Search NASA⌕ Search

SEARCH · Search NASA

Results for “ECCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Exclusive J/$\psi$ detection and physics with ECCE

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been recommended as a reference design for the proposed Electron-Ion Collider (EIC) program. Here, this paper presents simulation studies of exclusive J/$\psi$ detection and selected physics impact results in EIC using the projected ECCE detector concept. Exclusive quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. Preliminary results estimate the excellent statistics benefited from the large cross section of J/$\psi$ photoproduction and superior performance of ECCE detector concept. The precise measurement of exclusive J/$\psi$ photoproduction at EIC will help us to more deeply understand nuclear gluon distributions, near threshold production mechanism and nucleon mass structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for e → τ charged lepton flavor violation at the EIC with the ECCE detector

The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ μ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e → τ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the τ-leptons created in the DIS process ep → τX are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong τ-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e → τ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in τ identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Cost Electrochemical Compressor (ECC) Utilizing Green Refrigerants for HVAC Applications [Slides]

HVAC systems account for approximately 14 Quads or primary energy annually, or nearly 30% of all energy used in the U.S. commercial and residential buildings. Electrochemical compression (ECC) is a transformative solid-state technology and ECC based HVAC systems could result in 40% less energy use. The goal of the project was to develop the most efficient, noiseless, and most environmentally friendly cooling system based on integrating 2 (two) technologies: a) electrochemical compressors (ECC) to replace mechanical compressors for use in building heating, ventilation, and air conditioning (HVAC) applications and b) Ionic Liquid Desiccant Systems. The overall objective was to develop and build a scalable ILD/ECC-based air conditioning system operating with a COP of 4.5, with a price premium of $70 installed per kBTU/hr.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An evaluation of electrochemical concentration Cell (ECC) sonde measurements of atmospheric ozone

Using Dobson spectrophotometer measurements of total ozone as a comparison, an analysis of the electrochemical concentration cell (ECC) ozonesonde's measurement accuracy is presented. Days of conjunctive ECC-Dobson observations (from 1970 to 1976 at Wallops Flight Center) provide a set of 123 pairs of total ozone values. Sample set statistics are generated with means and standard deviations of total ozone values and differences being noted. An in-depth study of factors such as time assumptions used in calculating residual ozone, and other possible sources of errors are examined. A study of ECC ozone profiles is also presented with an evaluation of sonde measurement of seasonal trends, altitude or peak ozone concentration, and other important ozone parameters. Short-period changes in total ozone using Dobson data during the observational period are also described.

Geraci, M. J.↗

ECC ozonesonde performance at high altitudes: Pump efficiency

The ECC ozonesonde sampling behavior was examined at pressures ranging from 60 to 6 hPa with the objective of evaluating uncertainties in high altitude ozone data caused by variations in pumping efficiency. The averaged pump efficiency correction curve for a 43 sample set of 3A type ECC pumps showed a 2-3% bias from the curve provided by the manufacturer. In addition, random pump to pump variations (2 sigma) + or - were 5% at 6 hPa. These values probably represent minimum errors since the pumps were from the same production batch. A seven sample set of the newer 4A type ECC pumps was examined, with similar findings as for the 3A types.

Torres, A. L.↗

Effects of solution mass transport on the ECC ozonesonde background current

A technique is developed to measure the effective mass transport parameter for the electrochemical concentration cell (ECC) ozonesonde in order to determine the mass transport rate constant for the ECC as a function of pressure. It is shown that a pressure dependent factor in the background current originates in a convective mass transport parameter. It is determined that for atmospheric pressures greater than 100 mb the mass transport parameter is a constant, while at pressures less than 100 mb it decreases logarithmically with pressure. It is suggested that the background current correction is directly correlated to the mass transport parameter pressure dependence. The presently used background current correction, which is based on the partial pressure of oxygen, is found to lead to an overestimation of the integrated ozone value in the troposphere for the ECC ozonesonde data.

Thornton, D. C.↗

Evaluation of longitudinal double-spin asymmetry measurements in semi-inclusive deep-inelastic scattering from the proton for the ECCE detector design

The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is presented, for the combinations of lepton and hadron beam energies of 5 × 41 GeV 2 and 18 × 275 GeV 2 . The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. Furthermore, the performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector requirements and simulation results for the EIC exclusive, diffractive and tagging physics program using the ECCE detector concept

This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC’s exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark–gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detector system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirm the proposed technology and design satisfy the requirements. Further, the projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb -1 of integrated luminosity. Additionally, insights related to a potential second EIC detector are documented, which could serve as a guidepost for future development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scientific computing plan for the ECCE detector at the Electron Ion Collider

The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. Here, in this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of ECCS Acceptance Criteria and Experimental Basis Evolution Toward Fuel Fragmentation, Relocation, and Dispersal Studies

The U.S. nuclear industry is pursuing extensions of light water reactor (LWR) fuel burnup and enrichment limits to approximately 75 GWd/t and 10 wt.% 235 U to achieve economic and operational benefits. A central safety consideration in this effort is the behavior of high burnup (HBu) fuel during loss-of-coolant accidents (LOCAs), particularly fuel fragmentation, relocation, and dispersal (FFRD). Here, this work provides a historical and technical review of U.S. LOCA regulation and experimentation, clarifying how the evolution of Emergency Core Cooling System (ECCS) acceptance criteria in 10 CFR 50.46 has shaped both testing approaches and interpretations of fuel safety. The study revisits the original intent of the ECCS criteria, showing that the peak cladding temperature and equivalent cladding reacted limits were developed as surrogates to preserve a coolable geometry. The explicit inclusion of the coolable geometry criterion in the regulation was intended to emphasize the underlying safety philosophy and as a safeguard against unforeseen failure modes, an intent that remains directly relevant to modern concerns regarding FFRD. The review traces the lineage of HBu LOCA experiments to the Argonne National Laboratory furnace tests, from which subsequent programs at Studsvik, Halden, and Oak Ridge National Laboratory were derived. These tests employed a 5 °C/s heating rate inherited from early embrittlement studies, a stylized temperature history that does not represent actual LWR LOCA thermal-hydraulics. Comparison of these test conditions to pressurized water reactor large break LOCAs and separate effects data indicates that the existing HBu LOCA database may not be fully applicable to all LWR LOCA scenarios, from which a qualitative framework for applicability is proposed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance tests on the Kohmyr ECC ozone sonde

The reliability and accuracy of the Kohmyr ECC ozone sonde are determined. Emphasis is placed on establishing and testing for leak-free connections and stable pump flow rates as well as properly adjusting the pumping pressure. Calibration of the Kohmyr ECC ozone sondes and Dasibi monitors is described. Raw ordinate data and ozone connection data are presented in tabular form. The results of a linear regression treatment of the sonde-indicated ozone concentration vs. Dasibi readings for each switch position are included along with averages of the regression parameters over the six sequencing switch positions. It is suggested that sondes and Dasibi monitors be individually calibrated before flight.

Bandy, A. R.↗

The validation of LIMS ozone profiles using correlative rocket, ECC, and Dobson data sets

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment is a limb scanning infrared sounder designed to measure vertical temperature profiles and the concentrations of key chemical compounds which are important in the stratospheric ozone-nitrogen photochemistry. Preliminary ozone profiles are being intercompared with correlative rocket and balloonsonde ozone data sets as part of the Nimbus 7 LIMS data validation activity. The LIMS ozone retrievals extend from the lower mesosphere to the tropopause (or cloud-top altitudes). In this paper, preliminary statistics of comparisons of ECC (electrochemical concentration cell) ozonesonde and rocket ozone profiles with LIMS ozone profiles are presented. ECC ozonesonde data taken at times of LIMS overpasses are also used to extend the LIMS retrieval down to ground level. Each combined profile is then integrated to obtain total column ozone. These integrated results are compared to Dobson data obtained at approximately the same time and location.

Remsberg, E. E.↗

Satellite and correlative measurements of stratospheric ozone - Comparison of measurements made by SAGE, ECC balloons, chemiluminescent, and optical rocketsondes

The validity of ozone-profile data from the satellite sensor SAGE was tested in a series of correlative experiments conducted at five fixed sites between 6 deg S and 65 deg N during 1979-1980. The intercomparisons included data taken with electrochemical ozone (ECC) balloonsondes and chemiluminescent and optical rocketsondes. The average mean difference for 17 separate comparisons between the SAGE and ECC balloonsonde observations over the altitudes 18-28 km was 9.3 percent with a standard deviation of 2.8 percent. Excluding comparisons separated by greater than 500 km reduces the average mean difference to 8.9 percent and the standard deviation to 2.1 percent. The average mean difference between SAGE and three optical rocketsonde observations over the altitudes 25-50 km was 11 percent, and between SAGE and two chemiluminescent rocketsondes over the altitudes 20-60 km it was 13.5 percent. Considering the differences in vertical resolution, experimental errors, and ozone time and space gradients, the agreement between SAGE-derived ozone profiles and these correlative measurements is considered very good. In addition, isopleths of ozone mixing ratio versus latitude and altitude are in good agreement with previously published results.

Mccormick, M. P.↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of solution mass transport on the ECC ozonesonde background current

Measurement of the mass transport rate constant for the electrochemical concentration cell in an ozonesonde as a function of the pressure is reported. The investigation was performed to accurately model the residual current present in the ECC cell in the absence of ozone. The convective mass transport for two sondes were determined while maintaining a sufficiently negative cathodic potential to eliminate electron transfer at the cathode surface. A sonde was placed in a bell jar and subjected to varying pressure levels. When the background current was kept below 0.1 microamp and pressure was from 100-1000 mb, the necessary correction term for the pressure was independent of pressure. However, below 100 mb, a logarithmic decrease in the background current with pressure is expected. Present practices, involving a sensitivity to oxygen, are calculated to result in overestimation of the total ozone between 1000-10 mb by 0.0096 atm-cm with a background current of 0.1 microamp at 1000 mb.

Thornton, D. C.↗