Search NASA⌕ Search

SEARCH · Search NASA

Results for “EMBOLISM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Clinical and echocardiographic characteristics of papillary fibroelastomas: a retrospective and prospective study in 162 patients

BACKGROUND: Cardiac papillary fibroelastoma (CPF) is a primary cardiac neoplasm that is increasingly detected by echocardiography. The clinical manifestations of this entity are not well described. METHODS AND RESULTS: In a 16-year period, we identified patients with CPF from our pathology and echocardiography databases. A total of 162 patients had pathologically confirmed CPF. Echocardiography was performed in 141 patients with 158 CPFs, and 48 patients had CPFs that were not visible by echocardiography (<0.2 cm), leaving an echocardiographic subgroup of 93 patients with 110 CPFs. An additional 45 patients with a presumed diagnosis of CPF were identified. The mean age of the patients was 60+/-16 years of age, and 46.1% were male. Echocardiographically, the mean size of the CPFs was 9+/-4.6 mm; 82.7% occurred on valves (aortic more than mitral), 43.6% were mobile, and 91.4% were single. During a follow-up period of 11+/-22 months, 23 of 26 patients with a prospective diagnosis of CPF that was confirmed by pathological examination had symptoms that could be attributable to embolization. In the group of 45 patients with a presumed diagnosis of CPF, 3 patients had symptoms that were likely due to embolization (incidence, 6.6%) during a follow-up period of 552+/-706 days. CONCLUSIONS: CPFs are generally small and single, occur most often on valvular surfaces, and may be mobile, resulting in embolization. Because of the potential for embolic events, symptomatic patients, patients undergoing cardiac surgery for other lesions, and those with highly mobile and large CPFs should be considered for surgical excision.

NASA Discipline Cardiopulmonary↗

Patent Foramen Ovale: Association between the Degree of Shunt by Contrast Transesophageal Echocardiography and the Risk of Future Ischemic Neurologic Events

This study investigated whether there is an association between the degree of interatrial shunting across a patent foramen ovale, as determined by saline contrast transesophageal echocardiography, and the risk of subsequent systemic embolic events, including stroke. Thirty-four patients found to have patent foramen ovale during transesophageal echocardiography were divided into two groups on the basis of the maximum number of microbubbles in the left heart in any single frame after intravenous saline contrast injection: group 1 (n = 16) with a "large" degree of shunt (220 microbubbles) and group 2 (n = 18) with a "small" degree of shunt (23 but <20 microbubbles). Patients were followed up over a mean period of 21 months for subsequent systemic embolic events, including transient ischemic attack and stroke. Five (31%) of the patients with large shunts had subsequent ischemic neurologic events, whereas none of the patients with small shunts had embolic events (p= 0.03). These events occurred in spite of antiplatelet or anticoagulant therapy. We conclude that patients with a large degree of shunt across a patent foramen ovale, as determined by contrast transesophageal echocardiography, are at a significantly higher risk for subsequent adverse neurologic events compared with patients with a small degree of shunt.

Stone, David A.↗

Transesophageal Echocardiography and Contrast-TCD in the Detection of a Patent Foramen Ovale: Experience with 111 Patients

Patent foramen ovale (PFO) is increasingly recognized in association with cryptogenic stroke. Using transesophageal echocardiography (TEE) and transcranial Doppler sonography with ultrasonic contrast medium contrast-(TCD), we evaluated the frequency of a PFO as the fundamental condition of paradoxical embolism in 111 patients after cerebral ischemia. There was a right-left shunt in 50 patients (45%) with TEE. In 31 of 40 patients with stroke of unknown etiology, a PFO was the only detectable finding associated with cerebral ischemia. Using TEE as he "gold standard," the sensitivity of contrast-TCD was 91.3%, specificity 93.8%, and the overall accuracy 92.8%. contrast-TCD failed to detect a right-left shunt in four patients, but there were four other patients with negative TEE and positive contrast-TCD. We conclude that contrast-TCD is a highly sensitive method for detecting a right-left shunt. Its advantages are low cost, its ability to detect single contrast-medium embolism, and control of the Valsalva maneuver by observing the decrease of cerebral blood flow. Evidence of PFO in cryptogenic stroke should prompt a search for a subclinical venous thrombosis as the embolic source.

Klotzsch, Christof↗

Microcapsules and Methods for Making

This invention relates to methods for forming multi-lamellar microcapsules of both hydrophilic and hydrophobic immiscible liquid phases using several polymer/solvent systems. Liquid-Liquid diffusion and spontaneous emulsification are controlled by properly timed sequence exposures of immiscible phases in aqueous vehicles dispersed in hydrocarbon solvents containing small quantities of oil, co-surfactants, and glycerides. Water-in-oil and oil-in-water microcapsules are formed containing selected combinations of several types of drugs, co-encapsulated within fluid compartments inside the microcapsule. Commercial applications of the process and the resultant product relate to drug therapy for treating medical conditions such as cancer, circulatory conditions, and other conditions in which pharmaceuticals are advantageously targeted to specific organs, or delivered in combination with other pharmaceuticals. Small microcapsules may be delivered intravenously to diseased organs or clotted vessels. The use of multiple drugs within the same microcapsule structure provides advantages for applications such as chemoembolization treatments and may be used to deliver both chemotherapeutic drugs, against tumor cells, and an immuno-adjuvant or immunological stimulant to enhance the patient's immune response. Active forms of urokinase and other enzymes may be delivered without dilution to the local site of an embolism for dissolving the embolism. Thus, the invention has several potentially valuable commercial applications related to pharmaceutical and medical applications.

Morrison, Dennis R.↗

Frequency of Atrial Septal Aneurysms in Patients with Cerebral Ischemic Events

Background-Atrial septal aneurysm (ASA) is a putative risk factor for cardioembolism. However, the frequency of ASA in the general population has not been adequately determined. Therefore, the frequency in patients with cerebral ischemic events, compared with the frequency in the general population, is poorly defined. We sought to determine the frequency of ASA in the general population and to compare the frequency of ASA in patients with cerebral ischemic events with the frequency in the general population. Methods and Results-The frequency of ASA in the population was determined in 363 subjects, a sample of the participants in the Stroke Prevention: Assessment of Risk in a Community study (control subjects), and was compared with the frequency in 355 age- and sex-matched patients undergoing transesophageal echocardiography in search of a cardiac source of embolism after a focal cerebral ischemic event. The proportion with ASA was 7.9% in patients versus 2.2% in control subjects (P=0.002; odds ratio of ASA, 3.65; 95% CI, 1.64 to 8.13, in patients versus control subjects). Patent foramen ovale (PFO) was detected with contrast injections in 56% of subjects with ASA. The presence of ASA predicted the presence of PFO (odds ratio of PFO, 4.57; 95% CI, 2.18 to 9.57, in subjects with versus those without ASA). In 86% of subjects with ASA and cerebral ischemia, transesophageal echocardiography did not detect an alternative source of cardioembolism other than an associated PFO. Conclusions-The prevalence of ASA based on this population-based study is 2.2%. The frequency of ASA is relatively higher in patients evaluated with transesophageal echocardiography after a cerebral ischemic event. ASA is frequently associated with PFO, suggesting paradoxical embolism as a mechanism of cardioembolism. In patients with cerebral ischemia and ASA, ASA (with or without PFO) commonly is the only potential cardioembolic source detected with transesophageal echocardiography.

Agmon, Yoram↗

Characteristics of Patent Foramen Ovale Associated with Cryptogenic Stroke: A Biplane Transesophageal Echocardiography Study

Patent foramen ovale is associated with ischemic stroke in patients without a clearly identifiable etiology for stroke (cryptogenic stroke). Paradoxical embolization is thought to be a potential mechanism. However, patent foramen ovale is also found in patients with known cause of stroke. Therefore, using contrast transesophageal echocardiography, we characterized the patent foramen ovale in cryptogenic stroke patients to assess morphological factors that may contribute to paradoxical embolization. Methods: Contrast transesophageal echocardiographic studies of 74 consecutive patients referred for ischemic stroke were reviewed. Twenty-three patients with patent foramen ovale were identified. These patients were classified as having strokes of determined origin or cryptogenic strokes according to criteria developed for the Stroke Data Bank of the National Institute of Neurological Disorders and Stroke. Separation of septum primum from secundum and the number of microbubbles appearing in left atrium were then quantitated. These parameters were compared between patients with cryptogenic stroke and those with known cause of stroke. Results: The patent foramen ovale dimension was significantly larger in patients with cryptogenic stroke compared with patients with an identifiable cause of stroke (2.1+/-1.7 mm versus 057+/-0.78 mm [mean+/-SD]; P<.01). The number of microbubbles was also greater in patients with cryptogenic stroke compared with patients with an identifiable cause of stroke (13.9+/-10.7 versus 1.62+/-0.8 [mean+/-SD]; P<.0005). Conclusions: Patients with cryptogenic stroke have larger patent foramen ovale with more extensive right-to-left inter-atrial shunting than patients with stroke of determined cause. Transesophageal echocardiographically identifiable characteristics of patent foramen ovale may be important in defining the clinical significance of individual patent foramina.

Homma, S.↗

Comparison of Transesophageal and Transthoracic Contrast Echocardiography for Detection of a Patent Foramen Ovale

Presence of a patent foramen ovale may indicate paradoxic embolism in patients with otherwise unexplained embolic disease. Transthoracic contrast echocardiography has been used as a simple technique for detecting patent foramen ovale. However, particularly in patients with poor transthoracic image quality, presence of a patent foramen ovale might be missed. Transesophageal contrast echocardiography provides superior visualization of the atrial septum and therefore is believed to improve diagnostic accuracy. The present study investigates the influence of image quality on the detection of a patent foramen ovale by both transthoracic and transesophageal contrast echocardiography.

Siostrzonek, Peter↗

US-USSR space biology report

The recommendations of the Joint Working Group on Space Biology and Medicine are reported. The exchange of information for the U.S. included the pre- and postflight medical requirements and flight crew health stabilization program for Apollo 16. The U.S.S.R. presentations detailed the medical findings of the Soyuz/Salyut mission, including the postflight autopsy results. The causes of death of the cosmonauts were the occurrence of hypoxia and gaseous embolism. A significant development resulting from the meeting was the agreement that the Joint Working Group strive toward the development of common pre- and postflight medical examination procedures for flight crews for direct comparison of U.S. and U.S.S.R. data.

Friedman, R.↗

A new gas lesion syndrome in man, induced by 'isobaric gas counterdiffusion'

Normal men have been found to develop pruritis and gas bubble lesions in the skin, and disruption of vestibular function, when breathing nitrogen or neon with oxygen while surrounded by helium at increased ambient pressure. This phenomenon, which occurs at stable ambient pressures, at 1 or many ATA, has been designated the isobaric gas counterdiffusion syndrome. In a series of analyses and experiments in vivo and in vitro the cause of the syndrome has been established as due to gas accumulation and development of gas bubbles in tissues as a result of differences in selective diffusivities, for various respired and ambient gases, in the tissue substances between capillary blood and the surrounding atmosphere. The phenomenon described in man is an initial stage of a process shown later in animals to progress to continuous, massive, lethal, intravascular gas embolization.

Lambertsen, C. J.↗

Transpulmonary passage of venous air emboli

Twenty-seven paralyzed anesthetized dogs were embolized with venous air to determine the effectiveness of the pulmonary vasculature for bubble filtration or trapping. Air doses ranged from 0.05 to 0.40 ml/kg min in 0.05-ml increments with ultrasonic Doppler monitors placed over arterial vessels to detect any microbubbles that crossed the lungs. Pulmonary vascular filtration of the venous air infusions was complete for the lower air doses ranging from 0.05 to 0.30 ml/kg min. When the air doses were increased to 0.35 ml/kg min, the filtration threshold was exceeded with arterial spillover of bubbles occurring in 50 percent of the animals and reaching 71 percent for 0.40 ml/kg min. Significant elevations were observed in pulmonary arterial pressure and pulmonary vascular resistance. Systemic blood pressure and cardiac output decreased, whereas left ventricular end-diastolic pressure remained unchanged. The results indicate that the filtration of venous bubbles by the pulmonary vasculature was complete when the air infusion rates were kept below a threshold value of 0.30 ml/kg min.

Butler, B. D.↗

In-Suit Doppler Technology Assessment

The objective of this program was to perform a technology assessment survey of non-invasive air embolism detection utilizing Doppler ultrasound methodologies. The primary application of this technology will be a continuous monitor for astronauts while performing extravehicular activities (EVA's). The technology assessment was to include: (1) development of a full understanding of all relevant background research; and (2) a survey of the medical ultrasound marketplace for expertise, information, and technical capability relevant to this development. Upon completion of the assessment, LSR was to provide an overview of technological approaches and R&D/manufacturing organizations.

Schulze, Arthur E.↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting. distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receive, the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗