Search NASA⌕ Search

SEARCH · Search NASA

Results for “EMT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A PSCAD Library Component Featuring a Reduced-Order IBR Model for EMT-Based Fault Studies

This paper presents a fully implemented inverter reduce-order-model (ROM) in an EMT simulation (PSCAD) library component for direct user utilization in protection studies. The developed inverter ROM has the following features: Equivalent to a full IBR inverter model with positive- and negative-sequence current formulation and representation A python script is developed to fully automate this process, including training data generation, ROM parameter training, updating parameters, and model verification and validation. With this PSCAD ROM library component, protection engineers can utilize a trustworthy, accurate ROM for protection studies in an easy-to-use and streamlined manner.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMT Workshop 2026

These are files for the 2026 workshop edition of the

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

A Generic FSC Wind Park EMT Model with IEEE Std 2800-Compliant Fault Ride-Through Capability

The modern power grid is seeing more and more electricity come from renewable sources like wind farms, which use sophisticated power electronics instead of traditional spinning generators. To keep everything running smoothly and meet industry standards such as IEEE 2800, these systems need smart control strategies. In our work, we built a flexible computer model of a full-scale wind farm converter that can handle grid disturbances without shutting down. When a fault or storm hits, the model’s built-in logic automatically adjusts the currents it sends to the grid and protects its internal energy storage, ensuring the wind farm stays connected and doesn’t damage its own equipment. Once the disturbance clears, the model restores normal operation seamlessly, so there’s no long interruption in power delivery. At the same time, it carefully regulates the voltage where the wind farm ties into the larger grid, helping to maintain safe voltage levels across the network. Our simulations show that this control setup not only meets all the requirements of IEEE Standard 2800 but also allows the wind farm to recover quickly and predictably, keeping the lights on no matter what happens on the grid.

17 WIND ENERGY↗

Sparse Linear Solvers for Large-scale Electromagnetic Transient Simulations

Linear solvers form the basis for electromagnetic transient (EMT) simulations. There is a need to speed up EMT simulations as larger regions are analyzed using EMT simulations. For the same, the performance of linear solvers plays an important role. Exploiting the sparsity of the matrices generated in EMT simulations could assist with speed-up. Scalability is also crucial as power grids expand, demanding solutions capable of accommodating the increasing system size. Recent studies from the North American Electric Reliability Corporation (NERC) increasingly emphasize that EMT simulation models of the power grid will grow larger with the inclusion of power electronics components. Parallelisms in sparsity patterns exploit modern central processing units (CPUs), multi-core CPUs, and graphics processing units (GPUs) architectures in sparse solver designs. Therefore, this paper explores publicly available existing linear solvers and investigates their efficiency in large-scale power grid simulations. A large-scale power grid is developed by increasing the size of the IEEE 39 bus test system to up to 39000 bus systems.

Hsu, Kuan-Chieh↗

Linear Solver for Electromagnetic Simulation of General Distribution Feeders

High-fidelity electromagnetic transient (EMT) modeling is required for accurate simulation and analysis of power system dynamics in modern distribution feeders. However, the high-fidelity of EMT models often leads to significant computational challenges, particularly in terms of computational resources and simulation time. This paper investigates the development and application of a detailed EMT model for general distribution feeders, with a focus on improving computational efficiency. A direct linear solver is proposed for a bordered block diagonal (BBD) matrix structure commonly encountered in a EMT model of distribution feeders. The solver integrates the Schur complement method with the block tridiagonal matrix algorithm to enhance the computational performance. The proposed solver is validated using the primary feeder of the IEEE 342-node test system, demonstrating its accuracy and efficiency in EMT simulations. Furthermore, the solver’s performance is benchmarked against MATLAB’s built-in linear solvers, showing significant improvements in computation time while maintaining high fidelity and accuracy in simulation results.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

Violation of energy conditions and the gravitational radius of the proton

The energy-momentum tensor (EMT) of the proton encodes fundamental information about its mass, pressure, and shear distributions. Using recent lattice QCD data for the gravitational form factors, we show that the Breit-frame Wigner EMT may be of Hawking-Ellis type IV in the proton’s core. Such EMT violates all pointwise energy conditions and lacks a causal rest frame so that the usual mechanical picture fails at short distances. We define the —a new hadronic observable—marking the scale where the EMT becomes ordinary (type I) and the classical interpretation is restored. We also derive from the averaged null energy condition nonperturbative, model-independent quantum field theory constraints on gravitational form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pion gravitational form factors in the QCD instanton vacuum. I

The pion form factors of the QCD energy-momentum tensor (EMT) are studied in the instanton liquid model (ILM) of the QCD vacuum. In this approach, the breaking of conformal symmetry is encoded in the form of stronger-than-Poisson fluctuations in the number of instantons. For the trace of the EMT, it is shown that the gluonic trace anomaly term contributes half the pion mass, with the other half coming from the quark-mass-dependent σ term. The Q 2 dependence of the form factors is governed by glueball and scalar meson exchanges. For the EMT, the spin-0 (trace) and spin-2 (traceless rank-2 tensor) form factors are computed at next-to-leading order in the instanton density using effective quark operators. Relations between the gluon and quark contributions to the EMT form factors are derived. The form factors are also expressed in terms of the pion light-front wave functions in the ILM. The results at the low resolution scale of the inverse instanton size are evolved to higher scales using the renormalization group equation. The ILM results compare well with those of recent lattice QCD calculations. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation

Photovoltaic (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. The proprietary nature of these approaches makes it challenging to share electromagnetic transients (EMT) domain models for system studies. This research work presents an approach to develop EMT models from experimental data. We use novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to reduce the time taken to develop an EMT model for an inverter under test (IUT). We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests. The tests include voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data were used to train a neural network model representing the dynamic behavior of the IUT. The model was subsequently imported into an EMT tool using co-simulation techniques, and thus completing the modeling effort.

black box inverter modeling↗

A Semi-Analytical Approach for State-Space Electromagnetic Transient Simulation

Here, this paper proposes a semi-analytical approach for efficient and accurate electromagnetic transient (EMT) simulation of a power grid. The approach first derives a high-order semi-analytical solution (SAS) of the grid’s state-space EMT model using the differential transformation (DT), and then evaluates the solution over enlarged, variable time steps to significantly accelerate the simulations while maintaining its high accuracy on detailed fast EMT dynamics. The approach also addresses switches during large time steps by using a limit violation detection algorithm with a binary search-enhanced quadratic interpolation. Case studies are conducted on EMT models of the IEEE 39-bus system and large-scale systems to demonstrate the merits of the new simulation approach against traditional numerical methods.

electromagnetic transient↗

Linear Solvers for Collector Systems of Generalized Large-scale Inverter-Based Resources

Collector systems for inverter-based resources (IBRs) are typically represented by equivalent circuits for electromagnetic transient (EMT) simulations. Recent studies have revealed that modeling a detailed collector system is essential to accurately represent the behavior of IBRs, especially when dealing with partial tripping during external disturbances. However, there are several challenges in simulating a detailed EMT model of a collector system due to the time required to simulate such systems. Thus, this paper investigates the modeling of a detailed collector system, taking into account its configuration and components as defined in IEEE standard 2800. The configurations include the collector systems of generalized large-scale IBR plants. The components include the main IBR transformer, collector bus, and feeders with lines and/or cables. The EMT model of the collector system is represented by differential algebraic equations (DAEs) that are discretized to form linear equations that are solved using linear solvers. In this paper, linear solvers are proposed based on the Schur complement method, which are utilized for simulation of the EMT model of collector systems of generalized large-scale IBRs to accelerate simulation speed while maintaining the accuracy of the results. The proposed solvers are verified by comparing the performance to that of linear solvers provided in MATLAB.

Choi, Jongchan↗

Electromagnetic Transient Modeling of Data Centers

This report serves as a user manual for the accompanying EMT model library developed by the National Laboratory of the Rockies (NLR) for various equipment in large data centers. The EMT model library enables detailed modeling of large data center loads for conducting grid stability studies. The EMT model library for data centers include detailed models of a 5.5 kW power supply unit (PSU), a 2.5 uninterruptible power supply (UPS), a 260 MW gas turbine-generator, a 500 kW motor load, and a 33 kW IT rack. These components represent all major equipment in data centers that need to be modeled for performing grid stability studies for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reflections on Noether’s second theorem and the energy-momentum tensor

Through symmetry of the action under global spacetime translations, Noether’s first theorem infamously entails an energy-momentum tensor (EMT) that is neither symmetric nor gauge-invariant. In a prior work [Phys. Rev. D 106, 125012 (2022)], I had obtained a symmetric and gauge-invariant EMT by using Noether’s second theorem instead, with local spacetime translations as the symmetry group. However, the derivation therein was flawed, containing a faulty assumption about the transformation rule for spinor fields. In this work, I revisit the derivation of the previous work, both correcting the faulty step and simplifying the derivation for broader accessibility. The end result is an EMT for quantum chromodynamics that is gauge-invariant, but not symmetric.

Quantum chromodynamics↗

Automation for Grid Interconnected Laboratory Emulation

As computational capabilities improve, digital twins are becoming vital for evaluating equipment realistically in laboratories. This paper outlines a digital twin architecture for the power grid, employing electromagnetic transient (EMT) simulation alongside real-time simulation of power hardware and hierarchical control systems. EMT simulation occurs on a high-performance computing server for scalability. Additionally, the paper describes a workflow and real-time data streaming software facilitating connectivity among EMT simulation, hierarchical control systems, and power hardware. This software enables automated equipment connectivity in the laboratory for realistic evaluations, aiding in identifying necessary upgrades for both equipment control systems and the power grid.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Behavior of Multiple PV Plants in Future Power Grids During Events

As the integration of multiple photovoltaic (PV) plants into power grids grows, the dynamic response of each plant and their interactions during transient events demands a deeper understanding. In this paper, the dynamic behavior of multiple PV plants connected to future power grids is comprehensively explored using site-specific high-fidelity electromagnetic transient (EMT) PV plant models and generic high-fidelity EMT PV plant models. This research demonstrates the need to employ multiple high-fidelity EMT PV plant models to understand the intricate interactions between multiple PV plants during grid events. These models, developed in Fortran within the PSCAD environment, encompass a range of operational scenarios and plant configurations, offering invaluable insights crucial for future system planning with multiple PV plants to enhance grid stability.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Electromagnetic Transient Simulation of Photovoltaic Inverter Using Implicit-Explicit Solver

This paper introduces the implementation of electromagnetic transient (EMT) simulations of a photovoltaic (PV) inverter module using the Implicit-Explicit (ImEx) solver in the Suite of Nonlinear and Differential/Algebraic Equation Solvers (SUNDIALS). This study demonstrates the effectiveness of the ImEx solver in overcoming the challenges inherent in simulating the complex dynamics of PV inverter modules. Furthermore, using SUNDIALS’ ImEx solver module ARKODE for EMT simulation automates key aspects of the process, such as numerical integration, providing substantial benefits including enhanced consistency, faster implementation, reduced human error, and the capability to handle the complexities of advanced numerical integration. By conducting comparative simulations with an implicit method used in commercial software, the research showcases the ImEx solver’s capability in achieving high accuracy and reliability. Results indicate that leveraging the ImEx approach significantly enhances modeling fidelity and reduces simulation setup times, offering a promising tool for the EMT analysis of PV inverter systems in power electronics-dominated power grids.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗