Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic Scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ophthalmic Diagnostics Using a New Dynamic Light Scattering Fiber Optic Probe

A new fiber optic probe is developed to study different parts of the eye. The probe positioned in front of an eye, delivers a low power light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. We report alpha-crystalline size distributions, as a function of penetration depth, inside the lens and hyaluronic acid molecular size distribution in the vitreous body. In a clinical setting, the probe can be mounted on a slit-lamp apparatus simply by using a H-ruby lens holder. The capability of detecting cataracts, both nuclear and peripheral, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before surgery is necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber, e.g., posterior vitreous detachment.

Ansari, Rafat R.↗

Dynamic Light Scattering Developed to Look Through the Eye's Window Into the Body

Microgravity researcher Dr. Rafat R. Ansari, from the NASA Glenn Research Center, has found that the eye operates much like a camera and is the "window to the body." The eye contains transparent tissue through which light passes, providing us a view of what's going on inside. These transparent tissues represent nearly every tissue type that exists throughout the body. With the correlations and comparisons of these tissues done at Glenn, we hope to improve doctors' ability to diagnose diseases at much earlier stages. The medical community will be able to look noninvasively and quantitatively into a patient's eyes to detect disease before symptoms appear. Since the eye is easily accessed by light, the optical technologies created at Glenn can be used to evaluate its structure and physiology in health, aging, and disease.

Stauber, Laurel J.↗

Dynamic light scattering homodyne probe

An optical probe for analyzing a sample illuminated by a laser includes an input optical fiber operably connectable to the laser where the input optical fiber has an entrance end and an exit end. The probe also includes a first beam splitter where the first beam splitter is adapted to transmit an alignment portion of a light beam from the input fiber exit end and to reflect a homodyning portion of the light beam from the input fiber. The probe also includes a lens between the input fiber exit end and the first beam splitter and a first and a second output optical fiber, each having an entrance end and an exit end, each exit end being operably connectable to respective optical detectors. The probe also includes a second beam splitter which is adapted to reflect at least a portion of the reflected homodyning portion into the output fiber entrance ends and to transmit light from the laser scattered by the sample into the entrance ends.

Meyer, William V.↗

Molecular Rayleigh Scattering Diagnostic for Dynamic Temperature, Velocity, and Density Measurements

A molecular Rayleigh scattering technique is developed to measure dynamic gas temperature, velocity, and density in unseeded turbulent flows at sampling rates up to 16 kHz. A high power CW laser beam is focused at a point in an air jet plume and Rayleigh scattered light is collected and spectrally resolved. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. The circular interference fringe pattern is divided into four concentric regions and sampled at 1 and 16 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows for measurement of gas temperature and velocity. Independently monitoring the total scattered light intensity provides a measure of gas density. A low speed heated jet is used to validate the measurement of temperature fluctuations and an acoustically excited nozzle flow is studied to validate velocity fluctuation measurements. Power spectral density calculations of the property fluctuations, as well as mean and fluctuating quantities are presented. Temperature fluctuation results are compared with constant current anemometry measurements and velocity fluctuation results are compared with constant temperature anemometry measurements at the same locations.

Mielke, Amy R.↗

Modeling the radiant transfers of sparse vegetation canopies

The scattering dynamics of sparse vegetation canopies were studied within the framework of the three-dimensional radiative transfer model of Kimes (1984). The model was upgraded by including an algorithm for the anisotropic scattering of a soil boundary. Validation of the model was carried out using measured directional reflectance data for two canopies exhibiting typical scattering behavior with low and intermediate vegetation density. The canopies were: an orchard grass canopy; and a hard wheat canopy. A number of factors were found contributing to the final reflectance distribution of the canopies, including: (1) the strong anisotropic scattering properties of the soil; (2) the geometric effect of the vegetation probability gap function on the soil anisotropy and solar irradiance; and (3) the anisotropic scattering of vegetation which is controlled by the phase function and the layering of leaves. The application of the theoretical results to the development of earth-observing sensor systems is discussed.

Kimes, D. S.↗

Fourier plane filters

An electrically addressed liquid crystal Fourier plane filter capable of real time optical image processing is described. The filter consists of two parts: a wedge filter having forty 9 deg segments and a ring filter having twenty concentric rings in a one inch diameter active area. Transmission of the filter in the off (transparent) state exceeds fifty percent. By using polarizing optics, contrast as high as 10,000:1 can be achieved at voltages compatible with FET switching technology. A phenomenological model for the dynamic scattering is presented for this special case. The filter is designed to be operated from a computer and is addressed by a seven bit binary word which includes an on or off command and selects any one of the twenty rings or twenty wedge pairs. The overall system uses addressable latches so that once an element is in a specified state, it will remain there until a change of state command is received. The drive for the liquid crystal filter is ? 30 V peak at 30 Hz to 70 Hz. These parameters give a rise time for the scattering of 20 msec and a decay time of 80 to 100 msec.

Oliver, D. S.↗

Optical-to-optical interface device

Studies were conducted on the performance of a photoactivated dc liquid crystal light valve. The dc light valve is a thin film device that consists of two transparent electrodes, deposited on glass substrates, that enclose a thin film photoconductor (cadmium sulfide) and a thin layer of a nematic liquid crystal that operates in the dynamic scattering mode. The work was directed toward application of the light valve to high resolution non-coherent light to coherent light image conversion. The goal of these studies was to improve the performance and quality of the already existing dc light valve device and to evaluate quantitatively the properties and performance of the device as they relate to the coherent optical data processing application. As a result of these efforts, device sensitivity was improved by a factor of ten, device resolution was improved by a factor of three, device lifetime was improved by two-orders of magnitude, undesirable secondary liquid crystal scattering effects were eliminated, the scattering characteristics of the liquid crystal were thoroughly documented, the cosmetic quality of the devices was dramatically improved, and the performance of the device was fully documented.

Jacobson, A. D.↗

Almond Test Body

The invention is an almond shaped test body for use in measuring the performance characteristics of microwave anechoic chambers and for use as a support for components undergoing radar cross-section measurements. The novel aspect of this invention is its shape, which produces a large dynamic scattered field over large angular regions making the almond valuable for verifying the performance of microwave anechoic chambers. As a component mount, the almond exhibits a low return that does not perturb the measurement of the component and it simulates the backscatter characteristics of the component as if over an infinite ground plane.

Dominek, Allen K.↗

Fiber-Optic Imaging Probe Developed for Space Used to Detect Diabetes Through the Eye

Approximately 16 million Americans have diabetes mellitus, which can severely impair eyesight by causing cataracts, diabetic retinopathy, and glaucoma. Cataracts are 1.6 times more common in people with diabetes than in those without diabetes, and cataract extraction is the only surgical treatment. In many cases, diabetes-related ocular pathologies go undiagnosed until visual function is compromised. This ongoing pilot project seeks to study the progression of diabetes in a unique animal model by monitoring changes in the lens with a safe, sensitive, dynamic light-scattering probe. Dynamic light scattering (DLS), has the potential to diagnose cataracts at the molecular level. Recently, a new DLS fiber-optic probe was developed at the NASA Glenn Research Center at Lewis Field for noncontact, accurate, and extremely sensitive particle-sizing measurements in fluid dispersions and suspensions (ref. 1). This compact, portable, and rugged probe is free of optical alignment, offers point-and-shoot operation for various online field applications and challenging environments, and yet is extremely flexible in regards to sample container sizes, materials, and shapes. No external vibration isolation and no index matching are required. It can measure particles as small as 1 nm and as large as few micrometers in a wide concentration range from very dilute (waterlike) dispersions to very turbid (milklike) suspensions. It is safe and fast to use, since it only requires very low laser power (10 nW to 3 mW) with very short data acquisition times (2 to 10 sec).

Ansari, Rafat R.↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity Fluctuations in High Speed Jets

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in a high speed flow. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. An analysis is presented that established a lower bound for measurement uncertainty of about 20 m/sec for individual velocity measurements obtained in a 100 microsecond time interval. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition. The signals from three photomultiplier tubes were simultaneously recorded using photon counting at a 10 kHz sampling rate and 10 second recording periods. Density and velocity data, including distribution functions and power spectra, taken in a Mach 0.8 free jet, are presented.

Seasholtz, Richard G.↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity and Temperature

A new technique for measuring dynamic gas velocity and temperature is described. The technique is based on molecular Rayleigh scattering of laser light, so no seeding of the flow is necessary. The Rayleigh scattered light is filtered with a fixed cavity, planar mirror Fabry-Perot interferometer. A minimum number of photodetectors were used in order to allow the high data acquisition rate needed for dynamic measurements. One photomultiplier tube (PMT) was used to measure the total Rayleigh scattering, which is proportional to the gas density. Two additional PMTs were used to detect light that passes through two apertures in a mask located in the interferometer fringe plane. An uncertainty analysis was used to select the optimum aperture parameters and to predict the measurement uncertainty due to photon shot-noise. Results of an experiment to measure the velocity of a subsonic free jet are presented.

Seasholtz, Richard G.↗

Dynamic Light-Scattering Probe Used for the Very Early Detection of Cataracts and to Measure Response to Therapy (or Treatment)

Half of all blindness worldwide is due to cataracts, and 34 million Americans over the age of 65 have cataracts. This figure is expected to rise to 70 million by the year 2030. Currently, no medical treatment is available to prevent or halt the progression of a cataract; nor is there any way to reverse a cataract once it has been detected by conventional methods. The only known treatment is surgical removal of the lens. It is estimated that over $5 billion will be spent this year for the treatment of cataract patients in the United States alone. According to Carl Kupfer, M.D., former Director of the National Eye Institute at the National Institutes of Health, "A delay in cataract formation of about 10 years would reduce the prevalence of visually disabling cataracts by about 45 percent." However, this vision remains a dream because of the lack of objective methods that can be used to detect cataracts very early and, hence, can be used for screening potential anticataract drugs. This is about to change. The National Eye Institute and NASA entered into a formal interagency agreement in late 1996 to develop and test a dynamic light-scattering (DLS) device to detect the earliest changes due to cataract formation. The new DLS probe developed by Dr. Ansari at the NASA Glenn Research Center is several orders of magnitude more sensitive than conventional clinical systems. This ultrahigh sensitivity enables the probe to detect the onset of a cataract before it has any effect on vision and allows researchers to test the effectiveness of anticataract drugs in reversing cataracts. This device (see the following illustration) was originally designed to study transport phenomena in microgravity fluid physics experiments onboard the space shuttle orbiters and space station. It will be very useful in testing anticataract drugs to halt or reverse the progression of cataracts during longitudinal clinical trials.

Ansari,Rafat R.↗

Fluid dynamic studies on scattering aerosol and its generation for application as tracer particles in supersonic flow measurements utilizing laser Doppler velocimeter

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited oscillatory fluid velocity field and by comparing the ratio of particle velocity amplitude to the fluid velocity amplitude as a function of particle size and the frequency of oscillation. Particle velocity was measured by using a differential laser Doppler velocimeter. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. It is indicated that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗

Study of plasmasphere dynamics using incoherent scatter data from Chatanika, Alaska radar facility

Results of the study of Chatanika incoherent scatter radar data and Lockheed Palo Alto Research Laboratory satellite data are reported. Specific topics covered include: determination of the effective recombination coefficient in the auroral E region; determination of the location of the auroral oval; auroral boundary characteristics; and the relationship of auroral current systems, particle precipitation, visual aurora, and radar aurora.

Shelley, E. G.↗

New Programs Utilizing Light Scattering and Flow Imaging Techniques for Macromolecular Crystal Growth and Fluid Dynamics Studies

Dr. Phil Segre, a physicist by training, is a recent addition to the Biotech group, SD46, having joined NASA in August of 2000. Over the past two years he has been developing a laboratory for the study of macromolecular and protein crystal growth. The main apparatus for this work is a Dynamic Light Scattering apparatus, DLS, which is capable of making highly precise measurements of size distributions of both protein solutions and protein crystals. With Drs. Chernov and Thomas (USRA), he has begun a collaboration studying the affects of protein impurities on protein crystal growth and subsequent crystal quality. One of the hypotheses behind the differences between Earth and space grown protein crystals is that the absorption of harmful impurities is reduced in space due to the absence of convective flows. Using DLS measurements we are examining crystal growth with varying amounts of impurities and testing whether there is a strong physical basis behind this hypothesis. With Dr. Joe Ng of UAH he has been collaborating on a project to examine the folding/unfolding dynamics of large RNA complexes. A detailed understanding of this process is necessary for the handling of RNA in biotech applications, and the DLS instrument gives details and results beyond that of other instruments. With Prof. Jim McClymer of the University of Maine (summer faculty visitor to NASA in 2001, 2002), we have been studying the crystallization process in model colloidal suspensions whose behavior in some cases can mimic that of much smaller protein solutions. An understanding of the self-assembly of colloids is the first step in the process of engineering novel materials for photonic and light switching applications. Finally, he has begun an investigation into the physics of particle sedimentation. In addition to the DLS instrument he also has an instrument (called PIV) that can measure flow fields of fluids. The applications are to the dynamics of protein crystal motions both on earth and in low-gravity.

Source record↗

Energetics and dynamics of resonant and nonresonant scattering in strong magnetic fields

The energetics and the dynamics resulting from electron-photon resonant and nonresonant scattering in a plasma with magnetic field about 10 to the 12th G are studied in detail. Precise analytic results are obtained in the optically thin limit, and numerical results are presented for the optically thick case. For the latter, it is found that when the equilibrium temperature T(C) is determined by the cooling/heating balance due solely to cyclotron resonant scattering, the ratio of T(C) to the superstrong field B remains fairly constant for N(e) up to about 6 x 10 to the 21st electrons/sq cm. This line-dominated region comes to an end when the extra heating from the hard continuum photons becomes competitive with the line processes and drives T(C) well above the pure line value. For parameters characteristic of GB 880205, the thickness of the line-dominated region is determined to be between 10 to the 21st and 10 to the 22nd electrons/sq cm.

Lamb, Don Q.↗

Equilibrium Limit of Boundary Scattering in Carbon Nanostructures: Molecular Dynamics Calculations of Thermal Transport

It is widely known that graphene and many of its derivative nanostructures have exceedingly high reported thermal conductivities (up to 4000 W/mK at 300 K). Such attractive thermal properties beg the use of these structures in practical devices; however, to implement these materials while preserving transport quality, the influence of structure on thermal conductivity should be thoroughly understood. For graphene nanostructures, having average phonon mean free paths on the order of one micron, a primary concern is how size influences the potential for heat conduction. To investigate this, we employ a novel technique to evaluate the lattice thermal conductivity from the Green-Kubo relations and equilibrium molecular dynamics in systems where phonon-boundary scattering dominates heat flow. Specifically, the thermal conductivities of graphene nanoribbons and carbon nanotubes are calculated in sizes up to 3 microns, and the relative influence of boundary scattering on thermal transport is determined to be dominant at sizes less than 1 micron, after which the thermal transport largely depends on the quality of the nanostructure interface. The method is also extended to carbon nanostructures (fullerenes) where phonon confinement, as opposed to boundary scattering, dominates, and general trends related to the influence of curvature on thermal transport in these materials are discussed.

Haskins, Justin↗