Search NASASearch

SEARCH · Search NASA

Results for “EXHAUST SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flow Fields of Internally Mixed Exhaust Systems With External Plug For Supersonic Transport Applications

Commercial supersonic vehicles of the future will likely use engines with lower bypass ratios, where the design of the internal mixer will have a strong impact on the noise produced by the jet plume. Their exhaust systems may also feature external plugs to improve boattail angle for cruise performance at supersonic speeds. Currently there are no publicly available empirical noise models for such nozzle systems, and insight into their flow fields will help in creating these models. For those attempting to make large eddy simulations and other higher fidelity methods be their main prediction tool, the internally mixed exhaust system is also a good test case when going beyond simple single-stream jets. The turbulent flow statistics of several configurations previously tested for noise and shocks have been measured for flow conditions that can be used in development of empirical models and validating scale-resolving prediction tools. These measurements are presented and briefly analyzed for insights into the noise impacts from the flow impacts observed.

Turbulence, Jets, Particle Image velocimetry

Flow Fields of Internally Mixed Exhaust Systems With External Plug For Supersonic Transport Applications

Commercial supersonic vehicles of the future will likely use engines with lower bypass ratios, where the design of the internal mixer will have a strong impact on the noise produced by the jet plume. Their exhaust systems may also feature external plugs to improve boattail angle for cruise performance at supersonic speeds. Currently there are no publicly available empirical noise models for such nozzle systems, and insight into their flow fields will help in creating these models. For those attempting to make large eddy simulations and other higher fidelity methods be their main prediction tool, the internally mixed exhaust system is also a good test case when going beyond simple single-stream jets. The turbulent flow statistics of several configurations previously tested for noise and shocks have been measured for flow conditions that can be used in development of empirical models and validating scale-resolving prediction tools. These measurements are presented and briefly analyzed for insights into the noise impacts from the flow impacts observed.

Fluid Mechanics and Thermodynamics

A computational study of advanced exhaust system transition ducts with experimental validation

The current study is an application of CFD to a 'real' design and analysis environment. A subsonic, three-dimensional parabolized Navier-Stokes (PNS) code is used to construct stall margin design charts for optimum-length advanced exhaust systems' circular-to-rectangular transition ducts. Computer code validation has been conducted to examine the capability of wall static pressure predictions. The comparison of measured and computed wall static pressures indicates a reasonable accuracy of the PNS computer code results. Computations have also been conducted on 15 transition ducts, three area ratios, and five aspect ratios. The three area ratios investigated are constant area ratio of unity, moderate contracting area ratio of 0.8, and highly contracting area ratio of 0.5. The degree of mean flow acceleration is identified as a dominant parameter in establishing the minimum duct length requirement. The effect of increasing aspect ratio in the minimum length transition duct is to increase the length requirement, as well as to increase the mass-averaged total pressure losses. The design guidelines constructed from this investigation may aid in the design and manufacture of advanced exhaust systems for modern fighter aircraft.

Wu, C.

Altitude-Wind-Tunnel Investigation of R-4360-18 Power-Plant Installation for XR60 Airplane: Performance of Induction and Exhaust Systems - 3

A study has been made of the performance of the induction and the exhaust systems on the XR60 power-plant installation as part of an investigation conducted in the Cleveland altitude wind tunnel. Altitude flight conditions from 5000 to 30,000 feet were simulated for a range of engine powers from 750 to 3000 brake horsepower. Slipstream rotation prevented normal pressure recoveries in the right side of the main duct in the region of the right intercooler cooling-air duct inlet. Total-pressure losses in the charge-air flow between the turbosupercharger and the intercoolers were as high as 2.1 inches of mercury. The total-pressure distribution of the charge air at the intercooler inlets was irregular and varied as much as 1.0 inch of mercury from the average value at extreme conditions, Total-pressure surveys at the carburetor top deck showed a variation from the average value of 0.3 inch of mercury at take-off power and 0.05 inch of mercury at maximum cruising power, The carburetor preheater system increased the temperature of the engine charge air a maximum of about 82 F at an average cowl-inlet air temperature of 9 F, a pressure altitude of 5000 feet, and a brake horsepower of 1240.

Dupree, David T.

A static investigation of several STOVL exhaust system concepts

A static cold flow scale model test was performed in order to determine the internal performance characteristics of various STOVL exhaust systems. All of the concepts considered included a vectorable cruise nozzle and a separate vectorable vertical thrust ventral nozzle mounted on the tailpipe. The two ventral nozzle configurations tested featured vectorable constant thickness cascade vanes for area control and improved performance during transition and vertical lift flight. The best transition performance was achieved using a butterfly door type ventral nozzle and a pitch vectoring 2DCD or axisymmetric cruise nozzle. The clamshell blocker type of ventral nozzle had reduced transition performance due to the choking of the tailpipe flow upstream of the cruise nozzle.

Romine, B. M., Jr.

New Model Exhaust System Supports Testing in NASA Lewis' 10- by 10-Foot Supersonic Wind Tunnel

In early 1996, the ability to run NASA Lewis Research Center's Abe Silverstein 10- by 10- Foot Supersonic Wind Tunnel (10x10) at subsonic test section speeds was reestablished. Taking advantage of this new speed range, a subsonic research test program was scheduled for the 10x10 in the fall of 1996. However, many subsonic aircraft test models require an exhaust source to simulate main engine flow, engine bleed flows, and other phenomena. This was also true of the proposed test model, but at the time the 10x10 did not have a model exhaust capability. So, through an in-house effort over a period of only 5 months, a new model exhaust system was designed, installed, checked out, and made ready in time to support the scheduled test program.

Roeder, James W., Jr.

Acoustically shielded exhaust system for high thrust jet engines

A flade exhaust nozzle for a high thrust jet engine is configured to form an acoustic shield around the core engine exhaust flowstream while supplementing engine thrust during all flight conditions, particularly during takeoff. The flade airflow is converted from an annular 360.degree. flowstream to an arcuate flowstream extending around the lower half of the core engine exhaust flowstream so as to suppress exhaust noise directed at the surrounding community.

Carey, John P.

Flow field description of the Space Shuttle Vernier reaction control system exhaust plumes

The flow field for the Vernier Reaction Control System (VRCS) jets of the Space Shuttle Orbiter has been calculated from the nozzle throat to the far-field region. The calculations involved the use of recently improved rocket engine nozzle/plume codes. The flow field is discussed, and a brief overview of the calculation techniques is presented. In addition, a proposed on-orbit plume measurement experiment, designed to improve future estimations of the Vernier flow field, is addressed.

Cerimele, Mary P.

Model aerodynamic test results for two variable cycle engine coannular exhaust systems at simulated takeoff and cruise conditions

Wind tunnel tests were conducted to evaluate the aerodynamic performance of a coannular exhaust nozzle for a proposed variable stream control supersonic propulsion system. Tests were conducted with two simulated configurations differing primarily in the fan duct flowpaths: a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At take off conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less.

Nelson, D. P.

Model aerodynamic test results for two variable cycle engine coannular exhaust systems at simulated takeoff and cruise conditions. Comprehensive data report. Volume 2: Tabulated aeroynamic data book 1

Tabulated data from wind tunnel tests conducted to evaluate the aerodynamic performance of an advanced coannular exhaust nozzle for a future supersonic propulsion system are presented. Tests were conducted with two test configurations: (1) a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and (2) an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At takeoff conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less. Data are provided through test run 25.

Nelson, D. P.

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Jet noise characteristics of unsuppressed duct burning turbofan exhaust system

Recent aero-acoustic tests of model coannular nozzles have shown that less noise is generated if the higher-velocity jet is exhausted from the outer annular passage rather than from the primary nozzle. These findings are of particular significance to a duct-burning turbofan (DBTF) engine being studied for application to an advanced supersonic transport. Unlike conventional turbofan engines that have peak velocities from the primary nozzle, it is possible to design a DBTF engine to have a fan velocity higher than that of the primary flow. Results are presented for a NASA-sponsored model test program that covers a range of fan to primary-area ratios from 0.75 to 1.2, and a range of fan to primary-velocity ratios from 0.4 to 2.8. Correlations are given that relate radiated sound power to fan velocity, fan to primary-velocity ratio, and fan to primary-area ratio. Corresponding exhaust-plume velocity-traverse data are presented which suggest that the observed noise benefits may be due to the more rapid decay of the annular flow because of shear stresses on the inner surface that result from the lower-velocity primary flow.

Packman, A. B.

Investigation of advanced thrust vectoring exhaust systems for high speed propulsive lift

The paper presents the results of a wind tunnel investigation conducted at the NASA-Langley research center to determine thrust vectoring/induced lift characteristics of advanced exhaust nozzle concepts installed on a supersonic tactical airplane model. Specific test objectives include: (1) basic aerodynamics of a wing body configuration, (2) investigation of induced lift effects, (3) evaluation of static and forward speed performance, and (4) the effectiveness of a canard surface to trim thrust vectoring/induced lift forces and moments.

Hutchison, R. A.

Scale model test results of a thrust reverser concept for advanced multi-functional exhaust systems

An evaluation is made of scale model test results for a 'block-and-turn' thrust reverser design consisting of an internal flow blocker, internal doors, two ports located on the top and bottom of the exhaust duct, cascade-turning vanes located at the port exit to turn the flow, and external doors which guide the exhaust flow. Numerous geometric variations were incorporated in order to obtain parametric aerodynamic design criteria. The baseline reverser configuration exceeded predicted levels of performance. Skewed vane cascade concepts can be as effective in turning the flow as the baseline vane concept.

Kuchar, A. P.