Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Satellite and ground radiotracking of elk

Radiotracking and monitoring of free-living animals in natural environments is providing an effective new technique for acquiring information on biological processes, including animal orientation and navigation. To test the practicability of extending the technique by using satellite systems for tracking animals, a female elk was instrumented with an electronic collar. It contained both the Interrogation Recording Location System (IRLS) transponder and a Craighead-Varney ground-tracking transmitter. The elk was successfully tracked and monitored by satellite during month of April 1970. This was the first time an animal had been tracked by satellite on the surface of the earth.

Craighead, F. C., Jr.↗

The 6-minute walk test predicts mortality in a pulmonary nontuberculous mycobacteria-predominant bronchiectasis cohort

Background: Bronchiectasis is a chronic lung condition frequently associated with nontuberculous mycobacteria pulmonary (NTM) disease. Persons with these conditions are at increased risk of mortality. Patient reported outcome (PRO) instruments and the 6-minute walk test (6MWT) have been shown to predict mortality for several lung conditions, but these measures have not been fully evaluated for bronchiectasis and NTM. Methods: We conducted a retrospective cohort study among adult patients enrolled in a natural history study of bronchiectasis at the National Heart, Lung, and Blood Institute. Electronic medical records were queried for demographic, clinical, microbiologic, radiographic, and PRO instrument data: St. George’s Respiratory Questionnaire (SGRQ), Medical Research Council Dyspnea Scale, and the Pulmonary Symptom Severity Score (PSSS). The study baseline date was defined as the patient’s first visit after January 1st, 2015 with a SGRQ or 6MWT completed. Follow-up was defined as the interval between the study baseline visit and date of death or December 31st, 2019. Sex-stratified Cox proportional-hazards regression was conducted to identify predictors of mortality. Separate models were run for each PRO and 6MWT measure, controlling for age, body mass index (BMI), fibrocavitary disease status, and M. abscessus infection. Results: In multivariable Cox proportional-hazards regression models, the PSSS-severity (aHR 1.29, 95% CI 1.04–1.59), the 6MWT total distance walked (aHR 0.938, 95% CI 0.896–0.981) and distance saturation product (aHR 0.930, 95% CI 0.887–0.974) independently predicted mortality. In addition, BMI was significantly predictive of mortality in all models. Conclusions: The 6MWT and a PRO instrument capturing symptom severity are independently predictive of mortality in our cohort of bronchiectasis patients.

6-minute walk test↗

Airborne Laboratory Apparatus Draws Glass Fibers

Glass-fiber-drawing apparatus designed for studies of effect of gravitation on drawing process. Clear plastic housing surrounds fiber-drawing equipment and some of associated electronic instrumentation. External rack holds video monitor, personal computer, keyboard, videotape recorder, and power switch panel. Mounted in research aircraft, apparatus makes continuous video recordings of formation of fiber at effective gravitational accelerations ranging from 0.001 to 2 times normal Earth gravitational acceleration as aircraft dives, then pulls out of dives. Also records pertinent process data on video image.

Tucker, Dennis S.↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

Electron spectroscopy for chemical analysis: Sample analysis

Exposure conditions in atomic oxygen (ESCA) was performed on an SSL-100/206 Small Spot Spectrometer. All data were taken with the use of a low voltage electron flood gun and a charge neutralization screen to minimize charging effects on the data. The X-ray spot size and electron flood gun voltage used are recorded on the individual spectra as are the instrumental resolutions. Two types of spectra were obtained for each specimen: (1) general surveys, and (2) high resolution spectra. The two types of data reduction performed are: (1) semiquantitative compositional analysis, and (2) peak fitting. The materials analyzed are: (1) kapton 4, 5, and 6, (2) HDPE 19, 20, and 21, and (3) PVDF 4, 5, and 6.

Carter, W. B.↗

Instrument Records Magnetic Fields Generated By Lightning

Portable, self-contained, compact instrument measures and records transient magnetic fields particularly those generated by nearby lightning strikes. Designed to be placed near sensitive electronic equipment in anticipation of thunderstorms. Data recorded during thunderstorms analyzed afterward to determine whether magnetic effects of lightning strong enough to have damaged and/or affected operation of sensitive equipment. Provides data helping engineers decide whether sensitive equipment should be tested for damage and/or other effects caused by lightning. Typical installations in which instrument beneficial include outdoor sensing equipment, computer rooms, broadcasting stations, and powerplant control rooms.

Medelius, Pedro J.↗

Electronic circuitry used to automate paper chromatography

Electronic circuit is used in a paper chromatograph instrument that has excellent sensitivity and furnishes a printed record of each test. The circuit measures and records changes in conductivity in a strip of chromatographic paper as different solutions are placed on it.

Steffensen, G. R.↗

Evidence of solar wind energy deposition into the ionosphere of Mars

Suprathermal electron fluxes measured in the ionosphere of Mars by the retarding potential analyzer (RPA) on Viking lander 1 are presented and compared with the photoelectron flux that is produced by the absorption of the solar EUV. The calculation of the equilibrium photoelectron population on Mars is based on the multistream electron transport theory and a model neutral atmosphere and ionosphere that was actually observed by Viking lander 1. From the theoretical equilibrium photoelectron population, the expected RPA volt-ampere characteristic curves are computed and compared with those recorded by the instrument. The theoretical and the observed RPA currents below about 170 km are in agreement, confirming that the solar EUV is the main source of suprathermal electrons at these altitudes. Above about 170 km an additional source of suprathermal electrons is required to explain the observations.

Mantas, G. P.↗

Sub-Nyquist Distortions in Sampled One- and Two-Dimensional Signals Studied

Hardware testing frequently involves the acquisition of waveform and instrumentation signals, which are often recorded on waveform recorders, oscillographs, and video recorders. Years ago, the waveforms were viewed as analog records, as drawn by a paper strip chart pen or electron beam on a cathode ray tube screen. One of the problems in the past was that the analog electronics may not have been able to accurately display the full amplitude of a signal if the real-time signals exceeded the frequency response bandwidth of the recording device. The advent of digital oscilloscopes, waveform recorders, and video frame-grabbers solved many of the frequency response problems, though not all. A restriction on digital waveform acquisition is well known by people in the instrumentation field. Put simply, the sampling frequency must be at least twice the frequency of any signal to be sampled, or vice versa; the signals must be filtered so that none of the signal frequencies are higher than one-half the sample rate (the Nyquist Limit). Then, per Shannon's Sampling Theorem (1949, ref. 1), any sampled signal can be reconstructed for viewing on a display device. If any signals exceed the Nyquist frequency limit, error signals called aliases occur in the output display.

Williams, Glenn L.↗

Wireless Acoustic Measurement System

A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server can control the operations of the field stations for calibration and for recording of measurement data. A test engineer positions and activates the WAMS. The WAMS automatically establishes the wireless network. Next, the engineer performs pretest calibrations. Then the engineer executes the test and measurement procedures. After the test, the raw measurement files are copied and transferred, through the wireless network, to a hard disk in the control server. Subsequently, the data are processed into 1.3-octave spectrograms.

Anderson, Paul D.↗

Wireless Acoustic Measurement System

A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in "Predicting Rocket or Jet Noise in Real Time" (SSC-00215-1), which appears elsewhere in this issue of NASA Tech Briefs. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro-ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server can control the operations of the field stations for calibration and for recording of measurement data. A test engineer positions and activates the WAMS. The WAMS automatically establishes the wireless network. Next, the engineer performs pretest calibrations. Then the engineer executes the test and measurement procedures. After the test, the raw measurement files are copied and transferred, through the wireless network, to a hard disk in the control server. Subsequently, the data are processed into 1/3-octave spectrograms.

Anderson, Paul D.↗

Dynamic optometer

A dynamic optometer that electronically records the position of the anterior surface of the human lens is described. The geometrical optics of the eye and optometer, and the scattering of light from the lens, are closely examined to determine the optimum conditions for adjustment of the instrument. The light detector and associated electronics are also considered, and the operating conditions for obtaining the best signal-to-noise ratio are determined.

Wilson, D. C.↗

Analysis of contamination data recorded by the IECM camera/photometer

The Camera/Photometer was one of the ten instruments comprising the Induced Environment Contamination Monitor (IECM) developed to monitor the contamination about the Space Shuttle Orbiter during early missions. This experiment consisted of two motion picture cameras, integrating photometers, and associated electronics enclosed in pressurized canisters and separated by 40 cm in order to make stereoscopic observation of particulates. The objectives of the experiment were to record the occurrence of particulates and to determine their velocities, sizes and origins, as well as to measure the background brightness due to unresolved particles. Particle tracks were detected on over 1800 data frames recorded during continuous operations throughout STS-2, -3, -4, and -9. This report discusses the analysis techniques employed in reducing subsequent results, with an emphasis placed on particle size and velocity data. It also describes the operation of the overall experiment and some of the results obtained.

Clifton, K. Stuart↗

Electronic circuits

Twenty-nine circuits and circuit techniques developed for communications and instrumentation technology are described. Topics include pulse-code modulation, phase-locked loops, data coding, data recording, detection circuits, logic circuits, oscillators, and amplifiers.

Source record↗

Continuous microbial cultures maintained by electronically-controlled device

Photocell-controlled instrument maintains microbial culture. It uses commercially available chemostat glassware, provides adequate aeration through bubbling of the culture, maintains the population size and density, continuously records growth rates over small increments of time, and contains a simple, sterilizable nutrient control mechanism.

Eisler, W. J., Jr.↗