Search NASA⌕ Search

SEARCH · Search NASA

Results for “END EFFECTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Longitudinal compressive failure modes in fiber composites End attachment effects on IITRI type test specimens

The end-attachment effects on longitudinal compressive strength of IITRI type specimen unidirectional fiber composites are formally assessed using finite-element analysis (FEA) in conjunction with composite mechanics. Sixteen different cases were analyzed to evaluate end-attachment effects (such as degree of misalignment, type of misalignment, progressive end-tab debonding, and specimen thickness) on stress distribution, peak stresses, buckling loads, and buckling mode shapes. The results obtained from the FEA and comparisons with fractured specimens show that eccentricities induce bending-type stresses which peak near the end-tabs and cause flexural type fracture. Also, guidelines are included for placing back-to-back strain gages to measure the presence/absence of possible end-attachment and eccentricity effects.

Chamis, C. C.↗

Viscous Dissipation and Apparent Permeability of Gas Flow in Nanoporous Media

The nanopore confinement effect can increase the mobility for gas flow in shale rocks, and the apparent permeability is usually adopted to account for this effect. However, most of the apparent permeability calculation models are derived based on straight channels (capillaries) and neglect the influence of end effect. The end effect is caused by the bending of streamlines which yields more viscous dissipation and additional flow resistance for gas flow in nanoporous media. Here, for the first time the viscous dissipation for gas flow in nanoporous media is analyzed. In addition, an improved apparent permeability calculation model is proposed based on the Beskok-Karniadakis (B-K) model by introducing the influence of end effect, which is characterized by the ratio of the length to the width of a short channel (L/H). The accuracy of this model is validated by lattice Boltzmann simulations of gas flow in three different geometries: an infinite-length straight channel, a finite-length straight channel, and nanoporous media. For the infinite-length straight channel, there is no end effect therefore both the B-K model and the improved model can well predict the apparent permeability. However, for the finite-length straight channel and nanoporous media, the original B-K model overestimates the gas apparent permeability as it neglects the influence of end effect, while the improved model can still well predict the gas apparent permeability. In summary, the improved apparent permeability calculation model is more reasonable in predicting gas mobility in nanoporous media.

58 GEOSCIENCES↗

Wind-tunnel Investigation of End-plate Effects of Horizontal Tails on a Vertical Tail Compared with Available Theory

A vertical-tail model with stub fuselage was tested in combination with various simulated horizontal tails to determine the effect of horizontal-tail span and location on the aerodynamic characteristics of the vertical tail. Available theoretical data on end-plate effects were collected and presented in the form most suitable for design purposes. Reasonable agreement was obtained between the measured and theoretical end-plate effects of horizontal tails on vertical tails, and the data indicated that the end-plate effect was determined more by the location of the horizontal tail than by the span of the horizontal tail. The horizontal tail gave most end-plate effect when located near either tip of the vertical tail and, when located near the base of the vertical tail, the end-plate effect was increased by moving the horizontal tail rearward.

TAIL SURFACES - HINGE MOMENTS↗

Dominant end-tunneling effect in two distinct Luttinger liquids coexisting in one quantum wire

Luttinger liquids occupy a notable place in physics as one of the most understood classes of quantum many-body systems. The experimental mission of measuring its main prediction, power laws in observable quantities, has already produced a body of exponents in different semiconductor and metallic structures. Here, we combine tunneling spectroscopy with density-dependent transport measurements in the same quantum wires over more than two orders of magnitude in temperature to very low electron temperatures down to ∼40 mK. This reveals that, when the second 1D subband becomes populated, the temperature dependence splits into two ranges with different exponents in the power-law dependence of the conductance, both dominated by the finite-size effect of the end-tunneling process. This result demonstrates the importance of measuring the Luttinger parameters as well as the number of modes independently through spectroscopy in addition to the transport exponent in the characterization of Luttinger liquids. This opens a pathway to unambiguous interpretation of the exponents observed in quantum wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of end reflections on conversion efficiency of coaxial relativistic backward wave oscillator

This paper theoretically investigates the effect of end reflections on the operation of the coaxial relativistic backward wave oscillator (CRBWO). It is found that the considerable enhancement of the end reflection at one end increases the conversion efficiency, but excessively large end reflections at both ends weaken the asynchronous wave-beam interaction and thus reduce the conversion efficiency. Perfect reflection at the post end significantly improves the interaction between the electron beam and the asynchronous harmonic so that the conversion efficiency is notably increased. Based on the theoretical research, the diffraction-CRBWO with the generated microwave diffracted and output through the front end of the coaxial slow wave structure cavity is proposed. The post end is conductively closed to provide the perfect reflection. This promotes the amplitude and uniformity of the longitudinal electric field on the beam transmission line and improves the asynchronous wave-beam interaction. In numerical simulations under the diode voltage and current of 450 kV and 5.84 kA, microwave generation with the power of 1.45 GW and the conversion efficiency of 55% are obtained at the frequency of 7.45 GHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Meta-metallic coils and resonators: Methods for high Q-value resonant geometries

A novel method of decreasing ohmic losses and increasing Q-value in metallic resonators at high frequencies is presented. The method overcomes the skin-depth limitation of rf current flow cross section. The method uses layers of conductive foil of thickness less than a skin depth and capacitive gaps between layers. The capacitive gaps can substantially equalize the rf current flowing in each layer, resulting in a total cross-sectional dimension for rf current flow many times larger than a skin depth. Analytic theory and finite-element simulations indicate that, for a variety of structures, the Q-value enhancement over a single thick conductor approaches the ratio of total conductor thickness to skin depth if the total number of layers is greater than one-third the square of the ratio of total conductor thickness to skin depth. The layer number requirement is due to counter-currents in each foil layer caused by the surrounding rf magnetic fields. We call structures that exhibit this type of Q-enhancement “meta-metallic.” In addition, end effects due to rf magnetic fields wrapping around the ends of the foils can substantially reduce the Q-value for some classes of structures. Foil structures with Q-values that are substantially influenced by such end effects are discussed as are five classes of structures that are not. We focus particularly on 400 MHz, which is the resonant frequency of protons at 9.4 T. Simulations at 400 MHz are shown with comparison to measurements on fabricated structures. The methods and geometries described here are general for magnetic resonance and can be used at frequencies much higher than 400 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An extended JBN method of determining unsteady-state two-phase relative permeability

Relative permeability is the reduction of permeability of porous media when subjected to multiphase flow and a key parameter in subsurface hydrology. The JBN method is a well-known method of obtaining relative permeability, which measures the overall pressure drop and the effluent phase ratio versus time during two-phase displacements. By assuming no capillary pressure or gravity, the JBN method obtains the relative permeabilities to both phases at the core outlet. Since data across a range of saturations are acquired in a relatively short time, this method is widely used. This work extends the JBN method by having (1) section-wise pressure drop measurements between the core inlet, four pressure taps on the core and the outlet, (2) local saturation measurements, and (3) local phase fluxes. With these data, the extended JBN method can determine relative permeabilities to both phases at each pressure tap of the core (not just at the core outlet). The JBN extension is shown using a data set where CO 2 invades a brine-filled core. From this it is found that the advantages of the extended JBN method over the regular JBN method are: (1) four times more data are obtained, and (2) data are more accurate because the capillary end effect is experimentally avoided. Avoiding the end effect results in tripling the saturation range, and obtaining relative permeabilities that are consistent with steady-state measurements and roughly 40% higher than those from the regular JBN method.

54 ENVIRONMENTAL SCIENCES↗

Dissipative heating effects and end corrections for viscous Newtonian flow in high shear capillary tube viscometry

The effect of dissipation heating on the apparent viscosity measured in capillary tube viscometry is described in this paper. Conditions of low Reynolds number and high shear are assumed. End corrections to the tube flow are incorporated. The flow curves show decreasing apparent viscosity when the shear stress increases. The configuration of the flow curves plotted in logarithmic presentation are found to be identical for fluids with Newtonian behavior. Convection is the predominant mechanism in removal of the heat in short capillary tube. The estimated upper bound for the shear stress obtainable in short length capillary tubes appears to be of the order of magnitude of 10 MPa limited primarily by the pressure drop associated with the constant end correction from the flat ended inlet and exit of the tube.

Jakobsen, J.↗

Effects of end group functionalization and level alignment on electron transport in molecular devices

The effect of metal-molecule coupling on electron transport is examined in the prototypical case of alkane chains sandwiched between gold contacts and bridged by either amine or thiol groups. The results show that end group functionalization plays a crucial role in controlling electron transport, and that the symmetries and spatial extent of orbitals near the Fermi level control the conductivity rather than the strength of the bonding. For amine/Au and thiol/Au junctions, a crossover in conductivity with increasing bias is predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An analytical approach to thermal modeling of Bridgman-type crystal growth. I - One-dimensional analysis

A relatively simple one-dimensional thermal model of the Bridgman growth process has been developed which is applicable to the growth of small diameter samples with conductivities similar to those of metallic alloys. The heat flow in a translating rod is analyzed in a way that is applicable to Biot numbers less than unity. The model accommodates an adiabatic zone, different heat transfer coefficients in the hot and cold zones, and changes in sample material properties associated with phase change. The analysis is applied to several simplified cases. The effect of the rod's motion is studied in a three-zone furnace for a rod sufficiently long that end effects can be neglected; end effects are then investigated for a motionless rod. Finally, the addition of a fourth zone, an independently controlled booster heater between the main heater and the adiabatic zone, is evaluated for its ability to increase the gradient in the sample at the melt interface and to control the position of the interface.

Naumann, R. J.↗

Effects of the end fixation of airplane struts

The main purpose of this report is to give references to literature on the subject of end fixation of airplane struts and also to furnish the constructor with a general survey of the simplest methods for estimating the end-fixation effect.

Teichmann, Alfred↗

SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and linearity that is superior to Gafchromic-films and ionization chamber used for geometric and dosimetric QA in HDR-brachytherapy, respectively.

60 APPLIED LIFE SCIENCES↗

Static tensile and tensile creep testing of four boron nitride coated ceramic fibers at elevated temperatures

Six types of uncoated ceramic fibers were static tensile and tensile creep tested at various elevated temperatures. Three types of boron nitride coated fibers were also tested. Room temperature static tensile tests were initially performed on all fibers, at gage lengths of 1, 2, and 4 inches, to determine the magnitude of end effects from the gripping system used. Tests at one elevated temperature, at gage lengths of 8 and 10 inches, were also conducted, to determine end effects at elevated temperatures. Fiber cross sectional shapes and areas were determined using scanning electron microscopy. Creep testing was typically performed for 4 hours, in an air atmosphere.

Coguill, Scott L.↗

Application of High Order Acoustic Finite Elements to Transmission Losses and Enclosure Problems

A family of acoustic finite elements was developed based on C continuity (acoustic pressure being the nodal variable) and the no-flow condition. The family include triangular, quadrilateral and hexahedral isoparametric elements with linear quadratic and cubic variation in modelling and distortion. Of greatest use in problems with irregular boundaries are the cubic isoparametric elements: the 32 node hexahedral element for three-dimensional systems; and the twelve node quadrilateral and ten node triangular elements for two-dimensional/axisymmetric applications. These elements were applied to problems involving cavity resonances, transmission loss in silencers and the study of end effects, using a Floating Point Systems 164 attached array processor accessed through an Amdahl 5860 mainframe. The elements are presently being used to study the end effects associated with duct terminations within finite enclosures. The transmission losses with various silencers and sidebranches in ducts is also being studied using the same elements.

Craggs, A.↗

Methods for separation of polymeric compounds

Recently two techniques using free solution electrophoresis to separate charged-uncharged polymer conjugates have proven successful: End Labeled Free Solution Electrophoresis (ELFSE) for DNA sequencing, and Free Solution Conjugate Electrophoresis (FSCE) for molar mass profiling of uncharged polymers. Previous attempts have been made to analyze experimental data generated by these new techniques for the electrophoresis of molecules with varying charge distributions. However, the importance of the ends of the polymers in determining the polymer's overall mobility was neglected in previous work. Through a careful investigation and a reanalysis of the experimental data, it is determined here that this “end effect” critically impacts the behavior of polymers and charged-uncharged polymer conjugates during electrophoresis. In this way, the invention provides for methods that exploit this “end effect” for the separation of polymeric molecules on the basis of size, including for example DNA separation and sequencing techniques.

Slater, Gary W.↗

Load Diffusion in Composite and Smart Structures

The research carried out here builds on our previous NASA supported research on the general topic of edge effects and load diffusion in composite structures. Further fundamental solid mechanics studies were carried out to provide a basis for assessing the complicated modeling necessary for the multi-functional large scale structures used by NASA. An understanding of the fundamental mechanisms of load diffusion in composite subcomponents is essential in developing primary composite structures. Some specific problems recently considered were those of end effects in smart materials and structures, study of the stress response of pressurized linear piezoelectric cylinders for both static and steady rotating configurations, an analysis of the effect of pre-stressing and pre-polarization on the decay of end effects in piezoelectric solids and investigation of constitutive models for hardening rubber-like materials. Our goal in the study of load diffusion is the development of readily applicable results for the decay lengths in terms of non-dimensional material and geometric parameters. Analytical models of load diffusion behavior are extremely valuable in building an intuitive base for developing refined modeling strategies and assessing results from finite element analyses.

Horgan, Cornelius O.↗

Load Diffusion in Composite and Smart Structures

The research carried out here builds on our previous NASA supported research on the general topic of edge effects and load diffusion in composite structures. Further fundamental solid mechanics studies were carried out to provide a basis for assessing the complicated modeling necessary for the multi-functional large scale structures used by NASA. An understanding of the fundamental mechanisms of load diffusion in composite subcomponents is essential in developing primary composite structures. Some specific problems recently considered were those of end effects in smart materials and structures, study of the stress response of pressurized linear piezoelectric cylinders for both static and steady rotating configurations, an analysis of the effect of pre-stressing and pre-polarization on the decay of end effects in piezoelectric solids and investigation of constitutive models for hardening rubber-like materials. Our goal in the study of load diffusion is the development of readily applicable results for the decay lengths in terms of non-dimensional material and geometric parameters. Analytical models of load diffusion behavior are extremely valuable in building an intuitive base for developing refined modeling strategies and assessing results from finite element analyses. The decay behavior of stresses and other field quantities provides a significant aid towards this process. The analysis is also amenable to parameter study with a large parameter space and should be useful in structural tailoring studies. Special purpose analytical models of load diffusion behavior are extremely valuable in building an intuitive base for developing refined modeling strategies and in assessing results from general purpose finite element analyses. For example, a rational basis is needed in choosing where to use three-dimensional to two-dimensional transition finite elements in analyzing stiffened plates and shells. The decay behavior of stresses and other field quantities furnished by this research provides a significant aid towards this element transition issue. A priori knowledge of the extent of boundary-layers induced by edge effects is also useful in determination of the instrumentation location in structural verification tests or in material characterization tests.

Horgan, C. O.↗