Search NASASearch

SEARCH · Search NASA

Results for “EXHAUST SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Demonstration of the carbon capture with building make-up air unit

Building-integrated carbon capture technology has the potential to reduce the cost of CO 2 capture while improving indoor air quality (IAQ). To promote the adoption of CO 2 capture in a building environment, this study investigated the possibility of integrating carbon capture technology with an existing rooftop make-up air unit (MAU) system to trap CO 2 . Here, in this study, a modular compact CO 2 capture system containing amine-functionalized polymer fibers was examined. The system, which was installed at the exhaust of the MAU, captures CO 2 before it leaves the building to enter the atmosphere as a greenhouse gas. The demonstrated average amount of CO 2 captured was 1.1–1.4 mmol/g of adsorbent material. Techno-economic analysis (TEA) was further performed on the CO 2 capture system, considering material costs, energy costs, as well as transportation and regeneration costs. These results were then used to estimate the levelized cost per ton CO 2 captured (LCOC). To achieve LCOC below $\$$100/t-CO 2 , adsorbents should have working capacities of 4.9 t and 3 t-CO 2 /year for 5 years and 10 years of operation, respectively. In summary, this study highlights a viable path toward the decarbonization of the commercial buildings sector and provides quantitative performance and economic insight on the suitability of building-integrated carbon capture technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Double-null power-sharing dynamics in MAST-U

Maintaining an effective double-null (DN) configuration is expected to be challenging in reactor-scale tokamak devices. As divertor power-sharing is closely linked to the magnetic topology, even minor variations can lead to fast power-sharing fluctuations which exacerbate the already daunting exhaust challenge. While the static aspects of DN power-sharing have been extensively studied across various devices, this paper presents the first detailed investigation of its dynamic behaviour. We employ dedicated H-mode experiments in MAST-U, in Super-X divertor configuration, featuring perturbation frequencies up to 200 Hz. Our results clearly show no significant dynamic damping of the power-sharing within this frequency range: the divertor responds equally to both fast and slow perturbations. Moreover, the dynamic response also aligns with quasi-static results from slow ramps, implying that static power-sharing models remain valid even for fast fluctuations. Occasionally, some deviations from the otherwise mainly linear behaviour are observed, alongside notable scatter and asymmetries between upwards and downwards trajectories. These observations are likely linked to changes in core conditions, though the underlying mechanisms remain unclear and require further study.

divertor

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS

Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.

42 ENGINEERING

Results from the last DD and DT JET campaigns in the framework of the EUROfusion Tokamak Exploitation Work Package activity

JET, the only tokamak capable of operating with deuterium–tritium (D–T) fuel (since TFTR was shutdown in 1999), has provided essential experimental data to support ITER and DEMO design and operation. Within the EUROfusion Tokamak Exploitation Work Package, JET completed its final campaigns (2022–2023), culminating in the third D–T campaign (DTE3). These experiments addressed key challenges in plasma scenarios, exhaust control, and tritium management under reactor-relevant conditions. Significant progress was achieved in demonstrating ITER-like integrated scenarios with impurity seeding, achieving partial divertor detachment and high confinement ($H_{98}(y,2)$ ≈ 0.85) at 3 MA in D–T plasmas. Advanced exhaust regimes such as quasi-continuous exhaust (QCE) and X-point radiator (XPR) were successfully achieved first in D–D and then extended to D–T operation, confirming their relevance for mixed isotope operation. Operational milestones included a new world record of 69 MJ fusion energy in tritium-rich hybrid plasmas and long-pulse H-mode operation up to 60 s, contributing with unique data to the CICLOP database. Physics studies focused on peeling-limited pedestals in support of ITER and improved understanding of edge stability and impurity screening in metallic environments. Extensive usage of the shattered pellet injector (SPI) on JET provided critical information for the design of the ITER disruption mitigation system (DMS). Real-time control systems for D/T ratio control and plasma exhaust were deployed and demonstrated in D–D and D–T, while energetic particle physics investigations unfolded the role of fast ions in turbulence suppression mechanisms. Comprehensive tritium retention studies using gas balance method, post-mortem analysis, and ITER-relevant laser induced desorption spectroscopy (LIDS) diagnostics provided essential input for tritium accountancy strategies. These results are validating the ITER operational concepts, inform DEMO design, and deliver critical experience in nuclear operation and scenario integration.

disruptions

Large-Eddy Simulation Study of Flow and Combustion Dynamics in a Full-Scale Hydrogen–Air Rotating Detonation Combustor-Stator Integrated System

In the present work, a first-of-its-kind three-dimensional (3D) large-eddy simulation (LES) study is conducted to numerically investigate the combustion dynamics as well as aero-thermal phenomena in a full-scale nonpremixed hydrogen–air rotating detonation engine (RDE) (with a diverging-shaped lower-end wall), when integrated with nozzle guide vanes (NGV) acting as the turbine stator. The wall-modeled LES framework incorporates hydrogen–air detailed chemical kinetics and adaptive mesh refinement (AMR). A comparative analysis is carried out for two operating conditions with different fuel/air mass flow rates but global equivalence ratio of unity, and considering RDE configurations without and with stator. The LES model is validated against available experimental data for the low mass flux condition with respect to detonation wave speed/height, wave dynamics, and axial static pressure distribution. Numerical results indicate significant deflagrative combustion occurring in the fill region near the inner wall due to formation of recirculation zones in the injection near-field driven by the backward facing step. The leading detonation wave is found to be trailed by an azimuthal reflected-shock combustion (ARSC) wave, consistent with experimental observations, which consumes unburned vitiated reactants that leak through the main detonation wave. The main detonation wave characteristics, such as detonation wave speed/height and combustion efficiency, do not change appreciably with the presence of NGV. A novel combustion diagnostic technique based on chemical explosive mode analysis (CEMA) is employed to quantify the fraction of heat release occurring in the detonative mode versus deflagrative mode for the simulated conditions. The exit flow is found to be nearly fully subsonic and supersonic for the low and high mass flux conditions, respectively. Further analysis of the exit flow profiles shows that the presence of NGV renders the flow more axial and significantly impacts the exit Mach number and total pressure, while the total temperature shows negligible change. In addition, the low mass flux operating point, despite exhibiting more deflagrative losses within the combustor, yields overall lower pressure drop from plenum to exhaust, which is mainly attributed to lower pressure drop across the injectors. Lastly, the rotating detonation engine-nozzle guide vanes (RDE-NGV) configuration exhibits higher total pressure loss compared to rotating detonation engine (RDE) without stator across both the mass flux conditions. In conclusion, this study extends the state-of-the-art in numerical modeling of pressure gain combustion (PGC) systems by demonstrating high-fidelity 3D reacting LES of full-scale RDE-NGV systems relevant to RDE-turbine integration for stationary power generation.

Combustion

Simultaneous Reduction of NOx and Fuel Consumption for Off-Road Powertrains

Simultaneously reducing criteria pollutants and fuel consumption is important for clean air and improving vehicle total cost of ownership. The goal of this effort was focused on a 90% NOx reduction and 10% fuel savings for an off-road 407 kW diesel engine. The baseline was a production Fiat Powertrain 13L engine and aftertreatment system meeting 0.4 g/kW-hr NOx. The baseline system was quantified over the NRTC, RMC, new low load cycle and five field cycles. A next generation engine was built incorporating several fuel-efficient design features, including a higher compression ratio, increased fuel-rail pressure, low-friction piston rings, and a high-efficiency variable-geometry turbocharger. Cylinder deactivation and EGR pump technologies were added to this engine as well. The combination was optimized prior to adding advanced aftertreatment systems, showing the trade-off of engine out NOx and exhaust temperature. Two next-generation catalyst technologies were employed into a LO-SCR plus main SCR system, both with and without an electric heater upstream of the LO-SCR. These catalysts were hydrothermally aged to simulate significant field use. Dual SCR dosing with newly developed controls played a critical role in achieving the proper split between the upstream LO-SCR and the downstream main SCR. Adding a next generation mixer for the downstream SCR proved essential in obtaining the final results. The optimal configuration required adding an electric heater to elevate the exhaust temperature at the LO-SCR for early cycle NOx reduction. The final results showed a 94.8% NOx reduction and 15.7% fuel savings on the composite NRTC.

McCarthy, James [Eaton Corporation]

A Large-Scale Analysis to Optimize the Control and V2V Communication Protocols for CDA Agreement-Seeking Cooperation

Cooperative driving automation (CDA) Class C, agreement-seeking cooperation, is an innovative and practical solution that can promote cooperation among general passenger vehicles on the road. However, more comprehensive studies are needed before establishing the standard protocols of agreement-seeking cooperation, such as communication frequency and the duration of cooperation. Here, this article presents an initiative study on the impacts of communication capabilities on agreement-seeking cooperation. Through a large-scale analysis by regulating vehicle-to-vehicle (V2V) communication metrics, this work suggests desirable system parameters that can maximize the benefits of cooperation and ensure reliable operability while avoiding exhaustive communication loads. As the first step, an example agreement-seeking cooperation system is created for a car-following scenario, including decision-making and control algorithms for autonomous vehicles. Then, software-in-the-loop tests explore the performance of the developed system as it encounters various communication risks, such as latency and message packet drops. The system performance metrics are evaluated from various angles, including the time consumed for the agreement-seeking process, cooperation ratio, and the ratio of faulty cooperation. Energy saving from the cooperation is assessed by using simulation software that can run multiple high-fidelity vehicle models simultaneously. Based on the analyses, this article suggests the V2V communication requirements for the reliable operation of CDA agreement-seeking, which can be referred to when developing the standard protocols of agreement-seeking cooperation.

42 ENGINEERING

A Life Cycle Analysis Framework for Point Source Capture Systems

NETL studies the costs and benefits of PSC for electricity, industry, and mobile applications. Mobile point source capture (MPSC) and storage applied to freight modes captures emissions directly from exhaust. This poster presents a framework for conducting LCA of PSC systems applied to heavy-duty trucks, freight trains, and marine vessels. The framework defines a wheels-to-storage (gate-to-grave) boundary, including energy demands (electricity, heat, and cooling requirements), solvent use and cycling, onboard system components, carbon storage in a saline aquifer, and upstream manufacturing impacts for equipment, with a suggested functional unit of 1 tonne-km. Potential data sources for analysis include material, energy, and operational data from Oak Ridge National Laboratory, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model, and scientific literature. The suggested analytical approach includes comparison to publicly available business-as-usual systems without capture across all modes of transportation, sensitivity to composition of the capture solvent, and sensitivity to capture rate variation, all of which would support a wholistic PSC business case analysis. For future consideration, analysis can be augmented with consideration of different sources of electricity (e.g., nuclear), fuel substitution, deploying supportive infrastructure such as pipeline offloading points, and downstream applications like enhanced oil recovery (EOR).

life cycle analysis (LCA)

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Identification and control of the exhaust using gas perturbations in the DIII-D tokamak

This paper presents perturbative experiments that enable the validation and development of control-oriented models for exhaust control. We identify the response of the divertor plasma and scrape-off layer in the DIII-D tokamak to deuterium and nitrogen multi-sine perturbations, in favorable and unfavorable field directions for H-mode access. We obtained good signal-to-noise ratios in the 1–10 Hz frequency range by measuring Balmer-alpha, Lyman-alpha, and N 4+ line emission, radiated power, and neutral pressure. We find a similar phase response across gas species and magnetic field directions, while the gain response is nonlinear. With these experiments, we identify a control-oriented model to design a divertor radiated power controller to track specified reference waveforms in conjunction with resonant magnetic perturbations. Although the physics basis for compatibility between detachment and resonant magnetic perturbation edge-localized mode suppression remains to be demonstrated, the present results provide a robust controller that represents a promising step toward future joint control strategies.

detachment control

Machine learning mathematical models for incidence estimation during pandemics

Accurate estimates of the incidence of infectious diseases are key for the control of epidemics. However, healthcare systems are often unable to test the population exhaustively, especially when asymptomatic and paucisymptomatic cases are widespread; this leads to significant and systematic under-reporting of the real incidence. Here, we propose a machine learning approach to estimate the incidence of a pandemic in real-time, using reported cases and the overall test rate. In particular, we use Bayesian symbolic regression to automatically learn the closed-form mathematical models that most parsimoniously describe incidence. We develop and validate our models using COVID-19 incidence values for nine different countries, confirming their ability to accurately predict daily incidence. Remarkably, despite the differences in epidemic trajectories and dynamics across countries, we find that a single model for all countries offers a more parsimonious description and is more predictive of actual incidence compared to separate models for each country. Our results show the potential to accurately model incidence in real-time using closed-form mathematical models, providing a valuable tool for public health decision-makers.

Fajardo-Fontiveros, Oscar (ORCID:0000000207058972)

Oneida Indian Nation Facility Energy Efficiency Project (Final Technical Report)

The Oneida Indian Nation (“Oneida”) implemented a comprehensive energy efficiency project across nearly 30 facilities over the course of the project period. Grounded in findings from a 2018 energy audit, the project installed LED lighting, high-efficiency HVAC systems, programmable thermostats, variable speed drives, and kitchen exhaust controls across 28 Nation facilities and the Turning Stone Resort and Casino (TSRC) campus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Scalability analysis of heavy-duty gas turbines using data-driven machine learning

With the increasing integration of variable renewable energy sources into power systems, the role of flexible power generation technologies like gas turbines (GT) in rapid grid balancing remains crucial. This sustained importance underscores the need for scaled and precise modeling of GT to ensure effective integration within evolving energy frameworks. While physics-driven GT models integrate thermodynamics, fluid dynamics, and combustion principles, they often rely on approximate mathematical representations to accommodate scaling that may not capture the actual complex dynamics for GTs and inertial effects associated to GTs with different ratings. In this study, a data-driven model is proposed using machine learning (ML) techniques to conduct GT scalability analysis and performance evaluation with high accuracy. The ML model, trained on data from various operating conditions and performance parameters, aims to uncover intricate relationships and patterns, resembling GT characteristics at different scales (ratings). The model is developed to capture complex system interaction and to adapt to changing operational scenarios at different capacities, providing valuable insights of power system dynamics. In this study, the real-time digital simulator platform was employed to generate training data for the ML model and assess its dynamic characteristics. The ultimate objective was to develop a detailed modeling framework based on governing equations and data-driven ML capable of predicting key performance indicators, in thermal systems such as GTs, including power output, speed, fuel consumption, and exhaust temperature under diverse operating conditions at different scales. The developed ML framework demonstrated high accuracy, with mean relative errors for GT power prediction, reference speed, exhaust temperature, and compressor pressure ratio (CPR) parameters consistently below 0.1% across typical load fluctuation scenarios. Maximum deviations were limited to approximately 0.5 K for exhaust temperature and 0.009 for CPR, underscoring the model’s ability to replicating dynamic GT behavior with high precision. The adaptability of the ML model enables its application across diverse operational conditions and its extension to other thermal systems. By leveraging advanced ML techniques, this study presents a robust and scalable modeling framework that enhances GT simulation precision, facilitating improved integration into evolving power systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Optimizing Solar PV Deployment in Manufacturing: A Morphological Matrix and Fuzzy TOPSIS Approach

The growing energy demand of the industrial sector and the need for sustainable solutions highlight the importance of efficient decision making in solar photovoltaic (PV) implementation. Selecting optimal PV configuration is complex due to the interdependent technical, economic, environmental, and social factors involved. This study introduces an integrated decision-making method combining a morphological matrix and fuzzy TOPSIS to systematically select and rank optimal PV system configurations for manufacturing firms. While the morphological matrix exhaustively examines possible design solutions based on sensing, smart, sustainable, and social (S4) attributes, the fuzzy TOPSIS method ranks the alternatives by handling uncertainty in decision making. A case study conducted in a Mexican manufacturing company validates the methodology’s effectiveness. The optimal PV configuration identified comprehensively addresses operational and sustainability criteria, covering all lifecycle stages. This approach demonstrates quantitative superiority and greater robustness compared to existing fuzzy TOPSIS-based methods for solar PV applications. The findings highlight the practical value of data-driven, multi-criteria decision making for industrial solar energy adoption, enhancing project feasibility, cost efficiency, and environmental compliance. Future research will incorporate discrete event simulation (DES) to further refine energy consumption strategies in manufacturing.

Briceño, Citlaly Pérez

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator

Developing Scenario‐Based Strategies for Health, Climate, and Environmental Preparedness: The One Health, One Earth Approach

Climate change amplifies many threats to human health. Despite advances in understanding climate change dynamics and impacts, there remains a critical gap in translating scientific knowledge into equitable, and community-driven health interventions. The inaugural One Earth, One Health workshop sought to explore this gap through human-centered design exercises involving interdisciplinary researchers from climate and Earth sciences, engineering, epidemiology, microbiology, and environmental health. Although participants did not co-develop solutions with affected communities, they used stakeholder role-playing to guide ideation and lay groundwork for actionable plans. Through these methods, participants identified community needs and proposed prototype solutions to alleviate health threats exacerbated by global environmental change. Prototypes were organized around infectious diseases, extreme weather, and air quality, as illustrative themes rather than an exhaustive set of risks. Key solutions included strategies for anticipatory systems and early warning (e.g., integrating environmental signals with health data), inclusive communication and infrastructure needs for responding to extreme weather events, and integrated platforms visualizing air quality trends to support tailored, context-aware guidance beyond one-size-fits-all alerts. The workshop highlighted opportunities such as leveraging machine learning, Earth observation, and real-time surveillance to protect communities, but also noted barriers including data quality, technological redundancy, privacy, and governance challenges. Additionally, participants emphasized the need for interdisciplinary teams capable of collaborating across sectors, breaking down silos and addressing gaps in training and education. Overall, the workshop illustrates how process-driven, human-centered approaches can help surface user needs and generate testable prototype concepts, while underscoring the importance of direct community partnership for implementation.

Abadi, Azar M. [University of Alabama, Birmingham,