Search NASASearch

SEARCH · Search NASA

Results for “ELECTRIC CONDUCTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrical property enhancement of non-heat-treatable wrought aluminum alloys using graphene additives

With growing efforts of electrification, aluminum’s role as a light-weight conductor material has become increasingly prominent. There is a critical need to improve the electrical performance of aluminum at room temperature and high operating temperatures. In this study, the effect of graphene nanoparticle additives on the electrical performance of a non-heat treatable alloy were (AA3003) explored. Graphene’s unusual structure and electronic properties were used to improve AA3003 properties. Here, in this work, the effects of graphene on the evolution of electrical properties and microstructural features have been explored on lab scale hot extruded AA3003-graphene composites. Hot pressing schedules and extrusion temperatures were varied to investigate changes in intermetallic dispersion characteristics in the presence of dispersed graphene. We measured a reduction of 10.3 % in the temperature coefficient of resistance in the AA3003 sample with 0.05 wt% graphene extruded at 400 °C, along with a maximum increase of 1.1 % in electrical conductivity at 20 °C. Increasing the hot-pressing times up to 8 hours was also found to consistently increase the electrical conductivity, due to increased precipitation of intermetallic phases. Despite being a non-heat treatable alloy, AA3003 displays interesting precipitation dynamics and grain recrystallization trends that can be modulated with varying levels of heat treatment, graphene concentrations, and hot extrusion process parameters.

36 MATERIALS SCIENCE

Advanced Conductor Testing – 1431 kcmil Prysmian ACSS with E3X

Advanced conductors represent a significant evolution in transmission line technology. These conductors utilize innovative materials, such as composite cores, ultra-high-strength steel, and heat-dissipating coatings, to offer improved performance compared to traditional Aluminum Conductor Steel Reinforced (ACSR) designs. However, the deployment of these technologies has so far been limited. As each conductor comes with nuances in test setup and specifications, a standard test is not readily available to apply to all advanced conductors. Idaho National Laboratory’s (INL) Advanced Conductor Testing project, sponsored by the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) and Office of Electricity (OE), focuses on developing and implementing testing protocols and plans for advanced conductor technologies to assess and demonstrate physical performance under varying operational conditions, including extreme environmental stressors such as wildfires. This report contains the fire testing results of a 1431 kcmil Prysmian ACSS with E3X conductor.

24 - POWER TRANSMISSION AND DISTRIBUTION

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY

Simplification of the Grid Model and its Impact on the Analysis of Electrical Power Systems

Here, this paper analyzes the impact of the use of Kron reduction on the state variables of a three-phase electrical system, even when it does not meet the necessary conditions for its application. Reduction is applied to a power line model to eliminate the equation corresponding to the neutral conductor of the line. The ATP program is used to model and simulate the behavior of an electrical system considering different degrees of disequilibrium as a reference for the comparison of results. The results show that under certain conditions of disequilibrium the Kron reduction can lead to significant errors in the state variables of the system.

Electric Power Systems

Uncertainty quantification for Joule heating processes in fibrous pore-resolved media

Joule heating (JH) is an energy-efficient and sustainable technique for heating materials. Its application for industrial heating, particularly, has been gaining attention due to its potential for increasing the yield of various chemical products. The process involves the use of heating elements (materials that are highly conductive electrically and thermally) to heat up other materials or substances. These conductors, however, can exhbit varying degrees of uncertainty due to non-linearities in their temperature-dependent properties, which could result in variable material behavior. In this work, we carry out uncertainty quantification (UQ) at the pore scale to describe the uncertainty of such materials. In so doing, we applied the non-intrusive polynomial chaos expansion (PCE) technique to quantify the uncertainty within the system. The steady state Joule heating equation was solved numerically at the pore scale mimicking conditions within a heating chamber for propane dehydrogenation, and various electro-thermal profiles were obtained. We also examined the effect of the number of sampling points (20 – 100) and order of the PCE coefficients (2 – 5) on the accuracy of the temperature evaluations. The results were then benchmarked with the standard Monte Carlo (MC) method. The average temperature of the 4th-order global PCE showed good agreement with the MC results (which were positively skewed). Orders greater than 4 gave an underestimation of the temperatures while predictions for the peak temperature improved as the number of sampling points increased.

Fagbemi, Samuel [ORNL] (ORCID:0000000236995025)

A high strength Al-2Ni-0.5Zr conductor alloy fabricated via laser powder bed fusion

There is a current need for new aluminum alloy design strategies to target applications requiring high strength and conductivity with reductions in mass. A new lightweight Al-2Ni-0.5Zr (wt. %) conductor alloy was fabricated using laser powder bed fusion. A design of experiments probed the alloy's solidification cracking susceptibility. It was observed that solidification cracking was generally reduced with fast scan speeds, above 1500 mm/s, and smaller hatch spacings. The different cooling rates throughout the melt pool produced a heterogeneous distribution of cellular and equiaxed Al 3 Ni precipitates in the as-printed alloy. Additionally, the rapid solidification characteristic of laser powder bed fusion created a super-saturated Zr solid solution. An aging heat treatment at 375 °C for 24 h imparted strengthening through the precipitation of L1 2 -Al 3 Zr nanoprecipitates, which counteracted the softening caused by the fragmentation and coarsening of Al 3 Ni precipitates. The yield strength increased from 138 MPa in the as-printed condition to 168 MPa after aging, while the ductility remained constant at ∼21%. The aging treatment simultaneously increased the electrical conductivity from 40.8% IACS (International Annealed Copper Standard) to 53.5% IACS. Modeling of the strengthening mechanisms and electrical conductivity contributions rationalized the simultaneous increase in strength and conductivity upon aging. Furthermore, the strengthening efficacy of the Al 3 Ni and L1 2 -Al 3 Zr precipitates, combined with the low Ni and Zr solubility in the FCC Al matrix, facilitated both high strength and electrical conductivity. Overall, the combination of strength and electrical conductivity positions this alloy as a suitable choice for additively manufactured lightweight conductors.

Additive manufacturing

Critical Role of Framework Flexibility and Disorder in Driving High Ionic Conductivity in LiNbOCl 4

Understanding Li-ion transport is key for the rational design of superionic solid electrolytes with exceptional ionic conductivities. LiNbOCl 4 is reported to be one of the most highly conducting materials in the recently realized new class of soft oxyhalide solid electrolytes, exhibiting an ionic conductivity of ~11 mS·cm -1 . Here, we apply X-ray/neutron diffraction and pair distribution function analysis - coupled with density functional theory/ab-initio molecular dynamics - to determine a structural model that provides a rationale for the high conductivity that we observe experimentally in this nanocrystalline solid. We show that it arises from unusually high framework flexibility at room temperature. This owes to isolated 1-D [NbOCl 4 ] - anionic chains which exhibit energetically favorable orientational disorder that is - in turn - correlated to multiple, disordered and equi-energetic Li + sites in the lattice. As the Li-ions sample the 3-D energy landscape with a fast predicted diffusion coefficient of 5.1 x 10 -7 cm 2 /s at room temperature (σ i calc = 17.4 mS·cm -1 ), the inorganic polymer chains can reorient or vice versa. The activation energy barrier for Li migration through the frustrated energy landscape is especially reduced by the elastic nature of the NbO 2 Cl 4 octahedra evident from very widely dispersed Cl-Nb-Cl bond angles in AIMD snapshots at 300 K. The phonon spectra are predominantly influenced by Cl vibrations in the low energy range, and there is strong overlap between the framework (Cl, Nb) and Li partial pDOS in the region between 1.2 - 4.0 THz. The framework flexibility is also reflected in a relatively low bulk modulus of 22 GPa. In conclusion, our findings pave the way for investigation of future “flex-ion” inorganic solids and open up a new direction for the design of high conductivity, soft solid electrolytes for all-solid-state batteries.

AIMD

Precise 2D electric field density simulations for superconducting quantum devices

Dielectric loss due to two-level systems is a limiting factor for superconducting qubit relaxation times. These losses arise mostly from nanometer-scale interfacial defect regions in superconducting devices with planar dimensions of microns to millimeters, thus making it resource intensive to accurately simulate the electric field density in these regions with traditional electromagnetic solvers. In this work, we demonstrate a fast boundary integral equation solver that allows precise simulation of electric field density in these thin regions, showing a speedup of around two orders of magnitude over traditional solvers, with relative errors around $10^{-7}$ for a ten-minute solution runtime. By computing participation ratios through Green's first identity without squaring the electric field, our approach is less susceptible to the field singularities near conductor corners. We apply this solver to a basic untrenched coplanar waveguide cross-section, showing that the common assumption of participation ratio linearity with dielectric constant holds well for some interfaces and not others; in particular, while the metal-air (MA) top and corner follow this linear relationship strongly, the MA sidewall does not. We then compare isotropic and anisotropic etching, showing that the MA sidewall and the metal-air-substrate triple junction are the most strongly affected. We are currently leveraging this solver to explore geometries that will uniquely isolate the participation ratios of the different dielectrics. Finally, we are working to combine this solver framework with a full 3D microwave solver to accurately calculate participation ratios for the thin dielectrics that are known sources of loss in superconducting qubits.

Gimbutas, Z. [NIST, Boulder] (ORCID:00000003320982

Preliminary Design of Ironless Linear Induction Motors for ITER MSE Shutter Actuators

In this article, the shutters need to be closed or opened during the operation and calibration period time for the fusion diagnostic systems, such as the International Thermonuclear Experimental Reactor (ITER) motional stark effect (MSE). Standard electric motors and actuators will not work in a strong magnetic field environment due to the presence of the magnetic field of fusion reactors. The innovative linear induction motor (LIM) with an ironless feature overcomes this kind of challenge and can be used for any application that requires controlled motion with a large stroke in the magnetic field environment. It consists of a high-electrical conductivity plate like copper and three-phase motor windings with nonferrous or stainless-steel stators. The conductor plate attached with the shutter is simply driven by the underneath three-phase linear windings to achieve linear motion. The motor drive can be controlled remotely by a controller using the electrical connection, so no sensitive electronic components are located in the harsh environment where the motor itself is located. The design requirements and test facility have been described. Several 3-D transient Maxwell electromagnetic (EM) models with different locations of three-phase linear motor windings and shutter stators have been analyzed and evolved to meet any applications allowed in the harsh environment inside the vacuum vessel of fusion reactors. The preliminary design results are presented in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Pyrochlore-type lanthanide titanates and zirconates: Synthesis, structural peculiarities, and properties

This contribution provides a thorough examination of the structural characteristics of pyrochlore-type lanthanide titanates and zirconates Ln2Ti2O7 and Ln2Zr2O7, across various length scales. This paper also examines their processing, interesting physical properties (electrical, magnetic, and thermal characteristics), and responses to high pressure and ion irradiation. Brief sections on the elemental oxides' crystal chemistry, pertinent phase diagrams, and energetics of defect formation are also provided. Pyrochlore-type Ln2Ti2O7 and Ln2Zr2O7 stand out as truly multifunctional materials. Moreover, they have emerged as fascinating materials due to magnetic geometrical frustration, arising from the ordering of magnetic Ln3+ and non-magnetic Ti4+ (or Zr4+) cations into separate, interpenetrating lattices of corner-sharing tetrahedra. This results in a diverse array of exotic magnetic ground states, such as spin-ice (e.g., Dy2Ti2O7 or Ho2Ti2O7) or quantum spin ice (e.g., Tb2Ti2O7), observed at both low and room temperatures. They also exhibit varied electrical and electrochemical characteristics. Some members such as Gd2Zr2O7, function as fast ion conductors with a conductivity (σ) of ≈10−2 S·cm−1 at 800 °C and activation energy (Ea) ranging from 0.85 to 1.52 eV, depending on the degree of structural disorder. Others, such as Gd2TiMoO7, are mixed ionic-electronic conductors with σ ≈ 25 S·cm−1 at 1000 °C, making them promising candidate materials for applications in energy conversion and storage devices and oxygen separation membranes. Their exceptionally low thermal conductivity (e.g., κ ∼ 1.1–1.7 W·m−1·K−1 between 700 and 1200 °C for Ln2Zr2O7), close to the glass-like lower limit of highly disordered solids, positions them as valuable materials for thermal barrier coatings. They can also effectively accommodate actinides (e.g., Pu, Np, Cm, Am) in solid solutions and sustain prolonged exposure to radiation due to alpha-decay events, while preserving the integrity of the periodic atomic structure. Proposed as major components in actinide-bearing ceramics, they contribute to the long-term immobilization and disposal of long-lived waste radionuclides from nuclear programs. Some of these properties are displayed simultaneously, opening avenues for new applications. Despite the wealth of data available in the literature, this review highlights the need for a better understanding of order/disorder processes in pyrochlore-type materials and the influence of the structural length scale on their physical and chemical properties. Recent experimental evidence has revealed that pyrochlore short-range structure is far more complex than originally thought. Moreover, pyrochlore local structure is now believed to include short-range, lower symmetry, ordered domains, such as the orthorhombic weberite-type of structure. Notably, short- and long-range structures appear decoupled across different length scales and temperature regimes, and these differences persist even in well-ordered samples. We believe that the pyrochlore structure offers a unique opportunity for examining the interplay between chemical composition, defect chemistry, and properties. In Memoriam: Rodney C. Ewing, Fondly Remembered.

Physics

Informing Transmission Supply Chain Needs from National Transmission Studies

Recent national studies indicate significant transmission expansion can provide the lowest-cost option to maintain grid reliability while meeting growing demand. However, constraints in domestic supply chains may limit grid expansion across the U.S., with higher costs and longer delays for required transmission equipment. Despite growing evidence of supply chain constraints for transmission components, transmission planning studies often assume transmission equipment is readily available for deployment or analyze future demand using historical trade and manufacturing data that may not capture evolving grid needs. This report aims to address this gap by demonstrating methods to quantify future demand for critical transmission components and input materials from national-scale planning models. These components include power transformers, generator step-up transformers, converter transformers, conductors, circuit breakers, and transmission towers and the materials include aluminum, steel, grain-oriented electrical steel (GOES), and copper. The analytical approach is applied to two nodal transmission expansion scenarios from the National Transmission Planning Study (NTP) to illustrate the methods. These scenarios represent different transmission expansion strategies for the contiguous U.S. to the year 2035: the Alternating Current (AC) scenario includes AC transmission expansion within each interconnection and the Multiterminal (MT) scenario includes interregional transmission expansion across the country using both AC and multiterminal HVDC options between neighboring zones. We also explore potential heuristics to derive transmission component demand from zonal capacity expansion models (CEMs) with coarse representation of the transmission grid.

24 POWER TRANSMISSION AND DISTRIBUTION

Informing Transmission Supply Chain Needs from National Transmission Studies

Recent national studies indicate significant transmission expansion can provide the lowest-cost option to maintain grid reliability while meeting growing demand. However, constraints in domestic supply chains may limit grid expansion across the U.S., with higher costs and longer delays for required transmission equipment. Despite growing evidence of supply chain constraints for transmission components, transmission planning studies often assume transmission equipment is readily available for deployment or analyze future demand using historical trade and manufacturing data that may not capture evolving grid needs. This report aims to address this gap by demonstrating methods to quantify future demand for critical transmission components and input materials from national-scale planning models. These components include power transformers, generator step-up transformers, converter transformers, conductors, circuit breakers, and transmission towers and the materials include aluminum, steel, grain-oriented electrical steel (GOES), and copper. The analytical approach is applied to two nodal transmission expansion scenarios from the National Transmission Planning Study (NTP) to illustrate the methods. These scenarios represent different transmission expansion strategies for the contiguous U.S. to the year 2035: the Alternating Current (AC) scenario includes AC transmission expansion within each interconnection and the Multiterminal (MT) scenario includes interregional transmission expansion across the country using both AC and multiterminal HVDC options between neighboring zones. We also explore potential heuristics to derive transmission component demand from zonal capacity expansion models (CEMs) with coarse representation of the transmission grid.

24 POWER TRANSMISSION AND DISTRIBUTION

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY

An alternative electrode design for accurate spectral induced polarization measurements in variably saturated porous media

SUMMARY Applications of spectral induced polarization (SIP) require electrodes that maintain hydrologic contact with surrounding soils to capture small electrical responses, often observed as phase shifts in milliradians. For unsaturated soils, electrodes must overcome increased electrical contact impedance due to reduced pore fluid. Traditional designs use a ceramic membrane electrode (CME) with a water reservoir and metal conductor, requiring periodic maintenance to retain electrolytic solution. For field applications where maintenance is impractical, alternative designs are needed. This study evaluated a new electrode design (silica flour electrode, SFE) alongside a CME. SFEs use packed silica flour to store water via capillary forces against a metal conductor. This study examined both designs in three variably saturated soils at soil suctions up to 700 mbar and soil water contents below 1 percent, with SIP measurements across 0.01 to 10 000 Hz frequencies. SFEs match CMEs at high frequencies and perform better at lower frequencies, without requiring ongoing maintenance, making them ideal for field use. In water-only experiments, CMEs produced errors and high noise below 1.5 Hz, whereas SFEs were more accurate. However, CMEs performed better above 300 Hz. In fine sand, SFEs performed better due to the relatively lower contact impedance as compared to CMEs. Both electrode types performed comparably in silty sand and silt loam soils, although CMEs required ongoing maintenance, suggesting potential for long-term reliability issues.

58 GEOSCIENCES

PLC Integration for the Horn A Magnetic Field Mapping Device

This presentation summarizes the integration of a programmable logic controller (PLC) into the Horn A magnetic field mapping device for the Long-Baseline Neutrino Facility (LBNF). The device is used to position magnetic field probes along the centerline of the Horn A inner conductor to verify that the magnetic field within this region is approximately zero. The presentation covers the PLC hardware and electrical integration, stepper motor and encoder control, ladder logic development, mechanical integration, and system testing. Results include successful bidirectional motion and encoder feedback for the translation and rotation axes, as well as characterization of translational motion for repeatable probe positioning.

Bitakis, Kayla [Unlisted, US, IL]

Advanced Transmission Technologies – GETs and HPCs Session 1: ATT Foundations and Dynamic Line Ratings (DLRs)

The INL TADA GETs Cohort Session 1, held on November 4, 2025, convened experts to address the integration of advanced transmission technologies, including Grid-Enhancing Technologies (GETs) and High Performance Conductors (HPCs), with a focus on digital assurance challenges. The session highlighted the growing importance of cybersecurity, supply chain transparency, reliability, and business risk management in deploying GETs, especially Dynamic Line Ratings (DLRs). Participants examined how expanded attack surfaces, limited vendor pools, and new regulatory requirements—such as FERC Orders 881, 2023, and 1920—are influencing utilities and technology providers. The workshop underscored the need for cyber-informed engineering, secure-by-design principles, and practical risk management strategies, while fostering collaboration and knowledge sharing among industry peers. Technical discussions covered the evolution from static to dynamic line ratings, complexities of cloud-based architectures, and NERC CIP compliance challenges. The session concluded with a collaborative risk exercise and a preview of future workshops on advanced power flow control and transmission topology optimization, reinforcing the cohort’s commitment to advancing digital assurance in the energy sector.

24 - POWER TRANSMISSION AND DISTRIBUTION

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION