Search NASA⌕ Search

SEARCH · Search NASA

Results for “EMIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Wiring design for the control of electromagnetic interference (EMI)

Wiring design is only one important aspect of EMI control. Other important areas for EMI are: circuit design, filtering, grounding, bonding, shielding, lighting, electrostatic discharge (ESD), transient suppression, and electromagnetic pulse (EMP). Topics covered include: wire magnetic field emissions at low frequencies; wire radiated magnetic field emissions at frequencies; wire design guidelines for EMI control; wire design guidelines for EMI control; high frequency emissions from cables; and pulse frequency spectra.

Kopasakis, George↗

Electromagnetic Induction (EMI) Data, 2024, Trail Creek, Colorado

This dataset contains Electromagnetic Induction (EMI) data collected at Trail Creek, Colorado, in 2024. EMI surveys were conducted to investigate the spatial distribution of electrical conductivity in the subsurface, providing insights into soil moisture and subsurface geological features. The surveys were performed along multiple transects to capture variations in conductivity influenced by changes in soil composition, moisture content, and underlying geological structures. This dataset complements other geophysical data collected in the region, including Electrical Resistivity Tomography (ERT) and Terrestrial LiDAR Scanning (TLS), providing a detailed understanding of the subsurface and its impact on surface vegetation and hydrological processes. The data are valuable for environmental geophysics, ecological research, and hydrological modeling in mountainous ecosystems. The files include: - data.zip: the raw EMI data (.csv) - inversion.zip: the inverted resistivity model (.csv and .kml) - kriging.zip: the kriging resistivity model (.csv, .tif, .kmz) - flmd.csv: file level metadata file describing all files within this dataset - dd.csv: data dictionary file describing the column headers within CSV files This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

CMD Mini-Explorer↗

Report of the EMI Testing of the Johnson Noise Thermometry System

This report summarizes the Electromagnetic Interference (EMI) testing of the Johnson Noise Thermometry System developed at ORNL. The EMI performance is very important for Johnson Noise Thermometry because it requires accurate measurement of a very small noise signal that is amplified 10,000 times. Any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Testing is therefore very important in determining the effects of these external noise sources. Results from testing in several environments with various sources of EMI are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EMIS Agent Simulation Model (Electricity Markets Investment Suite) [SWR-19-56]

The Electricity Markets Investment Suite Agent-based Simulation (EMIS-AS) model is an agent-based model developed at NREL for simulating annual investment and retirement decisions of heterogeneous investors in the electricity sector. EMIS-AS is designed to capture the evolution of the electricity generation portfolio resulting from the interactions of heterogeneous investors under different policy and market designs. EMIS-AS not only allows end-users to customize market products and rules, but also to capture investors' heterogeneous financing parameters, technology preferences, beliefs about the future (forecasts), ability to update those forecasts, and risk preferences under uncertainty.

Anwar, Mahammad Bashar↗

Using EMIS to Identify Top Opportunities for Commercial Building Efficiency

Energy Management and Information Systems (EMIS) comprise a broad family of tools and services to manage commercial building energy use. These technologies offer a mix of capabilities to store, display, and analyze energy use and system data, and in some cases, provide control. EMIS technologies enable 10–20 percent site energy savings in best practice implementations. Energy Information System (EIS) and Fault Detection and Diagnosis (FDD) systems are two key technologies in the EMIS family. Energy Information Systems are broadly defined as the web-based software, data acquisition hardware, and communication systems used to analyze and display building energy performance. At a minimum, an EIS provides daily, hourly or sub-hourly interval meter data at the whole-building level, with graphical and analytical capability. Fault Detection and Diagnosis systems automatically identify heating, ventilation, and air-conditioning (HVAC) system or equipment-level performances issues, and in some cases are able to isolate the root causes of the problem. They use computer algorithms to continuously analyze system-level operational data to detect faults and diagnose their causes. Many FDD tools integrate the trend log data from a Building Automation System (BAS) but otherwise are stand-alone software packages; other types of FDD tools are implemented as “on-board” equipment-embedded diagnostics. (This document focuses on the former.) Analysis approaches adopted in FDD technologies span a variety of techniques from rule-based methods to process history-based approaches. FDD tools automate investigations that can be conducted via manual data inspection by someone with expert knowledge, thereby expanding accessibility and breath of analysis opportunity, and also reducing complexity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the Feasibility of UAS-Based EMI Sensing for Underground Utilities Detection and Mapping

This paper investigates the feasibility of using a linear current sensing (LCS) technique integrated on an unmanned aerial system (UAS) for detecting and mapping underground infrastructure rapidly and cost-effectively. The LCS technique is based on data from a wide band of electromagnetic induction frequencies (50 kHz to 2 MHz) using a vector magnetic field gradiometer. This technique takes advantage of a slowly decaying secondary magnetic field in order to achieve greater standoff detection distance ($\frac{1}{R^2}$ vs. $\frac{1}{R^6}$ for compact metallic targets during EMI sensing, where R is the distance from a target to the sensor). These secondary magnetic fields are produced by the excite current on long conductors, allowing detection at a distance of 10 meters or more. The system operates between tens of kHz to a few MHz and uses either an active EMI source or existing EM fields to excite this linear current on a long metallic subsurface target. Once excited, these linear currents produce a secondary magnetic field that is detected with an above ground triaxial magnetic field gradiometer. By moving and tracking its geolocation, the system outputs rich datasets sufficient to support high-fidelity forward and inverse EMI models for estimating the depth and orientation of deep underground long linear metallic infrastructure. The system’s hardware and its integration to a UAS system are outlined, along with the formulation of LCS theory, and numerical and experimental data are presented. The results illustrate that the LCS technique offers large standoff detection, is adaptable to UAS, and could be used effectively for detecting deep underground infrastructure such as wires and pipes.

54 ENVIRONMENTAL SCIENCES↗

EMI survey for maritime satellite, L-band, shipboard terminal

The United States Lines 15,690-ton commercial-container ship, American Alliance, was selected as lead ship for an onboard EMI survey prior to installation of L-Band shipboard terminals for operation with two, geostationary, maritime satellites. In general, the EMI survey revealed tolerable interference levels onboard ship: radiometer measurements indicate antenna-noise temperatures less than 70 K, at elevation angles of 5 deg and greater, at 1559 MHz, at the output terminals of the 1.2-m-diameter, parabolic-dish antenna for the L-Band shipboard terminal. Other EMI measurements include field intensity from 3 cm- and 10 cm-wavelength pulse radars, and conducted-emission tests of primary power lines to both onboard radars.

Taylor, R. E.↗

EMI survey for maritime satellite 1535-1645-MHz shipboard terminal

A 15,690-ton commercial container ship was selected as lead ship for an onboard electromagnetic-interference (EMI) survey prior to installation of 1535-1645-MHz (L-Band) shipboard terminals for communication via a maritime satellite. In general, the EMI survey revealed tolerable interference levels on board ship. Radiometer measurements indicate antenna-noise temperatures less than 70 K at elevation angles of 5 deg and greater at 1559 MHz at the output terminals of the 1.2-m diameter parabolic-dish antenna for the L-band shipboard terminal. Other EMI measurements include field intensity from 3-cm and 10-cm wavelength pulse radars, and conducted-emission tests of primary power lines to both onboard radars.

Taylor, R. E.↗

Characterization of EMI generated by the discharge of a VOLT solar array

The interaction of a high-voltage solar array with the space plasma environment is investigated in a laboratory simulation experiment. Discharges are observed to occur when the solar array is at a sufficiently high negative bias with respect to the plasma. The frequency of occurrence of discharge is found to depend critically on the plasma density and on the geometry of the array. The electromagnetic interference (EMI) associated with a discharge is also measured. The amplitude of EMI increases with the magnitude of the high voltage. Since the discharge-generated EMI is of significant amplitude, its effect on the performance of systems in space must be evaluated.

Leung, P.↗

EMI testing adequacy and flight anomaly history

The effects of electromagnetic interference (EMI) and the space environment on the performance of long-duration spacecraft hardware are surveyed, and the implications for prelaunch test procedures are indicated. Topics addressed include the need for onboard environmental monitoring devices to aid in the identification of environmentally induced anomalies, environmental modeling methods, the existing spacecraft-anomaly data bases, electrostatic discharges, radiation effects, magnetic-field effects, and terrestrial sources of EMI. Statistical data on EMI-induced anomalies are presented in graphs and discussed in detail. It is recommended that testing beyond the current MIL-STD levels be performed on equipment for long-term missions such as the Space Station.

Kuberry, Richard W.↗

A study of occurrence rates of Electromagnetic Interference (EMI) to aircraft with a focus on HIRF (external) High Intensity Radiated Fields

This report presents the methodology and results of a subjective study done by Polytechnic University to investigate Electromagnetic Interference (EMI) events on aircraft. The results cover various types of EMI from on-board aircraft systems, passenger carry-on devices, and externally generated disturbances. The focus of the study, however, was on externally generated EMI, termed High Intensity Radiated Fields (HIRF), from radars, radio and television transmitters, and other man-made emitters of electromagnetic energy. The study methodology used an anonymous questionnaire distributed to experts to gather the data. This method is known as the Delphi or Consensus Estimation technique. The questionnaire was sent to an expert population of 230 and there were 57 respondents. Details of the questionnaire, a few anecdotes, and the statistical results of the study are presented.

Shooman, Martin L.↗

Affordable Electro-Magnetic Interference (EMI) Testing on Large Space Vehicles

Objective: Perform System-Level EMI testing of the Orion Exploration Flight Test-1 (EFT-1) spacecraft in situ in the Kennedy Space Center's Neil Armstrong Operations & Checkout (O&C) Facility in 6 days. The only way to execute the system-level EMI testing and meet this schedule challenge was to perform the EMI testing in situ in the Final Assembly & System Test (FAST) Cell in a reverberant mode, not the direct illumination mode originally planned. This required the unplanned construction of a Faraday Cage around the vehicle and FAST Cell structure. The presence of massive steel platforms created many challenges to developing an efficient screen room to contain the RF energy and yield an effective reverberant chamber. An initial effectiveness test showed marginal performance, but improvements implemented afterward resulted in the final test performing surprisingly well! The paper will explain the design, the challenges, and the changes that made the difference in performance!

Aldridge, Edward↗

Shielded multi-stage EMI noise filter

Electromagnetic interference (EMI) noise filter embodiments and methods for filtering are provided herein. EMI noise filters include multiple signal exclusion enclosures. The multiple signal exclusion enclosures contain filter circuit stages. The signal exclusion enclosures can attenuate noise generated external to the enclosures and/or isolate noise currents generated by the corresponding filter circuits within the enclosures. In certain embodiments, an output of one filter circuit stage is connected to an input of the next filter circuit stage. The multiple signal exclusion enclosures can be chambers formed using conductive partitions to divide an outer signal exclusion enclosure. EMI noise filters can also include mechanisms to maintain the components of the filter circuit stages at a consistent temperature. For example, a metal base plate can distribute heat among filter components, and an insulating material can be positioned inside signal exclusion enclosures.

42 ENGINEERING↗

A Primer on Organizational Use of Energy Management and Information Systems (EMIS)

The document provides a high-level overview of Energy Management and Information Systems (EMIS), which are combined hardware and software products that comprise a broad family of tools and services to manage commercial building energy use. It provides a common reference that can be used to understand key distinguishing factors and core attributes of different solutions within the family of EMIS technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Primer on Organizational Use of Energy Management and Information Systems (EMIS), Second edition

The document provides a high-level overview of Energy Management and Information Systems (EMIS), which are combined hardware and software products that comprise a broad family of tools and services to manage commercial building energy use. It provides a common reference that can be used to understand key distinguishing factors and core attributes of different solutions within the family of EMIS technologies. This is a 2021 update to the original 2015 edition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Management and Information Systems (EMIS) Specification and Procurement Support Materials

This annotated Request for Proposal (RFP) template includes an Energy Management and Information System (EMIS) technology specification, an ongoing services specification, RFP evaluation criteria, and more. It is designed to guide building professionals through the specification, procurement, and selection of an EMIS or related building performance monitoring and diagnostic technology.

building performance↗

The Copper Sulfide Coating on Polyacrylonitrile with Chelating Agents by an Electroless Deposition Method and its EMI Shielding Effectiveness

In this study, a variety of concentrations of chelating agents were added to obtain the anchoring effect and chelating effect in the electroless plating bath. The mechanism of the Cu{sub x(x=1,2)}S growth and the electromagnetic interference shielding effectiveness (EMI SE) of the composite were studied. It was found that the vinyl acetate residued in PAN substrate would be purged due to the swelling effect by chelating agents solution. And then, the anchoring effect occurred due to the hydrogen bonding between the pits of PAN substrate and the chelating agent. Consequently, the copper sulfide layer deposited by the electroless plating reaction with EDTA and TEA. The swelling degree (S{sub d}) was proposed and evaluated from the FT-IR spectra. The relationship between swelling degree of the PAN films and EDTA (C) is expressed as: S{sub d} = 0.13+0.90xe and (-15.15C). And TEA series is expressed as: S{sub d} = 0.07+1.00xe and (-15.15C). On the other hand, the FESEM micrograph showed that the average thickness of copper sulfide increased from 76 nm to 383 nm when the concentration of EDTA increased from 0.00M to 0.20M. Consequently, the EMI SE of the composites increased from 10{approx}12 dB to 25{approx}27 dB. The GIA-XRD analyze indicated that the deposited layer consisted of CuS and Cu{sub 2}S.

36 MATERIALS SCIENCE↗

A physical comparison of a fluoroscopic CAT system and the EMI head scanner

A quantitative comparison of the capabilities to produce computerized tomograms was made between the EMI head scanner and reconstructions from images provided by a large screen low light level-TV camera fluoroscopic system. A phantom made from lucite containing rods of various materials and sizes was used. The computer printout of each was analyzed and a correlation of 0.8 was noted between the results of both systems. The differential attenuation detectability of the fluoroscopic system was found to be comparable to or better than the EMI unit. As expected from a consideration of the quantum statistics for each system, the noise in the obtained reconstructions was also comparable. It is concluded that such a fluoroscopic system performs favorably when compared to the presently available commercial systems.

Baily, N. A.↗