Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic strain aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

Temperature-Dependent Effects on the Mechanical Behavior and Deformation Substructure of Haynes 188 Under Low-Cycle Fatigue

The mechanical behavior of a cobalt-nickel-chromium-tungsten superalloy, Haynes 188, is being critically examined at the NASA Lewis Research Center. This dynamic, strain-aging (DSA) alloy is used for combustor liners in many military and commercial aircraft turbine engines and for the liquid oxygen posts in the main injectors of the space shuttle main engine. Its attractive features include a good combination of high monotonic yield and tensile strength, and excellent fabricability, weldability, and resistance to high-temperature oxidation for prolonged exposures.

Source record↗

Recent advances in elastomer service-life prediction

The mechanical properties of an elastomer, including rupture and its time dependence, are defined uniquely by a tensile property surface in normalized stress-strain-time coordinates. In practice, the property surface is determined from short-time constant strain-rate uniaxial tests. By using the time reduction properties of both temperature and cross-link density, an effective time scale of over ten decades of log time can be covered. Changes in cross-link density, filler content, or swelling do not affect the limits of the property surface when plotted in logarithmic coordinates but merely shift their positions. The shape, however, may be modified in certain cases. The service life of an elastomer in the absence of aging reactions can be estimated from the property surface and expected in-use conditions such as strains (static or dynamic).

Landel, R. F.↗

Degradation of Coflon in Methanol at Temperatures Around 140 C

An unexpected and significant physico-chemical degradation of Coflon PVDF specimens was observed at the end of 1994 during routine scheduled exposure exercises on strained material. The intent was to age various samples, including some strained in a 4-point bend configuration, in methanol at 140 C and subsequently submit the aged samples to various tests including dynamic fatigue and fracture toughness. However, the samples deteriorated to such an extent that such testing was not possible: only when conditions were made less severe was it found possible to perform such testing. The purpose of the current report is to describe the nature of the PVDF deterioration observed during a number of tests performed to examine this phenomenon. This report also records, as Appendix 1, some SEM/X-ray microanalysis data on Coflon samples exposed to a methanol/amine mixture, and to other amine or H2S-aged samples.

Campion, R. P.↗

Longtime Durability of PMR-15 Matrix Polymer at 204, 260, 288, and 316 C

Isothermal weight loss studies at the Glenn (Lewis) Research Center were conducted at four temperatures (204, 260, 288, and 316 C) with specimens of varied geometric shapes to investigate the mechanisms involved in the thermal degradation of PMR-15. Both neat resin behavior and composite behaviors were studied. Two points of interest in these studies are the role(s) of oxygen in the mechanisms involved in the thermo-oxidative degradation of these composite materials and the dimensional changes that occur during their useable lifetime. Specimen dimensional changes and surface layer growth were measured and recorded. It was shown that physical and chemical changes take place as a function of time and location in PMR-15 neat resin and composites as aging takes place in air at elevated temperatures. These changes initiate at the outer surfaces of both materials and progress inward following the oxygen as it proceeds by diffusion into the central core of each material. Microstructural changes cause changes in density, material shrinkage (strains), glass transition temperature, dimension, dynamic shear modulus, and compression properties. These changes also occur slowly dividing the polymer material into two distinct parts: a visibly undamaged core section between two visibly damaged surface layers. The surface layer has a significant effect on compression properties of thinner specimens, but the visibly undamaged core material controls these properties for specimens having eight or more plies. It was demonstrated that there are three different mechanisms involved in the degradation of PMR-15 during aging at elevated temperatures. These are a weight gain, a small weight fraction bulk material weight loss, and a large mass fraction weight loss concentrated at the surface of the polymer or composite. At the higher temperatures (260 C and above), the surface loss predominates. Below 260 C, the surface loss and the bulk core loss become more equivalent. Between 175 and 260 C, the initial weight change is due to a weight gain mechanism with a visible lifetime that diminishes as the aging temperature increases.

Bowles, Kenneth J.↗

Micro-measurements of mechanical properties for adhesives and composites using digital imaging technology

The need for a constituent based durability or accelerated life prediction procedure to be used for the engineering design of polymer matrix composites is discussed in the light of current plans for the High Speed Civil Transport (HSCT) concerns about the U.S. infrastructure (bridges, pipelines, etc.) and other technological considerations of national concern. It is pointed out that good measurement procedures for insitu resin properties are needed for both adhesives and composites. A double cantilever beam (DCB) specimen which shows promise for the easy determination of adhesive shear properties is presented and compared with measurements of strains within the bondline using a new optical digital imaging micro-measurement system (DIMMS). The DCB specimen is also used to assess damage in a bonded joint using a dynamic mechanical thermal analysis system (DMTA). The possible utilization of the same DIMMS and DMTA procedures to determine the insitu properties of the resin in a composite specimen are discussed as well as the use of the procedures to evaluate long term mechanical and physical aging. Finally, a discussion on the state-of-the art of the measurement of strains in micron and sub-micron domains is given.

Brinson, Hal F.↗

Polarization Stability of Amorphous Piezoelectric Polyimides

Amorphous polyimides containing polar functional groups have been synthesized and investigated for potential use as high temperature piezoelectric sensors. The thermal stability of the piezoelectric effect of one polyimide was evaluated as a function of various curing and poling conditions under dynamic and static thermal stimuli. First, the polymer samples were thermally cycled under strain by systematically increasing the maximum temperature from 50 C to 200 C while the piezoelectric strain coefficient was being measured. Second, the samples were isothermally aged at an elevated temperature in air, and the isothermal decay of the remanent polarization was measured at room temperature as a function of time. Both conventional and corona poling methods were evaluated. This material exhibited good thermal stability of the piezoelectric properties up to 100 C.

Park, C.↗

Investigating Additively Manufactured 17-4 PH for Structural Applications

17-4 is used regularly to manufacture force transducers particularly for wind tunnel testing. Such applications place demanding structural requirements on the transducers with static safety factors of 1.5 common and the potential for additional dynamic loads. Additive manufacturing (AM) of transducers is very appealing because of significant potential cost and time savings as well as increased design flexibility. This study looks at the processing of 17-4 powder using selective laser melting by two different facilities using their own best practices. Hot isostatic pressing (HIP) is used by both facilities as part of the thermomechanical processing following printing to explore whether it can improve the consistency of mechanical properties. Results revealed that HIP reduced average porosity of 17-4 parts and that the yield strength of parts following solutionization and aging met wrought material property targets. Strain to failure of one of the facilities parts was less than 5% compared to greater than 9% for the other facility. Inspection of failure surfaces revealed this discrepancy could be attributed to pores (2-4% area fraction) on the failure surface of the low ductility parts. Phase content varied between the facilities with one facility producing fully martensitic parts and the other containing some retained austenite. The phase content of the starting powder and a slower than air cooling rate following the final heat treatment above the austenite eutectoid temperature are likely sources of the retained austenite. Taken together these results suggest that the current state of the art in AM 17-4 processing is sufficient for many NASA force measurement applications, but that attention is required at each stage of processing to assure desired mechanical properties.

Burns, Devin E.↗

Vascular mechanics of the coronary artery

This paper describes our research into the vascular mechanics of the coronary artery and plaque. The three sections describe the determination of arterial mechanical properties using intravascular ultrasound (IVUS), a constitutive relation for the arterial wall, and finite element method (FEM) models of the arterial wall and atheroma. METHODS: Inflation testing of porcine left anterior descending coronary arteries was conducted. The changes in the vessel geometry were monitored using IVUS, and intracoronary pressure was recorded using a pressure transducer. The creep and quasistatic stress/strain responses were determined. A Standard Linear Solid (SLS) was modified to reproduce the non-linear elastic behavior of the arterial wall. This Standard Non-linear Solid (SNS) was implemented into an axisymetric thick-walled cylinder numerical model. Finite element analysis models were created for five age groups and four levels of stenosis using the Pathobiological Determinants of Atherosclerosis Youth (PDAY) database. RESULTS: The arteries exhibited non-linear elastic behavior. The total tissue creep strain was epsilon creep = 0.082 +/- 0.018 mm/mm. The numerical model could reproduce both the non-linearity of the porcine data and time dependent behavior of the arterial wall found in the literature with a correlation coefficient of 0.985. Increasing age had a strong positive correlation with the shoulder stress level, (r = 0.95). The 30% stenosis had the highest shoulder stress due to the combination of a fully formed lipid pool and a thin cap. CONCLUSIONS: Studying the solid mechanics of the arterial wall and the atheroma provide important insights into the mechanisms involved in plaque rupture.

NASA Program Biomedical Research and Countermeasur↗

Zoledronate Prevents Simulated Weightlessness-Induced Bone Loss in the Cancellous Compartment While Blunting the Efficacy of a Mechanical Loading Countermeasure

Astronauts using high-force resistance training while weightless show a high-turnover remodeling state within the skeletal system, with resorption and formation biomarkers being elevated. One countermeasure for the skeletal health of astronauts includes an antiresorptive of the bisphosphonate (BP) drug class. We asked, does the combination of an anti-resorptive and high-force exercise during weightlessness have negative effects on bone remodeling and strength? In this study, we developed an integrated model to mimic the mechanical strain of exercise via cyclical loading (CL) in mice treated with the BP Zoledronate (ZOL) combined with hind limb unloading (HU) to simulate weightlessness. We hypothesized that ZOL prevents structural degradation from simulated weightlessness and that CL and ZOL interact to render CL less effective. Thirty-two C57BL/6 mice (male, 16 weeks old, n=8/group) were exposed to 3 weeks of either HU or normal ambulation (NA). Cohorts of mice received one subcutaneous injection of ZOL (45μg/kg), or saline vehicle (VEH), prior to the start of HU. The right tibia was axially compressed in vivo 60x/day to 9N (+1200μstrain on the periosteal surface) and repeated 3x/week during HU. Left tibiae served as a within subject, non-compressed control. Ex vivo μCT was performed on all subjects to determine cancellous and cortical architectural parameters. Static and dynamic histomorphometry were carried out for the left and right tibiae to determine osteoclast- and osteoblast relevant surfaces. Further, micro damage was assessed in select groups by basic-fuchsin staining to test whether CL had an effect. For all assays, a multivariate (2x2x2) ANCOVA model was used to account for body weight changes. Additionally, for the tibiae, we incorporated a random effect for the subject (hence, a mixed model) to account for observations of both left and right tibiae within each subject. P < 0.05 was considered significant. In the cancellous compartment of the proximal tibial metaphysis, we observed a main effect from each independent variable, as determined by structural and histomorphometric assays. Specifically, as expected, ZOL showed an increase in the cancellous bone volume to total volume fraction (BV/TV, +32%) and trabecular number (+18%) compared to the VEH. As expected, ZOL decreased osteoclast surface (OC/BS) by -45% compared to VEH. Surprisingly, ZOL reduced mineralizing surface (MS/BS) and bone formation rate (BFR), indicators of osteoblast activity, by -40% and -54%, respectively, compared to VEH. Altogether, ZOL-treated mice displayed a low turnover state of remodeling in the metaphysis. In the context of skeletal aging, we speculate that ZOL prevented age-related cancellous strut loss during the experiment. As a main effect, as expected, HU decreased BV/TV by - 31% via reductions in both trabecular thickness (-11%) and number (-22%) compared to NA controls. Additionally, HU decreased MS/BS by -38% and bone formation rate (BFR) by -50% compared to NA controls. Altogether, these data are consistent with structural degradation resulting from imbalanced remodeling that favors resorption. As a main effect, CL increased BV/TV by +15% via increased trabecular thickness (+12%) compared to the noncompressed limb. As expected, CL increased MS/BS (+20%) and BFR (+24%), indicating osteoblast mineralization contributed to bone gains. These data show that CL provided an anabolic stimulus to the cancellous tissue. We observed unique interactions in ZOL*CL and HU*CL. First, ZOL prevented CL-induced increases in BV/TV and trabecular number, as compared to VEH. In the context of skeletal aging, these data suggest no added benefit from CL in the ZOL-treated mice. Interestingly, no microdamage was observed in mice that were unloaded and treated with ZOL (independent of CL). Secondly, HU prevented CL-induced increases in BFR, as compared to NA controls. These data suggest that either exercise is less effective or the kinetics of formation are slower during simulated weightlessness. Osteoclast surface was unchanged by either treatment. Thus, in contrast to exercising astronauts, these data do not suggest a high-turnover state in the metaphysis. To assess mechanical properties as a function of HU or ZOL, we tested the left femur in three-point bending ex vivo. As expected, HU decreased stiffness (-30%) compared to NA, and ZOL increased stiffness compared to VEH (+28%). Interestingly, HU increased the post-yield displacement, related to collagenous tensile loading, compared to NA (+20%). ZOL increased yield force (+11%) and ultimate force (+17%), which seems to explain the significant effect of ZOL increasing total energy (work-to-fracture, +15%), while not affecting the post yield displacement. Taken together, ZOL did not have detrimental affect on mechanical properties. Our integrated model simulates the combination of weightlessness, exercise-induced mechanical strain, and anti-resorptive treatment that astronauts experience during space missions. We conclude that Zoledronate was an effective countermeasure against weightlessness-induced bone loss, though zoledronate, as well as weightlessness, rendered exercise-related mechanical loading less effective.

bone↗

Mechanotransduction and the functional response of bone to mechanical strain

Mechanotransduction plays a crucial role in the physiology of many tissues including bone. Mechanical loading can inhibit bone resorption and increase bone formation in vivo. In bone, the process of mechanotransduction can be divided into four distinct steps: (1) mechanocoupling, (2) biochemical coupling, (3) transmission of signal, and (4) effector cell response. In mechanocoupling, mechanical loads in vivo cause deformations in bone that stretch bone cells within and lining the bone matrix and create fluid movement within the canaliculae of bone. Dynamic loading, which is associated with extracellular fluid flow and the creation of streaming potentials within bone, is most effective for stimulating new bone formation in vivo. Bone cells in vitro are stimulated to produce second messengers when exposed to fluid flow or mechanical stretch. In biochemical coupling, the possible mechanisms for the coupling of cell-level mechanical signals into intracellular biochemical signals include force transduction through the integrin-cytoskeleton-nuclear matrix structure, stretch-activated cation channels within the cell membrane, G protein-dependent pathways, and linkage between the cytoskeleton and the phospholipase C or phospholipase A pathways. The tight interaction of each of these pathways would suggest that the entire cell is a mechanosensor and there are many different pathways available for the transduction of a mechanical signal. In the transmission of signal, osteoblasts, osteocytes, and bone lining cells may act as sensors of mechanical signals and may communicate the signal through cell processes connected by gap junctions. These cells also produce paracrine factors that may signal osteoprogenitors to differentiate into osteoblasts and attach to the bone surface. Insulin-like growth factors and prostaglandins are possible candidates for intermediaries in signal transduction. In the effector cell response, the effects of mechanical loading are dependent upon the magnitude, duration, and rate of the applied load. Longer duration, lower amplitude loading has the same effect on bone formation as loads with short duration and high amplitude. Loading must be cyclic to stimulate new bone formation. Aging greatly reduces the osteogenic effects of mechanical loading in vivo. Also, some hormones may interact with local mechanical signals to change the sensitivity of the sensor or effector cells to mechanical load.

Non-NASA Center↗