. Such efficiency improvements correlate to massive carbon savings. For every 1 GW of capacity, operators can see carbon emissions reductions of 300,000 tons of CO 2 per year. When looking at the bigger picture, improved condenser function across the U.S. has the potential to prevent 221.3 million tons of CO 2 emissions, equivalent to the sequestration capacity of 129 million acres of forest. If applied on a global scale, 1.26 billion metric tons of CO 2 could be averted from the atmosphere, the same amount of carbon sequestrated by 1.5 billion acres of forest annually or 262,000 wind turbines operating annually. As businesses across multiple industries take a more active role in focusing on environmental, social, and governance (ESG) solutions as part of their core business operations, HeatX will be an attractive technology for commercial investment.

01 COAL, LIGNITE, AND PEAT↗

Enhanced condensation heat transfer using porous silica inverse opal coatings on copper tubes

Abstract Phase-change condensation is commonplace in nature and industry. Since the 1930s, it is well understood that vapor condenses in filmwise mode on clean metallic surfaces whereas it condenses by forming discrete droplets on surfaces coated with a promoter material. In both filmwise and dropwise modes, the condensate is removed when gravity overcomes pinning forces. In this work, we show rapid condensate transport through cracks that formed due to material shrinkage when a copper tube is coated with silica inverse opal structures. Importantly, the high hydraulic conductivity of the cracks promote axial condensate transport that is beneficial for condensation heat transfer. In our experiments, the cracks improved the heat transfer coefficient from ≈ 12 kW/m 2 K for laminar filmwise condensation on smooth clean copper tubes to ≈ 80 kW/m 2 K for inverse opal coated copper tubes; nearly a sevenfold increase from filmwise condensation and identical enhancement with state-of-the-art dropwise condensation. Furthermore, our results show that impregnating the porous structure with oil further improves the heat transfer coefficient by an additional 30% to ≈ 103 kW/m 2 K. Importantly, compared to the fast-degrading dropwise condensation, the inverse opal coated copper tubes maintained high heat transfer rates when the experiments were repeated > 20 times; each experiment lasting 3–4 h. In addition to the new coating approach, the insights gained from this work present a strategy to minimize oil depletion during condensation from lubricated surfaces.

Adera, Solomon↗

Switchable Wettability for Condensation Heat Transfer

Condensation proceeds as dropwise or filmwise depending on the wettability of the condensing surface. These two modes of condensation have disparate heat transfer coefficients, with dropwise often exceeding filmwise. This work reports a surface with switchable superhydrophilic to hydrophobic wetting behavior that can exhibit both modes of condensation. Relative to the highly-wetting state which yields filmwise condensation, the non-wetting state exhibits dropwise condensation and twice the heat transfer coefficient. Relevance to thermal management is additionally discussed.

Heat transfer↗

Coalescence-Induced Spontaneous Shedding of Microdroplets on Superhydrophobic Surfaces Featuring Enclosed Micropillars with Hierarchical Roughness

This study investigated water vapor condensation on superhydrophobic surfaces (SHSs) featuring micropillars enclosed by wall lattices and having three-tier hierarchical roughness. A total of five samples were created with three (NW-J, W200-J and W400-J samples) having large micropillar depth (~6 μm) and two (NW-S and W200-S samples) having small micropillar depth (~1 μm). Two distinct condensate removal modes were observed during condensation: coalescence-induced jumping on samples with large micropillar depth and coalescence-induced shedding on samples with small micropillar depth. The results showed that the diameter of the shedding droplet on the W200-S sample having small micropillar depth could be as small as 107 μm, as compared to the theoretical critical diameter of 267 μm for gravitational shedding on the same sample. The enhanced functionality of the three-tier nanotextures on the W200-S sample could effectively suppress localized pinning of the three-phase contact line and Wenzel neck formation during the growth of condensate droplets. Consequently, during multidroplet coalescence, the released surface energy easily overcomes the solid–liquid adhesion, leading to spontaneous shedding of merged droplets. The inclusion of the wall lattice aids condensate growth by the droplet self-alignment along the walls and promoting coalescence. As a result, the W200-S sample exhibited the highest condensate collection as well. In conclusion, the proposed surface design has great potential for scaling up and implementation in heating, ventilation, and air-conditioning equipment due to the simplicity of the surface morphology and the facile spray-coating method used to achieve hierarchical roughness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of anti-freeze viscosity modifier for potential external tank applications

Viscosity modifiers and gelling agents were evaluated in combination with ethylene glycol and dimethyl sulfoxide water eutectics. Pectin and agarose are found to gel these eutectics effectively in low concentration, but the anti-freeze protection afforded by these compositions is found to be marginal in simulations of the intended applications. Oxygen vent shutters and vertical metallic surfaces were simulated, with water supplied as a spray, dropwise, and by condensation from the air.

Lynn, R. O. L.↗