Flow Fields of Internally Mixed Exhaust Systems With External Plug For Supersonic Transport Applications
Commercial supersonic vehicles of the future will likely use engines with lower bypass ratios, where the design of the internal mixer will have a strong impact on the noise produced by the jet plume. Their exhaust systems may also feature external plugs to improve boattail angle for cruise performance at supersonic speeds. Currently there are no publicly available empirical noise models for such nozzle systems, and insight into their flow fields will help in creating these models. For those attempting to make large eddy simulations and other higher fidelity methods be their main prediction tool, the internally mixed exhaust system is also a good test case when going beyond simple single-stream jets. The turbulent flow statistics of several configurations previously tested for noise and shocks have been measured for flow conditions that can be used in development of empirical models and validating scale-resolving prediction tools. These measurements are presented and briefly analyzed for insights into the noise impacts from the flow impacts observed.